• 제목/요약/키워드: ammonia removal

검색결과 563건 처리시간 0.028초

주정중의 Ammonia 제거에 관한 지견 (Studies on the Removal of Ammonia in Alcohol)

  • 심길순
    • 약학회지
    • /
    • 제8권3호
    • /
    • pp.74-75
    • /
    • 1964
  • In view of the fact that the technical grade alcohol sold in Korea contains considerable amount of ammonia (average 10 ppm), the author has investigated a new method of removal of ammonia by the addition of dl-tartaric acid. It was found that the ammonia contained in sample alcohol was removed completely, by the addition of dl-tartaric acid, to form ammonium bitartrate.

  • PDF

Modified Ammonia Removal Model Based on Equilibrium and Mass Transfer Principles

  • Shanableh, A.;Imteaz, M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권7호
    • /
    • pp.1920-1926
    • /
    • 2010
  • Yoon et $al.^1$ presented an approximate mathmatical model to describe ammonia removal from an experimental batch reactor system with gaseous headspace. The development of the model was initially based on assuming instantaneous equilibrium between ammonia in the aqueous and gas phases. In the model, a "saturation factor, $\beta$" was defined as a constant and used to check whether the equilibrium assumption was appropriate. The authors used the trends established by the estimated $\beta$ values to conclude that the equilibrium assumption was not valid. The authors presented valuable experimental results obtained using a carefully designed system and the model used to analyze the results accounted for the following effects: speciation of ammonia between $NH_3$ and $NH^+_4$ as a function of pH; temperature dependence of the reactions constants; and air flow rate. In this article, an alternative model based on the exact solution of the governing mass-balance differential equations was developed and used to describe ammonia removal without relying on the use of the saturation factor. The modified model was also extended to mathematically describe the pH dependence of the ammonia removal rate, in addition to accounting for the speciation of ammonia, temperature dependence of reactions constants, and air flow rate. The modified model was used to extend the analysis of the original experimental data presented by Yoon et $al.^1$ and the results matched the theory in an excellent manner.

Ammonia Removal Model Based on the Equilibrium and Mass Transfer Principles

  • Yoon, Hyein;Lim, Ji-Hye;Chung, Hyung-Keun
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권3호
    • /
    • pp.555-561
    • /
    • 2008
  • In air stripping of ammonia from the aqueous solution, a new removal model was presented considering the equilibrium principles for the ammonia in aqueous solution and between the aqueous and air phase. The effects of pH, temperature and airflow rate on the ammonia removal were evaluated with the model. In addition, the saturation degree of ammonia in air was defined and used to evaluate the effect of each experimental factor on the removal rate. As pH (8.9 to 11.9) or temperature (20 to 50 oC) was increased, the overall removal rate constants in all cases were appeared to be increased. Our presented model shows that the degrees of saturation were about the same (0.45) in all cases when the airflow condition remains the same. This result indicates that the effect of pH and temperature were directly taken into consideration in the model equation. As the airflow increases, the overall removal rate constants were increased in all cases as expected. However, the saturation degree was exponentially decreased with increasing the airflow rate in the air phase (or above-surface) aeration. In the subsurface aeration the saturation degree remains a constant value of 0.65 even though the airflow rate was increased. These results indicate that the degree of saturation is affected mainly by the turbulence of the aqueous solution and remains the same above a certain airflow rate.

축산농가에서 목초액을 이용한 암모니아 가스의 제거 특성에 관한 연구 (Ammonia Removal Characteristics by Pyroligneous Liquid at Livestock Farmhouse)

  • 박정호;전기일;정창훈
    • 한국환경과학회지
    • /
    • 제12권12호
    • /
    • pp.1309-1313
    • /
    • 2003
  • This study was carried out to obtain the optimal ammonia removal efficiency using pyroligenous liquid for the economical and environment-friendly odor removal at a petty livestock farmhouse. The ammonia removal efficiencies were evaluated due to changing dilution rates(${\times}$10, ${\times}$20, ${\times}$30, ${\times}$50 and ${\times}$100 times) and different spray amounts(10$m\ell$ and 20$m\ell$) of pyroligenous liquid. The wet scrubber device was used to remove odor in closed-type livestock farmhouse. According to dilution rate of the pyroligenous liquid, the optimum rate was 20 times and the removal efficiency increased by decreasing dilution rates. In the case of spray amounts with the optimum dilution, the amount was 20 me and the removal efficiency increased by increasing spray amount. Also, the removal efficiency by using wet deodorizing device was 83.0-97.0% with 20 times diluted liquid.

폐수의 감압 암모니아 탈기에 관한 연구 (A Study on the Decompressed Ammonia Stripping from Ammonia Contained Wastewater)

  • 신대윤;오유경
    • 한국환경보건학회지
    • /
    • 제27권1호
    • /
    • pp.93-99
    • /
    • 2001
  • This study aims at finding out pertinent reaction conditions for treating high concentration ammonia contained in N-chemical factory wastewater with decompressed ammonia stripping method that was designed. And it also tries to investigate adsorption capability of removed ammonia to soil. The results from experiments are as follows ; 1. The removal rate of N $H_3$-N of synthetic wastewater was under 85% at pH 10 with decompressed ammonia stripping method. The reaction time in pressure 360 mmHg at pH 11 and 12 was shorter than in 460 mmHg, and the removal rate of N $H_3$-N with decompressed ammonia stripping method at 9$0^{\circ}C$ was 11~15% higher than air stripping 2. The optimum conditions for decompressed ammonia stripping with synthetic sample were shown as pH 12, temperature 9$0^{\circ}C$, internal reaction pressure 460 mmHg and reaction time 50 minutes. These conditions were applied to treat the wastewater containing organic-N 290.5mg/$\ell$, N $H_3$-N 168.9mg/$\ell$, N $O_2$-N 23.2mg/$\ell$, N $O_3$-N 252.4mg/$\ell$, T-N 735mg/$\ell$. Organic-N turned out to be removed 60%, the removal rate of N $H_3$-N IS 94%, T-N is 50%. But N $O_2$-N and N $O_3$-N were increased with 7.8% and 14.9% respectively. 3. The CO $D_{Sr}$ removal rate in decompressed ammonia stripping reaction was 42% and S $O_4$$^{2-}$ was removed 8.2%. It was turned out caused with higher pH and thermolysis. 4. In soil adsorption of ammonia desorbed from the decompressed stripping process of wastewater, the recovery rate was 76% in wet soil.

  • PDF

고정화 생물 반응기에 의한 암모니아 제거 (Removal of ammonia by packed bed bioreactor using immobilized nitrifiers)

  • 김병진;이경범;서근학
    • 한국환경과학회지
    • /
    • 제8권2호
    • /
    • pp.177-182
    • /
    • 1999
  • Nitrifier consortium entrapped in Ca-alginate bead were packed into aerated packed bed bioreactor and non aerated packed bed bioreactor and the performances of two bioreactors were evaluated for the removal of ammonia nitrogen from synthetic aquaculture water. Total ammonia nitrogen(TAN) removal rate was decrease in aerated packed bed bioreactor below 0.3hr of hydraulic residence time(HRT), but increased in non aerated packed bed bioreactor until 0.5hr of HRT. At HRT of 0.05hr, TAN removal rate of non aerated packed bed bioreactor was about 335g TAN/㎥/day and the optimum ratio of packing height and inside diameter of reactor (H/D) was 4. The performance of two bioreactors indicated that non aerated packed bed bioreactor was better than aerated packed bed bioreactor in ammonia removal from synthetic aquaculture water.

  • PDF

전기투석에 의한 암모니아성질소의 제거 시 운전인자의 영향 (Effects of Operating Parameters on the Removal Performance of Ammonia Nitrogen by Electrodialysis)

  • 윤태경;이강춘;정병길;한영립;성낙창
    • 청정기술
    • /
    • 제17권4호
    • /
    • pp.363-369
    • /
    • 2011
  • 고농도의 암모니아성질소를 함유하는 폐수의 처리에 전기투석공정의 적용성이 실험적으로 평가되었다. 처리 성능은 전기투석공정의 운전인자 중 유입농도, 운전전압, 그리고 유속이 암모니아성질소의 제거효율에 미치는 영향으로 측정되었다. 한계전류밀도는 유입농도와 유입유속이 증가함에 따라 선형적으로 증가하였고, 유입농도에 따라 목표농도에 도달하는 시간은 직선적인 비례관계를 보였다. 상대적으로 큰 암모니아성질소의 이온당량전도도와 이온이동도로 인하여 유입유속의 증가는 제거속도를 지속적으로 증가시켰다. 또한 운전전압의 증가에 따라 제거속도는 증가하였다. 본 연구에 사용된 전기투석모듈에서 고농도의 암모니아성질소를 제거하는 운전조건으로 유입유속은 3.2 L/min, 운전전압은 한계전류밀도에 해당하는 전압의 80~90%가 추천된다.

Performance Evaluation of Anaerobic Bioreactors and Effects of Ammonia on Anaerobic Digestion in Treating Swine Wastewaters

  • Lee, Gook-Hee;Seo, Jun-Won;Kim, Jong-Soo
    • 한국환경농학회지
    • /
    • 제25권3호
    • /
    • pp.195-201
    • /
    • 2006
  • The operational characteristics of anaerobic bioreactors in treating swine wastewater were evaluated upto hydraulic retention time (HRT) of 1 day and organic loading rate (OLR) of $5.1kg-COD/m^3{\cdot}d$ for 200 days. The bioreactors were effective in treating swine wastewaters with COD removal efficiency of $78.9{\sim}81.5%$ and biogas generation of $0.39{\sim}0.59m^3/kg-COD_r$ at OLR of $1.1{\sim}2.2kg-COD/m^3{\cdot}d$. The two-stage ASBF anaerobic bioreactors was effective in treating different characteristics of swine wastewaters since they showed high and stable COD removal efficiency at high OLR due to effective retention of biomass by media and staging. The effects of ammonia on anaerobic digestion were investigated by operating two-stage ASBF reactors using swine wastewaters as influent without and with ammonia removal at HRT of $1{\sim}2$ days and OLR of $2.2{\sim}9.6kg-COD/m^3{\cdot}d$ for 250 days. The COD removal efficiency and biogas generation of two-stage ASBF reactors was decreased by increasing influent ammonia concentrations to 1,580 mg (T-N)/L with increasing OLR to $6.3kg-COD/m^3{\cdot}d$, while those were increased by maintaining influent ammonia concentrations below 340 mg (T-N)/L by MAP precipitation with increasing OLR to $9.6kg-COD/m^3{\cdot}d$. Initial inhibition of ammonia on anaerobic processes was observed at a concentration of 760 mg (T-N)/L and the COD removal efficiency and biogas generation dropped to 1/2 at ammonia concentration ranges of $1,540{\sim}1,870mg$ (T-N)/L. It is essential to remove ammonia in swine wastewaters to an initial inhibition level before anaerobic processes for the effective removal of COD.

소규모 오수처리시스템에서의 제올라이트에 의한 암모니아성 질소 제거(지역환경 \circled3) (Ammonia Removal by Use of Zeolite at Small Wastewater Treatment System)

  • 방천희;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.643-648
    • /
    • 2000
  • The purpose of this study is to remove the ammonia by using the ion exchange effect of natural zeolite (clinoptilolite in this system) and artificial zeolite and remove the organic material by using the Absorbent Biofilter. On the removal of ammonia, natural zeolite is the more effective than artificial zeolite But on the simultaneous removal of ammonia and phosphorus, artificial zeolite is the more effective than natural zeolite.

  • PDF

회전원판을 이용한 해수 순환여과 시스템에서 암모니아 부하율에 따른 암모니아 제거율 (Ammonia removal rate on ammonia loading rates in seawater filtering system using rotating biological contactor (RBC))

  • 손맹현;전임기;조기채;김광수
    • 한국수산과학회지
    • /
    • 제33권4호
    • /
    • pp.367-372
    • /
    • 2000
  • 회전원판식 해수 여과시스템에서 암모니아성 질소 부하율과 수리학적 부하량이 암모니아 제거율에 미치는 영향을 조사하기 위하여 일련의 실험을 실시하였다. 이 실험에서 회전원판 시스템은 폴리비닐필름 원판으로 여과조를 제작하였는데, 여과조의 표면적은 $12m^2$으로 용적은 $0.075m^3$이다. 회전원판식 시스템에서 암모니아성 질소부하율에 따른 암모니아 제거율을 조사하기 위하여 암모니아원으로 염화암모늄을 $10{\~}150 g$ 첨가하였다. 회전원판식 순환여과 사육시스템의 사육수에 암모니아원으로 염화암모늄을 $10{\~}150 g$ 투입하여 사육수의 암모니아 농도 (x: NH_4-N mg/l)에 따라 회전원판 여과조에서의 암모니아 제거에 필요한 시간 (y: hr)을 조사하였으며, 그 관계식은 다음과 같았다. $y=3.51+7.76 lnx (r^2=0.936)$사육수의 암모니아 농도가 2mg/l일 때 회전원판 여과사육 시스템에서 암모니아 제거에 소요되는 시간은 10시간이었으나, 암모니아 농도가 5와 16.5mg/l에서는 각각 16과 27시간이 소요되었다. 따라서 사육수의 암모니아 농도가 높아질수록 암모니아 제거에 소요되는 시간이 감소하는 경향을 나타내었다. 결론적으로 회전원판 여과 사육시스템의 최대 암모니아 제거율은 사육수의 암모니아 농도가 16.5 mg/l까지 상승함에 따라 증가함을 알 수 있었다.

  • PDF