• Title/Summary/Keyword: amplitude difference

Search Result 651, Processing Time 0.025 seconds

Defect Evaluation of Weld Zone in Rails Using Attractor and Distance Amplitude Characteristics Curve (레일 용접부의 결함 검출을 위한 어트랙터의 구성 및 해석에 관한 연구)

  • 윤인식;고준빈;박성두
    • Journal of Welding and Joining
    • /
    • v.18 no.5
    • /
    • pp.77-83
    • /
    • 2000
  • This study proposes the analysis and evaluation method of time series ultrasonic signal using the attractor analysis. Features extracted from time series signal analyze quantitatively characteristics of weld defects. For this purpose, analysis objective in this study is fractal dimension and attractor quadrant feature. Trajectory changes in the attractor indicated a substantial difference in fractal characteristics resulting from distance shifts such as parts of head and flange even though the types of defects are identified. These difference in characteristics of weld defects enables the evaluation of unique characteristics of defects in the weld zone. In quantitative fractal feature extraction, feature values of 3.848 in the case of part of head(crack) and 4.102 in the case of part of web(side hole) and 3.711 in the case of part of flange(crack) were proposed on the basis of fractal dimensions. Proposed attractor analysis and DAC in this study can enhance the precision rate of ultrasonic evaluation for defect signals of rail weld zone such as side hole and crack.

  • PDF

Effects of Task and Part on Tremor Characteristics in Patients with Essential Tremor (본태성 진전 환자의 진전특성에 대한 수행과제 및 부위의 영향)

  • Heo, J.H.;Kim, J.W.;Kwon, Y.R.;Eom, Gwang-Moon;Kwon, D.Y.;Lee, C.N.;Park, K.W.;Manto, M.
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.15-20
    • /
    • 2016
  • Essential tremor is a neurological disorder with a tremor of the arms and hands. It is well known that essential tremor is characterized by the postural tremor and the action tremor. There has been no report on the quantitative difference in the characteristics of two tremor types. The purpose of this study was to investigate the possible difference in tremor characteristics of postural and action tremors. Seventeen patients with essential tremor ($68.9{\pm}7.9years$, 7 men, 10 women) participated in this study. Patients performed the tasks of postural maintenance (arms outstretched) and daily actions (spiral drawing). Three-axes (pitch, roll and yaw) gyro sensors were attached on index finger, back of hand and forearm, from which the segment and the joint angular velocities were calculated. Outcome measure was the tremor amplitude defined as the root-mean-square mean of the vector-sum angular velocity at segments and joints. Two-way ANOVA showed that task and joint had main factor on the tremor amplitude (p < 0.05). Post-hoc analysis revealed that tremor amplitude at the metacarpo-phalangeal joint was not affected by task (p > 0.05). However, tremor amplitude at the wrist joint differed among the tasks (p < 0.05), and it was greater in the action tasks than in postural task. Tremor was greater at finger segments than at hand and forearm and it increased in action tasks. The results of this study would be helpful for the understanding and task-specific treatments of the essential tremor.

The Effects of Upper Limb Neuro Dynamic Treatment on the Pain, Grip Strength and Nerve Conduction Velocity of Patients with Carpal Tunnel Syndrome (상지역동학 치료가 수근관 증후군 환자의 통증, 악력, 신경전도속도에 미치는 효과)

  • Yu, Seong-Hun;Park, Sung-Doo;Kim, Tae-Won;Song, Hyun-Seung;Kim, Jin-Young
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.49-56
    • /
    • 2012
  • Background: When applying the upper limb neurodynamic treatment ULNT1 and upper limb neurodynamic treatment ULNT2, The object of this study evaluates the pain and grip strength, nerve conduction velocity and tries to present the treatment that is effective in the carpal tunnel syndrome through the comparison of effect between tests. Methods: The ULNT1 (n=10) and ULNT2 (n=10) was applied to the carpal tunnel syndrome in patient of 20 subject for 10 time 5 set during 4 weeks. Both groups received conventional physical therapy (hot pack with 30 minutes and ICT with 15 minutes and ultra sound with 15 minutes). Results: The ULNT1 showed the difference which the result of this study significantly in the median nerve motor latency, median nerve motor amplitude, median nerve sensory latency, median nerve sensory amplitude, grip strength and pain. ULNT2 showed the difference significantly in median nerve motor latency, median nerve motor amplitude, median nerve sensory latency, median nerve sensory amplitude and pain. Conclusions: If it implements by applying the traditional physiotherapy and ULNT1 and ULNT2 to the carpal tunnel syndrome subjects according to the subject state and function, the remedial value can be more enhanced.

  • PDF

pH-mediated Regulation of Pacemaker Activity in Cultured Interstitial Cells of Cajal

  • Kim, Byung-Joo;Lee, Jae-Hwa;So, In-Suk;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.1
    • /
    • pp.7-11
    • /
    • 2006
  • Interstitial cells of Cajal (ICCs) are pacemakers in gastrointestinal tracts, regulating rhythmicity by activating nonselective cation channels (NSCCs). In the present study, we investigated the general characteristics and pH-mediated regulation of pacemaker activity in cultured interstitial cells of Cajal. Under voltage clamp mode and at the holding potential of -60 mV, the I-V relationships and difference current showed that there was no reversal potential and voltage-independent inward current. Also, when the holding potentials were changed from +20 mV to -80 mV with intervals of 20 mV, there was little difference in inward current. In pacemaker activity, the resting membrane potential (RMP) was depolarized (In pH 5.5, $23{\pm}1.5$ mV depolarized) and the amplitude was decreased by a decrease of the extracellular pH. However, in case of increase of extracellular pH, the RMP was slightly hyperpolarized and the amplitude was decreased a little. The melastatin type transient receptor potential (TRPM) channel 7 has been suggested to be required for intestinal pacemaking activity. TRPM7 produced large outward currents and small inward currents by voltage ramps, ranging from +100 to -100 mV from a holding potential of -60 mV. The inward current of TRPM7 was dramatically increased by a decrease in the extracellular pH. At pH 4.0, the average inward current amplitude measured at -100 mV was increased by about 7 fold, compared with the current amplitude at pH 7.4. Changes in the outward current (measured at +100 mV) were much smaller than those of the inward current. These results indicate that the resting membrane potential of pacemaking activity might be depolarized by external acidic pH through TRPM7 that is required for intestinal pacemaking activity.

Measurement of the Ultrasonic Longitudinal Wave Velocities in Thin Plate (얇은 판재에서의 초음파 종파속도 측정)

  • 안봉영;이승석;이재옥
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2181-2188
    • /
    • 1991
  • The ultrasonic longitudinal wave velocities propagating normal to the surface in thin plates were measured with the amplitude spectrum method. The accuracy of the velocity measurement in o.5mm thick plates was 0.1%. In 4.239mm thick plate the phase velocities at the frequency band of 5MHz-15MHz were measured with the phase spectrum method and the amplitude spectrum method, and the velocity difference between two methods was less than 20m/s.

Micro Ultrasonic Elliptical Vibration Cutting (I) The Generation of a Elliptical Vibration Cutting Motion for Micro Ultrasonic Machining (미세 초음파 타원궤적 진동절삭 (I) 미세 초음파 가공을 위한 타원 절삭경로 생성)

  • Loh Byung-Gook;Kim Gi Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.190-197
    • /
    • 2005
  • For precise micro-grooving and surface machining, a mechanism for creating elliptical vibration cutting (EVC) motion is proposed which uses two parallel piezoelectric actuators. And based on its kinematical analysis, variations of EVC path are investigated as a function of dimensional changes in the mechanism, phase difference and amplitude of excitation sinusoidal voltages. Using the proposed PZT mechanism, various types of two dimensional EVC paths including one dimensional vibration cutting path along the cutting direction and thrust direction can be easily obtained by changing the phase lag, the amplitude of the piezoelectric actuators, and the dimension of the mechanism.

Influence of Aging on Surface EMG Signals Generated Under Sustained Fixed Load Contraction (고정 부하 수축시 기록한 표면근전도 신호에 대한 노화의 영향)

  • Lee, Jin;Kim, Sung-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1497-1505
    • /
    • 2010
  • The present study was performed to investigate the effect of aging on muscular activity of older subjects under the condition of fixed load muscle contraction. SEMG signals were recorded from old (46 women) and young (45 women) groups performing sustained isometric elbow flexion contraction with a fixed load during 30 seconds. Linear regression and mean square error (MSE) analysis with four characteristic variables (ARV, RMS, MDF, MNF) were used to compare the age-related difference (of local muscle fatigue and fluctuation of the amplitude and frequency) in the SEMG signal. The main results can be summarized as follows: During sustained muscle contraction with a fixed load: i) the MSE values of amplitude (ARV, RMS) and frequency (MDF, MNF) variables were more than 30% higher for the young than for the old adults; ii) the measures of local muscle fatigue (slope of the MDF and MNF) indicated greater fatigue in the old; and iii) the rate of increase of the SEMG amplitude was higher for the young than the old.

An Analysis of Phonetic Parameters for Individual Speakers (개별화자 음성의 특징 파라미터 분석)

  • Ko, Do-Heung
    • Speech Sciences
    • /
    • v.7 no.2
    • /
    • pp.177-189
    • /
    • 2000
  • This paper investigates how individual speakers' speech can be distinguished using acoustic parameters such as amplitude, pitch, and formant frequencies. Word samples from fifteen male speakers in their 20's in three different regions were recorded in two different modes (i.e., casual and clear speech) in quiet settings, and were analyzed with a Praat macro scrip. In order to determine individual speakers' acoustical values, the total duration of voicing segments was measured in five different timepoints. Results showed that a high correlation coefficient between $F_1\;and\;F_2$ in formant frequency was found among the speakers although there was little correlation coefficient between amplitude and pitch. Statistical grouping shows that individual speakers' voices were not reflected in regional dialects for both casual and clear speech. In addition, the difference of maximum and minimum in amplitude was about 10 dB which indicates a perceptually audible degree. These acoustic data can give some meaningful guidelines for implementing algorithms of speaker identification and speaker verification.

  • PDF

A Displacement Analysis of 2-Dimensional Tool Vibrator (2차원 공구진동기구의 변위 해석)

  • 손성민;임한석;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.898-901
    • /
    • 2000
  • In this paper, the theoretical tool displacement and surface roughness are analyzed based on the tool locus of a 2-dimensional tool vibrator. At first, the effects assuming no structural deformation of such variables as frequency, amplitude and phase difference that determine tool loci are simulated. The results show that larger amplitude and/or higher frequency makes better surface. However, a real tool vibrator has the structural deformation, much or less, depending on the excitation frequency. Applying FEM analysis to the deformation of a designed 2D tool vibrator according to the excitation, it has been proved that in this case the displacement is 5${\mu}{\textrm}{m}$ at 1KHz and almost 0 at 20KHz even under the same excitation amplitude.

  • PDF

A Study on Dynamic Behavior of a Rotor-Bearing System Under External Disturbances (외란을 받는 축-베어링 시스템의 동적 거동에 대한 연구)

  • Rho, Byoung-Hoo;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.18 no.1
    • /
    • pp.9-15
    • /
    • 2002
  • The nonlinear vibration characteristics of hydrodynamic journal bearings with a circumferential groove we analyzed numerically when the external sinusoidal disturbances are given to the rotor-bearing system continuously. Furthermore, a cavitation algorithm, implementing the Jakobsson-Floberg-Olsson boundary condition, is adopted to predict cavitation regions in a fluid film more accurately than the conventional analysis. which uses the Reynolds boundary condition. It is found that the difference between linear and nonlinear analysis is much more remarkable as the amplitude of external disturbance increases, and it depends upon the excitation frequency of the external disturbance. It is also shown that the cavity region in the fluid film increases as the amplitude or excitation frequency of the external disturbance increases. The whirling center of the steady state orbit moves closer to the bearing center as the amplitude or excitation frequency of the external disturbance increases.