• 제목/요약/키워드: air-inflated space thickness

검색결과 3건 처리시간 0.018초

공기막 이중필름의 공기막 두께와 주입공기 온도에 따른 관류전열량 변화 특성 (Characteristics of Heat Transmission Variation by Air Space Thickness and Injected Air Temperature in Air-Inflated Double Layers Film)

  • 김형권;전종길;백이;이상호;윤남규;유주열
    • 한국농공학회논문집
    • /
    • 제55권6호
    • /
    • pp.121-125
    • /
    • 2013
  • This study was carried out to provide a valuable reference which could reduce heating loss of air-inflated double PO film. Therefore, this study was aimed to choose the best air space thickness and injected air temperature. The characteristics of heat transmission variation at experimental materials were measured and analysed in the laboratory. The experiment was conducted of two layers of PO film, each 0.15 mm tick, sandwiching 110, 175, 225 mm of inflated air with 1 m sides. Environmental control lab was constantly controlled with $-10^{\circ}C$ and experiment chamber was constantly changed with 0, 5, 10, $15^{\circ}C$. The analysis of heat transfer showed that heat transmission does not have a direct correlation with Air Space thickness and injected air temperature. But when inside and outside temperature difference of chamber was great, supply of outside air to Air Space had an advantage at reduction of heating load. It was required to examine accurate analysis at a real greenhouse.

공기주입 이중피복 플라스틱온실의 공기주입장치 설계를 위한 기초실험 (Fundamental Experiments for Design of Air Inflating Apparatus of Air-Inflated Double-Layer Plastic Greenhouse)

  • 이현우;남효석;심상연;남상운;김영식
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.19-24
    • /
    • 2009
  • This study was conducted to provide fundamental data for design of air inflating apparatus of air-inflated double-layer plastic greenhouse. The variation of static pressure in air tube for different fans and filters, filtering performance for various kinds of filters and destruction phase of experimental greenhouse collapsed by excessive static pressure in air space were analyzed. The general type of forward centrifugal fan was recommended for inflating air space in air-inflated double-layer plastic greenhouse. The experimental greenhouse was collapsed down by excessive static pressure just like fallen by heavy snow load acting on it. The static pressure in air tube without filter decreased linearly as the number of outlet openings increased. But the pressure in air tube with filter declined quadratically, the decremental ratio diminished by the increase of outlet openings. The higher filtering efficiency and the greater decrements of static pressure in air tube, the larger capacity fan was required for maintaining proper static pressure in air space. Because the porosities of filter were blocked by dust as time goes by, the static pressure in air tube with filter decreased. The higher filtering efficiency, the less decremental ratio of static pressure in air tube as time passes by. Considering the filtering efficiency, decrement of static pressure and thickness of filter, the 5mm thickness filter of 75% efficiency was recommended for air inflating filter of air-inflated double-layer plastic greenhouse.

열저항식을 이용한 공기막 이중필름의 관류전열량 특성 분석 (Analysis of Heat Transmission Characteristics through Air-Inflated Double Layer Film by Using Thermal Resistance Equation)

  • 김형권;전종길;백이;이상호;윤남규;유주열
    • 생물환경조절학회지
    • /
    • 제22권4호
    • /
    • pp.316-321
    • /
    • 2013
  • 본 연구는 온실의 관류전열량을 분석하고 예측하는데 필요한 기초자료 제공을 위하여, 공기막 이중 PO필름의 열저항식을 모델링하였고, 전도, 복사, 대류에 의한 열저항 특성을 규명하였다. 또한 열저항식의 타당성 검증을 위해 열저항식에 의한 관류전열량의 계산값과 실험값을 비교 분석하였다. 공기막 이중 PO필름의 열저항식은 PO필름, 공기막, PO필름의 직렬 열저항식으로 구성되며, 공기막은 복사와 대류에 의한 병렬 열저항식으로 구성된다. 고온부 $T_1$의 평균온도는 276.1K, 저온부 $T_2$의 평균온도는 266.8K로 나타났으며, 다른 조건들이 동일할 경우 챔버 내부온도가 높을수록 $T_1$$T_2$의 평균온도와 온도차가 증가하는 것을 확인할 수 있었다. 전도열저항은 $0.00091K{\cdot}W^{-1}$로 전체 열저항의 1% 미만으로 매우 미미한 수준이고, 공기막의 열저항이 $0.18K{\cdot}W^{-1}$로 전체 열저항의 99% 이상을 차지하는 것으로 나타났다. 공기막의 경우 대류열 저항이 복사열저항에 비해 1.33~2.08배 정도 크게 나타났으며, 복사열저항은 평균온도의 3제곱에 반비례하고 대류열저항은 온도차가 4.7, 5.3, 5.5, 5.7, 12.3, 13.2, 13.3, 13.5, 13.8 및 14.0K로 증가할 때 각각 0.78, 0.75, 0.74, 0.73, 0.57, 0.56, 0.56, 0.56, 0.55 및 $0.55K{\cdot}W^{-1}$로 감소하였다. 관류전열량의 계산값과 실험값의 차이는 실험조건별로 0.6~17.2W의 범위로 평균 6.9W였으며, 실험값은 계산값의 79.8~97.7% 범위로 평균 87.3% 수준으로 나타났다. 전체적인 계산값과 실험값의 관류전열량 경향성은 잘 일치하고 있으며, 공기막 이중필름의 열저항은 공기막 두께 및 주입공기의 종류와는 직접적인 상관관계를 보이지 않았다.