• Title/Summary/Keyword: amplitude-comparison

Search Result 428, Processing Time 0.038 seconds

Temporal and Spatial Analysis of SST in the Northeast Asian Seas Using NOAA/AVHRR data (NOAA/AVHRR 자료에 의한 동북아시아해역 표층해수온의 시공간분석)

  • Min, Seung-Hwan;Kim, Dae-Hyun;Yoon, Hong-Joo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2818-2826
    • /
    • 2010
  • To study the spatial and temporal variations of sea surface temperature(SST) in the Northeast Asia sea during the period of 1985 to 2009. At first, the buoy data from Korea Meteorological Administration(KMA) and the satellite data have been matched up eight points. The root mean square error and the bias were increased towards the coastal shallow region. The study area which is divided 7 regions from Japan Meteorological Agency(JMA). We analyzed NOAA/AVHRR data by harmonic analysis which is comparison and analysis the center of the each regions. The mean SST varied between $8^{\circ}C$ to $26.0^{\circ}C$. The annual amplitude varied between $7^{\circ}C$ to $24^{\circ}C$. And the annual phase varied between end of July to end of August. Cross-correlation coefficients of mean SST, annual amplitude, and annual phase varied 0.57 to 0.85, -0.04 to 0.81 and 0.35 to 0.80 at all study area, respectively.

Comparison of Muscle Activity According to Hip Abduction Angle during Hip Extension Exercise in Prone Position (엎드린 자세에서 엉덩관절 폄 운동 시 엉덩관절 벌림 각도에 따른 근활성도 비교)

  • Cho, Youn-Ho;Lee, Han-Suk;Park, Sun-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.4
    • /
    • pp.123-129
    • /
    • 2018
  • PURPOSE: This study was conducted to investigate the influence of hip abduction angle on the muscle activity of the Gluteus Maximus (GM), Biceps Femoris (BF) and Tensor Fascia Lata (TFL) during Knee Flexed Prone Hip Extension exercise. METHODS: The subjects of this study were 42 healthy individuals. All participant consented to participate in this study. Subjects performed exercise, using the Knee Flexed Prone Hip Extension exercise in three hip abduction position $0^{\circ}$, $15^{\circ}$ and $30^{\circ}$. Subjects rested two minutes, between changing hip abduction position. Data were analyzed using a Noraxon MR-XP 1.08 Master Edition EMG to determine average amplitude, for each angle and muscle. All data were processed by Multivariate analysis of variance (MANOVA). There were a total of three groups. the GM muscle, BF muscle, TFL muscle. RESULTS: GM muscle activity was greatest in the $30^{\circ}$ hip abduction position (p<.05), followed by $0^{\circ}$. Between $0^{\circ}$ and $30^{\circ}$ has significant difference in muscle activity. However, the BF and TFL amplitude were greatest at $0^{\circ}$ hip abduction position followed by $30^{\circ}$. Moreover, the TFL differed significantly between $0^{\circ}$ and $30^{\circ}$, but, BF did not (p<.05). CONCLUSION: Hip abduction at $30^{\circ}$ was found to be the most appropriate position for GM muscle activity.

Comparison of Classification Performance Between Adult and Elderly Using Acoustic and Linguistic Features from Spontaneous Speech (자유대화의 음향적 특징 및 언어적 특징 기반의 성인과 노인 분류 성능 비교)

  • SeungHoon Han;Byung Ok Kang;Sunghee Dong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.8
    • /
    • pp.365-370
    • /
    • 2023
  • This paper aims to compare the performance of speech data classification into two groups, adult and elderly, based on the acoustic and linguistic characteristics that change due to aging, such as changes in respiratory patterns, phonation, pitch, frequency, and language expression ability. For acoustic features we used attributes related to the frequency, amplitude, and spectrum of speech voices. As for linguistic features, we extracted hidden state vector representations containing contextual information from the transcription of speech utterances using KoBERT, a Korean pre-trained language model that has shown excellent performance in natural language processing tasks. The classification performance of each model trained based on acoustic and linguistic features was evaluated, and the F1 scores of each model for the two classes, adult and elderly, were examined after address the class imbalance problem by down-sampling. The experimental results showed that using linguistic features provided better performance for classifying adult and elderly than using acoustic features, and even when the class proportions were equal, the classification performance for adult was higher than that for elderly.

Comparison of Speech Rate and Long-Term Average Speech Spectrum between Korean Clear Speech and Conversational Speech

  • Yoo, Jeeun;Oh, Hongyeop;Jeong, Seungyeop;Jin, In-Ki
    • Korean Journal of Audiology
    • /
    • v.23 no.4
    • /
    • pp.187-192
    • /
    • 2019
  • Background and Objectives: Clear speech is an effective communication strategy used in difficult listening situations that draws on techniques such as accurate articulation, a slow speech rate, and the inclusion of pauses. Although too slow speech and improperly amplified spectral information can deteriorate overall speech intelligibility, certain amplitude of increments of the mid-frequency bands (1 to 3 dB) and around 50% slower speech rates of clear speech, when compared to those in conversational speech, were reported as factors that can improve speech intelligibility positively. The purpose of this study was to identify whether amplitude increments of mid-frequency areas and slower speech rates were evident in Korean clear speech as they were in English clear speech. Subjects and Methods: To compare the acoustic characteristics of the two methods of speech production, the voices of 60 participants were recorded during conversational speech and then again during clear speech using a standardized sentence material. Results: The speech rate and longterm average speech spectrum (LTASS) were analyzed and compared. Speech rates for clear speech were slower than those for conversational speech. Increased amplitudes in the mid-frequency bands were evident for the LTASS of clear speech. Conclusions:The observed differences in the acoustic characteristics between the two types of speech production suggest that Korean clear speech can be an effective communication strategy to improve speech intelligibility.

Assessment of nonlocal nonlinear free vibration of bi-directional functionally-graded Timoshenko nanobeams

  • Elnaz Zare;Daria K. Voronkova;Omid Faraji;Hamidreza Aghajanirefah;Hamid Malek Nia;Mohammad Gholami;Mojtaba Gorji Azandariani
    • Advances in nano research
    • /
    • v.16 no.5
    • /
    • pp.473-487
    • /
    • 2024
  • The current study employs the nonlocal Timoshenko beam (NTB) theory and von-Kármán's geometric nonlinearity to develop a non-classic beam model for evaluating the nonlinear free vibration of bi-directional functionally-graded (BFG) nanobeams. In order to avoid the stretching-bending coupling in the equations of motion, the problem is formulated based on the physical middle surface. The governing equations of motion and the relevant boundary conditions have been determined using Hamilton's principle, followed by discretization using the differential quadrature method (DQM). To determine the frequencies of nonlinear vibrations in the BFG nanobeams, a direct iterative algorithm is used for solving the discretized underlying equations. The model verification is conducted by making a comparison between the obtained results and benchmark results reported in prior studies. In the present work, the effects of amplitude ratio, nanobeam length, material distribution, nonlocality, and boundary conditions are examined on the nonlinear frequency of BFG nanobeams through a parametric study. As a main result, it is observed that the nonlinear vibration frequencies are greater than the linear vibration frequencies for the same amplitude of the nonlinear oscillator. The study finds that the difference between the dimensionless linear frequency and the nonlinear frequency is smaller for CC nanobeams compared to SS nanobeams, particularly within the α range of 0 to 1.5, where the impact of geometric nonlinearity on CC nanobeams can be disregarded. Furthermore, the nonlinear frequency ratio exhibits an increasing trend as the parameter µ is incremented, with a diminishing dependency on nanobeam length (L). Additionally, it is established that as the nanobeam length increases, a critical point is reached at which a sharp rise in the nonlinear frequency ratio occurs, particularly within the nanobeam length range of 10 nm to 30 nm. These findings collectively contribute to a comprehensive understanding of the nonlinear vibration behavior of BFG nanobeams in relation to various parameters.

Stroke Recovery Can be Enhanced by using Repetitive Transcranial Magnetic Stimulation Combined with Mirror Therapy

  • Ji, Sang-Goo;Cha, Hyun-Gyu;Kim, Myoung-Kwon
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.28-31
    • /
    • 2014
  • The aim of the present study was to examine whether mirror therapy, in conjunction with repetitive transcranial magnetic stimulation (rTMS), can improve the upper extremity function of stroke patient. This study was conducted with 35 subjects, who were diagnosed as a hemiparesis by stroke. The Mirror plus rTMS group was of 12 members who undertook mirror therapy in conjunction with rTMS, the Mirror group was of 11 members who undertook mirror therapy, and the control group was of 12 members who undertook sham therapy. A motor cortex excitability was performed by motor evoked potential, and upper limb function was evaluated by Fugl-Meyer Assessment, and Box and Block Test. Significant difference was shown after the experiment, in comparison of the groups in terms of latency, and as the result of post hoc test, significant difference was shown between the Mirror plus rTMS group and control group, and between the Mirror group and control group, respectively. Significant difference was shown after the experiment in comparison of the groups in amplitude, and as the result of post hoc test, significant difference was shown between the Mirror plus rTMS group and Mirror group, and between the Mirror plus rTMS group and control group. Significant difference was shown after the experiment, in comparison of the groups in FMA and BBT, and as the result of post hoc test, significant difference was shown between the Mirror plus rTMS group and Mirror group, and between the Mirror group and control group. The study showed that mirror therapy in conjunction with rTMS is more effective to improve upper extremity function, than mirror therapy and sham therapy.

Comparison of Lateral Pile Behavior under Static and Dynamic Loading by Centrifuge Tests (원심모형 실험을 이용한 지반-말뚝 상호작용의 정적 및 동적 거동 평가)

  • Yoo, Min-Taek;Kwon, Sun-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.7
    • /
    • pp.51-58
    • /
    • 2018
  • In this study a series of centrifuge tests were carried out in dry sand to analyze the comparison of lateral pile behavior for static loading and dynamic loading condition. In case of static loading condition, the lateral displacement was applied up to 50% of pile diameter by deflection control method. And the input sine wave of 0.1 g~0.4 g amplitude and 1 Hz frequency was applied at the base of the soil box using shaking table for dynamic loading condition. From comparison of experimental static p-y curve obtained from static loading tests with API p-y curves, API p-y curves can predict well within 20% error the ultimate subgrade reaction force of static loading condition. The ultimate subgrade reaction force of experimental dynamic p-y curve is 5 times larger than that of API p-y curves and experimental static p-y curves. Therefore, pseudo-static analysis applied to existing p-y curve for seismic design could greatly underestimate the soil resistance at non-linear domain and cause overly conservative design.

The Performance Comparison of MMA and S-MMA Adaptive Equalization Algorithm for QAM Signal (QAM 신호에대한 MMA와 S-MMA 적응 등화 알고리즘의 성능 비교)

  • Kang, Dae-Soo;Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • This paper deals with the performance comparison of blind adaptive equalization algorithm, the MMA and S-MMA, that is used for compensation of the amplitude and phase distortion simultaneously which occurs in the time dispersive channel. The present CMA algorithm is possible to compensates the amplitude only, but not in phase, so it needs to the another additional circuit for compensating the phase. In order to overcoming the abovemensioned shorthand, the improved cost function is applied to the MMA algorithm. In MMA algorithm, the error is consists of the dispersion constant only, but in S-MMA, the error is consists of the dispersion constant considering the output of decision device (sliced symbol) in order to updating the tap coefficients. By using the two kind error signal, the adaptive equalization algorithm has different performance. In this paper, we compare to the adaptive equalization algorithm performance by using the recovered constellation, residual isi, MD (Maximum Distortion) and SER as a index when the transmitting signal is 16 and 64-QAM and then passing through the same communication channel. As a result of simulation, the S-MMA can improving the Roburstness in SER performance compared to the MMA in the high order QAM signal.

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF

Electrophysiologic Characteristics of Combined Idiopathic Carpal Tunnel Syndrome and Tarsal Tunnel Syndrome (동반이환된 특발성 수근관증후군과 족근관증후군의 전기생리학적 특징)

  • Kim, Sung-Hyouk;Yang, Ji-Won;Sung, Young-Hee;Park, Kee-Hyung;Park, Hyeon-Mi;Shin, Dong-Jin;Lee, Yeong-Bae
    • Annals of Clinical Neurophysiology
    • /
    • v.13 no.1
    • /
    • pp.31-37
    • /
    • 2011
  • Background: Carpal tunnel syndrome (CTS) and tarsal tunnel syndrome (TTS) are thought to share a similar pathophysiology, compression of the median and plantar nerve by the carpal tunnel and flexor retinaculum. A few reports introduced the relationship between idiopathic CTS and TTS without definite evidence of coexistence. The current study was designed to analyze the electrophysiologic characteristics of combined idiopathic CTS and TTS by comparing with each idiopathic CTS or TTS. Methods: We retrospectively collected patients with combined idiopathic CTS and TTS (CTS-TTS group) from June 2001 to February 2009. Patients with each idiopathic CTS or TTS were collected as controls. Electrophysiologic data of median and plantar nerves were compared between CTS-TTS group and controls. Results: CTS-TTS group was composed of 31 patients. Control group of each CTS or TTS were 50 CTS and 49 TTS patients. In comparison of median nerve conduction study between CTS-TTS group and CTS control group, decreased compound muscle action potential amplitude (p<0.001), decreased median sensory nerve action potential amplitude (p<0.001) and sensory nerve conduction velocity at finger stimulation (p=0.013) were prominent in CTS-TTS group. Decreased medial plantar sensory nerve action potential amplitude (p=0.034) was indicated when CTS-TTS groups and TTS control group were compared. Conclusions: If the electrophysiology study of patients with CTS or TTS was suggestive of severe degree of nerve injury, concerns about the possibility of combined CTS and TTS would be helpful.