• Title/Summary/Keyword: alternator voltage

Search Result 18, Processing Time 0.022 seconds

A Study about Impact of Battery SOC on Fuel Economy of Conventional Diesel Vehicle (배터리 충전상태가 경유자동차 에너지소비효율에 미치는 영향 연구)

  • Kim, Sungwoo;Kim, Kiho;Ha, Jonghan;Kwon, Seokjoo;Seo, Youngho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.4
    • /
    • pp.480-486
    • /
    • 2016
  • Manufacturers have been applying several technologies that can improve the fuel economy of their cars. The regulated voltage control(RVC) system, is one of those technologies being used in passenger cars. In RVC, the voltage of an alternator is controlled depending on the electrical load demand or battery SOC, although each manufacturer differs from another in terms of detail. RVC can reduce the load of an alternator by consuming the stored energy of a battery and simultaneously generate energy. In this paper, a diesel passenger car equipped with an RVC system was tested under FTP-75 and HWFET modes to evaluate fuel economy as their initial battery SOC(100, 90, 80 and 60 %). The test results showed that the initial SOC affects fuel economy only under the FTP-75 mode. FTP-75 fuel economy of the 60% SOC was 13.2 % lower than the 100 % SOC. Also, the simultaneous consumption of the two energy sources did not appear in 60 % SOC.

A Study on the Controlling Method of Hunting Inducing Point during Parallel Running of alternator Equipped with converter (컨버터가 내장된 교류발전기 병렬운전중의 헌팅 억제에 관한 연구)

  • 노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.346-351
    • /
    • 1999
  • This paper is a research for removing the hunting which came about during the parallel running of the alternators which four-pole six-phase have the converter with twelve diodes to rectify all the waves. Druing the parallel running the hunting came about under the period of 0.2-0.3{sec} not when it's load was the resistance but the capacity at the rpm band 1575[rpm] 1690[rpm] This hunting in our judgement was not come about from the general hunting causes which have been already known to but the special example. And so we checked that the hunting came about or not as per the changes of the rpm exciting current load current and converter and converter output voltage and the following facts were revealed. -The hunting occured during the constant voltage charging where r. p. m band is from 1575[rpm] to 1690[rpm] - The hunting did not came about during the constant power charging in which there was the large difference between the converter output voltage and the battery voltage. -The hunting did not came about in the low rpm band. We could see from the above facts that the existence of the hunting inducing point at the con-stant voltage charging band was the direct cause of the hunting. After trying every possible means to remove the hunting inducing point we could know that the modification of the synchronous generator is suitable for he purpos in view of the small engine room.

  • PDF

Simulator Development for Training Auxiliary Power Supply in Electric Rolling Stock (전기 철도차량의 보조전원장치 실습용 시뮬레이터 개발)

  • Kim, Jae-Moon;Kim, Duk-Heon;Kim, Yuen-Chung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.192-197
    • /
    • 2005
  • This paper presents a development of the auxiliary power supply simulator for a electric rolling stock. An auxiliary power supplies are required for operating air conditioning units, ventilation fans, lighting and battery charging. Traditionally this function has been fulfilled by Motor-Alternator sets. In recent years, high performance of semiconductor and micro processor, availability and price have made three phase voltage source inverters as an attractive alternative to MA Sets. From the baseline model of the SIV(Static InVerter) for electric rolling stock, we designed the scale down model of the auxiliary power supply simulator consisting of an IGBT three phase voltage source inverter. The auxiliary power supply simulator can be used educatory purpose for training efficiently about operating principles of SIV.

A Study on the Implovement of Voltage Regulator and Electronic Control Unit for Vehicle (차량용 전자제어장치와 전압조정기 개선에 관한 연구)

  • Kim, Sun-Ho;Kim, Hyo-Sang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.11
    • /
    • pp.912-917
    • /
    • 2001
  • In this study, we define the measuring method of crank angle precisely using an event and perform a study on the hardware structure and software algorithms which is applicable for the commercial engine. Also we developed a Computer-ECU(Personal computer based electronic control unit) using a computer and a microprocessor, for performing the ignition at a desire position(angle) and for controlling a duty ratio a pulse for ISC(Idle speed control). We applied these algorithms to the modeling which is induced a concept of event and got a better result than a conventional ECU in the state of transient as a result of performing air fuel ratio control in a commercial engine. This technique can be used for the back to improve ECU performance. It the present type of Hybrid I. C voltage regulator is altered to the new type of regulator, we will be surely able to reduce the production cost as well as simplify the design of alternator\`s rear bracket and rectifier part because of the removal of trio diode. Experiment is taken by MS-R004.

  • PDF

A Study on Generating efficiency of the Double Acting Stirling Engine/Generator (양방향 스털링엔진/발전기의 효율 특성 연구)

  • PARK, SEONGJE;KO, JUNSEOK;HONG, YONGJU;KIM, HYOBONG;YEOM, HANKIL;IN, SEHWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.1
    • /
    • pp.114-120
    • /
    • 2016
  • This paper describes generating efficiency characteristics of the double acting Stirling engine/generator for domestic small-scale CHP (Combined Heat and Power) system. In small distributed generation applications, Stirling engine has competition from fuel cell, microturbine and etc. In order to be economical in the applications, a long life with minimum maintenance is generally required. Free piston Stirling engine (FPSE) has no crank and rotating parts to generate lateral forces and require lubrication. Double acting Stirling engine/generator has one displacer and two power piston which are supported by flexure springs. Two power pistons oscillate with symmetric displacement and are connected with moving magnet type linear generators for power generation from PV work. In experiments, 1 kW class double acting free piston Stirling engine/generator is fabricated and tested. Heat is supplied to hot end of engine by the combustion of natural gas and converted to electric power by linear generators which are assembled with power pistons. The electric parameters such as voltage, current and phase are measured with for variable flow rate of fuel gas. Especially, generating efficiency of FPSE is measured with three different measurement methods. Generating efficiency of the double acting Stirling engine/alternator is about 24%.

A Study on a Rotor Position Sensor Offset Detection Method in a Permanent Magnet Synchronous Generator (영구자석형 동기발전기의 회전자 위치검출 센서의 옵셋 검출에 관한 연구)

  • Park, Kyusung;Shin, Sung-Hwan;Lee, Hokwang;Yoon, Youngdeuk;Lee, Geunho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.9
    • /
    • pp.914-921
    • /
    • 2014
  • In this paper, an algorithm is suggested to detect an offset angle of the absolute rotor position sensor after the initial assembly of a PMSG. Unlike previous studies in a stationary state, this one is not designed to detect an electrical angle but rather the absolute position of the rotor is detected while operating the generator. Also,a position sensor, current sensors and voltage sensor were used to ensure reliability. This technique completes the detection of the sensor offset in two steps. In the first step, a zero-crossing of the EMF is measured using a voltage sensor to detect the electrical angle offset when the alternator is actuated by the engine. In the second step, a high frequency current is injected along the d-axis on-line during the control of the generation, eventually to obtain the inductance using a DFT (Discrete Fourier Transform), and then to ultimately extract the final electrical angle offset through the comparison of the inductance magnitude. The suggested algorithm was validated with PSIM simulation and, furthermore, was tested with actual experiments on a dynamometer.

Development of Battery Equalizer for Commercial Vehicle (상용차용 배터리 이퀄라이저 개발)

  • Choi, Deok-Kwan;Kim, Jong-Cheol;Kim, Ho-Sik;Park, Jae-Kyu
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.342-344
    • /
    • 2008
  • 24V DC power system of commercial vehicle includes 28V alternator and 24V battery bank (two 12V battery bank in series). BEQ(Battery Equalizer) provides efficient and reliable 12V DC power to 12V electrical load in 24V DC power system. In addition to providing 12V DC power, BEQ ensures that battery voltages remain equal which extends battery life. It is the most cost effective and efficient solution for dual voltage systems. BEQ made by Hyundai MOBIS is specifically designed to provide reliable 12V DC power for 12V ABS(Anti-lock Brake system).

  • PDF

Novel Estimation Technique for the State-of-Charge of the Lead-Acid Battery by using EKF Considering Diffusion and Hysteresis Phenomenon (확산 및 히스테리시스 현상을 고려한 확장칼만필터를 이용한 새로운 납축전지의 충전상태 추정방법)

  • Duong, Van-Huan;Tran, Ngoc-Tham;Park, Yong-Jin;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.139-148
    • /
    • 2014
  • State-of-charge (SOC) is one of the significant indicators to estimate the driving range of the electric vehicle and to control the alternator of the conventional engine vehicles as well. Therefore its precise estimation is crucial not only for utilizing the energy effectively but also preventing critical situations happening to the power train and lengthening the lifetime of the battery. However, lead-acid battery is time-variant, highly nonlinear, and the hysteresis phenomenon causes large errors in estimation SOC of the battery especially under the frequent discharge/charge. This paper proposes a novel estimation technique for the SOC of the Lead-Acid battery by using a well-known Extended Kalman Filter (EKF) and an electrical equivalent circuit model of the Lead-Acid battery considering diffusion and hysteresis characteristics. The diffusion is considered by the reconstruction of the open circuit voltage decay depending on the rest time and the hysteresis effect is modeled by calculating the normalized integration of the charge throughput during the partial cycle. The validity of the proposed algorithm is verified through the experiments.