• Title/Summary/Keyword: ambient air pressure

Search Result 164, Processing Time 0.027 seconds

Parametric Studies on the Sensitivity of Single Isolated Aluminum Particle Combustion Modeling (알루미늄 입자 연소 지배인자의 민감도 해석)

  • Lee, Sang-Hyup;Ko, Tae-Ho;Yang, Hee-Sung;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.321-327
    • /
    • 2010
  • A simplified analytical modeling for micro-sized single metal particle combustion in air was conducted in the present study. The metal particle combustion consists of two distinct reaction regimes, ignition and quasi-steady burning, and the thermo-fluidic phenomena in each stage are formulated by virtue of the conservation and transport equations. Reliability of the model is shown by rigorous validation of the method with emphasis laid on the characterizing the commanding parameters. Effects of Initial particle size, initial oxide film thickness, convection, ambient pressure and temperature are examined and addressed with validation.

  • PDF

A Study on the Laminar Burning Velocity of Synthetic Gas of Coal Gasification(H2/CO)-Air Premixed Flames (석탄가스화 합성가스(H2/CO)-공기 예혼합화염의 층류 연소속도에 관한 연구)

  • Jeong, Byeonggyu;Lee, Keeman
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.5
    • /
    • pp.493-502
    • /
    • 2012
  • Syngas laminar burning velocity measurements were carried out at atmospheric pressure and ambient temperature using the Bunsen flame configuration with nozzle burner as a fundamental study on flame stability of syngas fuel. Representative syngas mixture compositions ($H_2$:CO) such as 25:75%, 50:50% and 75:25% and equivalence ratios from 0.5 to 1.4 have been conducted. Average laminar burning velocities have been determined by the stabilized nozzle burner flames using the angle method, radical surface area method and compared with the data obtained from the other literatures. And the results of each experimental methodologies in the various composition ratios and equivalence ratios were coincided with the result of numerical simulation. Especially, it was confirmed that there was necessary to choice a more accurate measurement methodology even the same static flame method for the various composition ratios of syngas fuel including hydrogen. Also, it was reconfirmed that the laminar burning velocities gradually increased with the increasing of hydrogen content in a fuel mixture.

Parametric Studies on the Sensitivity of Single Isolated Aluminum Particle Combustion Modeling (단일 마그네슘 입자 연소 지배인자의 민감도 해석)

  • Lee, Sang-Hyup;Ko, Tae-Ho;Yoon, Woong-Sup;Yang, Hee-Sung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.341-350
    • /
    • 2011
  • A simplified analytical study for micro-sized single metal particle combustion in air was conducted in the present study. The metal particle combustion consists of two distinct reaction regimes, ignition and quasi-steady burning, and the thermo-fluidic phenomena in each stage are formulated by virtue of the conservation and transport equations. When particle temperature reaches to 1200 K, ended an ignition stage and was converted at quasi-steady combustion stage. Effects of Initial particle size, convection, ambient pressure and temperature are examined and addressed with validation.

  • PDF

Comparison on Safety Features among HTGR's Reactor Cavity Cooling Systems (RCCSs)

  • Kuniyoshi Takamatsu;Shumpei Funatani
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.832-845
    • /
    • 2024
  • Reactor cavity cooling systems (RCCSs) comprising passive safety features use the atmosphere as a coolant, which cannot be lost. However, their drawback is that they are easily affected by atmospheric disturbances. To realize the commercial application of the two types of passive RCCSs, namely RCCSs based on atmospheric radiation and atmospheric natural circulation, their safety must be evaluated, that is, they must be able to remove heat from the reactor pressure vessel (RPV) surface at all times and under any condition other than under normal operating conditions. These include both expected and unexpected natural phenomena and accidents. Moreover, they must be able to eliminate the heat leakage emitted from the RPV surface during normal operation. However, utilizing all of the heat emitted from the RPV surface increases the degree of waste heat utilization. This study aims to understand the characteristics and degree of passive safety features for heat removal by comparing RCCSs based on atmospheric radiation and atmospheric natural circulation under the same conditions. It was concluded that the proposed RCCS based on atmospheric radiation has an advantage in that the temperature of the RPV could be stably maintained against disturbances in the ambient air.

Atmospheric Distribution of PCDD/F Concentrations in Gyeonggi-do, South Korea (경기도 내 대기 중 다이옥신 분포 특성에 관한 연구)

  • Heo, Jong-Won;Min, Yoon-Ki;Kim, Dong-Gi;Choi, Il-Woo;Kim, Jong-Soo;Song, Il-Seok;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.6
    • /
    • pp.548-561
    • /
    • 2015
  • Atmospheric concentrations of polychlorinated dibezo-p-dioxins and furans (PCDD/Fs) were investigated at urban-residential (Group I: Suwon, Guri and Goyang), industrial (Group II: Ansan, Siheung and Bucheon), urban-rural mixed (Group III: Yangju, Pocheon and Dongducheon) and rural regions (Group IV: Yangpyeong) in Gyeonggi-do from February 2012 to November 2012 quarterly. The concentrations of PCDD/Fs ranged from 0.018 to $0.109pgTEQm^{-3}$ in Group I (mean value: $0.061pgTEQm^{-3}$), 0.059 to $0.367pgTEQm^{-3}$ in Group II (mean value: $0.179pgTEQm^{-3}$), 0.072 to $0.836pgTEQm^{-3}$ in Group III (mean value: $0.334pgTEQm^{-3}$) and 0.014 to $0.066pgTEQm^{-3}$ in Group IV (mean value: $0.034pgTEQm^{-3}$), respectively. In spite of the less PCDD/F emission sources than Group II (industrial regions), the level of PCDD/Fs in urban-rural mixed area showed the highest values with high fluctuation. It's likely that the Group III was affected by fugitive emissions such like biomass burning and unregulated open burning. The mean contribution of particle phase to total PCDD/F concentration was above 83% because most of PCDD/F congeners were partitioned into particle phase. We evaluated their gas-to-particles equilibriums with the regression between the particle-gas partition coefficient, $K_P(m^3{\mu}g^{-1})$ and corresponding subcooled liquid vapor pressure ($P_L$). The logarithm-$K_P$ of PCDD/Fs was poorly correlated with $P_L$ at low ambient temperature (below $10^{\circ}C$) and the slope (m) values for log-log plots of the $K_P$ vs. $P_L$ was steeper in the Group 2 and Group 3 than residential area. It implies that the slope values were likely influenced by both the direct emission source of PCDD/Fs and ambient temperature.

Comparisons of Collection 5 and 6 Aqua MODIS07_L2 air and Dew Temperature Products with Ground-Based Observation Dataset (Collection 5와 Collection 6 Aqua MODIS07_L2 기온과 이슬점온도 산출물간의 비교 및 지상 관측 자료와의 비교)

  • Jang, Keunchang;Kang, Sinkyu;Hong, Suk Young
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.571-586
    • /
    • 2014
  • Moderate Resolution Imaging Spectroradiometer (MODIS) provides air temperature (Tair) and dew point temperature (Tdew) profiles at a spatial resolution of 5 km. New Collection 6 (C006) MODIS07_L2 atmospheric profile product has been produced since 2012. The Collection 6 algorithm has several modifications from the previous Collection 5 (C005) algorithm. This study evaluated reliabilities of two alternative datasets of surface-level Tair and Tdew derived from C005 and C006 Aqua MODIS07_L2 (MYD07_L2) products using ground measured temperatures from 77 National Weather Stations (NWS). Saturated and actual vapor pressures were calculated using MYD07_L2 Tair and Tdew. The C006 Tair showed lower mean error (ME, -0.76 K) and root mean square error (RMSE, 3.34 K) than the C005 Tair (ME = -1.89 K, RMSE = 4.06 K). In contrasts, ME and RMSE of C006 Tdew were higher than those (ME = -0.39 K, RMSE = 5.65 K) of C005 product. Application of ambient lapse rate for Tair showed appreciable improvements of estimation accuracy for both of C005 and C006, though this modification slightly increased errors in C006 Tdew. The C006 products provided better estimation of vapor pressure datasets than the C005-derived vapor pressure. Our results indicate that, except for Tdew, C006 MYD07_L2 product showed better reliability for the region of South Korea than the C005 products.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Performance Evaluation of a Natural Smoke Ventilator in Jeju (배연창의 개방층 설정방식에 따른 배연성능 평가 연구(제주지역 중심으로))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.6-11
    • /
    • 2016
  • This study analyzed the performance of smoke exhaustion installed to secure the life safety from the smoke each opening modes, as performing the simulation on the Jeju regions generating to strong windy using CONTAM. We assessed the effectiveness of the system under conditions of high external winds as well as an ambient wind conditions. It also assessed the relative effectiveness of opening all vents versus opening only those vents which served rooms in which the fire was located. This study revealed external winds exerted a substantial impact on the performance of the smoke ventilation system. It was found that opening the ventilation system in the room containing the fire resulted in a greater performance than opening vents in both fire in all rooms. The reduced performance of the smoke ventilation system upon the opening of all vents is thought to be due to the intrusion of outside air, and the establishment of unfavorable air circulation, caused by the negative pressure generated in the building.

Effectiveness of Photocatalytic Techniques for Disinfection of Indoor Bioaerosols (실내 미생물 입자 살균을 위한 광촉매 기술의 효율)

  • Shin, Seoung-Ho;Kim, Mo-Geun;Jo, Wan-Kuen
    • Journal of Environmental Science International
    • /
    • v.16 no.7
    • /
    • pp.785-791
    • /
    • 2007
  • The current study evaluated the technical feasibility of the application of titanium dioxide ($TiO_{2}$) photo-catalytic air cleaners for the disinfection of bioaerosols present in indoor air. The evaluation included both laboratory and field tests and the tests of hydraulic diameter (HD) and lamp type (LT). Disinfection efficiency of photocatalytic oxidation (PCO) technique was estimated by survival ratio of bacteria or fungi calculated from the number of viable cells which form colonies on the nutrient agar plates. It was suggested that the reactor coating with $TiO_{2}$ did not enhance the adsorption of bioaerosols, and that the UV irradiation has certain extent of disinfection efficiency. The disinfection efficiency increased as HD decreased, most likely due to the decrease in the light intensity since the distance of the catalyst from the light source increased when increasing the HD. It was further suggested that the mass transfer effects were not as important as the light intensity effects on the PCO disinfection efficiency of bioaerosols. Germicidal lamp was superior to the black lamp for the disinfection of airborne bacteria and fungi, which is supported by the finding that the disinfection efficiencies were higher when the germicidal lamp was used compared to the black lamp in the laboratory test. These findings, combined with operational attributes such as a low pressure drop across the reactor and ambient temperature operation, can make the PCO reactor a possible tool in the effort to improve indoor bioaerosol levels.

Study on the performance characteristics of a new CO2 auto-cascade heat pump system (새로운 CO2 오토 캐스케이드 열펌프 시스템의 성능특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.191-196
    • /
    • 2017
  • Owing to the harmful environmental effects of HCFC and CFC refrigerants discovered in the late 20th century, the need for environmentally friendly refrigerants such as $CO_2$ in cooling systems has increased. Air-source $CO_2$ heat pumps that utilize ambient heat in cold winter are less efficient because of a higher evaporation temperature, and it is difficult to manufacture the components of the heat pump owing to a super critical pressure of over 130 bar. This research aims to overcome these disadvantages and improve energy efficiency by introducing a new lower-pressure $CO_2$ auto-cascade heat pump system. $CO_2$-R32 zeotropic refrigerants were considered for two-stage expansion and effective cooling heat exchanging system configurations of the new auto-cascade heat pump. The results indicated that the efficiency of the two-stage expansion system was higher than that of the original one-stage expansion system. Furthermore, the two-stage expansion system showed significant performance improvements when the two-stage expansion stage from highest pressure of 70bar, intermediate expansion pressure of 25bar, and final low pressure of 10bar is applied. The COP of the new two-stage auto-cascade system (2.332) was 43.15% higher than that of the present simple auto-cascade system (1.629). Refrigerants having an evaporation temperature of $-10^{\circ}C$ or lower can be obtained that can be easily evaporated in an evaporator even at a low temperature.