• Title/Summary/Keyword: amplitude control

Search Result 966, Processing Time 0.029 seconds

High-Resolution Seismic Reflection Profiling on Land with Hydrophones Employed in the Stream-Water Driven Trench (하천수유입과 하이드로폰을 이용한 육상 고분해능 탄성파반사법탐사)

  • Kim Ji-Soo;Han Su-Hyung;Kim Hak-Soo;Choi Won-Suk;Jung Chang-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.4
    • /
    • pp.133-144
    • /
    • 2001
  • An effective seismic reflection technique for mapping the cavities and bedrock surface in carbonate rocks is described. The high resolution seismic reflection images were successfully registered by using the hydrophones employed in the stream-water driven trench, and were effectively focused by applying optimal data processing sequences. The strategy included enhancement of the signal interfered with the large-amplitude scattering noise, through pre- and post stack processing such as time-variant filtering, bad-trace editing, residual statics, velocity analysis, and careful muting after NMO (normal moveout) correction. The major reflections including the bedrock surface were mapped with the desired resolution and were correlated to the seismic crosshole tomographic data. Shallow major reflectors could be identified and analyzed on the AGC (auto gain control)-applied field records. Three subhorizontal layers were identified with their distinct velocities; overburden (<3000 m/s), sediments (3000-4000 m/s), limestone bedrock (>4000 m/s). Taking into account of no diffraction effects in the field records, gravel-rich overburdens and sediments are considered to be well sorted. Based on the images mapped consistently on the whole survey line and seismic velocity increasing with depth, this area probably lacks in sizable cavities (if any, no air-filled cavities).

  • PDF

Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests (풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석)

  • Lee, Dooyoung;Goo, Jaeryang;Park, Sooman;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • In this paper, the wind tunnel test for the measurement of aerodynamic characteristics of transmission conductors with asymmetric sections is described. A single conductor model and bundled conductor models with ice accreted shapes are tested both in steady and turbulent flow, and the aerodynamic coefficients are acquired. Transmission conductor galloping is a kind of wind-induced vibration which is characterized by primarily vertical oscillation with a very low frequency and a high amplitude. It is well known that transmission conductor galloping is generally caused by moderately strong, steady winds when a transmission conductor has an asymmetric cross-section shaped by accreted ice. Galloping should be considered from the design stage of overhead lines because it can cause severe wear and fatigue damage to attachments as well as transmission conductors. It is reported that there have been normally 20 events of galloping per year in Korea, which may be followed by serious consequences in the electric power system. Therefore, this research is performed to measure aerodynamic characteristics of ice accreted transmission conductors to understand and control transmission conductor galloping so that it would help to prevent unexpected failures and reduce the maintenance costs caused by galloping.

Development of an Advanced Deformable Phantom to Analyze Dose Differences due to Respiratory Motion

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Koo, Hyun-Jae;Cho, Min-Seok;Ha, Jin-Suk;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • The difference between three-dimensional (3D) and four-dimensional (4D) dose could be affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom that can independently control each factor is required. The purpose of this study is to develop a deformable lung phantom with the above attributes and evaluate the characteristics. A phantom was designed to simulate diaphragm motion with amplitude in the range 1~7 cm and period up to ${\geq}2s$ of regular breathing. To simulate different tumors sizes, custom molds were created using a 3D printer and filled with liquid silicone. The accuracy of the phantom diaphragm motion was assessed by comparing measured motion with predicted motion. Because the phantom diaphragm motion is not identical to the tumor motion, the correlation between the diaphragm and tumor motions was calculated by a curve fitting method to emulate user-intended tumor motion. Tumors of different sizes were located at same position, and tumor set-up positions were evaluated. The accuracy of phantom diaphragm motion was better than 1 mm. The diaphragm-tumor correlation showed that the tumor motion in the superior-inferior direction increased with increasing diaphragm motion. The tumor motion was larger in the $10cm^3$ tumor than in the $90cm^3$ tumor. The range of difference between the tumor set-up positions was 0 to 0.45 cm. This phantom showed independently adjusting factors such as tumor size and motion to facilitate quantitative analysis of the dosimetric impact of respiratory motion according to these factors.

Modulation of $Ca^{2+}-Activated$ Potassium Channels by cGMP-Dependent Signal Transduction Mechanism in Cerebral Arterial Smooth Muscle Cell of the Rabbit

  • Han, Jin;Kim, Na-Ri;Lee, Kwang-Bok;Kim, Eui-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.6
    • /
    • pp.445-453
    • /
    • 2000
  • The present investigation tested the hypothesis that the activation of protein kinase G (PKG) leads to a phosphorylation of $Ca^{2+}-activated$ potassium channel $(K_{Ca}\;channel)$ and is involved in the activation of $K_{Ca}$ channel activity in cerebral arterial smooth muscle cells of the rabbit. Single-channel currents were recorded in cell-attached and inside-out patch configurations of patch-clamp techniques. Both molsidomine derivative 3-morpholinosydnonimine-N-ethylcarbamide $(SIN-1,\;50\;{\mu}M)$ and 8-(4-Chlorophenylthio)-guanosine-3',5'-cyclic monophosphate $(8-pCPT-cGMP,\;100\;{\mu}M),$ a membrane-permeable analogue of cGMP, increased the $K_{Ca}$ channel activity in the cell-attached patch configuration, and the effect was removed upon washout of the drugs. In inside-out patches, single-channel current amplitude was not changed by SIN-1 and 8-pCPT-cGMP. Application of ATP $(100\;{\mu}M),$ cGMP $(100\;{\mu}M),$ ATP+cGMP $(100\;{\mu}M\;each),$ PKG $(5\;U/{\mu}l),$ ATP $(100\;{\mu}M)+PKG\;(5\;U/{\mu}l),$ or cGMP $(100\;{\mu}M)+PKG\;(5\;U/{\mu}l)$ did not increase the channel activity. ATP $(100\;{\mu}M)+cGMP\;(100\;{\mu}M)+PKG\;(5\;U/{\mu}l)$ added directly to the intracellular phase of inside-out patches increased the channel activity with no changes in the conductance. The heat-inactivated PKG had no effect on the channel activity, and the effect of PKG was inhibited by 8-(4-Chlorophenylthio)-guanosine-3',5'-cyclic monophosphate, Rp-isomer $(Rp-pCPT-cGMP,\;100\;{\mu}M),$ a potent inhibitor of PKG or protein phosphatase 2A (PP2A, 1 U/ml). In the presence of okadaic acid (OA, 5 nM), PP2A had no effect on the channel activity. The $K_{Ca}$ channel activity spontaneously decayed to the control level upon washout of ATP, cGMP and PKG, and this was prevented by OA (5 nM) in the medium. These results suggest that the PKG-mediated phosphorylations of $K_{Ca}$ channels, or some associated proteins in the membrane patch increase the activity of the $K_{Ca}$ channel, and the activation may be associated with the vasodilating action.

  • PDF

Ginsenoside $Rg_3$ Increases the ATP-sensitive $K^+$ Channel Activity in the Smooth Muscle of the Rabbit Coronary Artery

  • Chung Induk;Lee Jeong-Sun
    • Journal of Ginseng Research
    • /
    • v.23 no.4
    • /
    • pp.235-238
    • /
    • 1999
  • ATP-sensitive $K^+$ channels $(K_{ATP})$ are expressed in vascular smooth muscle cells, skeletal muscle cells, pancreatic ${\beta}$ cells, neurons and epithelial cells. $K_{ATP}$ contributes to regulate membrane potential to control vascular tone, to protect myocardial ischemia, and to regulate insulin secretion in pancreatic ${\beta}$ cells. We previously demonstrated that ginseng saponins and ginsenoside $Rg_3$ activated maxi $Ca^{2+}-activated\;K^+$ channel, and this might cause vasodilation. Because $K_{ATP}$ plays an important roles to regulate the resting membrane potential in vascular smooth muscle cells, we investigated whether ginsenoside $Rg_3$ produces vasodilation by activating $K_{ATP}$ We showed in this study that $K_{ATP}$ is expressed in rabbit coronary artery smooth muscle cells. $K_{ATP}$ was inwardly rectifying and was inhibited by intemal application of ATP. Micromolar minoxidil activated, but glyburide inhibited the activity of $K_{ATP}$ Ginsenoside $Rg_3$ relieved inactivaiton of whole-cell $K_{ATP}$ current without affecting the peak amplitude of $K_{ATP}$ currents presumably due to more opening of the channels.

  • PDF

A Nulling Anti-Jamming Scheme for the Polyphase Filter Bank-Based Satellite Repeat System (다상 필터 뱅크 기반의 위성 중계시스템을 위한 항재밍 기법의 연구)

  • Oh, Jin-O;Im, Sung-Bin;Ko, Hyun-Suk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.7
    • /
    • pp.39-47
    • /
    • 2012
  • The combination of the broadband property and the wide area coverage of satellite communications enables high speed transmission. Every user in the region under the satellite beam coverage can tranceiver and one can simultaneously communicate with multiple users. For these reasons, it is one of commendable telecommunication networks for information transfer. Since the satellite communications use open channels, it is likely to cause jamming with unwanted interference signals. In the thesis, APSK (Amplitude Phase Shift Keying) is employed, which is recommended for DVB-S2 due to high-speed transmission and excellent bandwidth efficiency. For obtaining reliable communication under the jamming environments, the communication satellite transponder rests on the polyphase filter bank structure, which enables switching among the subchannels and gain control on each subchannel, resulting in effectively eliminating jamming. Furthermore, the nulling scheme, one of the various anti-jamming approaches, is investigated, in which unwanted jamming signals are eliminated in the frequency domain after passing through the analysis part of the polyphase filter bank. The performance of the nulling scheme is evaluated for tone jamming and partial band jamming in terms of BER and EVM. The simulation results indicate that the nulling scheme improve the BER and EVM performance over the case without any anti-jamming approach.

Analysis of Performance of Digital Retrodirective Antenna Technology in High-Speed Rail (고속 철도 환경에서의 디지털 역지향성 안테나 기술 성능 분석)

  • Bok, Junyeong;Lee, Seung Hwan;Shin, Dong Jin;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.11
    • /
    • pp.1264-1271
    • /
    • 2012
  • Fast tracking is important for high-speed data transmission in high-speed mobile environment such as high speed rail and vehicular. Digital retrodirective array antenna is possible to do automatically beam tracking because it can control the phase information of the output signal toward opposite direction to input signal without no a priori knowledge of the arrival direction. Also, Digital retrodirective array antennas has merit that it is easy to upgrade and modify compare with analogue retrodirective array antennas. In this paper, we analyze the BER performance of digital retrodirective array antenna under AWGN environment and multipath signal. Simulation results show correct phase estimation and conjugation of retrodirective array antenna by using phase detector block. Also, phase conjugation technique has better BER performance about 1 dB at source than that of without phase conjugation when phase lag is $15^{\circ}$ in AWGN environment. This paper also discusses effect of the presence of multipath signal. Phase and amplitude error about direction of direct signal occurs when retrodirective array system is affected by interference and multipath signal in the presence of multipath signal.

Design and manufacture of mini loop coil probe style magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 초미니 Loop-코일프로브 삽입형 자기치료기의 설계 및 제작)

  • Kim, Whi-Young;Choi, Jin-Young;Park, Sung-Jun;Kim, Hee-Je
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.2 no.1
    • /
    • pp.153-169
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Design and Implementation of High Efficiency Transceiver Module for Active Phased Arrays System of IMT-Advanced (IMT-Advanced 능동위상배열 시스템용 고효율 송수신 모듈 설계 및 구현)

  • Lee, Suk-Hui;Jang, Hong-Ju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.26-36
    • /
    • 2014
  • The needs of active phased arrays antenna system is getting more increased for IMT-Advanced system efficiency. The active phased array structure consists of lots of small transceivers and radiation elements to increase system efficiency. The minimized module of high efficiency transceiver is key for system implementation. The power amplifier of transmitter decides efficiency of base-station. In this paper, we design and implement minimized module of high efficiency transceiver for IMT-Advanced active phased array system. The temperature compensation circuit of transceiver reduces gain error and the analog pre-distorter of linearizer reduces implemented size. For minimal size and high efficiency, the implented power amplifier consist of GaN MMIC Doherty structure. The size of implemented module is $40mm{\times}90mm{\times}50mm$ and output power is 47.65 dBm at LTE band 7. The efficiency of power amplifier is 40.7% efficiency and ACLR compensation of linearizer is above 12dB at operating power level, 37dBm. The noise figure of transceiver is under 1.28 dB and amplitude error and phase error on 6 bit control is 0.38 dB and 2.77 degree respectively.

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.