• Title/Summary/Keyword: amplitude-comparison

Search Result 428, Processing Time 0.027 seconds

Diagnostics on Gear Faults Using Transmission Error : Simulation vs Experiment (전달오차를 이용한 기어고장진단: 해석 vs 실험적 방법론)

  • Park, Jungho;Ha, Jongmoon;Choi, Jooho;Park, Sungho;Youn, Byeng D.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.499-502
    • /
    • 2014
  • This paper presents a comparison study between simulation and experiment for fault diagnostics of a spur gear. In simulation, fault diagnostics using transmission error (TE) was performed and concluded to be valid. In a real experiment, however, it is not as easy to detect faults of gears using TE as in simulation. In this paper, after seeding the various faults like tooth crack of different length, tooth breakage and spalling in test rig, TE was calculated. Then, several signal processing techniques were performed to overcome the limitations of an experiment in detecting the fault signals of TE. After signal processing, we could detect the various faults of spur gears and different amplitude of TE sparks from cracks of different length. Then we discussed the difference between simulation and experment.

  • PDF

Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control (시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상)

  • Oh, Ki-Yong;Shin, Yun-Ho;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.837-843
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

  • PDF

Comparison of Gluteus Medius Muscle Electromyographic activity at different hip angles and motions (엉덩관절 가동범위에 따른 중간볼기근의 근활성도 비교)

  • Lee, Tae-Sik
    • Journal of Korean Physical Therapy Science
    • /
    • v.19 no.4
    • /
    • pp.41-46
    • /
    • 2012
  • Background : The purpose of this study was to investigate the electromyographic(EMG) amplitude of the gluteus medius muscle bilaterally at various hip angles and motions(flexion, extension and abduction). Methods : Thirty young with a mean(SD) age of 21.03(1.69) years performed hip motions(flexion, extension and abduction) while the surface EMG activity of the gluteus medius muscles was recorded bilaterally. Subjects were instructed to use the right lower limb during moving 3 different direction. Differences in EMG amplitudes in according with movement direction and angle were assessed by use of paired t-test analyses of variance for the right and left lower extremities. The alpha level was set at .05. Results : Gluteus medius muscle EMG activities in the both side were significantly greater for abduction at angles of 30 degrees than those for other motions at other angles. Conclusion : Hip abduction at angles of 30 degrees on the standing position may be effective in activating the gluteus medius muscle.

  • PDF

인공장기

  • 민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.112-113
    • /
    • 1989
  • Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult.

  • PDF

Pressure Predictions in Exhaust Pipe of a Single Cylinder Gasoline Engine (단기통 가솔린 기관의 배기단의 압력 예측)

  • Choi, S.C.;Lee, H.J.;Kim, S.H.;Koh, D.K.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.24-29
    • /
    • 2004
  • In this study, a computer analysis has been developed for predicting the pipe pressure of the intake and exhaust manifold. To obtain the boundary conditions for a numerical analysis, one dimensional and non-steady gas dynamic calculation is performed by using the MOC(Method Of Characteristic). The main numerical parameters are the variation of the engine revolution to calculate the pulsating flow which the intake and exhaust valves arc working. The comparison of exhaust pressure in case of numerical results is quite matched with in case of experimental results. When engine revaluation is increased, the pressure amplitude showed a high value, but the pressure frequency was decreased.

  • PDF

A study of estimation and removal of baseline drift for the automated diagnosis of electrocardiogram (심전도 자동 진단을 위한 기저선 동요 평가 및 제거에 관한 연구)

  • 권혁제;이명호
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.7
    • /
    • pp.99-106
    • /
    • 1996
  • Estimation and removal procedures for baseline drift have been developed using linear, cubic spline, and bilineared transformed high pass filter. Linear and cubic spline interpolation with the PQ and TP segmens, which are considered to be isoelectric, as fiducial points ahve been estimated respectively. For a quantitative validation of the estimation procedure, 4 ECGs with arfificial baseline drift were constructed and analyzed by mean square error calculations and amplitude histograms. Also real ECGs were analyzed in a test set of the CSE data set 3 and set 4. Baseline drift detecton rule were designed and new method for the decision of fiducial point were constructed to avoid distorting as the case of premature ventricular or atrial contraction. From these comparison, proposed cubic spline method with PQ and TP segment (CS_PQ & TP) emerged as the most efficient method.

  • PDF

Chemical Properties of Cu( II ) Compound Containing Endocrine Disrupter, Bis-Phenol A

  • Park, Chil-Nam
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.121-126
    • /
    • 2001
  • The techniques of pulse and cyclic voltammetry were applied to the determination of (E$_{1}$2)$_2$-(E$_{1}$2)$_1$ for two-step electrochemical charge transfers. In addition, a simple amplitude was derived far the dependence of the differential pulse response on (E$_{l}$ 2/)$_1$ and (E$_{1}$2/)$_2$. and the use of peak to peak separation in cyclic voltammetry and differential pulse methods was evaluated. A comparison of the comproportionation constants(Ke) from differential pulse and cyclic voltammetry methods exhibited a good agreement within 5%.

  • PDF

Theory and Prediction of Turbulent Transition

  • Dou, Hua-Shu;Khoo, Boo-Cheong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.114-132
    • /
    • 2011
  • We have proposed a new approach based on energy gradient concept for the study of flow instability and turbulent transition in parallel flows in our previous works. It was shown that the disturbance amplitude required for turbulent transition is inversely proportional to Re, which is in agreement with the experiments for imposed transverse disturbance. In present study, the energy gradient theory is extended to the generalized curved flows which have much application in turbomachinery and other fluid delivery devices. Within the frame of the new theory, basic theorems for flow instability in general cases are provided in details. Examples of applications of the theory are given from our previous studies which show comparison of the theory with available experimental data. It is shown that excellent agreement has been achieved for several configurations. Finally, various prediction methods for turbulent transition are reviewed and commented.

Effects of the Multi-directional Irregular Waves on the Motion Responses and Tension Variations of ISSC-TLP (ISSC-TLP의 운동응답 및 변동장력에 미치는 다방향 불규칙파의 영향)

  • Lee, Chang-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.4 s.71
    • /
    • pp.70-75
    • /
    • 2006
  • A numerical procedure is described for estimating the effects of the multi-directional irregular waves on the motion responses and tension variations of the ISSC-TLP. The numerical approach is based on a three-dimensional source distribution method and a spectral analysis technique of directional waves. The spectral description for the linear system of ISSC-TLP in the frequency domain is sufficient to completely define the motion responses and tension variations. This is because both the wave inputs and responses are stationary Gaussian random processes, of which the statistical properties in the amplitude domain are well known. The numerical results for the linear motion responses and tension variations in regular waves are compared with the experimental and numerical ones, which are obtained in the literature. The results of comparison confirmed the validity of the proposed approach.

Comparison of Impedance Characteristics of Copper- and Carbon-Eearth Electrode by Application of Various Current Source (다양한 전류원에서 접지동봉과 탄소접지극의 임피던스 특성 비교)

  • Kim, Hwang-Kuk;Moon, Byung-Doo;Ji, Hong-Keun;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.293-296
    • /
    • 2008
  • In this paper, we carried out an comparative analysis on ground impedance of single copper-, three linked copper- and single carbon- electrodes by the application of various current sources such as sine, square, and surge with fast risetime. Impedance of single-copper electrode was the highest among them and was affected as the amplitude and the frequency of applied current. However, impedance characteristics of the three linked copper- and the single carbon- electrodes showed a similar tendency.

  • PDF