• 제목/요약/키워드: allowable load set

검색결과 34건 처리시간 0.032초

다물체 시스템에서의 허용하중 집합의 구현과 적용 (Construction of Allowable Load Set for Multi-body Systems and Application Cases)

  • 김재현;곽병만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.758-763
    • /
    • 2001
  • A concept called Allowable Load Set (ALS) is introduced and methods of finding its boundaries are developed. The resulting diagram allows an easy understanding of load and strength characteristics of a structure in relation to structural integrity under uncertain loading conditions. An allowable load diagram for an ALS visualizes the relation between a prescribed load and a degree of safety of the structure. During the application of the algorithms, critical areas of the structure are identified. A systematic method of finding the allowable load sets for multi-body mechanical systems is especially presented and applied to an excavator as a realistic case.

  • PDF

허용하중집합 개념을 이용한 기계/구조 시스템의 강건 설계 (Robust Design of Structural and Mechanical Systems using Concept of Allowable Load Set)

  • 곽병만
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.333-338
    • /
    • 2007
  • The concept of "Allowable Load Set (ALS)" introduced by the author allows an easy understanding of load and strength characteristics of a structure in relation to its integrity under uncertainties. Two criteria of safety are introduced: A relative safety index denotes the distance to the boundary of the ALS and a normalized safety index is a distance in terms of functional value. They have been utilized in several examples, including multi-body mechanical systems such as a biomechanical system. Both formulations amount to robust designs in the sense that designs most insensitive to uncertainties are obtained in the context of newly defined safety indices, without using any input probability information.

  • PDF

성토지반에 타입된 H형강 말뚝의 지지거동 (Bearing Capacity of Driven H-Piles in Embankment)

  • 박영호;정경자;김성환;유성근;이재혁;박종면
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.173-182
    • /
    • 2000
  • To find axial and lateral responses of impact-driven H piles in embankment(SM), the H piles are instrumented with electric strain gages, dynamic load test is performed during driving, and then the damage of strain gages is checked simultaneously. Axially and laterally static load tests are performed on the same piles after one to nine days as well. Then load-settlement behavior is measured. Furthermore, to find the set-up effect in H pile, No. 4, 16, 26, and R6 piles are restriked about 1, 2, and 14 days after driving. As results, ram height and pile capacity obtained from impact driving control method become 80cm and 210.3∼242.3ton, respectively. At 15 days after driving, allowable bearing capacity by CAPWAP analysis, which 2.5 of the factor of safety is applied for ultimate bearing capacity, increases 10.8%. Ultimate bearing capacity obtained from axially static load test is 306∼338ton. This capacity is 68.5∼75.7% at yield force of pile material and is 4∼4.5 times of design load. Allowable bearing capacity using 2 of the factor of safety is 153∼169ton. Initial stiffness response of the pile is 27.5ton/mm. As the lateral load increases, the horizontal load-settlement behaves linearly to which the lateral load reaches up to 17ton. This reason is filled with sand in the cavity formed between flange and web during pile driving. As the result of reading with electric strain gages, flange material of pile is yielded at 19ton in horizontal load. Thus allowable load of this pile material is 9.5ton when the factor of safety is 2.0. Allowable lateral displacement of this pile corresponding to this load is 23∼36mm in embankment.

  • PDF

궤도 및 교량 안전성을 고려한 열차 증속가능 속도대역 평가 (Evaluation on Allowable Vehicle Speed Based on Safety of Track and Railway Bridge)

  • 방은영
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.145-151
    • /
    • 2018
  • In this study, the track-bridge interaction analysis was performed using an analytical model considering the track structure, thereby taking into account the linear conditions (R=650 m, cant variation $160{\pm}60mm$) and the dynamic characteristics of the bridge. As a result of the study, the allowable speed on the example bridge considered was calculated at 200 km/h based on vertical deflection, vertical acceleration, and irregularity in longitudinal level, but was also evaluated at 170km/h based on the coefficient of derailment, wheel load reduction, and lateral displacement of the rail head. It is considered desirable to set the speed 170km/h to the speed limit in order to secure the safety of both the bridge and the track. It is judged that there will be no problems with ensuring rail protection and train stability in the speed band.

Minimum-weight design of non-linear steel frames using combinatorial optimization algorithms

  • Hayalioglu, M.S.;Degertekin, S.O.
    • Steel and Composite Structures
    • /
    • 제7권3호
    • /
    • pp.201-217
    • /
    • 2007
  • Two combinatorial optimization algorithms, tabu search and simulated annealing, are presented for the minimum-weight design of geometrically non-linear steel plane frames. The design algorithms obtain minimum weight frames by selecting suitable sections from a standard set of steel sections such as American Institute of Steel Construction (AISC) wide-flange (W) shapes. Stress constraints of AISC Load and Resistance Factor Design (LRFD) specification, maximum and interstorey drift constraints and size constraints for columns were imposed on frames. The stress constraints of AISC Allowable Stress Design (ASD) were also mounted in the two algorithms. The comparisons between AISC-LRFD and AISC-ASD specifications were also made while tabu search and simulated annealing were used separately. The algorithms were applied to the optimum design of three frame structures. The designs obtained using tabu search were compared to those where simulated annealing was considered. The comparisons showed that the tabu search algorithm yielded better designs with AISC-LRFD code specification.

하중-저항계수 설계법과 허용응력 설계법에 의한 강교량 주부재의 최적화 설계 (Optimum Design of I-Type Girders in Steel Bridges by LRFD and ASD)

  • 안성욱;신영석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.183-190
    • /
    • 1998
  • In this study, I-type girders, main members of a steel composite bridge, are designed by Load and Resistance Factor Design method as well as Allowable Stress Design method. The width, height web thickness and flange thickness of main girders are set as design variables. The design program connects optimization program ADS, which is coded with FORTRAN, and a main program coded with $C^{++}$. In this study, it is shown that in this particular steel composite bridge, the design by The Load and Resistance Factor Design method is more economical than that by The Allowable Stress Design method.d.

  • PDF

S.I.G 공법으로 선단보강된 강관말뚝의 지지거동 (The Behavior of Bearing Capacity of Steel Pipe Piles Reinforced by Super Injection Grouting at Pile Tip)

  • 박영호;김낙영;육정훈;최진오
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.20-27
    • /
    • 2004
  • Reinforced twice than width of foundation with SIC under steel piles drived in cohesion soil and in the coal-limestone which heavily fractured. To analyze behaviour characteristic of steel piles, load transfer test was performed to steel piles attached with strain gauges to axial direction. After it passed 49days, dynamic load test was performed to set-up effect of steel piles bearing capacity. The results of test were compared to each other. According to the results, as the skin friction of steel pile was on the same condition, end bearing capacity of steel piles established on SIC solid of cemented milk in cohesion soil was three times than steel piles established on SIG solid of cemented milk in heavily fractured coal- limestone. After piles were driven and passes 49days, in case of piles on SIG solid of comented milk in cohesion soil the increaes of allowable bearing capacity was 442.9% and allowable bearing capacity of piles on SIG solid of cemented milk in heavily fractured coal-limestone increased 22.4%.

  • PDF

직관 지지대 설치 기준의 L형관 설계 적용 가능성에 관한 연구 (Applicability of Supporting Standard for a Straight Pipe System to an Elbow)

  • 한상규;이재헌
    • 플랜트 저널
    • /
    • 제8권2호
    • /
    • pp.52-58
    • /
    • 2012
  • Pipe means the connection of the tube in order to transfer fluid from one device to another device. The piping stress analysis is to analyze the structural stability considering the location and the features of piping support after completing the piping design, The allowable stresses comply with the requirements of the relevant standards by examining whether the support of the function and location of pipe or re-operation is confirmed. Allowable stresses are to make sure that the maximum stress should not exceed the allowable stress presented in the ASME B31.1 POWER PIPING code. ASME B31.1 POWER PIPING code ensures a smooth stress analysis can be performed during the initial pipe stress analysis as provided in the case of straight pipe to the horizontal distance between the supports. However, because there is no criteria set in the case of curved pipe, the optimum pipe supporting points were studied in this paper. As mentioned about the curved pipe, loads applied to the support of the position of 17% and 83% of the position relative to the elbow part have results similar to the load acting on the support of straight pipe.

  • PDF

고속철도 레일 표면 결함 관리기준에 관한 연구 (Investigation of the Maintenance Criteria for the Rail Surface Defects in High-Speed Railways)

  • 양신추;장승엽
    • 한국철도학회논문집
    • /
    • 제14권6호
    • /
    • pp.535-544
    • /
    • 2011
  • 레일 표면 결함이 발생할 경우 매우 높은 충격하중이 발생하여 레일 피로 진전 또는 레일 파단에 이를 수 있고 레일이 파단될 경우 열차탈선 등 대형 사고가 발생할 수 있으므로 레일 결함부에 대한 관리기준의 정립이 매우 중요하다. 본 연구에서는 차량-궤도 동적 상호작용 해석 프로그램을 이용하여, 실제 고속철도 자갈궤도에서 결함이 발생한 43개 지점에서 측정된 레일요철을 입력값으로 하여, 요철 깊이에 따른 충격 윤중과 레일 휨응력을 산정하였다. 궤도틀림을 감안하여 윤중 및 레일 휨응력의 한계값을 설정하고, 해석결과로부터 얻은 윤중 및 레일 휨응력 최대값과 결함 깊이 및 폭과의 상관관계를 분석함으로써 레일 표면 결함부에 대한 관리기준을 제시하였다. 분석 결과, 허용할 수 있는 요철 깊이는 충격 윤중에 의하여 발생할 수 있는 레일 두부의 소성 변형을 방지하기 위하여 관리되어야 하며, 엄격한 조건을 평가할 경우 그 값은 0.2mm 정도가 적당함을 알 수 있었다.

강도설계용 풍하중 평가를 위한 재현기간과 기본풍속지도의 제안 (Proposal of Return Period and Basic Wind Speed Map to Estimate Wind Loads for Strength Design in Korea)

  • 하영철
    • 대한건축학회논문집:구조계
    • /
    • 제34권2호
    • /
    • pp.29-40
    • /
    • 2018
  • Strength design wind loads for the wind resistance design of structures shall be evaluated by the product of wind loads calculated based on the basic wind speed with 100 years return period and the wind load factor 1.3 specified in the provisions of load combinations in Korean Building Code (KBC) 2016. It may be sure that the wind load factor 1.3 in KBC(2016) had not been determined by probabilistic method or empirical method using meteorological wind speed data in Korea. In this paper, wind load factors were evaluated by probabilistic method and empirical method. The annual maximum 10 minutes mean wind speed data at 69 meteorological stations during past 40 years from 1973 to 2012 were selected for this evaluation. From the comparison of the results of those two method, it can be found that the mean values of wind load factors calculated both probability based method and empirical based method were similar at all meteorological stations. When target level of reliability index is set up 2.5, the mean value of wind load factors for all regions should be presented about 1.35. When target level of reliability index is set up 3.0, wind load factor should be presented about 1.46. By using the relationship between importance factor(conversion factor for return period) and wind load factor, the return periods for strength design were estimated and expected wind speeds of all regions accounting for strength design were proposed. It can be found that return period to estimate wind loads for strength design should be 500 years and 800 years in according to target level of reliability index 2.5 and 3.0, respectively. The 500 years basic wind speed map for strength design was suggested and it can be used with a wind load factor 1.0.