• Title/Summary/Keyword: amplitude-comparison

Search Result 426, Processing Time 0.022 seconds

Modified Direct Torque Control System of Five Phase Induction Motor

  • Kim, Nam-Hun;Kim, Min-Huei
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.266-271
    • /
    • 2009
  • In this paper, improved direct torque control(DTC) of five-phase induction motor(IM) is proposed. Due to the additional degrees of freedom, five-phase IM drives present unique characteristics. One of them is the ability of enhancing the torque producing capability of the motor. Also five-phase motor drives possess many others advantage compared with the traditional three-phase motor drives. Such as, reducing the amplitude and increasing of frequency of torque pulsation, reducing amplitude of current per phase without increasing the voltage per phase and increasing the reliability. The direct torque control method is advantageous when it is applied to the five-phase IM. Because the five-phase inverter provides 32 space vectors in comparison to 8 space voltage vectors by the three-phase inverter. The 32 space voltage vectors are divided into three groups according to their magnitudes. The characteristics and dynamic performance of traditional five-phase DTC are analyzed and new DTC for five-phase IM is proposed. Therefore, a more precise flux and torque control algorithm for the five-phase IM drives can be suggested and explained. For presenting the superior performance of the pro-posed direct torque control, experimental results is presented using a 32 bit fixed point TMS320F2812 digital signal processor

Comparison of the Vibration Principal Stress by Experimental and Numerical Waveform (실측 파형과 수치 파형에 의한 진동주응력 비교)

  • Hong, Woong-Ki;Song, Jeong-Un;Park, Young-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.609-615
    • /
    • 2012
  • In recent years, the development of computer technique was possible to the simulation analysis of the structure caused by ground vibration. Generally, finite element method(FEM) has been used in these structural analysis. In this study, it was calculated to the vibration energy as measuring vibration waveform, and estimated about principal stress due to medium characteristics of the ground as processing dynamic analysis by the vibration energy. The results are as follows : Firstly, the principal stress distribution in all mediums was different due to a medium condition, and the principal stress at concrete medium was represented to difference due to physical characteristics. Secondly, the principal stress by time increasing was represented to maximum amplitude within 0.03 second. And also, the principal stress after maximum amplitude was very large at concrete medium, which was considered to be formed compression or tension range at a medium boundary. Thirdly, the variation of principal stress at concrete medium was represented in the order of RC medium, NC=H medium, NC=S medium. It was considered that the vibration energy propagated fast when a medium have a big elasticity and density.

Fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete composite beams

  • Han, Qing-Hua;Wang, Yi-Hong;Xu, Jie;Xing, Ying
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.353-368
    • /
    • 2016
  • This paper extends our recent work on the fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete (RRFC) composite beams. A series of 16 fatigue push-out tests were conducted using a hydraulic servo testing machine. Three different recycled tyre rubber contents of concrete, 0%, 5% and 10%, were adopted as main variable parameters. Stress amplitudes and the diameters of studs were also taken into consideration in the tests. The results show that the fatigue lives of studs in 5% and 10% RRFC were 1.6 and 2.0 times greater of those in normal concrete, respectively. At the same time, the ultimate residual slips' values of stud increased in RRFC to highlight its better ductility. The average ultimate residual slip value of the studs was found to be equal to a quarter of studs' diameter. It had also been proved that stress amplitude was inversely proportional to the fatigue life of studs. Moreover, the fatigue lives of studs with large diameter were slightly shorter than those of smaller ones and using larger ones had the risk of tearing off the base metal. Finally, the comparison between test results and three national codes was discussed.

Natural frequencies and response amplitude operators of scale model of spar-type floating offshore wind turbine

  • Hong, Sin-Pyo;Cho, Jin-Rae
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.785-794
    • /
    • 2017
  • This paper is concerned with the comparative numerical and experimental study on the natural behavior and the motion responses of a 1/75 moored scale model of a 2.5 MW spar-type floating offshore wind turbine subject to 1-D regular wave. Heave, pitch and surge motions and the mooring tensions are investigated and compared by numerical and experimental methods. The upper part of wind turbine which is composed of three rotor blades, hub and nacelle is modeled as a lumped mass and three mooring lines are pre-tensioned by means of linear springs. The numerical simulations are carried out by a coupled FEM-cable dynamics code, while the experiments are performed in a wave tank equipped with the specially-designed vision and data acquisition system. Using the both methods, the natural behavior and the motion responses in RAOs are compared and parametrically investigated to the fairlead position, the spring constant and the location of mass center of platform. It is confirmed, from the comparison, that both methods show a good agreement for all the test cases. And, it is observed that the mooring tension is influenced by all three parameters but the platform motion is dominated by the location of mass center. In addition, from the sensitivity analysis of RAOs, the coupling characteristic of platform motions and the sensitivities to the mooring parameters are investigated.

Comparison of Dynamic Sorption and Hygroexpansion of Wood by Different Cyclic Hygrothermal Changing Effects

  • Yang, Tiantian;Ma, Erni
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.191-203
    • /
    • 2016
  • To investigate the dynamic sorptive and hygroexpansive behaviors of wood by different cyclic hygrothermal changing effects, poplar (populus euramericana Cv.) specimens, were exposed to dynamic sorption processes where relative humidity (RH) and temperature changed simultaneously in sinusoidal waves at 75-45% and $5-35^{\circ}C$ (condition A) and where RH changed sinusoidally at 75-45% but temperature was controlled at $20^{\circ}C$ (condition B), both for three cyclic periods of 1, 6, and 24 h. Moisture and dimensional changes measured during the cycling gave the following results: Moisture and transverse dimensional changes were generally sinusoidal. Moisture and dimensional amplitude increased with increasing cyclic period but all were lower for thicker specimens. The amplitude ratio of condition A to condition B ranged from 1.0 to 1.6 with the maximum value of 1.57 occurring at the shortest cyclic period, not as much as expected. T/R increased as cyclic period increased or specimen thickness decreased. T/R from condition B was weaker than that from condition A. Sorption and swelling hysteresis existed in both conditions. Sorption hysteresis was negatively related to cyclic period but in positive correlation with specimen thickness. Sorption hysteresis was found more obvious in condition B, while moisture sorption coefficient and humidity expansion coefficient showed the opposite results.

A comparison of CPP analysis among breathiness ranks (기식 등급에 따른 CPP (Cepstral Peak Prominence) 분석 비교)

  • Kang, Youngae;Koo, Bonseok;Jo, Cheolwoo
    • Phonetics and Speech Sciences
    • /
    • v.7 no.1
    • /
    • pp.21-26
    • /
    • 2015
  • The aim of this study is to synthesize pathological breathy voice and to make a cepstral peak prominence (CPP) table following breathiness ranks by cepstral analysis to supplement reliability of the perceptual auditory judgment task. KlattGrid synthesizer included in Praat was used. Synthesis parameters consist of two groups, i.e., constants and variables. Constant parameters are pitch, amplitude, flutter, open phase, oral formant and bandwidth. Variable parameters are breathiness (BR), aspiration amplitude (AH), and spectral tilt (TL). Five hundred sixty samples of synthetic breathy vowel /a/ for male were created. Three raters participated in ranking of the breathiness. 217 were proved to be inadequate samples from perceptual judgment and cepstral analysis. Finally, 343 samples were selected. These CPP values and other related parameters from cepstral analysis are classified under four breathiness ranks (B0~B3). The mean and standard deviation of CPP is $16.10{\pm}1.15$ dB(B0), $13.68{\pm}1.34$ dB(B1), $10.97{\pm}1.41$ dB(B2), and $3.03{\pm}4.07$ dB(B3). The value of CPP decreases toward the severe group of breathiness because there is a lot of noise and a small quantity of harmonics.

Development of Drilling Center Column made of Epoxy-granite Material and Experimental Study on it's Structural Characteristics (드릴링 센타용 애폭시-그래나이트재 컬럼의 개발과 구조물 특성 실험)

  • Won, S.T.;Kim, J.H.;Lee, H.W.;Maeng, H.Y.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.1
    • /
    • pp.87-96
    • /
    • 1995
  • A new fungivle material named Epoxy-Granite composite is applied to the column structure of drilling center in order to investigate the advanced dynamic charateristics comparing with a conventional cast iron material. The dimensions of new column structure are adjusted to keep the same stiffness (EI value) and the manufacturing conditions are formulated based on the preceeding research experience about the development of Epoxy-Granite structural material. The two kinds of experiments are set up, one of which is for the measurement of natural mode and frequency using experimental modal analysis, and the other one is for the measurement of vibration amplitude during idling operation of a machine tool. The comparison of maximum accelerance values at each natural frequency of bending mode shows a Epoxy-Granite column have larger modal damping ratios(over 2times) than a cast iron column. The vibration amplitude of Epoxy-Granite column measrued on the bed, motor base, and top of column are also much smaller (up to 12%) than the case of cast iron column. It is therefore confirmed that a Epoxy-Granite material exhibits a good anti- vibrational propderty even if it is used under the actual operational environments of machine tool as a practical structural element.

  • PDF

ANALYSIS AND INTERCOMPARISON OF VARIOUS GLOBAL EVAPORATION PRODUCTS

  • School of Marine Science and Technology, Tokai University, Tsuyoshi Watabe;School of Marine Science and Technology, Tokai University, Masahisa Kubota
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.285-288
    • /
    • 2008
  • We analyzed evaporation data in the Japanese Ocean Flux Data Sets with Use of Remote Sensing Observations (J-OFURO) Ver.2. There exists huge evaporation in Gulf Stream, Kuroshio Extension, the ocean dessert and the southern part of the Indian Ocean. The temporal variation of evaporation is overwhelmingly large, of which the standard deviation is more than 120(mm), in the Kuroshio Extension region. Also, the result of harmonic analysis gives that this large variation is closely related to annual variation. In addition, the first EOF mode shows long-term variation showing the maximum amplitude between 1992 and 1994 and remarkable decrease after 1994, and large amplitude in the equatorial region and northeast of Australia. The second and third modes were strongly influenced by El Nino. Moreover, we compared J-OFURO2 evaporation product with other products. We used six kinds of data sets (HOAPS3 and GSSTF2 of satellite data, NRA1, NRA2, ERA40 and JRA25 of reanalysis data) for comparison. Most products show underestimation in the most regions, in particular, in the northern North Pacific, mid-latitudes of the eastern South Pacific, and high-latitudes of the South Pacific compared with J-OFUR02. On the other hand, JRA25 and NRA2 show large overestimation in the equatorial regions. RMS difference between NRA2 and J-OFURO2 in the Kuroshio Extension was significantly large, more than 120(mm).

  • PDF

Power System Harmonic Estimation Based on Park Transform

  • Chen, Ya;Ji, Tianyao;Li, Mengshi;Wu, Qinghua;Wang, Xuejian
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.560-574
    • /
    • 2016
  • This paper presents a novel method for power system harmonic estimation based on the Park transform. The proposed method firstly extends the signal to a group of three-phase signals in a-b-c coordinate. Then, a linear fitting based method is adopted to estimate the fundamental frequency. Afterwards, the Park transform is utilized to convert the three-phase signals from a-b-c coordinate to d-q-0 coordinate. Finally, the amplitude and phase of a harmonic component of interest can be calculated using the d-axis and q-axis components obtained. Simulation studies have been conducted using matrix laboratory (MATLAB) and power system computer aided design/electromagnetic transients including direct current (PSCAD/EMTDC). Simulation studies in MATLAB have considered three scenarios, i.e., no-frequency-deviation scenario, frequency-deviation scenario and the scenario in the presence of inter-harminics. The results have demonstrated that the proposed method achieves very high accuracy in frequency, phase and amplitude estimation under noisy conditions, and suffers little influence of the inter-harmonics. Moreover, comparison studies have proved that the proposed method is superior to FFT and Interpolated FFT with the Hanning Window (IpFFTHW). Finally, a popular case in PSCAD/EMTDC has been employed to further verify the effectiveness of the proposed method.

Stuctural Characteristics on Drilling Center Column made of Epoxy-granite Material (드릴링 센타용 에폭시-그래나이트재 컬럼의 구조물 특성 연구)

  • 원시태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.03a
    • /
    • pp.158-165
    • /
    • 1995
  • A new fungible materal named Epoxy-Granite composite is applied to the column structure of drilling center in order to investigate the advanced dynamic chatateristics comparing with a conventional cast iron material. The dimensions of new colum structure are adjusted to keep the same stiffness (El value) and the manufacturing conditions are formulated based on the preceeding research experience about the development of Epoxy-Granite structural material. The two kinds of experiments are set up. one of which is for the measurement of natural mode and frequency using experimental modal analysis and the other one is for the measurement of vibration amplitude during idling operation of a machine fool. The comparison of maximum, accelerance values at each natural frequency of bending mode shows a Epoxy-Granite column have larger modal damping ratios(over 2times) than a cast iron column. The vibration amplitude of Epoxy-Granite column measued on the bed motor base and top of column are also much smaller (up to 12%) than the case of cast iron column. It is therefore confirmed that a Epoxy-Granite materal exhibits a good anti-vibrational property even if it is used under the actual operational environments of machine eool as a practical structural element.

  • PDF