• Title/Summary/Keyword: alternating method

Search Result 433, Processing Time 0.031 seconds

Constant amplitude fatigue test of high strength bolts in grid structures with bolt-sphere joints

  • Yang, Xu;Lei, Honggang
    • Steel and Composite Structures
    • /
    • v.25 no.5
    • /
    • pp.571-579
    • /
    • 2017
  • The grid structure with bolt-sphere joints is widely adopted by industrial plants with suspending crane. The alternating reciprocating action of the suspending crane will cause fatigue problems of the grid structure with bolt-sphere joints with respect to the rod, the cone, the sealing plate, the bolt ball and the high strength bolt; while the fatigue of the high strength bolt is the key issue of fatigue failure. Based on efficient and smooth loading equipment with the AMSLER fatigue testing machine, this paper conducted a constant amplitude fatigue test on 18 M20 and 14 M30 high strength bolts with 40Cr material, and obtained 19 valid failure points, 9 unspoiled points with more than 2 million cycles, and 4 abnormal failure points. In addition, it established the constant amplitude fatigue design method, ${[{\Delta}{\sigma}]_{{2{\times}10}}{^6=58.91MPa}$, and analyzed the stress concentration and the fatigue fracture of high strength bolts. It can be explained that the geometrical stress concentration of high-strength bolt caused by spiral burr is severe.

Bioelectrical Impedance Analysis at Inner Forearms of the Human Body using Bioelectrical Impedance Measurement System

  • Kim, Jae-Hyung;Kim, Soo-Hong;Baik, Sung-Wan;Jeon, Gye-Rok
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.7
    • /
    • pp.1146-1153
    • /
    • 2016
  • The bioelectrical impedance (BI) at the inner forearms was measured using bioelectrical impedance measurement system (BIMS), which employs the multi-frequency and the two-electrode method. Experiments were performed as follows. First, while applying a constant alternating current of 800A to the inner region of the forearms, BI (Z) was measured at nineteen frequencies ranging from 5 to 500 kHz. The prediction marker (PM) was calculated for right and left forearm. The resistance (R) and the reactance (Xc) were simultaneously measured during impedance measurement. Second, a Cole-Cole plot (relationship between reactance and resistance) was obtained for left and right forearm, indicating the different characteristic frequencies (fc). Third, the phase angle was obtained, indicating strong dependence on the applied frequency.

Palaeomagnetism of Tertiary Basins in Southern Korea : 3. Chongja-Ulsan Basins and its Vicinities (남한 제3기 분지지역에 대한 고자기 연구 : 3. 정자-울산분지와 그 일원)

  • Son, Moon;Kang, Hee-Cheol;Kim, In-Soo
    • Economic and Environmental Geology
    • /
    • v.29 no.4
    • /
    • pp.509-522
    • /
    • 1996
  • A total of 460 palaeomagnetic samples was collected from the Tertiary Chongja-Ulsan basins and surrounding area in the southeastern part of Korean peninsula. All samples were stepwise demagnetized by either alternating field or thermal method. It was found that most sample-sites have ChRM declination which has been rotated clockwise from the north-south reference direction of Tertiary East Asia, although other two extrusive sample-sites within the Chongja sedimentary basin show counterclockwise rotation of ChRM declination. Fold tests for the site-mean ChRMs of the latter two sites reveal insignificant result and negative result with 95% confidence level, respectively. The amount of the clockwise deflection of declination varies from about $20^{\circ}$ upto about $80^{\circ}$ according to the block to which each sample-site belongs. The amount of the counterclockwise deflection is about $20^{\circ}$. It is concluded that the clockwise ChRM rotation has been caused by dextral simple shearing accompanied by NNW-SSE spreading of the East Sea which has been active until about 16Ma, and that the counterclockwise rotation is a result of sinistral simple shearing associated with WNW-ESE contraction in the Korean Strait-SW Japan region at about 15 Ma.

  • PDF

Microstructure of Intermixed $Zn_{1-x}Fe_xSe$ Alloys in (ZnSe/FeSe) Superlattices ((ZnSe/FeSe) 초격자에 있어서 $Zn_{1-x}Fe_xSe$ 상호확산층의 미세구조)

  • Park, Kyeong-Soon
    • Applied Microscopy
    • /
    • v.27 no.3
    • /
    • pp.235-241
    • /
    • 1997
  • The microstructure of intermixed $Zn_{1-x}Fe_xSe$ layers in the (ZnSe/FeSe) superstrates grown on (00l) GaAs substrates has been investigated by high -resolution transmission electron microscopy and computer simulations of lattice images. Computer image simulations have been performed by the multislice method under various sample thicknesses and defocusing conditions. The simulated lattice images were compared with the experimental lattice images. Also, CuAu-I type ordering was often observed in the intermixed $Zn_{1-x}Fe_xSe$ alloys. This CuAu-I type ordered structure consists of alternating ZnSe and FeSe monolayers along the <100> and <110> directions.

  • PDF

Effects of Baffle Location on the Performance of a Super Compact Condenser in an Automotive Air Conditioning System (자동차용 에어컨의 고밀도 응축기(SCC)에서 배플의 위치 변화에 따른 성능향상에 관한 연구)

  • 이명재;박복춘;백병준;염동석;한창섭
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.128-140
    • /
    • 1997
  • A new super compact condenser(SCC), which has been developed recently is especially suitable for an alternative refrigerant HFC-134a due to its high performance and compactness. The SCC is composed of two pipe headers, baffles, narrow multi-rectangular channels, and louvered fin arrays. Alternating inlet and outlet by the inserted baffles in pipe headers guide refrigerant to and from the narrow multi-rectangular channels. Since the flow rate and its lengh are changed depending on the number and location of baffles, the corresponding pressure drop and heat transfer rate are changed. The present study aims to theoretically and experimentally investigate the effects of baffle location and its number on the pressure drop and thermal performance of the SCC with 40 multi-rectangular channels. The results show that the present method provides an acceptable prediction of pressure drop and heat transfer rate for a 4 pass SCC. However, the model significantly under predicts the performance of a 3 pass SCC, which may be attributed to the phase separation of refrigerant flowing through header pipes. Pressure drop is more signifi- cantly influenced than heat transfer rate by the baffle location.

  • PDF

Hybrid Square-Lattice Photonic Crystal Fiber with Broadband Single-Mode Operation, High Birefringence, and Normal Dispersion

  • Kim, Soeun;Lee, Yong Soo;Lee, Chung Ghiu;Jung, Yongmin;Oh, Kyunghwan
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.449-455
    • /
    • 2015
  • In this study we propose a new photonic crystal fiber (PCF) design that simultaneously offers broadband single-mode operation, high birefringence, and large normal dispersion in the optical-communication wavelength regime. The waveguide is based on a hybrid square-lattice PCF (HS-PCF) that has circular air holes of two different diameters alternating in the cladding, plus a pure silica defect at the center. The optical properties of the guided modes are analyzed numerically by the finite-element method (FEM) with a perfectly matched layer as the boundary condition. The optimized HS-PCF has a dispersion coefficient of $-601.67\;ps\;nm^{-1}\;km^{-1}$ and a high birefringence of $1.025{\times}10^{-2}$ at $1.55{\mu}m$. In addition, over the S+C+L+U wavelength bands the proposed HS-PCF with ultraflat birefringence with a slope on the order of $10^{-5}$.

Chemical-assisted Ultrasonic Machining of Glass by Using HF Substitute Solution (불산대체용액을 이용한 유리의 초음파 가공)

  • 전성건;남권선;김병희;김헌영;전병희
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.262-267
    • /
    • 2004
  • Ultrasonic machining has been known as one of the conventional machining methods in the glass fabrication processes. In ultrasonic machining, typically, glass is removed by the impulse energy of the abrasive generated by the ultrasonic power. However, when the machining feature decrease under hundreds of micrometers, as conventional ultrasonic machining uses only the impulse energy of the abrasive, the speed of ultrasonic machining decreases significantly and the surface roughness becomes deteriorated. To overcome this size effect, the chemicals which can erode glasses, such as HF, XF, etc, are added to the slurry. The chemical-assisted ultrasonic machining method, so called, is another alternating effective way for micro machining of glasses. In previous work, we used the hydrofluoric acid (HF) as an additive chemical. But, as the HF solution is too poisonous to be used as a ultrasonic process additive, it is needed to be substituted by other safe chemicals. As results of the machinability comparison of several chemicals, the GST-500F was selected to replace the HF. The GST-500F (pH $4.0{\pm}1.0$) is non-volatile, odorless. During experimental works, it was shown that the machining rate increases 1.5 times faster than the conventional ultrasonic machining. The machining load also decreases. However, the enlargement of the hole diameter and significant tool wear are still the problems to be solved.

Traction Effects for the Treatment of Scoliosis (척추 측만증에 대한 견인 치료의 효과)

  • Shim, Jae-Hun;Oh, Duck-Won
    • Physical Therapy Korea
    • /
    • v.3 no.3
    • /
    • pp.12-23
    • /
    • 1996
  • The purpose of this research is to identify traction effects for the treatment of scoliosis and compare the effects among patients as their own physical characters. In this research, the patients with scoliosis hospitalized for ten days have treated in the way of the static traction for twenty hours a day, and alternating lumbar and cervical traction for twenty minutes two times a day in the department of rehabilitaton of Yong-Dong Severance Hospital. The followings are the conclusions of this research: 1) The traction for the patients with scoliosis is effective treatment method to reduce the curved angle (p<0.001). 2) Statistically there is no significant difference of the reduced curved angle between male and female after the traction (P>0.05). 3) Statistically there is significant difference of the reduced curved angle among age groups after the traction (P<0.05). 4) Statistically there is significant difference of the reduced curved angle among curved angle groups after the traction (p<0.001). 5) Statistically there is no significant difference of the reduced curved angle among shapes of curved angle after the traction (P>0.05).

  • PDF

Determination of Strongly Interacting Spin Exchange Path and Spin Lattice Model of (VO)2(H2O){O3P-(CH2)3-PO3}ㆍ2H2O on the Basis of Spin Dimer Analysis

  • Kim, Dae-Hyun;Koo, Hyun-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1665-1668
    • /
    • 2010
  • The spin exchange interactions of $(VO)_2(H_2O){O_3P-(CH_2)_3-PO_3}{\cdot}2H_2O$ were examined by spin dimer analysis based on extended Huckel tight binding method. The strongest spin exchange interaction occurs through the super-superexchange path $J_2$ and the second strongest spin exchange interaction occurs through the superexchange interaction path $J_1$. There are two strongly interacting spin exchange paths in $(VO)_2(H_2O){O_3P-(CH_2)_3-PO_3}{\cdot}2H_2O$. Therefore, magnetic susceptibility curve of $(VO)_2(H_2O){O_3P-(CH_2)_3-PO_3}{\cdot}2H_2O$ can be well reproduced by an alternating onedimensional antiferromagnetic chain model rather than an isolated spin dimer model.

Development of Titanium Metal Surface Anodizing Equipment (티타늄 금속 표면 양극산화장치 개발)

  • Yang, Keun-Ho;Min, Byung-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.9
    • /
    • pp.1307-1312
    • /
    • 2013
  • In this paper, alkaline or acidic solution, in particular the principle of electrolysis to oxidize the metal surface to form a device isolation film is developed. In the past, mainly in the form of pulse voltage is applied to the anode only a unipolar method, but in this paper by using the H-bridge to the amount of the positive (+) voltage and the negative supply voltage, alternating voltage polarity devices were fabricated according to the characteristics of metal specimens with different electrical conditions to form an oxide film on the device was developed. Supply current variable was used for the PWM modulation, (+) and (-) polarity change of the H-bridge bipolar pulse voltage to supply the was that. As a result, a more uniform pores with unipolar film was formed.