• 제목/요약/키워드: ambient air

검색결과 1,458건 처리시간 0.032초

물-에너지 넥서스기반 국내 댐 가능최대 수열에너지 산정 (Estimation of the Probable Maximum Water Thermal Energy in Korean Dams based on the Water-Energy Nexus Concept)

  • 정영훈
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.45-53
    • /
    • 2018
  • Demand for essential resources including water, energy and food is rapidly increasing due to climate change, population growth and urbanization. To solve this problem, the concept of water-energy-food nexus has been introduced, and many countries have been trying to acquire the Nexus technology that can maximize the efficiency by analyzing the interconnection between resources. In this regard, this study attempted to estimate the probable maximum water thermal energy in the dam based on the water-energy nexus concept. The estimation of the probable maximum water thermal energy was implemented to monthly water storage of the largest dams in the four major river systems. As a result of analyzing the estimated monthly water thermal energy from 2000 to 2016, Soyang River dam has the largest probable maximum water thermal energy, and Sumjin River dam has the smallest. However, the probable maximum water thermal energy was small in common between March and April, between September and October due to the small temperature difference between the ambient air and the dam water. Also, according to the characteristics of the dam, Daecheong dam and Soyang River dam were beneficial for supplying water thermal energy for heating, and Sumjin River dam and Andong dam were advantageous for supplying water thermal energy for cooling. Our findings can be useful to realize the water-energy-food nexus by increasing the utilization and value of water resources as well as expanding the roles and functions of dams as a starting point to use dam water thermal energy.

무창산란계사의 환경분석에 관한 연구 (Environmental Analysis in the Windowless Laying Hen Houses)

  • 이성현
    • Journal of Biosystems Engineering
    • /
    • 제28권3호
    • /
    • pp.225-230
    • /
    • 2003
  • This study was carried out to analyze the environmental variation of layer house at Iowa State in the USA. The analyzed seasons for this study were summer and winter. Analyzing factors are inside temperature and relative humidity, carbon dioxide concentration, ammonia concentration and emission. All factors were collected every 30 second from each house with portable monitoring units. In this study, two types of laying hen houses were monitored at the same season. One was a manure belt house, the other was a high-rise house. In order to estimate the ventilation rates of the laying hen houses, carbon dioxide concentration balance was used in this study. Ammonia concentrations and emission rates of the manure belt house are much lower than those of the high rise house. Daily mean ammonia concentrations in the manure belt house and high-rise house ranged from 3 to 7 ppm and 5 to 34 ppm, respectively. The daily ammonia emission rates averaged 0.68g/h$\cdot$500kg and 0.73g/h$\cdot$500kg for the manure belt house and 0.93g/h$\cdot$500kg and 2.89g/h$\cdot$500kg for the high-rise house in summertime and wintertime, respectively. Summertime is associated with much higher ammonia emission rates than wintertime because of much higher ventilation rates and ambient air temperature, even though the concentrations may be lower.

어린이 건강관련 유해물질 연구방향 (Chemical Risk Factors for Children's Health and Research Strategy)

  • 이효민;정기화
    • 한국식품위생안전성학회지
    • /
    • 제23권3호
    • /
    • pp.276-283
    • /
    • 2008
  • 국내 외 선행연구결과에 의한 어린이 출생 전 후 건강에 영향을 미칠 수 있는 주요 유해물질은 inorganic arsenic, BPA, 2,4-D, dichlorvos, methylmercury, PCBs, pesticide, phthalate, PFOA/PFOS, vinyl chloride 등으로서 국내에서도 이들을 포함한 확인 연구가 수행되어져야 할 것이다. 또한 어린이들의 행동발달과 연관된 생활환경에서의 다양한 인체노출이 확인됨에 따라 탁아소, 유치원과 같은 경우 어린이 활동공간을 대상으로 환경모니터링 및 위해관리활동도 병행되어야 할 것이다. 또한 어린이 건강에 영향을 미치는 유해물질을 중심으로 독성평가, 인체영향연구, 환경 및 인체모니터링과 위해평가를 수행하므로 유해물질의 원인-상관관계를 확인하고 사실자료에 근거한 관리정책을 반영하는 것이 바람직하다.

대도시 교통밀집지역 도로변 대기 중 휘발성유기화합물의 농도분포 특성 (Characteristics of Atmospheric Concentrations of Volatile Organic Compounds at a Heavy-Traffic Site in a Large Urban Area)

  • 백성옥;김미현;박상곤
    • 한국대기환경학회지
    • /
    • 제18권2호
    • /
    • pp.113-126
    • /
    • 2002
  • This study was carried out to evaluate the temporal (daily, weekly, and seasonal) variations of volatile organic compounds (VOCs) concentrations at a road-side site in a heavy-traffic central area of Metropolitan Taegu. Ambient air sampling was undertaken continuously for 14 consecutive days in each of four seasons from the spring of 1999 to the winter of 2000. The VOC samples were collected using adsorbent tubes, and were determined by thermal desorption coupled with GC/MS analysis. A total of 10 aromatic VOCs of environmental concern were determined, including benzene, toluene, ethylbenzene, m+p-xylenes, styrene, o-xylene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, and naphthalene. Among 10 target VOCs, the most abundant compounds appeared to be toluene (1.5 ∼ 102 ppb) and xylenes (0.1 ∼ 114 ppb), while benzene levels were in the range of 0.3 ∼6 ppb. It was found that the general trends of VOC levels were significantly dependent on traffic conditions at the sampling site since VOC concentrations were at their maximum during rush hours (AM 7∼9 and PM 7 ∼9). However, some VOCs such as toluene, xylenes, and ethylbenzene were likely to be affected by a number of unknown sources other than vehicle exhaust, being attributed to the use of paints, and/or the evaporation of solvents used nearby the sampling site. In some instances, extremely high concentrations were found for these compounds, which can not be explained solely by the impact of vehicle exhaust. The results of this study may be useful for estimating the relative importance of different emission sources in large urban areas. Finally, it was suggested that the median value might be more desirable than the arithmetic mean as a representative value for the VOC data group, since the cumulative probability distribution (n=658) does not follow the normal distribution pattern.

휘발유 자동차의 메탄(CH4) 배출특성에 관한 연구 (A Study on Characteristics of Methane Emissions from Gasoline Passenger Cars)

  • 전민선;류정호;유영숙;김종춘;임철수;김대욱;정성운;조석연
    • 한국대기환경학회지
    • /
    • 제21권6호
    • /
    • pp.649-655
    • /
    • 2005
  • Automotive exhaust is suspected to be one of the main reasons of the rapid increase in greenhouse effect gases in ambient air. Although methane emissions are generally orders of magnitude lower than emissions of $CO_{2}$, the global warming potential (GWP) of methane is greater than that of $CO_{2}$. The environmental impact of methane emissions from vehicles is negligible and is likely to remain so for the foreseeable future. In this study, in order to investigate greenhouse gas emission characteristics from gasoline passenger cars, 20 vehicles were tested on the chassis dynamometer and methane emissions were measured. The emission characteristics by model year, mileage, vehicle speed were discussed. Test mode is CVS-15 mode that have been used to regulate for light-duty vehicle in Korea. It was found that $CH_{4}$ emissions showed higher for cold start, old model year and long mileage than hot start, new model year and short mileage, respectively. These results were compared with IPCC emission factors and the overall our results were anticipated to contribute for domestic greenhouse gas emissions calculation.

유성 볼밀을 통해 제조된 TiO2-xNx 광촉매의 가시광 활성도와 NH3양 및 분쇄시간과의 상관 관계 (The Relation Between a Visible-light Photocatalytic Activity of TiO2-xNx and NH3 Amount/the Period of Grinding Time)

  • 강인철;고준빈;한재길;김광희;최성창
    • 한국분말재료학회지
    • /
    • 제16권3호
    • /
    • pp.196-202
    • /
    • 2009
  • A visible-light photoactive $TiO_{2-x}N_x$ photocatalyst was synthesized successfully by means of cogrinding of anatase-$TiO_2(a-TiO_2)$ in $NH_3$ ambient, followed by heat-treatment at $200^{\circ}C$ in air environment. In general, it is well known that the grinding-operation induces phase transformation of a-$TiO_2$ to rutile $TiO_2$. This study investigates the influence of the amount of $NH_3$ gas on the phase transformation rate of a-$TiO_2$ and enhancement of visible-light photocatalytic activity, and also examines the relation between the photocatalytic activity and the period of grinding time. The phase transformation rate of a-$TiO_2$ to rutile is retarded with the amount of NH3 injected. And the visible-light photocatalytic activity of samples, was more closely related to the period of grinding time than $NH_3$ amount injected, which means that the doping amount of nitrogen into $TiO_2$ more effective to mechanical energy than $NH_3$ amount injected. XRD, XPS, FT-IR, UV-vis, Specific surface area (SSA), NOx decomposition techniques are employed to verify above results more clearly.

고 에너지 레이저를 통한 알루미늄-산소 연소현상에 대한 분광분석 (The spectroscopic study of chemical reaction of laser-ablated aluminum-oxygen by high power laser)

  • 김창환;여재익
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.608-611
    • /
    • 2011
  • 이차 추진제로 많이 쓰이는 알루미늄을 고출력 레이저를 이용하여 공기 중의 산소와 반응시켜 발생되는 rich 및 stoichiometric 상태의 알루미늄-산소 연소 현상에 대해 레이저 분광분석법을 이용하여 연구하였다. 7ns의 펄스 주기와 1064nm의 주파수를 가진 Q-switched Nd:YAG 레이저로 40 - 2500mJ의 에너지가 공급되었으며, 플라즈마 빛은 echelle 회절 분광기와 ICCD 카메라로 감지하였다. 레이저 분광분석을 통하여 연료인 알루미늄과 산화제인 산소의 원자 신호를 얻었을 뿐만 아니라, 현상이 일어나는 환경인 플라즈마 온도와 전자밀도가 계산되었다. 특정 전자 밀도비 비교를 통하여, 고출력 레이저를 통해 일어나는 알루미늄과 산소의 연소 및 폭발 현상 변화에 대한 분석이 가능하다는 것에 본 논문의 중요성이 있다.

  • PDF

Effects of rehydration fluid temperature and composition on body weight retention upon voluntary drinking following exercise-induced dehydration

  • Park, Sung-Geon;Bae, Yoon-Jung;Lee, Yong-Soo;Kim, Byeong-Jo
    • Nutrition Research and Practice
    • /
    • 제6권2호
    • /
    • pp.126-131
    • /
    • 2012
  • The purpose of this study was to determine the effects of beverage temperature and composition on weight retention and fluid balance upon voluntary drinking following exercise induced-dehydration. Eight men who were not acclimated to heat participated in four randomly ordered testing sessions. In each session, the subjects ran on a treadmill in a chamber maintained at $37^{\circ}C$ without being supplied fluids until 2% body weight reduction was reached. After termination of exercise, they recovered for 90 min under ambient air conditions and received one of the following four test beverages: $10^{\circ}C$ water (10W), $10^{\circ}C$ sports drink (10S), $26^{\circ}C$ water (26W), and $26^{\circ}C$ sports drink (26S). They consumed the beverages ad libitum. The volume of beverage consumed and body weight were measured at 30, 60, and 90 min post-recovery. Blood samples were taken before and immediately after exercise as well as at the end of recovery in order to measure plasma parameters and electrolyte concentrations. We found that mean body weight decreased by 1.8-2.0% following exercise. No differences in mean arterial pressure, plasma volume, plasma osmolality, and blood electrolytes were observed among the conditions. Total beverage volumes consumed were $1,164{\pm}388$, $1,505{\pm}614$, $948{\pm}297$, and $1,239{\pm}401$ ml for 10W, 10S, 26W, and 26S respectively ($P$ > 0.05). Weight retention at the end of recovery from dehydration was highest in 10S ($1.3{\pm}0.7kg$) compared to 10W ($0.4{\pm}0.5kg$), 26W ($0.4{\pm}0.4kg$), and ($0.6{\pm}0.4kg$) ($P$ < 0.005). Based on these results, carbohydrate/electrolyte-containing beverages at cool temperature were the most favorable for consumption and weight retention compared to plain water and moderate temperature beverages.

수원지역 분진의 입경별 이온성분 분포특성에 관한 연구 (Characteristics of Ionic Components in Size-resolved Particulate Matters in Suwon Area)

  • 오미석;이태정;김동술
    • 한국대기환경학회지
    • /
    • 제25권1호
    • /
    • pp.46-56
    • /
    • 2009
  • The main purpose of this study was to investigate air quality trends of ambient aerosol with obtaining size-fractionated information. The suspended particulate matters were continuously collected on membrane filters and glass fiber filters by an 8-stage cascade impactor for 2 years (Sep. 2005 $\sim$ Sep. 2007) in Kyung Hee University-Global Campus. 8 ionic species ($Na^+$, ${NH_4}^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, ${NO_3}^-$, and ${SO_4}^{2-}$) were analyzed by an IC after performing proper pretreatments of each sample filter. The average concentration levels of each ion were $9.24{\mu}g/m^3$ of ${SO_4}^{2-}$, $7.35{\mu}g/m^3$ of ${NO_3}^-$, $2.81{\mu}g/m^3$ of ${NH_4}^+$, $2.11{\mu}g/m^3$ of $Ca^{2+}$, $1.65{\mu}g/m^3$ of $Cl^-$, $1.87{\mu}g/m^3$ of $Na^+$, $0.80{\mu}g/m^3$ of $Mg^{2+}$, and $0.54{\mu}g/m^3$ of $K^+$, respectively. The distribution pattern of $Na^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, and ${NO_3}^-$ was bi-modal and two peaks appeared in the range of $0.4{\sim}0.7{\mu}m$ and $3.3{\sim}4.7{\mu}m$, respectively. On the other hand, ${SO_4}^{2-}$, ${NH_4}^+$, and $K^+$ showed patterns of uni-modal distribution, mostly abounded in the fine mode group.

District Energy Use Patterns and Potential Savings in the Built Environment: Case Study of Two Districts in Seoul, South Korea

  • Lee, Im Hack;Ahn, Yong Han;Park, Jinsoo;Kim, Shin Do
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권1호
    • /
    • pp.48-58
    • /
    • 2014
  • Energy efficiency is vital to improve energy security, environmental and social sustainability, and economic performance. Improved energy efficiency also mitigates climate change by lowering greenhouse gas (GHG) emissions. Buildings are the single largest industrial consumer of energy and are therefore key to understanding and analyzing energy consumption patterns and the opportunities for saving energy at the district level in urban environments. This study focused on two representative boroughs in the major metropolitan area of Seoul, South Korea as a case study: Gandong-gu, a typical residential district, and Jung-gu, a typical commercial district. The sources of the energy supplied to the boroughs were determined and consumption patterns in different industry sectors in Seoul used to identify current patterns of energy consumption. The study analyzed the energy consumption patterns for five different building categories and four different sectors in the building using a bottom-up energy modeling approach. Electricity and gas consumption patterns were recorded for different building categories and monthly ambient temperatures in the two boroughs. Finally, a logarithmic equation was developed to describe the correlation between commercial activity and cooling energy intensity in Jung-gu, the commercial district. Based on these results, recommendations are made regarding the current energy consumption patterns at the district level and government energy policies are suggested to reduce energy consumption and, hence, greenhouse gas emissions, in both commercial and residential buildings.