• Title/Summary/Keyword: airflow

Search Result 773, Processing Time 0.039 seconds

The PIV measurements on the respiratory gas flow in human airway (호흡기 내 주기적 공기유동에 대한 PIV 계측)

  • Kim, Sung-Kyun;Chung, Seong-Kyu
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.93-98
    • /
    • 2005
  • The mean and RMS velocity field of the respiratory gas flow in tile human airway was studied experimentally by particle image velocimetry(PIV). Some researchers investigated the airflow for the mouth breathing case both experimentally and numerically. But it is very rare to investigate the airflow of nose breathing in a whole airway due to its geometric complexity. We established the procedure to create a transparent rectangular box containing a model of the human airway for PIV measurement by combination of the RP and the curing of clear silicone. We extend this to make a whole airway including nasal cavities, larynx, trachea, and 2 generations of bronchi. The CBC algorithm with window offset (64*64 to 32*32) is used for vector searching in PIV analysis. The phase averaged mean and RMS velocity distributions in Sagittal and coronal planes are obtained for 7 phases in a respiratory period. Some physiologic conjectures are obtained. The main stream went through the backside of larynx and trachea in inspiration and the frontal side in expiration. There exist vortical motions in inspiration, but no prominent one in expiration.

  • PDF

On the Regional Background Levels of $CH_4$ Observed Peninsula in Korea during 1990~1992 (한국의 태안반도에서 관측된 $CH_4$의 지역적 배경농도에 관한 연구 -1990~1992년 자료를 중심으로-)

  • 정용승;이근준
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.33-48
    • /
    • 1992
  • Since November 1990, the observations of methane (CH4) level have been carried out at Tae-ahn Peninsula (TAP) in Korea. Analysis on atmospheric data obtained in the period from November 1990 to August 1992 is carried out and the results are included in this study. We 임ole that CIL does not have a clear seasonal cycle with a minor maximum in August- september and with a minimum in June-July. The variations in monthly average level are much larger with 1765.01∼ 1857.21 pub (amplitude 92.20 ppb). The occurrence of a minimum in June-July is due to the inflow of the North Pacific air, an increase of OH radical and due to a decrease in CH4 emission from rice paddy. A maximum in August and September appears to result from an increase in organic materials in agriculture (rice paddy) and forests, inputs of local sources due to weak airflows, stagnation of the warm and moist air and from a decrease in OH radical.'rho present analysis indicates that according to CH4 data from Mongolia and from several sites in North Pacific TAP is influenced as much as 31 pub in average from the inputs of Chinese omission. When the atmospheric CH4 of TAP is compared with data observed at Korea National University of Education (KNU), the values of KNU are higher (127 ppb) than those of TAP. It is clear that air samples taken at KNU are influenced strongly by local sources in central Korea than those at TAP. According to analysis of trajectories and airflows, we find that there are 4 types in classification. Firstly, when an air flow is originated mainly in China values of CH4 gas are in medium ranges. Secondly, when an airflow is from both local (Korea) and China we find higher values. Thirdly, with an airflow from both local (Korea) and Japan origins medium values are recorded. Fourths)r, when an airflow of maritime origin arrives low values of atmospheric CH4 are observed at TAP.

  • PDF

Resistance to Air Flow through Fruits and Vegetables in Bulk (산물퇴적 청과물의 송풍저항 특성)

  • 윤홍선;조영길;박판규;박경규
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.333-342
    • /
    • 1995
  • The resistance to air flow through fruits and vegetables in bulk was an important consideration in the design of the pressure cooling system. The amount of resistance to air flow through produce in bulk normally depended upon air flow rate, stacking depth, porosity, stacking patterns and shape and site of product. But, there was not enough information relating the effects of those factors on air flow resistance. The objectives of this study were to investigate the effect of stacking depth, stacking patterns, porosity and airflow rate on airflow resistance and to develop a statistical model to predict static pressure drop across the produce bed as a function of air flow rate, stacking depth, bed porosity, and product size. Mandarins and tomatoes were used in the experiment. The airflow rate were in the range of 0.1~1.0 ㎥/s.$m^2$, the porosity were in the range of 0.25~0.45, the depth were in the range of 0.3~0.9m and the equivalent diameters were 5.3cm and 6.3cm for mandarins, and 6.5cm and 8.5cm for tomatoes. Three methods of stacking arrangement were used i.e. cubic, square staggered, and staggered stacking arrangement. The results were summarized as follows. 1. The pressure drops across produce bed increased in proportion to stacking depth and superficial air velocity and decreased in proportion to porosity. 2. The increasing rates of pressure drop according to stacking patterns with the increase of superficial air velocity were different one another. The staggered stacking arrangement produced the highest increasing rate and the cubic stacking arrangement produced the lowest increasing rate. But it could be assumed that the stacking patterns had not influenced greatly on pressure drops if it was of equal porosity. 3. The statistical models to predict the pressure drop across produce bed as a function of superficial air velocity, stacking depth, porosity, and product diameter were developed from these experiments.

  • PDF

A study on the program development for optimizing the supply and exhaust port opening ratio in road tunnels with transverse ventilation system (횡류식 도로터널의 급배기구 개도율 최적화 프로그램 개발 연구)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Min, Dea-Kee;Kim, Jong-Won;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.517-532
    • /
    • 2017
  • The transverse ventilation system, commonly applied to urban tunnel, is necessary to be distributed with airflow uniformly. In this study, we developed a program that can optimize the opening ratio of ports to ensure ventilation performance of design criteria through a uniform airflow distribution even though ventilation interval becomes longer. And program's prediction performance was verified by comparison with TUNVEN DUCT program. For comparison, Semi-transverse ventilation system was applied. Both programs predicted a similar port size and air flow distribution, and the variation range of the calculated values was 11.71% and 1.36%, respectively. This program is very useful for port optimization design of transverse and semi-transverse ventilation system, because it is possible to analyze various tunnel lengths and supply/exhaust port installation conditions.

An Experimental Study of 30CMM Solar Transpired Collector and Cyclone(STCC) System on Indoor Air Dust Removal Performance (30CMM급 태양기공 전기집진 설비의 실내분진 정화 능력에 관한 실험연구)

  • Noh, Ji-Hee;Park, Sang-Hyun;Kang, Eun-Chul;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.37-45
    • /
    • 2005
  • Higher requirement of advanced building design code and the development of construction technique have resulted in more thermal and air tight buildings. This has caused the sick building syndrome in a indoor air quality has been relatively getting worse. A new concept with a solar fresh air heating and electrostatic precipitator or called as STCC(Solar Transpired Collector and Cyclone) has been proposed to solve this IAQ issue. This paper describes the assessment study of STCC system under different outdoor airflow rates. The experiment was carried out under real condition with 30CMM STCC system test facility. Incense smoke was used to study the particle concentration decay trends under outdoor airflow rates 0CMM, 10CMM, 20CMM, 30CMM, with applied voltages of 5kV and 15kV for collecting and discharging electrodes of an Electrostatic Precipitator. Result shows that the particle decay increases by increasing the outdoor airflow rates. The collection efficiency, dust cleaning effectiveness(P) and application area calculation result comparisons have also been studied. This factors could be used to estimate how a dust of indoor air quality(IAQ) and removed for a building space with a STCC system.

Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation (CFD 검증을 위한 풍동 및 PIV를 이용한 자연환기식 온실 내부 공기유동 분석)

  • Ha, Jung-Soo;Lee, In-Bok;Kwon, Kyeong-Seok;Ha, Tae-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.391-400
    • /
    • 2014
  • The number of large scale greenhouses has recently been increasing to cope with mass consumption of agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from $1m{\cdot}s^{-1}$ to $1.5m{\cdot}s^{-1}$, air velocities inside the greenhouse which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.

The Airflow Obstruction and Subjective Health Status Among Stable Chronic Obstructive Pulmonary Disease Patients Residing in the Community (안정된 만성폐쇄성폐질환 환자의 기류제한 정도와 주관적 건강상태)

  • Song, Hee-Young
    • Journal of Korean Biological Nursing Science
    • /
    • v.19 no.1
    • /
    • pp.38-47
    • /
    • 2017
  • Purpose: This study was undertaken to examine the relationship between airflow obstruction and subjective health status reported by stable patients with chronic obstructive pulmonary disease (COPD) residing in the community. Methods: A cross-sectional descriptive study was conducted with 78 stable COPD patients aged 69.7 years old on average and selected by a convenient sampling from an outpatient department of pulmonology in tertiary hospitals. They completed a constructed questionnaire including general characteristics, smoking history, dyspnea by modified medical research council (mMRC) scale, and health status by COPD assessment test (CAT). Anthropometric measurements were performed for body mass index (BMI) and pulse oxymetry for $O_2$ saturation (Sat $O_2$). Medical records were reviewed to obtain disease-related characteristics including duration of the disease, cardiovascular comorbidity, and forced expiratory volume in 1 second ($FEV_1$). Data were analyzed using PASW statistics 20.0. Results: Mean $FEV_1%$ and CAT scores were 55.11% and 17.73, respectively. Those in the lower stage of mMRC showed significantly higher $FEV_1$ and lower CAT. $FEV_1$ and CAT showed significant negative correlations; age and BMI with $FEV_1$, and Sat $O_2$ with CAT. Conclusion: The findings suggest that the less airway obstruction was, the better health status was, and provide the support for using subjective measures in clinical practices for COPD patients.

Efficient Inverter Type Compressor System using the Distribution of the Air Flow Rate (공기 변화량 분포를 이용한 효율적인 인버터타입 압축기 시스템)

  • Shim, JaeRyong;Kim, Yong-Chul;Noh, Young-Bin;Jung, Hoe-kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2396-2402
    • /
    • 2015
  • Air compressor, as an essential equipment used in the factory and plant operations, accounts for around 30% of the total electricity consumption in U.S.A, thereby being proposed advanced technologies to reduce electricity consumption. When the fluctuation of the compressed airflow rate is small, the system stability is increased followed by the reduction of the electricity consumption which results in the efficient design of the energy system. In the statistical analysis, the normal distribution, log normal distribution, gamma distribution or the like are generally used to identify system characteristics. However a single distribution may not fit well the data with long tail, representing sudden air flow rate especially in extremes. In this paper, authors decouple the compressed airflow rate into two parts to present a mixture of distribution function and suggest a method to reduce the electricity consumption. This reduction stems from the fact that a general pareto distribution estimates more accurate quantile value than a gaussian distribution when an airflow rate exceeds over a large number.

Effect of Hydraulic Pressure on Bubble Dissolution Rate of Ejector Type Microbubble Generator (수압이 자흡식 마이크로버블 발생장치의 산소 용해율에 미치는 영향)

  • Kim, Hyun-Sik;Lim, Ji-Young;Park, Soo-Young;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.2
    • /
    • pp.27-31
    • /
    • 2017
  • This study was performed to estimate bubble dissolution rate by change of hydraulic pressure according to increase of water depth. Experimental results showed that airflow rate was decreased by increase of hydraulic pressure. Because the force which acts on outlet of nozzle was increased by increase of hydraulic pressure. Mass-transfer coefficient decreased with decreasing airflow rate and increasing effective volume due to increase of hydraulic pressure as water depth increased. On the contrary, as the water depth increased, the bubble dissolution rate was increased because longer residence time of microbubble which was generated by ejector type microbubble generator. However it was thought that if water depth for capacity of ejector type microbubble generator is excessively increasing, bubble dissolution rate would be reduced due to low airflow rate and mass-transfer coefficient. Therefore, it is importance to consider the water depth when operating ejector type microbubble generator.

A Study on Energy Saving Performance by Night Purge Cooling with Pressurized Under Floor Air Distribution System (가압식 바닥공조 시스템과 야간 외기냉방의 병용에 따른 에너지저감 성능에 관한 연구)

  • Yoon, Seong-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • It has been reported about the energy saving performance of UFAD(under floor air distribution) system and NPC(night purge cooling) system respectively which are applied for commercial buildings. However, when two systems are used at the same time, the effect of heat transfer from floor plenum to slab may vary depending on the operating conditions of NPC. In this study, cooling energy demands were analyzed for building models with UFAD and NPC by using TRNSYS 17 program. UFAD was applied as a cooling system of the base building model, and the cooling energy demands were compared for 64 cases in which the operating time, supply airflow rate, and outdoor air temperature(To) of NPC. As a result, it was confirmed that the cooling energy demands were reduced to 30 ~ 80% level compared to UFAD alone, and in particular, the energy demand was reduced in proportion to the supply airflow rate or the operating time while To was 16 ~ 20℃. However, when To was 22℃, the increase in the supply airflow rate or the operating time results in a disadvantage in terms of cooling energy demands. In addition, the cooling energy demands for UFAD+NPC model were analyzed by applying weather data from three regions with different average outdoor air temperatures. As a result, the cooling energy demand of operating NPC only when To was below 20℃ was reduced by 27% compared to that of operating NPC continuously for 8 hours.