• Title/Summary/Keyword: airborne dust

Search Result 137, Processing Time 0.025 seconds

Estimation of Factors Influencing Airborne Fiber Concentrations through an Observation Survey of Asbestos-containing Materials in Buildings (석면함유 건축물의 관찰조사를 통한 실내공기 중 섬유 농도 변화 요인 추정)

  • Lee, Seungchul;Kim, Boowook;Yi, Gwang Yong;Shin, Yong Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.174-183
    • /
    • 2015
  • Objectives: The objective of this study is the estimation of factors influencing airborne fiber concentrations by means of an observation survey of asbestos-containing materials in buildings. Methods: Forty-five samples were collected from four commercial buildings by NIOSH Method 7400 and classified according to current condition, potential activity, construction year, and operations and maintenance(O&M). Results: Airborne fiber concentrations by current condition(classified as good, fair and poor) were significantly different(p<0.05). Concentrations by potential activity were significantly different among groups(p<0.05), and those from the low activity group were higher than those from the middle activity group. Based on construction year, airborne fiber concentrations from the decade of the 1990's were higher than those from the 1960's. When O&M status was considered, airborne fiber concentrations from 1960's buildings were lower than those buildings not operated and maintained(p<0.01), because dust generation was influenced by O&M status. It was found that airborne fiber concentrations were related to current condition and potential activity via regression analysis, but the coefficient of determination was low. Also, correlation analysis showed that the higher the potential activity, the more current condition is worsened, but the relationship was not significant(r=-0.455, p>0.05). Conclusions: Airborne fiber concentrations in asbestos-containing buildings had weak relationships with current condition and potential activity.

Fungal Distribution of the Janggyeong Panjeon, the Depositories for the Tripitaka Koreana Woodblocks in the Haeinsa Temple

  • Hong, Jin Young;Kim, Young Hee;Lee, Jeong Min;Kim, Soo Ji;Park, Ji Hee
    • Journal of Conservation Science
    • /
    • v.38 no.1
    • /
    • pp.64-71
    • /
    • 2022
  • Many investigations have been conducted on the biological damage and environmental conditions necessary to preserve the Janggyeong Panjeon and Daejanggyeongpan (woodblocks). We performed a survey on the concentration and diversity of airborne fungi in the Janggyeong Panjeon and compared them with the results of a survey from 2012. The temperature of the Beopbojeon building was slightly lower, while the relative humidity was higher than those found at the Sudarajang building. The concentration of airborne fungi in the Beopbojeon was 1.44-fold that of the Sudarajang. It was confirmed that the concentration and diversity of airborne fungi in the Janggyeong Panjeon differed depending on the sampling site. In total, 23 fungal genera were identified from the air samples, and 11 fungal and 1 bacterial genera were identified from the surface of the woodblocks. Among these, only five types of fungi were commonly distributed in the indoor air and surface of the Daejanggyeongpan; however, 58.3% of the fungi identified on the surface of the woodblocks were not observed in the in the air samples. The surface-dwelling fungi may accumulate dust to form microbial communities over time.

Size Distribution and Source Identification of Airborne Particulate Matter and Metallic Elements in a Typical Industrial City

  • Ny, Mai Tra;Lee, Byeong-Kyu
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.9-19
    • /
    • 2010
  • The size distribution of airborne particulate matter (PM) and the concentrations of associated metallic elements were investigated in a busy urban region of a typical Korean industrial city. The PM concentrations measured during the spring, except for those in the size range of 1.1 to 2.1 ${\mu}m$, were slightly higher than the PM concentrations in the summer. Coarse particles contributed greatly to the variation in PM concentrations in the spring, while fine and submicron particles contributed largely to the variation in PM concentrations in the summer. The difference in size modes of the PM concentrations between spring and summer may be explained by the Asian dust effect and its accompanying wind direction and speed. Extremely high enrichment factors (EFs) values (6,971 to 60,966) for all of the size distributions in PM were identified for cadmium (Cd). High EFs values (12 to 907) were also identified for other heavy metals including Cr, Cu, Ni, Pb, Zn and Mn. Low EF values (0.29 to 8.61) were identified for Ca, K, Mg and Na. These results support the common hypothesis that most heavy metals in ambient PM have anthropogenic sources and most light metals have crustal sources. The results of principal components analyses and cluster analyses for heavy metals indicate that the principal sources of PM and metals were emissions from non-ferrous metal smelters, oil combustion, incinerators, vehicular traffic and road dust.

Investigation of Job Satisfaction and Hazardous Factors of Aircraft Cleaning Worker (항공기 청소 노동자의 작업 만족도 및 유해인자 조사)

  • Choi, Yeonhak;Kim, Ki-Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.174-184
    • /
    • 2020
  • Objectives: The purpose of this study was to improve the working environment by identifying the work satisfaction of the cleaning workers of the aircraft and measuring and assessing the harmful factors of the cleaning process. Methods: We asked 23 cleaning companies for questionnaires and got 100 answers from 5 companies. The A-E Airline health manager has been contacted to establish a site survey schedule. The in-flight and lounge were measured using direct reading equipment. The harmful factor to be measured are noise, dust, temperature, volatile organic compound, total airborne bacteria, and total airborne bacteria. Results: Uncomfortable positions when replacing blanket, cleaning the table, and cleaning the floor have been identified as factor that reduce work satisfaction. Noise when replacing newspapers and cleaning toilets has been identified as a factor that lowers work satisfaction. Temperature and humidity were found to reduce work satisfaction during in-flight disinfection. Measurements of aircraft cabin and lounge with direct read equipment have shown that none of the items exceed the exposure criteria. Conclusions: As a result of measuring direct-reading equipment, no items exceeded the exposure criteria for each harmful factor. A clear survey of the working environment is required based on the results, and additional research is needed using personal sample measurement.

Study on the Characteristics of Air quality in the Classroom of Elementary School and Its Control Methods (초등학교 교실공기질의 특징과 제어방안에 관한 연구)

  • Jeong, Ji-Won;Lee, Hee-Kwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.311-322
    • /
    • 2010
  • The common life with modern urban residence, spending more than 80~90% of daily life in indoor environment, makes the importance of indoor air quality (IAQ) even higher. Many efforts have made to improve indoor air quality (IAQ), which requires those systematic approaches for field practice. A recent study reported that no general approach cannot be made for IAQ improvement due to the great deal of variety in different indoor environments. Those indoor spaces included in Korean IAQ regulation were classified based on their characteristics and the IAQ guideline was suggested for each group of indoor spaces. Apart from those indoor spaces, the classroom in elementary school has different characteristics. By introducing the systematic approaches, the elementary classroom was surveyed and analyzed to understand its characteristics in due IAQ consideration. Based on the characteristics, there are several IAQ control measures suggested, including ventilation operation, dust mat installation, and white board. $CO_2$ and airborne dust were monitored and analyzed in order to evaluate the effectiveness of each control measure to IAQ. It was found that the general level of $CO_2$ concentration was managed under the IAQ guideline by applying the ventilator operation. The ventilation was also effective to the fugitive airborne particulate in elementary classroom environment.

Evaluation of Indoor Mold Exposure Level in dwelling Using DNA-Based Mold Assessment Method (DNA 기반 곰팡이 평가기법을 활용한 주택의 실내 곰팡이 노출수준 평가)

  • Hwang, Eun-Seol;Seo, Sung Chul;Lee, Ju-Yeong;Ryu, Jung-min;Kwon, Myung-Hee;Chung, Hyen-Mi;Cho, Yong-Min;Lee, Jung-Sub
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.4
    • /
    • pp.382-392
    • /
    • 2018
  • Objective: Allergic diseases such as asthma due to fungal exposure in houses have increased, and proper management is urgent. Mold can grow in the air, floor, walls, and other areas according to environmental conditions, and there are many limitations to the conventional methodology for examining fungal exposure. For this reason, the degree of fungal contamination is being evaluated by ERMI (Environmental Relative Moldiness Index), a quantitative analysis method proposed by the EPA. In this study, we compared ERMI values between water-damaged dwellings and non-damaged ones to evaluate the effectiveness of Korean ERMI values. We also explored the association of ERMI values with the level of airborne mold and characteristics of dwellings. Methods: Floor dust was collected after installing a Dustream collector on the suction port of a vacuum cleaner. The collected samples were filtered to remove only 5 mg of dust, and DNA was extracted using the FastDNA SPIN KIT protocol. Results: The ERMI values were found to be 19.6 (-6.9-58.8) for flooded houses, 7.5 (-29.2-48.3) for leaks/condensation, and 0.8 (-29.2-37.9) for non-damaged dwellings. The airborne concentration of mold for flooded, leakage or condensed, and non-damaged houses were $684CFU/m^3$, $566CFU/m^3$, and $378CFU/m^3$, respectively. The correlation between ERMI values and the levels of airborne mold was low (R = 0.038), but a weakly significant association of the ERMI values with the concentration of particulate matter ($PM_{10}$) was observed as well(R=0.231,P<0.05). Conclusions: Our findings show that the reference value using ERMI can be used to distinguish water-damaged and non-damaged dwellings. It is believed that ERMI values could be a promising tool for assessing long-term fungal exposure in dwellings.

Composition and Size Variation of Airborne Fungal Spores in the Asian Dust Events (2000 ~ 2001)

  • Yeo, Hwan-Goo;Kim, Jong-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.4
    • /
    • pp.294-299
    • /
    • 2002
  • PM (Particulate Matter) samples contained fungal spores were collected in the ambient air of Seosan, west Korea, in springtime of 2000 and 2001. PM concentrations were $199.8\mu{g}\;m^{-3}$ in the 1st Asian Dust Storm period (March, 23 ~ 24) and $249.4\mu{g}\;m^{-3}$ in the 2nd period (April, 7~9), 2000. Compared with the concentrations in 2000, relatively low PM concentration ($157.3\mu{g}\;m^{-3}$ ) was measured in the Asian Dust Storm period (April, 24 ~ 20) of 2001. Although there were somewhat differences for the total PM concentrations among the three periods, majorities of the PM were composed of coarse particles sized about 5 ~ 6 $\mu{m}$ over the periods of the two years. Diverse molds grown from fungal aerosols were observed in the PM samples and identified at the genus level. All the genera, Fusarium, Aspergillus, Penicillium, Basipetospora, Epicoccum and Monotospora are hyphomycetes in the division Fungi imperfecti (Deuteromycota). Especially, morphologically more diversified mycelia of hyphomycetes were grown on the fine PM sample (1.1 ~ 2.1 $\mu{m}$) than coarse PM samples in the periods of 2000. Furthermore, some molds were grown on even the background PM sample less than 0.43 $\mu{m}$ in the period of 2001. It was thought that some kinds of ultra fine sized fungal spores were transported by the Asian Dust Storm and suspended in the ambient air of study area during the events.

Pollution Level of Heavy Metals of Asian Dust in Daejeon Area, 2008 (2008년 대전지역에서 발생한 황사의 중금속 오염도)

  • Lee, Pyeong-Koo;Bae, Beob-Geun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.1
    • /
    • pp.8-25
    • /
    • 2014
  • The aims of this study were to determine concentrations of selected metals in Asian and non-Asian dust collected in Daejeon, Korea between February 2008 and December 2008 and to estimate the pollution level. The geochemical analyses of Asian dust (AD) and Non Asian dust (NAD) show that the mean concentrations of As, Cd, Cu, Pb, Zn, Zr, Sb, Mo and S reached levels up to 16, 209, 31, 43, 81, 28, 31, 122 and 302 times higher, respectively, than those in uncontaminated Chinese desert soils. These results indicate that both AD and NAD serve as an atmospheric repository for trace and heavymetal accumulation. The the enrichment factor (EF) and pollution index (PI) show that AD and NAD were severely contaminated by S, Mo, Zr, Cd, Pb, Zn, Sb, Cu, and As. All indices for these metals showed either strong or notably high level of pollution relative to Chinese desert soil, principally due to the severe atmospheric pollution derived from anthropogenic activities in heavily industrial Chinese cities. Therefore, Mo, Cd, Zr, As, Cu, Sb, Pb, and Zn are the ones most strongly affected by anthropogenic inputs such as airborne pollutants.

Exposure Assessment of Phthalates from House Dust and Organic Films in the Indoor Environment (실내환경 중 집먼지 및 유기필름에서 기인한 프탈레이트 노출평가)

  • Joen, Jeong-In;Lee, Hye-Won;Lee, Seung-Hyun;Lee, Jeong-Il;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.2
    • /
    • pp.75-85
    • /
    • 2022
  • Background: Various types of semi-volatile organic compounds (SVOCs) exist in the public's living environment. They occur in different forms in terms of their physical and chemical properties and partition coefficients. As a consequence, indoor exposure to SVOCs occurs via various routes, including inhalation of air and airborne particles, skin contact, and dust intake. Objectives: To propose a method for assessing human exposure to the SVOCs occurring in the air of an indoor environment, the concentrations of SVOCs in house dust and organic films measured in a real residential environment were estimated in terms of gas-phase concentration using the partition coefficient. Assessment of inhalation exposure to SVOCs was performed using this method. Methods: Phthalates were collected from samples of house dust and organic films from 110 households in a real residential environment. To perform an exposures assessment of the phthalates present in organic films, gas-phase concentration was calculated using the partition coefficient. The airborne gas-phase concentrations of phthalates from the house dust and organic films were estimated and exposure assessment was performed based on the assumption of inhalation exposure from air. Results: As a result of the exposure assessment for gas-phase phthalates from house dust and organic films, preschool children showed the highest level of inhalation of phthalates, followed by school children, adults, and adolescents. Conclusions: This study includes the limitation of not considering different SVOCs exposure pathways in the health impact assessment, including those of phthalates in the indoor living environment. However, this study has the significance of performing exposure assessment based on exposure to SVOCs present in indoor air that originated from organic films in the indoor residential environment. Therefore, the results of this study should be useful as basic data for exposure and health risk assessments of SVOCs associated with organic films in the indoor environment.