• 제목/요약/키워드: alternative refrigerant

검색결과 201건 처리시간 0.026초

R435A를 적용한 정수기 냉동시스템의 성능평가 (Performance Evaluation of R435A on Refrigeration System of Water Purifiers)

  • 이요한;강동규;최현주;정동수
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.15-23
    • /
    • 2013
  • In this study, thermodynamic performance of R435A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 20%R152a/80%RE170 using actual domestic water purifiers. This mixture is numbered and listed as R435A by ASHRAE recently. Test results show that the system performance with R435A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R435A is 11.8% lower than that of HFC134a. The compressor discharge temperature of R435A $8^{\circ}C$ lower than that of HFC134a at the optimum charge. Overall, R435A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

대체냉매 R430A를 적용한 정수기 냉동시스템의 성능 평가 (Performance of R430A on Refrigeration System of Domestic Water Purifiers)

  • 박기정;이요한;정동수;김경기
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.109-117
    • /
    • 2009
  • In this study, thermodynamic performance of R430A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 76%R152a124% R600a using actual domestic water purifiers. This mixture is numbered and listed as R430A by ASHRAE recently. Test results show that the system performance with R430A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R430A is 13.4% lower than that of HFC 134a. The compressor dome and discharge temperatures and condenser center temperature of R430A are very similar to those of HFC134a at the optimum charge. Overall, R430A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

암모니아 대체 자연냉매를 이용하는 2단압축 1단팽창 냉동시스템의 성능예측 (Performance Analysis of 2-Stage Compression and 1-Stage Expansion Refrigeration System using Alternative Natural Refrigerants)

  • 노건상
    • 한국가스학회지
    • /
    • 제16권3호
    • /
    • pp.42-47
    • /
    • 2012
  • 본 논문에서는 규제 프레온냉매 R22의 대체 자연냉매의 후보인 R290(프로판), R600(부탄), R717(암모니아), R1270(프로필렌)을 작동유체로 사용하는 2단압축 1단팽창 냉동시스템의 성능 특성을 비교하였다. $-20^{\circ}C{\sim}-50^{\circ}C$ 정도의 저온을 얻기 위해 사용되는 2단압축 1단팽창 냉동장치에서의 증발온도, 응축온도, 과열도 및 과냉각도의 변화에 따른 성능계수(COP) 변화를 규명하고자 하였다. 성능특성 규명 결과, 과냉각도 및 중간냉각기에서의 냉매유량 증가에 따라 시스템의 COP는 증가하였으나, 증발온도, 응축온도 및 과열도가 증가할수록 COP는 저하되는 결과를 나타내었다. 또한, 자연냉매를 사용하는 2단압축 1단팽창 냉동시스템의 COP는 규제 프레온냉매 R22를 사용하는 경우보다 높기 때문에 자연냉매를 사용하고자 하는 냉동시스템의 안전성이 확보되면 충분히 대체 냉매로서의 경쟁력이 있을 것으로 판단되었다.

자동차 공조기용 R12 및 R134a 대체 냉매의 성능평가 (Performance of Alternative Refrigerants for R12 and R134a in Automobile Air-Conditioners)

  • 백인철;박기정;심윤보;정동수
    • 설비공학논문집
    • /
    • 제19권5호
    • /
    • pp.403-410
    • /
    • 2007
  • In this study, natural refrigerants and their mixtures that can supplement and replace R12 and R134a in automobile air-conditioners are studied. R134a is currently used as the refrigerant in new motor vehicle air conditioners, replacing the ozone depleting refrigerant R12. Although R134a has no ozone depletion potential, it has a relatively large global warming potential, approximately 1300 times that of $CO_2$ over a 100 year time horizon. For this reason, performance of natural refrigerants and their mixtures containing R152a, RE170 (Dimethylether, DME) and R600a (Isobutane) are measured under 2 different temperature conditions. They were tested in a refrigerating bench tester with an open type compressor. The test bench provided about 4 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. Test results show that the coefficient of performance (COP) of these refrigerants is up to 21.55% higher than that of R12 in all temperature conditions. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for automobile air-conditioners.

내부열교환기와 TXV를 적용한 자동차용 공조시스템의 성능에 관한 수치적 연구 (Simulation on the performance of an automobile climate control system with Internal heat exchanger and TXV)

  • 박차식
    • 한국산학기술학회논문지
    • /
    • 제22권1호
    • /
    • pp.31-36
    • /
    • 2021
  • 최근에 지구온난화 문제로 인하여 자동차 공조시스템은 GWP 지수가 높은 R134a 냉매를 대체할 수 있는 대체 냉매를 적용하고 있다. 본 연구에서는 R1234yf 냉매를 사용하여 내부열교환기와 가면용량형 팽창밸브인 TXV를 적용한 자동차 공조시스템의 성능특성을 해석하였다. 상용 소프트웨어인 Amesim을 이용하여 주요 부품인 압축기, 응축기, 팽창장치, 증발기와 내부열교환기를 모델링을 하여 외기온도와 응축기 휜 피치 변화에 따른 냉동사이클 시뮬레이션을 수행하였다. 외기온도가 30℃에서 40℃로 증가함에 따라 시스템의 냉방용량은 3.1% 감소하고, 압축기 소비동력은 17.1% 증가하였다. 또한, 응축기의 휜 피치를 0.8 mm에서 1.4 mm로 증가시키면서, 사이클 성능특성을 해석하였다. 휜 피치가 1.0 mm 클 경우에 응축기의 방열량은 감소하였고, COP는 5.9% 까지 감소하였다. 응축기 휜 피치가 1.0 mm 보다 작은 0.8 mm에서는 시스템 성능에 큰 변화가 없어 휜 피치 1.0 mm에서 최적의 성능을 나타내는 것으로 분석되었다.

Performance of Alternative Refrigerants in Low Temperature Chillers

  • Jung, Dong-Soo;Kim, Chong-Bo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.67-79
    • /
    • 1998
  • This paper is about the performance of alternative refrigerants for low temperature and transport refrigeration chillers. A breadboard refrigeration chiller was constructed with counterflow heat exchangers. R502, its transitional alternatives of R402A and R402B, and long-term alternatives of R404A and R507 were tested in an attempt to compare the performance of each refrigerant against R502. Measurements were conducted at two condensing temperatures of 43.3$^{\circ}C$ and 52.$0^{\circ}C$ and the evaporating temperature was varied over a range from -$25^{\circ}C$ to -5$^{\circ}C$. The evaporator superheat and condenser subcooling were maintained constant at about 5$^{\circ}C$ for all tests. Test results showed that all alternative fluids tested in this work can be used as 'drop-in fluids' to replace R502 without any major problem. It is also found that in the long run HFC alternatives are to be used due to their favorable environmental characteristics and better performance.

  • PDF

대체 프레온계 냉매를 이용하는 이원 냉동시스템의 성능예측 (Prediction on Performance of Cascade Refrigeration System using Alternative Freon Refrigerants)

  • 노건상
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.73-79
    • /
    • 2011
  • In this paper, cycle performance analysis of cascade refrigeration system using alternative FREON refrigerants are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and evaporating and condensing temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. Therefore, subcooled degree, evaporating and condensing temperature of cascade heat exchanger using alternative FREON refrigerants have an effect on the COP of this system. In this paper, COP of cascade refrigeration system using R23 for low temperature system and R507A for high temperature system is higher 8 ~ 29 % than using R13 for low temperature system and R22 for high temperature system.

내경 6 mm 평관과 마이크로 핀관 내에서 R22 대체냉매의 흐름응축 열전달계수 (Flow Condensation Heat Transfer Coefficients of R22 Alternative Refrigerants in Plain and Microfin Tubes of 6.0 mm Inside Diameter)

  • 박기호;서영호;박기정;정동수
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.444-451
    • /
    • 2004
  • Flow condensation heat transfer coefficients (HTCs) of R22, R134a, R407C, and R410A were measured on horizontal plain and microfin tubes. The experimental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water/glycol loop. The test section in the refrigerant loop was made of both a plain and a microfin copper tube of 6.0∼6.16 mm inside diameter and 1.0 m length. Refrigerants were cooled by passing cold water through an annulus surrounding the test section. Tests were performed at a fixed refrigerant saturation temperature of 4$0^{\circ}C$ with mass fluxes of 100, 200, and 300 kg/m2s. Test results showed that at similar mass flux the flow condensation HTCs of R134a were similar to those of R22 for both plain and microfin tubes. On the other hand, HTCs of R407C were lower than those of R22 by 4∼16% and 16∼42% for plain and microfin tubes respectively. And HTCs of R410A were similar to those of R22 for a plain tube but lower than those of R22 by 3∼9% for a microfin tube. Heat transfer enhancement factors of a microfin tube were 1.3∼1.9.

냉동${\cdot}$공조용 로터리 콤프레서의 윤활 특성 제2보:베인 선단부의 탄성 유체 윤활 특성 해석 (The lubrication Characteristics of a Rotary Compressor used for Refrigeration and Air-conditioning Systems Park II: Analysis of elastohydrodynamic lubrication on vane tip)

  • 조인성;오석형;정재연
    • Tribology and Lubricants
    • /
    • 제13권1호
    • /
    • pp.62-69
    • /
    • 1997
  • Rapid increase of refrigeration and air-conditioning systems 9r & a systems) in modern industries brings attention to the urgency of research & development as a core technology in the area. And it is required to the compatibility problem of r & a systems to alternative refrigerant for the protection of environment. The, it is requested to study the lubrication characteristics of refrigerant compressor which is the core technology in the r & a systems. The study of lubrication characteristics in the critical sliding component is essential for the design of refrigerant compressor. Therefore, theoretical investigation of the lubrication characteristics of rotary compressor for r & a systems is studied. The newton-Raphson method is used for the EHL analysis between vane and rolling piston in the rotary compressor. The results show that the rotational speed of a shaft and the discharge pressure influence significantly the friction force between vane and rolling piston. This results give important basic data for the further lubrication analysis and design of a rotary compressor.

냉동, 공조용 로터리 콤프레서의 윤활 특성 제1보;롤링 피스톤의 거동해석 (The Lubrication Characteristics of Rotary Compresssor for refrigeration & air-conditioning (Part I; The analysis of Rolling Piston behavior ))

  • 조인성;김진문;백일현;정재연
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1996년도 제23회 학술대회
    • /
    • pp.7-16
    • /
    • 1996
  • Rapid increase of refrigeration & air-conditioning system( r & a system ) in modern industries brings attention to the urgency of development as a core technology in the area. And it required to the compatibility problem of r & a system to alternative refrigerant for the protection of environment. Then, it is requested to research about the lubrication characteristics of refrigerant compressor which is the core thechnology in the r & a system. The study of lubrication characteristics in the critical sliding component is essential for the design of refrigerant compressor. Therefore, theoetical investigation of the lubrication characteristics of rotary compressor for r & a system is studied. And the Runge-Kutta method is used for the analysis of the behavior of rolling piston in the rotary compressor. The results show that the rotating speed of shaft and the discharge pressure have an important effect upon the angular velocity of the rolling piston. This results give important basic data for the further lubrication analysis and design of the rotary compressor.

  • PDF