• 제목/요약/키워드: air-flow system

검색결과 2,498건 처리시간 0.033초

단거리 대공방어유도탄체계와 이기종 함정 전투체계간 최적의 연동 설계 기법 (Optimal Interface Design between Short-Range Air Defense Missile System and Dissimilar Combat Systems)

  • 박현우
    • 한국군사과학기술학회지
    • /
    • 제18권3호
    • /
    • pp.260-266
    • /
    • 2015
  • The warship is run based on the combat system which shares tactical information collected by target detection systems and navigation devices across a network, and conducts the command and control of weapons from target detection to kill assessment. The short-range air defense missile system defends a warship from anti-ship missiles, aircraft, helicopter and other threats in order to contribute to the survival of a warship and the success of missions. The short-range air defense missile system is applied to a various combat systems. In this paper, we have proposed the interface design between the short-range air defense missile and dissimilar combat systems. To employ the short-range air defense missile at dissimilar combat systems, each system is driven by independent processor, and the tasks which are performed by each system are assigned. The information created by them is exchanged through the interface, and the flow of messages is designed.

급기가압 제연설비의 내부 유동특성에 대한 수치해석 (Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System)

  • 고권현
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.52-58
    • /
    • 2017
  • 본 연구에서는 급기가압에 따른 건축물 내부의 공기유동에 대한 수치해석을 수행하고 거실, 부속실 및 계단실 간의 차압분포 및 유동 특성을 분석하였다. 유동 해석은 유효누설면적을 측정하기 위해 제작된 누기율 시험설비에 대하여 수행하였으며, 급기가압에 따른 각 실의 압력 및 유속분포 등을 분석하였다. 본 해석에서 공기의 누설은 유효누설면적을 갖는 얇은 틈새를 방화문과 창문에 위치시키는 방법으로 모사하였다. 이러한 방법을 이용한 해석은 계단실과 부속실 간의 차압에 대한 기존 실험의 결과를 적절히 예측하였다. 해석 결과를 통해 국부적인 누설이 급기가압 제연 설비의 전체적인 유동 패턴 및 압력 분포에 큰 영향을 미치지 않음을 확인하였다. 거실-부속실 문 단면에서의 평균속도가 방연풍속에 대한 국가화재안전기준을 만족하였으나 문의 상부와 같은 국부적인 위치에서 부속실로의 유출이 발생할 수 있음을 확인하였다.

Tandem 시스템의 NOx 저감 효과에 관한 연구 (A Study on the Effects of NOx Reduction for the Tandem System)

  • 남정길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.645-653
    • /
    • 2005
  • The effects of a WI(Water Injection) at the intake Pipe and an urea injection at the exhaust pipe for a 4-cylinder DI(Direct Injection) diesel engine were investigated experimentally The water quantity was controlled by temperature of intake manifold and MAF(Manifold Air Flow). In addition, the urea quantify was controlled by NOx quantify and MAF. Effects of WI system, urea-SCR system and tandem system were investigated for with and without EGR(Exhaust Gas Recirculation). As the results. the SUF(Stoichiometric Urea Flow) and NOx map were obtained. In addition, NOx results can be visualized with engine speed and engine load. It was concluded. therefore, that the NOx reduction effects of the tandem system without the EGR were more than those with the EGR base engine.

핀-튜브형 액체건조제 제습기의 높이에 따른 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristic with Height of a Fin-Tube Liquid Desiccant Dehumidifier)

  • 이수동;박문수;정진은;이진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.25-30
    • /
    • 2003
  • Several desiccant cooling systems have been developed in terms of cost and performance. In this study a fin-tube exchanger has been used for liquid desiccant dehumidification system. This dehumidifier has been designed to study the absorption characteristic of the aqueous triethylene glycol(TEG) solution which has the flow range from 20 to 50 LPM. The dehumidifier performance characteristic of working factor variables such as inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity has been analyzed. The result of this experiment can provide useful data for hybrid air conditioning system.

  • PDF

고온 세라믹 폐열회수장치의 안전성 향상 연구 (A Study on the Safety Improvement of the High Temperature Ceramic Heat Recovery System)

  • 박용환;강영구;김홍
    • 한국안전학회지
    • /
    • 제11권4호
    • /
    • pp.107-114
    • /
    • 1996
  • A study to Improve the safety of the ceramic heat exchanger In the high temperature heat recovery system was performed in terms of air flow passes. The numerical and finite element analyses on the heat transfer and thermal stresses in the ceramic core related with air passes were carried out. The results showed that the stresses in the ceramic core induced by the thermal expansion are large enough to cause failure of the brittle ceramic core. The imployment of triple-pass air flow for the same ceramic core could increase the efficiency and effectively release approximately 20% of the maximum thermal stressess, thus improving the safety of the ceramic heat exchanger. The use of triple-pass, however, is limited by the amount of air flow due to the increase of pressure drop.

  • PDF

유동 양식 선도를 이용한 에어컨 실내기의 냉매 소음 저감 분석 (Experimental Study of the Refrigerant Induced Noise for Air Conditioner Using Flow Pattern Map)

  • 한형석;모진용;정의봉
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.957-963
    • /
    • 2008
  • The refrigerant-induced noise of the air conditioner is one of the irregular noises which occurs at the indoor unit. Because the air-conditioner makers are always trying to reduce the sound pressure level radiated from indoor unit, reducing the refrigerant-induced noise at low cooling mode is very important problem. But it is very difficult to estimate whether the refrigerant-induced noise occurs or not before it becomes problem. In this paper, a method to predict the refrigerant-induced noise is suggested using flow pattern map. It is estimated that the irregular noise from the refrigerant comes from the slug flow in a pipe.

  • PDF

과열기 관군에서의 증기유량 균일 배분 연구 (A Study on the Uniform Distribution of Steam Flow in the Superheater Tube System)

  • 박호영;김성철
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.416-426
    • /
    • 2008
  • The boiler tube failure often experienced in the superheater of a utility boiler can seriously affect the economic and safe operation of the power plant. It has been known that this failure is mainly caused by the thermal load deviation in the superheater tube system, and deeply intensified by the non-uniform distribution of steam flow rates. The nonuniform steam flow is distinctively prominent at low power load rather than at full power load. In this paper, we analyze the steam flow distribution in the superheater tube system by using one dimensional flow network model. At 30% power load, the deviation of steam flow rate is predicted to be within 0.8% of the averaged flow rate. This deviation can be reduced to 0.1% and 0.07% by assuming two cases, that is, the removal of 13th tube at each tube rows and the installation of intermediate header, respectively. The assumed two cases would be effective for the uniform steam flow distribution across 85 superheater tube rows.

수막하우스의 유량 및 수온에 따른 열전달 특성 분석 (Analysis of Heat Transfer Characteristics in Response to Water Flow Rate and Temperature in Greenhouses with Water Curtain System)

  • 김형권;김승희;권진경
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.270-276
    • /
    • 2016
  • This study analysed overall heat transfer coefficient, heat transmission, and rate of indoor air heating provided by water curtain in order to determine the heat transfer characteristic of double-layered greenhouse equipped with a water curtain system. The air temperatures between the inner and outer layers were determined by the water flow rate and inlet water temperature. Higher water flow rate and inlet water temperature resulted in the increased overall heat transfer coefficient between indoor greenhouse air and water curtain. However, it was found that with higher levels of water flow rate and inlet water temperature, indoor overall heat transfer coefficient was converged about $10W{\cdot}m^{-2}{\cdot}^oC^{-1}$. The low correlation of overall heat transfer coefficient between water curtain and air within double layers was likely because the combination of greenhouse shape, wind speed and outdoor air temperature as well as water curtain affected the heat transfer characteristics. As water flow rate and inlet water temperature increased, the heat transferred into the greenhouse by water curtain also tend to rise. However it was demonstrated that the rate of heat transmission from water curtain into greenhouse with water curtain system using underground water was accounted for 22% to 28% for total heat lost by water curtain. The results of this study which quantify heat transfer coefficient and net heat transfer from water curtain may be a good reference for economical design of water curtain system.

Experimental and CFD Simulations of Polluted Air Behavior in Rectangular Tunnels

  • Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권5호
    • /
    • pp.608-615
    • /
    • 2011
  • The objective of this study is to investigate the flow characteristics of polluted air behavior in rectangular tunnels using a PIV system and a commercial CFD program. The PIV experiments are simulated by using the olive oil as the tracer particles in scaled rectangular tunnels. Each model has one of four different outlet vents, each dimensionless L/H ratio of which is 0, 0.375, 0.75 and 1.125, respectively as the locations of each outlet are away from the vertical centerline through the inlet. A commercial CFD program, ANSYS CFX, was used to examine the velocity fields and the pressure distributions in numerical simulations. The kinematic viscosity of the air flow of $1.51{\times}10^{-5}m^2/s$ and the flow velocity of 0.3 m/s at the inlet are given under the same conditions in order to analyze the polluted air flow characteristics experimentally and computationally. This study is considered to examine the effect of the outlet locations in the naturally ventilated tunnel models.

저유량 마취를 위한 전자제어식 기화기 개발 (A Development of the electronic controlled vaporizer for low flow anesthesia)

  • 오영택;박재훈;장인배
    • 산업기술연구
    • /
    • 제29권B호
    • /
    • pp.107-113
    • /
    • 2009
  • For the environmental safety of the operating room and patient healthcare, the closed type rebreathing system is widely adopted. In order to reduce the anesthesia gas during surgery, the mixing ratio of anesthesia gas with breathing air should be precisely controlled. Generally, the breathing air passes through the vaporizer to mix the anesthesia gas, but there is a difficulty in controlling the mixing ratio precisely. In this paper, the stand-alone style vaporizer is designed and the operating characteristics are investigated. The vaporizer measures the temperature and pressure in the vaporizing chamber and chamber temperature is precisely controlled by proportional controlled heater. Exact quantity of anesthesia media is feeded by PID controlled peristaltic pump and vaporized gas is mixed with breathing air flow by PWM controlled solenoid valve. The experimental result shows that the vaporizer has an excellent command following performances that it can be applied to the low flow anesthesia system.

  • PDF