• Title/Summary/Keyword: alveolar molding

Search Result 15, Processing Time 0.019 seconds

Bilateral cleft lip (양측성 구순열)

  • Kim, Jong-Ryoul
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.10 no.1
    • /
    • pp.39-56
    • /
    • 2007
  • The bilateral cleft lip, a more severe form of clefting than unilateral cleft lip, involves separation of the lip along philtral lines, isolating the central segment (prolabium). Bilateral cleft lip may be either symmetrical or asymmetrical, in which case the cleft lip is split more on one side than on the other. The cleft affects the obvious facial form as an anatomic deformity and has functional consequences, affecting the child's ability to eat, speak, hear, and breathe. Although there would seem to be quite a variance in reported figures, ratios of cleft lip with or without cleft palate have gone as high as 1:500 and as low as 1:1000. It is known that less than 10% of cleft lips are bilateral. Although bilateral cleft lip is less common than unilateral cleft lip, the deformity is more severe, and the reconstructive technique is more complex. Surgery is the only treatment necessary for patients with bilateral cleft lip. Accompanying the evolution of surgical repair is the increasingly important role of orthodontic support with early presurgical alveolar and nasal molding. Repositioning the maxillary and alveolar segments into a more anatomic position allows the surgeon to repair the lip and associated nasal deformity under more optimal conditions. The purpose of this article is to review the related anatomy, presurgical management, and surgical management of bilateral cleft lip.

  • PDF

Effect of Presurgical Nasoalveolar Molding in Unilateral Cleft Lip and Palate Infants (편측성 구순구개열 신생아에 대한 술전비치조정형장치의 효과)

  • Kim, Jin-Sun;Kim, Young-Jin;Nam, Soon-Hyeun;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.3
    • /
    • pp.209-215
    • /
    • 2013
  • Cleft lip and palate, the most common craniofacial anomalies, are severe congenital defects that have an incidence of 0.28 to 3.74 per 1000 live births. Although there has been great improvement in the field of cleft surgery, surgical approach cannot be the single solution to resolve the various problems encountered in patients with cleft lip and palate. The concept of presurgical infant orthopedics (PSIO) for gradual closure of the cleft gap and simplified surgical performance was first introduced by McNeil in 1950. Recently, there are many attempts not only to approximate the alveolar segments but also to reshape the nasal cartilage. Three infants with unilateral cleft lip and palate were referred from the department of Plastic Surgery for presurgical nasoalveolar molding (PNAM). Maxillary appliances using resin with orthodontic wire were fabricated. Then these appliance was applied until patients underwent lip surgery. In all cases, the patients could wear the appliance all day since they were able to eat even with the appliance on, This resulted in significant improvements in the nasal symmetry were found. Our appliance, namely K-NAM, extends the wearing time within the limited period and as a result it is expected to maximize the treatment effects. Used properly, this appliance would play a major role in enhancing nasal symmetry with satisfactory results.

3-Dimensional Analysis of Alveolar Molding Effect of Presurgical Nasoalveolar Molding Appliance and Lip Pressure After Cheiloplasty in Complete Unilateral Cleft Lip and Palate Patients (편측성 구순구개열 환자의 술전 비치조 정형장치와 구순 봉합수술의 치조골 정형효과의 3차원 분석)

  • Kim Na-Young;Kwon Sun-Man;Baek Seung-Hak
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.7 no.2
    • /
    • pp.93-106
    • /
    • 2004
  • 본 연구의 목적은 편측성 구순구개열 (UCLP) 환자에서 술전 비치조 정형장치 (presurgical nasoalveolar molding appliance, PNAM) 와 구순 봉합수술의 치조골 정형효과를 3차원 (3-D) 분석을 통하여 평가하는 것이다. 연구대상은 16명의 UCLP 환자 (평균 파열부거리: 10.46mm) 이며 PNAM 장치에 의한 치료와 rotation-advancement법에 의한 구순 봉합수술을 받았다 처음 내원시 (평균연령: $37.0{\pm}27.89$ 일), PNAM 치료를 받고 난 후이며 구순봉합수술 1달 전 (평균연령: $119.25{\pm}40.18$ 일), 구순봉합수술 2달 후 (평균연령: $190.81{\pm}42.78$ 일)에 상악의 인상을 채득하였다. 그 후 laser scanning machine (Orapix, Dimennex, Seoul, Korea) 과 3-D view software (3Dxer, Dimennex) 를 사용하여 3-D모형을 제작하였다. 선, 각도, 정중선변이, 거리, 면적 항목을 3-D 모형상에서 계측하고, 각 시기별의 차이를 비교하기 위하여 Wilcoxon signed rank test를 사용하여 분석하였다. PNAM치료 동안과 구순 봉합수술 후에도 치조골 후방부는 안정된 구조물이었다. PNAM치료에 의한 파열부 거리의 감소는 대분절 (greater segment) 의 내측 굴곡 (bending) 에 의하여 발생하였다. 대분절 (greater segment)의 전방 성장은 PNAM치료에 의하여 억제되었으나, 구순 봉합수술 후에 회복되었다. 구순 봉합수술 후에 대분절과 소분절 사이의 전방부 각도의 증가는 구순 반흔 (lip scar) 의 압력에 의한 치조골 정형 효과 때문으로 생각된다. 정중선변이는 PNAM치료에 의하여 개선되었다. PNAM치료 동안과 구순 봉합수술 후에 구개부 (palatal segment) 의 면적은 계속 증가하였다. 치조골 면적과 거리 항목의 증가는 후방부에서 크게 나타났다. 이러한 결과는 PNAM치료에 의한 치조골 정형효과는 주로 전방부에서 발생하며, 치조골의 성장은 구순 봉합수술 후에 후방부에서 주로 발생한다는 것을 의미한다.

  • PDF

DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING (의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구)

  • Choi Hoon-Dal;Kwon Kung-Rock;Kim Hyeong-Seob;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.