열펌프를 이용한 R22대체 혼합냉매의 성능에 관한 연구 (A Study on the Performance of HCFC22 and Alternative Refrigerants in Heat Pumps)

  • 송영재;정동수
    • 태양에너지
    • /
    • 제18권1호
    • /
    • pp.69-79
    • /
    • 1998
  • This paper is concerned about the performance of HCFC22 alternative refrigerants used in heat pumps and industrial chillers. A water-to-water breadboard heat pump with counter-current heat exchangers and a hermetic compressor was built to carry out the experiments with various refrigerants. For each test, more than 40 temperatures, 4 pressures, power input, mass flow rates of the heat transfer fluids were measured. Refrigerants tested were HCFC22, R290(Propane), an azeotrope of 45%Propane/55%R134a mixture, and a nonazeotropic mixture of Calor 50. All tests were conducted under ARI test A condition. It is found that the COP and capacity of propane were 18% and 2.5% higher than those of HCFC22 while the COP and capacity of 45%Propane/55%R134a mixture were 3.5% and 5.3% higher than those of HCFC22 respectively. Also the COP and capacity of Calor 50 were 17% and 7.8% higher than those of HCFC22. Compressor discharge temperatures of alternative refrigerants were roughly $35^{\circ}C$ lower than that of HCFC22 indicating that these refrigerants are good from the view point of compressor reliability. The charging amounts for the alternative refrigerants were reduced by 40-60% as compared to that of HCFC22. Overall, it can be said that hydrocarbon containing alternative refrigerants are excellent in thermodynamic performance but should be used with considerable care due to their flammability.

  • PDF

R22 대체냉매를 적용한 스크롤 압축기의 누설 특성에 관한 연구 (A Study on Leakage Characteristics of a Scroll Compressor with alternative Refrigerants of R22)

  • 윤영;김용찬;민만기
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.377-387
    • /
    • 2001
  • This paper presents leakage characteristics of a scroll compressor applying alternative refrigerants of R22 such as R407c and R410a under actual operating conditions. Because leakage in a scroll compressor produce significant losses and degradation of performance, those should be clarified to design a high efficient scroll compressor with alternative refrigerants of R22. However, flank and tip leakage characteristics of a scroll compressor with alternative refrigerants are very limited in open literature. In the present study, both experimentation and modeling of the leakages in the scroll compressor were performed. As a result, it was observed that the leakages of the scroll compressor with R407c increased by 15%, and that with R410a increased by 76% as compared to the compressor applying R22 under standard load conditions due to a higher upstream pressure and a higher pressure difference between pockets.

  • PDF

실차를 이용한 자동차 에어컨 냉매 누출량 평가 (Measurement of R-134a Leakage from Vehicle Equipped Mobile Air Conditioning(MAC) System)

  • 김지영;서충열;이상은;김정수
    • 한국기후변화학회지
    • /
    • 제3권2호
    • /
    • pp.153-159
    • /
    • 2012
  • 자동차 에어컨 냉매로 사용되어온 CFC-12는 1991년부터 1994년에 걸쳐 HFC 계열의 냉매인 R134a로 대체되었으며, R-134a는 현재자동차 에어컨 냉매로 널리 사용되고 있다. 그러나 R-134a는 지구온난화 지수(GWP)가 1,300으로 매우 높으며, 교토의정서에서 정한 6대 온실가스 중에 하나로 포함되어 누출량 관리 및 대체 냉매 개발이 필요한 실정이다. 본 연구에서는 자동차에서 배출되는 $non-CO_2$ 온실가스 배출량 산출을 위한 기초연구로 실차 상태에서의 에어컨 냉매 누출량을 분석하기 위하여 가변온도밀폐실(VT shed)과 Running loss test shed를 이용하여 R-134a의 농도변화를 측정하였다. 대상차종에 대한 주차상태에서 R-134a 누출량을 분석한 결과, 연간 누출량이 6.46~13.28 g/yr 수준으로 기존의 에어컨 시스템을 이용한 누출량 분석결과와 유사한 수준으로 분석되었다. 동일 모델 차량에 단일증발기를 적용한 차량과 이중증발기를 적용한 차량에 대해 냉매 누출량을 비교한 결과, 단일증발기로 구성된 에어컨이 적용된 차량에 비하여 이중증발기가 적용된 에어컨이 장착된 차량에서 누출량이 높게 나타났다. 이는 이중증발기 적용에 따라 에어컨 시스템 구성시 연결부위(호스, 접합부 등)가 추가되면서 해당 부위에서의 누출이 증가된 것으로 보인다. 또한, 차속별 R-134a 농도변화를 분석한 결과, 고속주행시(100 km/hr) 냉매 누출이 증가하였으며, 송풍량 증가에 따른 누출량 변화는 나타나지 않았다.

A Generalized Correlation and Rating Charts for Mass Flow Rate through Capillary Tubes with Several Alternative Refrigerants

  • Choi Jong Min;Jang Yong Hee;Kim Yongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.192-197
    • /
    • 2004
  • A capillary tube, which is a common expansion device in small sized refrig-eration and air-conditioning systems, should be redesigned properly to establish an optimum operation cycle of a refrigerating system with alternative refrigerants. Based on experimental data for R-22, R-290, and R-407C, an empirical correlation is developed to predict mass flow rate through capillary tubes. Dimensionless parameters are derived from the Buckingham Pi theorem, considering the effects of operating conditions and capillary tube geometry on mass flow rate. Approximately $97\%$ of the present data are correlated within a relative deviation of $\pm\;10\%.$ The present correlation also predicts the data obtained from open literature within $\pm\;15\%.$ In addition, rating charts of refrigerant flow rate for R-12, R-22, R-134a, R-152a, R-407C, R-410A, R-290, and R-600a are developed.

R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구 (An experimental study on the performance of a window system air-conditioner using R407C and R410B)

  • 김만회;신정섭;김권진
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

대체냉매 관내 열전달특성 시험을 위한 동심이중원관의 환상유로의 열전달계수 (Heat Transfer Coefficients of Concentric Annuli for Testing Heat Transfer Characteristics of Alternative Refrigerants in Tubes)

  • 김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제32권1호
    • /
    • pp.63-67
    • /
    • 2021
  • Accurate measurements of the heat transfer coefficients of concentric annular space for the test section is important to measure the tube-side heat transfer coefficients of working fluids. This paper presents the annular side heat transfer coefficients of concentric annuli with variation of tube diameter ratios using Wilson plot method. The test facility has a straight, horizontal test section with an active length of 3.0 m. Inner/outer diameters of test tubes are 7.0/7.5 and 8.0/8.56 mm, respectively. An outer diameter of annulus side is 16.0 mm. The test results show that convective heat transfer coefficients in annuli increase with annular diameter ratio. The correlations for convective heat transfer coefficients in annuli are also developed.

다양한 냉매를 적용한 내부열교환기 부착 2단 압축 냉동시스템의 성능 분석 (Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants)

  • 윤정인;허성관;제재면;전민주;손창효;문정현
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.82-88
    • /
    • 2015
  • In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system applied various refrigerants is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporation temperature, condensing temperature, mass flow rate ration into inter-cooler, effectiveness of internal heat exchanger. The main results were summarized as follows : The COP of two-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling, mass flow rate ration of inter-cooler, evaporation temperature, but decreases with the increasing condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and 1-stage expansion using substitute refrigerant have an effect on COP of this system. The COP of alternative refrigerants was higher than the COP of R22 in this study, although the COP of some mixed refrigerants were lower than COP of R22.

R1234yf와 R1234yf/R134a의 자동차 에어컨 작동 조건에서의 성능 평가 (Performance of R1234yf and R1234yf/R134a Mixture under Mobile Air-conditioner Operating Conditions)

  • 박기정;이요한;최대성;정동수
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.837-844
    • /
    • 2010
  • In this study, performance of R1234yf and R1234yf/R134a mixture is measured on a heat pump bench tester in an attempt to substitute R134a used widely in mobile air conditioners (MACs). The bench tester is equipped with a open type compressor providing a nominal capacity of 3.5 kW. All tests are conducted under the summer cooling and winter heating conditions of 7/4 $5^{\circ}C$ and $-7/41^{\circ}C$ in the evaporator and condenser, respectively. For R1234yf/R134a mixture, measurements are made at 5%, 10%, and 15% of R134a by mass. Test results show that the coefficient of performance (COP) and capacity of R1234yf are up to 2.7% and 4.0% lower than those of R134a, respectively. For R1234yf/R134a mixture, the COP and capacity are up to 3.9% lower and 3.6% higher than those of R134a. For R1234yf and R1234yf/R134a mixture, the compressor discharge temperature is $4.1{\sim}6.7^{\circ}C$ lower than that of R134a while the amount of charge is reduced up to 11% as compared to R134a. 90%R1234yf/10%R134a is a better refrigerant than pure R1234yf in that it is less flammable and more compatible with existing R134a system. Based upon the results, it is concluded that R1234yf and R1234yf/R134a mixture are long term environmentally friendly solutions to mobile air-conditioners due to their excellent environmental properties with acceptable performance.

친환경 냉매 제조를 위한 오불화프로펜 수소화반응에 대한 예측 (Prediction of Reaction Performance of Pentafluoropropene Hydrogenation for Environmentally Friendly Refrigerant Production)

  • 윤미희;유계상
    • 공업화학
    • /
    • 제27권6호
    • /
    • pp.573-576
    • /
    • 2016
  • 친환경 냉매인 R-1234yf를 제조하기 위하여 오불화프로펜인 1,2,3,3,3-pentafluoropropene의 수소화반응을 수행하였다. 수소화반응 촉매로 팔라듐이 담지된 탄소입자를 제조하여 실험에 사용하였다. 반응조건에 따른 수소화반응 활성을 규명하기 위하여 WHSV, 반응온도 및 반응물의 조성에 따른 반응성능에 대하여 조사하였다. 일정한 실험 조건에서 WHSV는 주 생성물의 선택도에 영향이 없으며, 반응온도의 경우 높은 온도에서 우수한 생성물 선택도를 보였다. 수소와 반응물의 비의 경우 1.5 미만에서 우수한 생성물 선택도를 보였다. 또한 반응조건에 따른 생성물의 수율을 예측할 수 있는 모델식을 통계학적 접근을 통해 완성하였다.

Scuffing and Wear of the Vane/Roller Surfaces for Rotary Compressor Depending on Several Sliding Condition

  • Lee, Y.Z.;Oh, S.D.;Kim, J.W.;Kim, C.W.;Choi, J.K.;Lee, I.J.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.227-228
    • /
    • 2002
  • One of the serious challenges in developing rotary compressor with HFC refrigerant is the prediction of scuffing times and wear amounts between vane and roller surface. In this study, the tribological characteristics of sliding surfaces using roller-vane geometry of rotary compressor were investigated. The sliding tests were carried out under various sliding speeds, normal loads and surface roughness. During the tests, friction force, wear scar width, time to failure, surface temperature, and surface roughness were monitored. Because severe wear was occurred on vane surface, TiN coating was applied on sliding surfaces to prolong the wear-life of vane-roller interfaces. From the sliding tests, it was found that there was the optimum initial surface roughness to break in and to prolong the wear life of sliding surfaces. Depending on load and speed, the protective layers, which were composed of metallic oxide and organic compound, were formed on sliding surfaces. Those would play an important role in the amount of friction and wear between roller and vane surfaces.

  • PDF