• Title/Summary/Keyword: airflow

Search Result 767, Processing Time 0.026 seconds

Flow Analyses of Upper Airway Before and After Maxillomandibular Advancement Surgery for Obstructive Sleep Apnea Patient (폐쇄성 수면무호흡증 환자의 상하악 전진술 후 상기도 내 유동해석)

  • Kim, Hyoung-Ho;Suh, Sang-Ho;Choi, Jin-Young;Kim, Taeyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.5
    • /
    • pp.443-448
    • /
    • 2015
  • Obstructive sleep apnea (OSA) is a syndrome characterized by the repetitive episodic collapse of the upper airway. Maxillomandibular advancement surgery is one of the most effective surgical treatment methods in treating obstructive sleep apnea. The advancement of both maxill and mandible can enlarge the cross-sectional areas and volumes of the postero-superior airway. The purpose of this study is to analyze flow patterns in the upper airway before and after maxillomandibular advancement surgery. Here, we analyzed flow phenomena of inspiration and expiration to prevent obstructive sleep apnea patient from happening side effect. Modeling of the upper airway carried out from clinical CT scanned images. We used time-dependent values for boundary condition. CFD analyses were performed and evaluated section of minimum area (SMA), compared with patient inside upper airway before and after maxillomandibular advancement surgery in SMA, and negative pressure effects. The study showed the greatest enlargment of the section of minimum cross-sectional area. Moreover, the velocity and the negative airway pressure were decreased. According to the result of this study, the maxillomandibular advancement surgery stabilizes the airflow in the postero-superior airway of OSA patients.

Differences between Patients with TB-Destroyed Lung and Patients with COPD Admitted to the ICU

  • Seo, Young-Kyeong;Lee, Chae-Hun;Lee, Hyun-Kyung;Lee, Young-Min;Park, Hye-Kyeong;Choi, Sang-Bong;Kim, Hyun-Gook;Jang, Hang-Jea;Yum, Ho-Kee;Lee, Seung-Heon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.4
    • /
    • pp.323-329
    • /
    • 2011
  • Background: Although patients with tuberculous-destroyed lung (TDL) account for a significant proportion of those with chronic airflow obstruction, it is difficult to distinguish patients with airway obstruction due to TDL from patients with pure chronic obstructive pulmonary disease (COPD) on initial presentation with dyspnea. We investigated clinical features differing between (i) patients with TDL and airway obstruction and (ii) those with COPD admitted to the intensive care unit (ICU) due to dyspnea. Methods: We reviewed the medical records of patients with TDL who had a forced expiratory volume in 1 second (FEV1)/forced vital capacity (FVC) of <70% on a pulmonary function test (PFT; best value closest to admission) and patients with COPD without a history of pulmonary tuberculosis (TB) who were admitted to the ICU. Ultimately, 16 patients with TDL and 16 with COPD were compared, excluding patients with co-morbidities. Results: The mean ages of the patients with TDL and COPD were 63.7 and 71.2 years, respectively. Mean FVC% (50.4% vs. 71.9%; p<0.01) and mean FEV1% (39.1% vs. 58.4%; p<0.01) were significantly lower in the TDL group than in the COPD group. More frequent consolidation with TB (68.8% vs. 31.3%; p=0.03) and more tracheostomies (50.0% vs. 0.0%; p=0.02) were observed in the TDL than in the COPD group. Conclusion: Upon ICU admission, patients with TDL had TB pneumonia more frequently, more diminished PFT results, and more tracheostomies than patients with COPD.

Evaluation of characteristics for microbubble generation according to venturi nozzle specification (벤튜리 노즐 제원에 따른 마이크로버블 발생 특성 평가)

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6397-6402
    • /
    • 2015
  • This research was performed to review operating parameters, optimum condition and check characteristic of microbubble generation for using bubble size distribution according to venturi specification. Optimum operating condition have airflow rate 0.3 LPM, 3 bar(pressure tank) and connecting nozzle directly(without valve), it is advantageous to generate microbubble. In case of characteristic of microbubble generation according to venturi specification, effect that nozzle specification affects bubble size distribution is low impact. But considering performance aspects, when using nozzle that throat diameter 3-4 mm, $D_{50}$ are $54.98-61.19{\mu}m$(D3L15, D4L15), fraction of bubble less than $50{\mu}m$ are 0.326, 0.345. And it is superior to others. Besides, $D_{50}$ and fraction of bubble less than $50{\mu}m$ of throat length 20 mm are $49.40-54.98{\mu}m$, 0.447, respectively And nozzle that throat length 20 mm is relatively tendency to generate microbubble stably.

Development of Tunnel-Environment Monitoring System and Its Installation III -Measurement in Solan Tunnel- (터널 환경 측정 시스템 개발 및 측정 III -솔안터널 측정결과 분석-)

  • Park, Won-Hee;Cho, Youngmin;Kwon, Tae-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.637-644
    • /
    • 2016
  • This paper is a follow-up to previous papers entitled, "Development of Tunnel-Environment Monitoring System and Its Installation" I [1] and II [2]. The target tunnel of these studies is the Solan Tunnel, which is a loop-type, single-track, 16.7-km-long tunnel located in mountainous terrain and passing through the Baekdudaegan mountain range. It is an ordinary railway tunnel designed for both freight and passenger trains. We analyzed the environmental conditions of the tunnel using temperature and humidity data recorded over approximately one year. The data were recorded using the Tunnel Rough Environment Measuring System (TREMS), which measures environmental data in subway and high-speed train tunnels and is installed in three locations inside the tunnel. Previous studies analyzed environmental conditions inside tunnels located in or near a city, whereas the tunnel in this study is located in a mountainous area. The tunnel conditions were compared with those measured outside the tunnel for each month. Hourly changes during summer and winter periods were also analyzed, and the environmental conditions at different locations inside the tunnel were compared. The results are widely applicable in studies on the thermal environment and air quality of tunnels, as well as for computer analysis of tunnel airflow such as tunnel ventilation and fire simulations.

A Numerical Study on Smoke Behavior of Fishing Vessel Engine Room (어선 기관실의 연기 거동에 관한 수치해석 연구)

  • JANG, Ho-Sung;JI, Sang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The ventilation system of the engine room of a ship is generally installed to supply the combustion air necessary for the internal combustion engine and to remove the heat source generated in the engine room, and it must satisfy the international standard (ISO 8861) for the design conditions and calculation standards for the ventilation of the ship engine room. The response delay of the ventilation system including the fire detector is affected by the airflow formed inside the area and the location of the fire detector. In this study, to improve the initial fire detection response speed of a fire detector installed on a fishing vessel and to maintain the sensitivity of the installed detector, the smoke behavior was simulated using the air flow field inside the engine room, the amount of combustion air in the internal combustion engine, and the internal pressure of the engine room as variables. Analysis of the simulation results showed that reducing the flow rate in the air flow field and increasing the vortex by reducing the internal pressure of the engine room and installing a smoke curtain would accelerate the rise of the ceiling of the smoke component and improve the smoke detector response speed and ventilation system.

A Study on the Surface Wind Characteristics in Suwon City Using a GIS Data and a CFD Model (GIS 자료와 CFD 모델을 이용한 수원시 지표 바람 특성 연구)

  • Kang, Geon;Kim, Min-Ji;Kang, Jung-Eun;Yang, Minjune;Choi, Seok-Hwan;Kang, Eunha;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_2
    • /
    • pp.1837-1847
    • /
    • 2021
  • This study investigated wind corridors for the entire Suwon-city area using a geographic information system and a computational fluid dynamics model. We conducted numerical simulations for 16 inflow wind directions using the average wind speeds measured at the Suwon automated synoptic observation system (ASOS) for recent ten years. We analyzed the westerly (dominant wind direction) and easterly cases (not dominant but strong wind speed) in detail and investigated the characteristics of a wind speed distribution averaged using the frequencies of 16 wind directions as weighting factors. The characteristics of the wind corridors in Suwon city can be summarized as; (1) In the northern part of Suwon, complicated flows were formed by the high mountainous terrain, and strong (weak) winds and updrafts (downdrafts) were simulated on the windward (leeward) mountain slope. (2) On the leeward mountain slope, a wind corridor was formed along a valley, and relatively strong airflow flowed into the residential area. (3) The strong winds were simulated in a wide and flat area in the west and south part of Suwon city. (4) Due to the friction and flow blocking by buildings, wind speeds decreased, and airflows became complicated in the downtown area. (5) Wind corridors in residential areas were formed along wide roads and areas with few obstacles, such as rivers, lakes, and reservoirs.

Analysis of Causes of and Solutions to the Stack Effect by Vertical Zoning of High-rise Buildings (초고층 건축물 수직조닝별 연돌효과의 원인 및 해결 방안 분석)

  • Shin, Sang Wook;Ryu, Jong Woo;Jeong, Hee Woong;Kim, Dae Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.483-493
    • /
    • 2021
  • Urban overcrowding has created an explosive supply and demand for high-rise buildings. High-rise buildings are contributing to enhancing the image of the city by serving as focal points, but due to the stack effect, malfunction of elevator doors, difficulties in opening and closing the doors and windows of the outer wall, smoke and odors spreading to the upper floors, noise, energy loss, fire and pollutants have been causing various unexpected problems such as rapid spread of fire. This study classified high-rise buildings according to their vertical zoning, analyzed the causes of and solutions to the stack effect, and derived design and construction methods. Through the initial plan to block the outside air and securing airtightness through precise construction, we sought ways to secure the airtightness inside and outside the building by actively blocking the airflow from the lower floors. In addition, the facility solution can be a measure to reduce the specific phenomena caused by the stack effect, but it should only be applied to the minimum extent because the potential for secondary damage is high. This study emphasized the need for systematic stack effect management by suggesting design and construction measures for each vertical zoning of the causes and countermeasures of the stack effect. It is expected that this study will be helpful not only for design and construction, but also for building maintenance.

A Study on SOx Emission Characteristics in Coal Combustion (석탄 연소시 SOx 배출 특성에 관한 연구)

  • Kang, Youn Suk;Kim, Sung Su;Lee, Hyun Dong;Kim, Jae-Kwan;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.219-223
    • /
    • 2011
  • The characteristics of SOx emission were investigated using SM (India) coal and Berau, C&A (Austria) coal. Experiments were performed in two different ways. In the first type of experiment, the temperature in the furnace was increased and the, samples were combusted at the ignition temperature after filling the furnace with coal. The second experimental method was to add the coal to after maintaining a constant temperature. The results demonstrated that SOx emission from coal combustion depended upon the sulfur content. In the case of Berau coal and C&A coal, an enhancement of combustibility which was accomplished by increasing the combustion temperature, an increase in airflow and decrease in particle size of coals tended to increase $SO_2$ generation. Conversely, in the case of SM coal, the concentration of $SO_2$ tended to decrease, because the high contents of $Fe_2O_3$ in the ashes increased the oxidation power of coal itself, which oxidized $SO_2$ into $SO_3$. In the case of C&A coal, the $SO_2$ peak was only observed twice. This was thought to be caused by the thermal transfer rate from the surface to the interior of the coal.

Direct Switch from Tiotropium to Indacaterol/Glycopyrronium in Chronic Obstructive Pulmonary Disease Patients in Korea

  • Lee, Sang Haak;Rhee, Chin Kook;Yoo, Kwangha;Park, Jeong Woong;Yong, Suk Joong;Kim, Jusang;Lee, Taehoon;Lim, Seong Yong;Lee, Ji-Hyun;Park, Hye Yun;Moon, Minyoung;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.2
    • /
    • pp.96-104
    • /
    • 2021
  • Background: Many chronic obstructive pulmonary disease (COPD) patients receiving monotherapy continue to experience symptoms, exacerbations and poor quality of life. This study aimed to assess the efficacy and safety of direct switch from once-daily tiotropium (TIO) 18 ㎍ to indacaterol/glycopyrronium (IND/GLY) 110/50 ㎍ once daily in COPD patients in Korea. Methods: This was a randomized, open-label, parallel group, 12-week trial in mild-to-moderate COPD patients who received TIO 18 ㎍ once daily for ≥12 weeks prior to study initiation. Patients aged ≥40 years, with predicted post-bronchodilator forced expiratory volume in 1 second (FEV1) ≥50%, post-bronchodilator FEV1/forced vital capacity <0.7 and smoking history of ≥10 pack-years were included. Eligible patients were randomized in a 1:1 ratio to either IND/GLY or TIO. The primary objective was to demonstrate superiority of IND/GLY over TIO in pre-dose trough FEV1 at week 12. Secondary endpoints included transition dyspnea index (TDI) focal score, COPD assessment test (CAT) total score, and rescue medication use following the 12-week treatment, and safety assessment. Results: Of the 442 patients screened, 379 were randomized and 347 completed the study. IND/GLY demonstrated superiority in pre-dose trough FEV1 versus TIO at week 12 (least squares mean treatment difference [Δ], 50 mL; p=0.013). Also, numerical improvements were observed with IND/GLY in the TDI focal score (Δ, 0.31), CAT total score (Δ, -0.81), and rescue medication use (Δ, -0.09 puffs/day). Both treatments were well tolerated by patients. Conclusion: A direct switch from TIO to IND/GLY provided improvements in lung function and other patient-reported outcomes with an acceptable safety profile in patients with mild-to-moderate airflow limitation.

A Case Study of the Heavy Asian Dust Observed in May 2011 (2011년 5월 관측된 고농도 황사 사례 연구)

  • Ahn, Bo-Yeong;Lim, Byunghwan
    • Journal of the Korean earth science society
    • /
    • v.43 no.3
    • /
    • pp.386-404
    • /
    • 2022
  • From April 29 to 30, 2011, under the influence of Asian dust originated from Mongolia, a high concentration of Asian dust was observed nationwide for 4 days in Korea. This study investigated the causes and characteristics of and weather conditions associated with Asian dust at high concentrations at its source in Mongolia. For analysis, Asian dust weather data, Asian dust monitoring tower data, satellite data, backward trajectory data, observation data (PM10 and OPC data), and ECMWF reanalysis data were used. In the synoptic analysis, it was observed that the intervals of isobars were densely distributed in the central region of Mongolia and the pressure gradient force was strong. It could be inferenced that Asian dust occurred due to strong winds. The temperature was relatively high, above 10℃, just before the occurrence of Asian dust, and it decreased sharply at the onset of the dust. The relative humidity had a low value of less than approximately 40%. After the occurrence of Asian dust, it increased sharply to over 50% and then showed a tendency to decrease. In the aerosol index shown by the COMS satellite, a high concentration value of over 25 was detected in Inner Mongolia, and it was consistent with the observations made with naked eyes. In the 72-hour backward trajectory, the northwest airflow streamed into Korea, and on May 2, Heuksando showed the highest PM10 concentration of 1,025 ㎍ m-3(times the average). Especially, in kinematic vertical analysis, it was observed that low pressure on the ground was strengthened by cyclonic relative vorticity developed in the upper layer. Also, the vertical velocity development is considered to have played a major role in the occurrence of high concentration Asian dust.