• Title/Summary/Keyword: an endotracheal tube

Search Result 66, Processing Time 0.038 seconds

Cancer Patients Are at High Risk of Mortality if Presenting with Sepsis at an Emergency Department

  • Prachanukool, Thidathit;Tangkulpanich, Panvilai;Paosaree, Possawee;Sawanyawisuth, Kittisak;Sitthichanbuncha, Yuwares
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3423-3426
    • /
    • 2016
  • Background: Sepsis is an emergency condition with high mortality and morbidity rate. There are limited data on the association of cancer as a risk factor for mortality in sepsis patients in the emergency department (ED). Materials and Methods: This retrospective study was conducted at the ED, Faculty of Medicine, Ramathibodi Hospital, Bangkok, Thailand. The study period was between January 1st and December $31^{st}$, 2014. The inclusion criteria were as follows: adult patients over 15 years of age who presented at the ED with suspicion of sepsis, received treatment at the ED, and whose blood culture was found to be positive. Clinical data were recorded from medical records including the Mortality in Emergency Department Sepsis score (MEDS score). The primary outcome of this study was mortality at one month. Multivariate logistic regression analysis was used to identify independent factors associated with death. Results: During the study period, there were 775 eligible patients. The two most common pathogens identified from blood cultures were Staphylococcus aureus (193 patients; 24.9%) and Escherichia coli (158 patients; 20.4%). At one month after presenting at the ED, 110 patients (14.2%) had died. There were four significant factors for death, having cancer, being on an endotracheal tube, initial diagnosis of bacteremia, and high MED scores. Having cancer had an adjusted OR of 2.12 (95% CI of 1.29, 3.47). Conclusions: Cancer patients have double the risk of mortality if presenting with sepsis at the ED.

The Changes of Cuff Pressure from Endotracheal Intubation for Long-term Mechanical Ventilation (장기간 기계호흡 환자에서 기관내 관의 기낭압의 변화)

  • Jung, Bock-Hyun;Park, Whan;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.2
    • /
    • pp.156-165
    • /
    • 2002
  • Background: A tracheal stenosis is caused by mucosal ischemic injury related to a high cuff pressure ($P_{cuff}$) of the endotracheal tube. In contrast, aspiration of the upper airway secretion and impaired gas exchange due to cuff leakage is related to a low $P_{cuff}$. To prevent these complications, the $P_{cuff}$ should be kept appropriately because the appropriate $P_{cuff}$ appears to change according to the patient's daily respiratory mechanics. However, the constant cuff volume($V_{cuff}$) has frequently been instilled to the cuff balloon on a daily basis to maintain the optimal $P_{cuff}$ instead of monitoring the $P_{cuff}$ directly at the patients' bedside. To address the necessity of continuous $P_{cuff}$ monitoring, the change in the $P_{cuff}$ was evaluated at various $V_{cuff}$ levels on a daily basis in patients with long-term mechanical ventilation. The utility of mercury column sphygmomanometer for the continuous monitoring $P_{cuff}$ was also investigated. Method: The change in $P_{cuff}$ according to the increase in $V_{cuff}$ was observed in 17 patients with prolonged endotracheal intubation for mechanical ventilation for 2 week or more. This maneuver measured the change in $P_{cuff}$ daily during the mechanical ventilation days. In addition, the $P_{cuff}$ measured by mercury column sphygmomanometer was compared with the $P_{cuff}$ measured by an automatic cuff pressure manager. Results : There were no statistically significant changes of $P_{cuff}$ during more than 14 days of intubation for mechanical ventilation. However the $V_{cuff}$ required to maintain the appropriate $P_{cuff}$ varied from 1.9 cc to 9.6 cc. In addition, the intra-individual variation of the $P_{cuff}$ was observed from 10 $cmH_2O$ to 46 $cmH_2O$ at constant 3 cc $V_{cuff}$. The $P_{cuff}$ measured by the bedside mercury column sphygmomanometer is well coincident with that measured by the automatic cuff pressure manager. Conclusion: Continuous monitoring and management of the $P_{cuff}$ to maintain the appropriate $P_{cuff}$ level in order to prevent cuff related problems during long-term mechanical ventilation is recommended. For this purpose, mercury column sphygmomanometer may replace the specific cuff pressure monitoring equipment.

Anterior Tracheoplasty -Two Cases Report- (전방 기관성형술 -2례 보고-)

  • Sun, Kyung;Lee, Seo-Won;Kim, Joung-Taek;Kim, Kwang-Ho;Lim, Hyun-Kyoung
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.675-680
    • /
    • 1999
  • We describe here two cases of anterior tracheoplasty utilizing an autologous pericardial patch. One patient was a 9 year-old female who had a congenital long tracheal stenosis associated with major vascular anomalies including pulmonary artery sling. One-stage correction was done under the support of an extracorporeal membrane oxygenation system. She required a prolonged ventilation support for 10 days postoperatively until the implanted pericardium was fixed to the mediastinal structures. The other patient was a 8 year-old male who had acquired tracheal stenosis following a complicated tracheostomy. By applying additional support over the pericardial patch with the costal cartilage, an endotracheal tube could be removed immediately after the operation. Both patients have been doing well in a postoperative follow-up of over a year, and there have been evidences of growth in the reconstructed trachea.

  • PDF

A case of persistent pulmonary hypertension of the newborn: Treatment with inhaled iloprost (Iloprost 흡입 투여로 치료한 신생아 폐고혈압 지속증 1예)

  • Jang, Yoon Young;Park, Hye Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.10
    • /
    • pp.1175-1180
    • /
    • 2009
  • We report a case of a full-term neonate with persistent pulmonary hypertension who developed asphyxia after birth and was treated with iloprost. The neonate had persistent hypoxia and did not respond to supportive treatment. Because inhaled nitric oxide (iNO) was not available in our hospital, inhaled iloprost was administered via an endotracheal tube. This resulted in an immediate elevation of oxygen saturation. Echocardiography revealed the conversion of the right-to-left ductal shunt to the left-to-right one and a decrease of the right ventricular pressure. The use of inhaled iloprost did not cause any significant side effects. Here, we describe our experience where iloprost was used in a neonate with persistent pulmonary hypertension because the standard therapy with inhaled nitric oxide was not available.

DECREASE OF OXYGEN SATURATION DURING DENTAL TREATMENT UNDER GENERAL ANESTHESIA OF DOWN SYNDROME PATIENT WITH CONGENITAL HEART DISEASE -A CASE REPORT- (선천성 심장질환을 가진 다운증후군환자에서 치과치료를 위한 전신마취 시 산소포화도 하강 -증례보고-)

  • Seo, Kwang-Suk;Chang, Ju-Hea;Shin, Teo-Jeon;Kim, Hyun-Jeong
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.5 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • A 26-year-old female patient with Down syndrome visited to recieve dental treatment under gnenral anesthesia 6 years ago. The patient had difficulties in oral examination, radiograph taking and laboratory test. The patient had congenital heart disease and medical consultation based on the echocardiography was provided by a cardiologist indicating that the patient could tolearte general anesthesia during dental treatment. And two times of general anesthesia were administered during a dental treament with the interval of 3 years and no postoperpative complicaton was reported. At the third dental operation, the patient had a relatively good condition and her prescreening test revealed no abnormalities. Without further consultation with a cardiologist, general anesthesia was administered to the patient. Anaesthesia was based on thiopental and ventilation of desflurane and $N_2O$ in oxygen via an endotracheal tube with an appropriate monitoring. During the maintenance of anesthesia, the blood pressure of the patient started to drop and the oxygen saturation also began to decrease. Consequently, the proceding operation was discontinued and also inhalation anesthesia was ceased. As the patient was recovered from anesthesia, her systemic conditions were alleviated. After the complete recovery of the patient, she visited the cardiologist, and the cardiologic test revealed her severe right ventricular dilatation. In the anesthesia of patients with congenital heart disease, information on their systemic conditions needs to be undated from the medical consultation, which assures the safety of treatment.

  • PDF

A Case of a Herbicide Poisoning Induced Methemoglobinemia Patient Treated with High-dose Vitamin C (제초제 중독으로 유발된 메트헤모글로빈혈증 환자에서 고용량 비타민 C 치료 1례)

  • Sun, Kyung Hoon;Kim, Jun Kew;Ryu, Chang Yeon;Kim, Seo Jin;Jo, Hyeon Kyu;Yoo, Tae Ho;Park, Yong Jin;Kim, Sun pyo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.15 no.2
    • /
    • pp.148-151
    • /
    • 2017
  • Methemoglobinemia is a condition in which the iron portion of hemoglobin, which binds to oxygen, is oxidized to produce methemoglobin, which increases blood concentration. There are many causes of methemoglobinemia, the most common being food, drugs, and chemicals. A 75-year-old male patient who had taken an herbicide did not notice any nonspecific symptoms. However, after 4 hours, his methemoglobin levels increased to 17.1%, while after 7 hours it increased to 26.5%, at which time intravenous administration of methylene blue 1 mg/kg (an antidote) was started. After a total of five doses of methylene blue at 1 mg/kg due to reactive methemoglobinemia for about 36 hours, the methemoglobin levels increased to 23.7%. Because no more methylene blue could be administered, 10 g of ascorbic acid (vitamin C) was administered intravenously. After 82 hours, ascorbic acid 10 g was administered six times for repeated reactive methemoglobinemia. No additional reactive methemoglobinemia was observed. The ventilator and endotracheal tube were successfully removed on day 5 after admission.

Advantages, Disadvantages, Indications, Contraindications and Surgical Technique of Laryngeal Airway Mask

  • Anubhav, Jannu;Ashim, Shekar;Ramdas, Balakrishna;Sudarshan, H.;Veena, G.C.;Bhuvaneshwari, S.
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.4
    • /
    • pp.223-229
    • /
    • 2017
  • The beauty of the laryngeal mask is that it forms an air tight seal enclosing the larynx rather than plugging the pharynx, and avoid airway obstruction in the oropharynx. The goal of its development was to create an intermediate form of airway management face mask and endotracheal tube. Indication for its use includes any procedure that would normally involve the use of a face mask. The laryngeal mask airway was designed as a new concept in airway management and has been gaining a firm position in anesthetic practice. Despite wide spread use the definitive role of the laryngeal mask airway is yet to be established. In some situations, such as after failed tracheal intubation or in oral surgery its use is controversial. There are several unresolved issues, for example the effect of the laryngeal mask on regurgitation and whether or not cricoids pressure prevents placement of mask. We review the techniques of insertion, details of misplacement, and complications associated with use of the laryngeal mask. We then attempt to clarify the role of laryngeal mask in air way management during anesthesia, discussing the advantages and disadvantages as well as indications and contraindications of its use in oral and maxillofacial surgery.

Clinical Study of Children Using Home Mechanical Ventilation (가정용 인공 호흡기를 사용하는 소아의 임상적 고찰)

  • Ahn, Young Joon;Lee, Seung Hyeon;Kim, Hyo-Bin;Park, Seong Jong;Ko, Tae Sung;Hong, Soo Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.4
    • /
    • pp.401-405
    • /
    • 2005
  • Purpose : The use of mechanically-assisted ventilators at home reduces morbidity and improves the quality of life in children with chronic respiratory failure. But in Korea there is no clinical data of children with home mechanical ventilation. We investigated ventilator types, duration, the causes of failure or death, and the cost needed for care. Methods : We retrospectively analyzed the medical records of 21 children who were admitted and who applied for home mechanical ventilation at the Pediatric Intensive Care Unit in Asan Medical Center. Phone interviews took place after discharge. and interviewed by phone after discharge. Results : The median age was 31 months; the median duration with ventilator was 25 months. Underlying diseases were 16 neuromuscular diseases, one metabolic disease and four chronic respiratory diseases. The types of ventilator were pressure and volume type(16 and five patients, respectively). The frequency of ventilation failure was once per 19 months. Weaning could be performed in three cases. Frequencies of admission after receiving ventilators were 1.7 times per year; the most common cause was pneumonia. Nine patients(43%) died; four of them died because of endotracheal tube obstruction. The costs for medical care were about 1,110,000 won per month. Conclusion : There is an increment in the numbers of individuals who need mechanical ventilation support. The most common cause of death was endotracheal tube obstruction. The most important problem for the patients was medical cost. There needs to be more interest in patients with ventilator and social welfare systems to support their families need to be prepared.

The Influences of Obstructive Apneas on Changes of Cardiovascular Function in Anesthetized Dogs with $\alpha$-chloralose ($\alpha$-chloralose로 마취한 개에서 폐쇄성 무호흡이 심혈관계 기능변화에 미치는 영향)

  • Jang, Jae-Soon;Kang, Ji-Ho;Lee, Sang-Haak;Choi, Young-Mee;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.3
    • /
    • pp.347-356
    • /
    • 2000
  • Background : Patients with obstructive sleep apnea syndrome are known to have high long-term mortality compared to healthy subjects because of their cardiovascular dysfunction. The observation of hemodynamic changes by obstructive apneas is helpful when attempting to understand the pathophysiological mechanism of the development of cardiovascular dysfunction in those patients. Therefore, we studied the changes in cardiovascular function with an animal model and tried to obtain the basic data for an ideal experimental model (this phrase is unclear), a requirement for a more advanced study. Methods : Sixteen anesthetized dogs with ${\alpha}$-chloralose delete were divided into two groups : 8 dogs of room air breathing group and 8 dogs of oxygen breathing group. We measured $PaO_2$, $PaCO_2$, heart rate, cardiac output, mean femoral artery pressure, and mean pulmonary artery pressure at specified times during the apnea-breathing cycle before endotracheal tube occlusion (baseline), 25 seconds after endotracheal tube occlusion (apneic period), 10 seconds (early phase of postapneic period, EPA) and 25 seconds (late phase of postapneic period, LPA) after spontaneous breathing. Results : In room air breathing group, the heart rate significantly decreased during the apneic period compared to that at baseline (P<0.01) and increased at EPA and LPA compared to that during the apneic period (P<0.01). But, the heart rate showed no significant changes during apneic and postapneic periods in the oxygen breathing group. Cardiac output tended to decrease during apneic period compared to that at baseline, but was statistically significant. Cardiac output significantly decreased at LP A compared to at baseline (P<0.01). Mean femoral artery pressure was significantly decreased at during apneic period compared to that at baseline (P<0.05). Conclusion : Through this experiment, we were partially able to understand the changes of cardiovascular function indirectly, but delete new experimental animal model displaying physiological mechanism close to natural sleep should be established, and the advanced study in the changes of cardiovascular function and their causes should be continued.

  • PDF

A Study on the Effects of the Early Use of Nasal CPAP in the Weaning of Mechanical Ventilators (인공호흡기 이탈시 비강내 CPAP 조기 사용 효과에 관한 연구)

  • Kim, Yeoung Ju;Jung, Byun Kyung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1200-1206
    • /
    • 2003
  • Purpose : This study was conducted for the use of nasal continuous positive airway pressure (CPAP), by comparing the early use of non-invasive nasal CPAP with low intermittent mandatory ventilation(low IMV) and endotracheal CPAP in weaning a mechanical ventilator from infants with moderate respiratory distress syndrome(RDS). Methods : Thirty infants in the study group, with moderate RDS from November 2001 to June 2002, were administered surfactants and treated with the mechanical ventilator, and applied the nasal CPAP in weaning. Thirty infants of the control group, from January 1999 to September 2001, were applied low IMV and endoctracheal CPAP in weaning. Results : There were no significant differences in the characteristics, the severity of clinical symptoms, the initial laboratory findings and settings of the mechanical ventilator. After weaning, the study group showed no significant changes in $PaCO_2$. However, the control group showed a slight $CO_2$ retension after one and 12 hours. Twenty eight infants(93.3%) of the study group and 24 infants(80%) of the control group were successfully extubated. The primary cause of failure was apnea. There were no significant differences in the duration of weaning and the mechanical ventilator treatment between the groups. Complications in weaning were related to the fixation of nasal CPAP and the mechanical problems caused by endotracheal tube. Conclusion : Aggressive weaning is possible for moderate RDS, in which the nasal CPAP was used without the low IMV and the endotracheal CPAP process. It had no difficulties. In conclusion, the nasal CPAP is an adequate weaning method for moderate RDS.