• 제목/요약/키워드: ambient air temperature

검색결과 565건 처리시간 0.027초

외기온 변화에 따른 공기-공기/공기-물 형태로 된 복합형 열펌프 시스템의 성능 특성 분석 (Performance Analysis of Hybrid Heat Pump System of the Air-to-Air/Air-to-Water with the Ambient Temperature)

  • 송현갑
    • Journal of Biosystems Engineering
    • /
    • 제25권4호
    • /
    • pp.273-278
    • /
    • 2000
  • The hybrid heat pump system of the air to air and / or air to water was composed and its COP was analyzed with the ambient temperature on the opened and closed loop system respectively. The results be indicated by the equation(7) that the COP(Coefficient of Performance) of air-source(air to air and / or air-water) heat pump is effected with the ambient air temperature and AVACTHE.(Automatic Variable Area Capillary Type Heat Exchanger) 2. The COP of air-to-water heat pump without AVACTHE decreased in accordance with the ambient temperature decrease, however in case of the heat pump with AVACTHE the COP was maintained at 2.8∼3.0 level when the ambient temperature decrease from -$5^{\circ}C$ to $-11^{\circ}C$. 3. The COP of the air-to-water heat pump operated on the open loop was higher 40∼58% than that of the heat pump operated on the close loop. 4. The lower ambient temperature air effect on the COP of the air-to-air heat pump operated on the semi closed loop could be controlled using the AVACTHE, and at the high ambient air temperature the COP increased using the Bypass circuit.

  • PDF

환경 온도가 개구부를 통한 의복의 환기 양상에 미치는 영향 (Effect of Ambient Air Temperature on the Pattern of Clothing Ventilation through Openings)

  • 추미선
    • 복식문화연구
    • /
    • 제10권6호
    • /
    • pp.793-801
    • /
    • 2002
  • The effects of ambient air temperature on the clothing ventilation were investigated numerically by a finite difference method. Numerical analysis using a 2-dimensional model comprising the air space between the skin and the clothing was conducted under the assumption that the clothing ventilation occurred only through the openings not through the fabric. The larger the temperature difference between the skin and the surroundings, the more apparent the thermal boundary layer As the ambient air temperature decreased, the air flow and the rate of the return of oxygen concentration to the atmosphere level in the clothing increased. Convection was dominant under low ambient air temperature, whereas conduction was dominant under high ambient air temperature. The ventilation rate was faster in the clothing microenvironment of the body part than that of the arm part.

  • PDF

가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석 (Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System)

  • 박현우;이정수;조건환;조진수
    • 한국항공우주학회지
    • /
    • 제47권12호
    • /
    • pp.881-889
    • /
    • 2019
  • 가스터빈 이차 유로의 프리스월 시스템은 터빈의 효율을 높이고 소재의 수명을 연장하기 위해 설치되는 냉각 장치이다. 본 연구에서는 프리스월 시스템의 설계점을 기준으로 가스터빈 외기 온도와 터빈 부하 변화에 따른 탈설계점 분석을 수행하였다. 탈설계점에서 내부 유동의 특성을 분석하기 위하여 유량계수와 단열계수를 비교하였다. 터빈 부하 증가에 따라 시스템 내부 냉각 공기의 체적 유량이 증가하였고, 단열계수 또한 20% 터빈 부하와 비교하여 100% 터빈 부하에서 30.46% 상승하였다. 외기 온도가 증가할수록 질량 유량과 냉각 공기의 밀도는 감소하였지만 체적 유량은 상승하였으며, 결과적으로 프리스월 시스템 내부의 냉각 성능은 향상되었다. 프리스월 시스템 출구에서 -20℃ 외기 온도와 비교하여 55℃ 외기 온도의 단열계수는 14.82% 향상되었다.

Task-Ambient 공조시스템의 난방시 열환경 특성에 관한 실험적 연구 (The Thermal Environmental Characteristics for Task-Ambient Air-Conditioning System in Heating Condition)

  • 이정재;윤창오;정광섭;한화택;박영철
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.115-121
    • /
    • 2001
  • Recently, the requirement of healthier and more comfortable environment makes the zoning domain more details. However, it has limitation to satisfy the thermal comfort of an individual because of the effect of the heat generation from the OA machine and partitions in indoor room. In this paper, we certify the validity of task-ambient air-conditioning system that has been developed as a new concept of personal air-conditioning system, and specify design strategies for more efficient task-ambient air-conditioning system with a specification guided by indoor environmental characteristics analyzed through experiment data. In this experiment, we changed the temperature and the quantity of air-flow in task domain to understand characteristic behavior of the thermal environment and investigate the possibility of energy saving. The experiment result is that the environment of the task area depends on the condition of supply air, and though the airflow of the low temperature is supplied with the ambient area, the personal environment and the efficiency of energy saving are improved by controlling the temperature and the quantity of the air shot around the task domain.

  • PDF

저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향 (Effect of the Heat Exchange between Low and High Temperature Refrigerant on the Heat Pump Performance)

  • 이건중;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.343-350
    • /
    • 1999
  • The ambient air is commonly used as low-temperature heat source for heat pump operation. However, the coefficient of performance(COP) of the air to water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem, the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1,495.4, 1,794.5$\textrm{cm}^2$)was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The COP improvement of the heat pump could be achieved by the AVACTHE installation when below -5$^{\circ}C$ of the ambient air temperature.

  • PDF

저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향 (Effect of the Heat Exchange between Low and High Temperature Refrigerant on the Heat Pump Performance)

  • 이건중;송현갑
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1999년도 동계 학술대회 논문집
    • /
    • pp.211-218
    • /
    • 1999
  • The ambient air is commonly used as low-temperature heat sources for heat pump operation. However, the coefficient of performance (COP) of the air -water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem , the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1495.4, 1794.5$\textrm{cm}^2$) was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The high level COP of the heat pump could be achieved by the AVACTHE installation when below -5$^{\circ}C$ of the ambient air temperature.

  • PDF

태양에너지를 이용한 그린하우스 난방시스템의 열특성과 시뮬레이션 모델개발 (Thermal Energy Characteristics and Simulation Model Development for Greenhouse Heating System Using Solar Energy)

  • 노정근;송현갑
    • 한국태양에너지학회 논문집
    • /
    • 제21권2호
    • /
    • pp.27-34
    • /
    • 2001
  • The greenhouse heating system using solar energy has been realized in the protective agriculture in this study in order to analyse the thermal energy characteristics of the system the effects of ambient air temperature, solar radiation, relative humidities and water content of ambient air on the greenhouse air temperature were investigated through computer simulation experimental analysis for validation of the simulation. The results from this study are summarized as follows: 1) The expected values of inside air temperature for the system solar energy were very much close to the experimental values. 2) In the system using solar energy, the expected values of daytime surface temperature of soil by computer simulation were very much similar to the measured values, but those of nighttime were higher than the measured value by almost $2.5^{\circ}C$. 3) Heat loss of daytime was found to be larger than that of night time as much as 2.0 to 4.2 times for the system using solar energy. 4) In the system using solar energy. while the ambient air temperature varied between $-7^{\circ}C$ and $-3.8^{\circ}C$, the temperature of the inside air was maintained between $0^{\circ}C$ and $22^{\circ}C$. 5) At the minimum ambient temperature of $-7^{\circ}C$, the temperature of the inside air was $0^{\circ}C$.

  • PDF

5 RT 공랭형 $NH_3-H_2O$ 흡수식 냉동기의 발생기 입력 열량과 외기온도 변화에 따른 성능분석 (Performance Analysis of a 5 RT Air-Cooled $NH_3-H_2O$ Absorption Chiller with the Variations of Heat Input and Ambient Temperature)

  • 윤희정;김성수;강용태
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.438-443
    • /
    • 2004
  • The objective of this paper is to study the effects of the input gas flow rate and the ambient temperature variation on the absorption cycle performance. An air-cooled NH$_3$-$H_2O$ absorption chiller is tested in the present study. The nominal cooling capacity of the single effect maching is 17.6 ㎾ (5.0 USRT). The cooling capacity, coefficient of performance, burner efficiency, and each state point are measured with the variations of the heat input and the ambient temperature. It is found that the COP and cooling capacity increase with increasing the generator exit temperature up to a certain temperature and then decrease. It is also found that the COP and the cooling capacity decrease with increasing the ambient temperature. The maximum COP of 0.51 is obtained from the present experiment.

겨울철 냉기를 이용한 벼의 저온저장(I) - 벼 냉각 후 저장특성 - (Low Temperature Storage of Rough Rice Using Cold-Air in Winter(I) - Storage Characteristics after Rough Rice Cooling -)

  • 이재석;한충수;함택모;연광석
    • Journal of Biosystems Engineering
    • /
    • 제30권3호
    • /
    • pp.155-160
    • /
    • 2005
  • The objective of this research was to establish a domestically available cooling storage technique by cold-air in winter, using winter cool air ventilation fur determining rough rice cooling method in the storage and dry bin. The rough rice storage characteristics of two test conditions, winter cool-air ventilation storage and ambient temperature storage, were evaluated from January to July 2001, using a storage and dry bin of 300-ton capacity. Results of this research are as follows: Grain temperature was from $-5.1\~-8.5^{\circ}C$ after winter cool-air ventilation, and grain initial temperature for ambient temperature bin storage was $0.3\~1.9^{\circ}C$. Moisture content of rough rice decreased from $0.28\;to\;0.93\%$ and from $1.53\;to\;1.92\%$ to compare with original moisture contents for winter cool-air ventilation, and for ambient temperature bin storage, respectively. Broken ratio of brown rice from winter cool-air ventilation bin increased from $0.16\;to\; 0.92\%$, and brown rice broken ratio was from $2.24\;to\;2.86\%$ for ambient temperature bin storage to compare with initial broken ratio. Hardness of stored rice increased along storage period increase in alt storage methods, and cooling bin storage increased rice hardness of 0.271kgf: this increasing was lower then the other methods from 0.059 to 2.239kgf. Germination rates were decreased approximately 9.03, 3.14 and $3.20\%$ for upper, middle, and bottom of ventilating winter air bin, respectively, and germination rates of 2.70, 3.47 and $4.14\%$ were approximately decreased for upper, middle, and bottom parts of ambient temperature bin storage, respectively.

대기온도 변화에 따른 150 MW 화력발전소용 공랭식 복수기 송풍기수 선정 (Selection of Number of Fans in an Air-Cooled Condenser of a 150 MW Thermal Power Plant according to Ambient Air Temperature)

  • 황용훈;허기무;윤성훈;문윤재;이재헌;문승재
    • 플랜트 저널
    • /
    • 제10권4호
    • /
    • pp.24-28
    • /
    • 2014
  • 본 연구에서는 150 MW 화력발전소를 기준하여 발전소 건설지역의 최저 대기온도 $-17.1^{\circ}C$부터 최대 대기온도 $36.7^{\circ}C$까지를 $3^{\circ}C$의 일정한 간격으로 구분하여 복수기 압력이 증기터빈의 배압조건을 만족하는 대기온도별 송풍기 수량을 검토하였다. 공랭식 복수기는 대기온도 및 송풍기 운전수량 변화에 따른 냉각공기 순환량에 영향을 받아 운전조건이 변경이 되므로, 대기온도가 복수기 설계기준온도 이상의 경우에는 공랭식 복수기 송풍기의 운전수량을 최대로 해야 하고, 대기온도가 복수기 설계기준온도 미만의 경우에는 증기터빈 배압 운전조건을 만족하는 범위 내에서 송풍기 운전수량을 변화시켜 공랭식 복수기에 가해지는 공기 순환량을 감소시키는 것이 안정적인 발전소 운영을 하는 것임을 확인하였다.

  • PDF