• Title/Summary/Keyword: air-dry

Search Result 1,458, Processing Time 0.033 seconds

The Fabrication of BaZrO3-based Proton Conductors and their Electrical Properties by Dopants (BaZrO3계 수소이온 전도체의 제조 및 첨가물에 따른 전기적 특성)

  • 권정범;유광수
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.5
    • /
    • pp.415-422
    • /
    • 2003
  • BaZr $O_3$-based proton conductors in which B-site cations are partially substituted by Ce and Yb were fabricated by a solid state reaction method. The electrical properties of the specimens were measured by using impedance analyzer in dry air and wet air atmospheres. The electrical conductivity showed higher value in wet air than in dry air at below $600^{\circ}C$. As the Ce content increased, the electrical conductivity increased. Among four compositions, BaZ $r_{0.8}$C $e_{0.15}$Y $b_{0.05}$ $O_3$$_{-{\delta}}$ specimen showed the highest electrical conductivity,1.72$\times$10$^{-3}$ S$cm^{-1}$ /, at 80$0^{\circ}C$. In the low temperature region, the electrical conductivity was higher in wet air than in dry air. However, as the temperature increased, the proton conductivity reduced and thus the electrical conductivity showed similar value at approximately $700^{\circ}C$.

Estimation of PCBs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS) (소나무잎을 Passive Air Sampler(PAS)로 이용하여 대기 중 PCBs 농도 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.4
    • /
    • pp.360-368
    • /
    • 2012
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) of atmospheric Polychlorinated Biphenyls (PCBs). Methods: PCB concentrations in ambient air ($C_a$, ng/$m^3$) and deposited on pine needles ($C_p$, ng/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using a low volume PUF active air sampler and the overall average air volume was about 900-1,000 $m^3$. Pine needles were collected at the end of August and December near the air sampler. Results: $C_a$ were higher at higher air temperature and lower chlorinated PCB congeners, but $C_p$ showed irregular distribution. The average PCB sampling rates from air to pine needles were 0.116 (0.002-0.389) $m^3$/day - g dry. Conclusions: A poor correlation was shown between $C_a$ and $C_p$. However, a good correlation was shown between the logarithm of octanol-air partitioning coefficient ($logK_{oa}$) and log ($C_p/C_a$), and the interrelation was better with longer sampling time (June to December) than shorter sampling time (June to August). The average PCB sampling rates from air to pine needles were the lowest with respect to PUF disk, XAD-2 resin and semipermeable membrane devices (SPMDs) PAS. The average ratio ($C_{a-calc}/C_{a-meas}$) of calculated ($C_{a-calc}$) and measured ($C_{a-meas}$) PCB concentration was 0.69 with a shorter sampling time and 1.24 with a longer, so $C_{a-calc}$ was close to $C_{a-meas}$. It was found that pine needles can be used as PAS of atmospheric PCBs, and are especially suitable for long-time PAS.

The Numerical Simulation of Dry Deposition Velocity Of O3 using Land-Use Information in the Busan Metropolitan City (지표면 특성을 고려한 부산지역의 건성침적속도 예측)

  • 문난경;이화운
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.925-931
    • /
    • 2002
  • Land-use types should be included in air pollutant diffusion model because a complex mixture of various land-use patterns with computational grid can make errors in calculation of several parameters. However, the air pollutant diffusion model has generally been treated with a uniform component with land-use type in each mesh because of the complexity of the simulation. This study presents a numerical simulation of the horizontal distribution of $O_3$dry deposition velocity during summertime in Busan metropolitan city. The calculation of the meteorological field was conducted using the land cover data. Simulation has been performed by the following two scenarios : (1) one with current land cover data, and (2) the other with only land and sea for the surface characteristics. The results from each scenario reveals considerable differences on the meteorological fields and these differences can cause changes in the calculation values of $O_3$deposition velocity.

A Study on the Characteristics of Total Heat Exchanger under Various Conditions (운전조건에 따른 전열교환기의 성능특성 연구)

  • Bail Cheol-Ho;Lim Young-Heon;Gulnora Diuraeva;Park Ji-Yeol;Kwak Kyung-Min;Chu Euy-Sung;Kim Young-Saeng;Kim Jee-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.10
    • /
    • pp.891-897
    • /
    • 2005
  • The characteristics of energy Performance for total heat exchanger have been investigated under various conditions. In cooling operation the latent and enthalpy efficiency are affected by the difference of absolute humidity ratio between indoor and outdoor air. In addition to this the characteristics of absorbing material in the element affects the energy performance. Low dry bulb temperature of indoor air or high absolute humidity ratio in outdoor air give high latent and enthalpy efficiency even with the same temperature difference of dry bulb temperate between indoor and outdoor air.

Performance Test for a Horizontal Regenerative Evaporative Cooler (수평형 재생증발식 냉방기의 성능시험)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

The Influence of Office Indoor Air Qualitys on the Dry Eye Symptom of Contact Lens Wearers (사무실 실내공기질과 콘택트렌즈 착용여부가 안구 건조증에 미치는 영향)

  • Kim, Dea Jong;Park, Moon Chan;Lee, Se Hoon;Kim, Hyun Uk;Lee, Wha Ja;Cha, Jung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.215-222
    • /
    • 2012
  • Purpose: This study was performed to investigate the influence of indoor air qualities of an office environment on dry eye syndrome for wearing contact lens and non-wearing contact lens. Methods: To study the effects of indoor air qualities on dry eye syndrome for seventy-one subjects, $CO_2$, temperature, humidity, TSP, PM10, HCHO were measured. Each subject was tested by a McMonnie's dry eye syndrome questionnaire, a Schirmer Tear Test-I (S.T.T-I), a Schirmer Tear Test-II with anesthetics (S.T.T-II), and Tear film break-up time (T.B.U.T) in the their offices. Results: There was significant relation between the indoor air quality and dry eye syndrome for wearing contact lens and non-wearing when TSP was over $200{\mu}g/m^3$, PM10 was higher than $86.7{\mu}g/m^3$ and Formaldehyde was over $0.4{\sim}1.0{\mu}g/m^3$. However, there was no significant effect on dry eye syndrome with $CO_2$ (p=.0146), temperature (p=0.074) and humidity (p=0.053). Conclusions: It was indicated that $CO_2$, temperature and humidity were no effect on dry eye syndrome in the office environment. However TSP, PM10, formaldehyde, and wearing contact lens were effect on dry eye syndrome. Therefore, the entire management of wearing contact lens and the individual evaluation of the indoor air quality are required.

Experimental Study and Process Optimization for Vibration-assisted Dry Micro-WEDM (진동을 이용한 건식 마이크로-WEDM 에 대한 실험적 연구 및 프로세스 최적화)

  • Hoang, Kien Trung;Yang, Seung-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.3
    • /
    • pp.215-222
    • /
    • 2014
  • This paper presents an experimental study of a vibration-assisted dry micro-wire electrical discharge machining (${\mu}$-WEDM) utilized in high precision and micro-manufacturing area. The assisted vibration was applied to the workpiece using a piezoelectric actuator, and high pressure air was injected directly into the machining gap through a nozzle. Investigation experiments were performed to estimate the importance of input parameters and it was observed from experiment results that the width (kerf) of the cutting slot and the machining time were significantly affected by the air injection pressure and input energy. Moreover, it was also observed that there exists an optimal relationship between the machining time and input parameters including the air pressure and vibration frequency and amplitude. Central composite design based experiments were also carried out, and empirical models of the machining time and cutting slot kerf have been developed using the response surface methodology to analyze and optimize the process.

AC Breakdown Analysis by Epoxy Thickness in Composite-Insulation (복합절연물내의 에폭시 두께에 따른 AC 절연파괴 분석)

  • Jung, Hae-Eun;Yun, Jae-Hun;Kim, Byoung-Chul;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.468-469
    • /
    • 2007
  • $SF_6$ gas used widely as insulating component in electric power industry has excellent in insulation and arc extinguishing performance in gas-insulated switchgear. However, the concern about eco-friendly alternative gas is currently rising, because $SF_6$ gas is one of the main greenhouse gases. As one of the study for $SF_6$ free technology, composite-insulation technology is focused in this paper. To analyze the influence by epoxy thickness change, the composite-insulation composed of dry-air and epoxy was used in this paper. To analyze AC breakdown by the epoxy thickness, needle-plane electrode was used and needle was molded by epoxy. Under the gas pressure ranged from 0.1 to 0.6MPa, the breakdown voltage of dry-air were measured in AC electric field. The data of composite-insulation were acquired by changing the thickness of epoxy used in each composite-insulation under the same condition.

  • PDF

Inactivation of Indoor Airborne Fungi Using Cold Atmospheric Pressure Plasma (저온 대기압 플라즈마의 실내공기 중 곰팡이 생장억제 효과)

  • Paik, Namwon;Heo, Sungmin;Lee, Ilyoung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.351-357
    • /
    • 2019
  • Objectives: The objectives of this study were to investigate fungal contamination in a 31-year old university building in Seoul, Korea, and to study the inactivation of fungi using cold atmospheric pressure plasma(CAP). Methods: To investigate the fungal contamination in a university building, air samples were collected from five locations in the building, including two study rooms, a storage room, a laboratory, and a basement. The sampling was performed in a dry season(February to April) and in a wet season(July). To study the inactivation efficacy of fungi by CAP, airborne fungal concentrations were measured before and after the operation of the CAP generator. Results: Humidity was an important factor affecting fungal growth. The airborne fungal concentrations determined in the wet season(July) were significantly higher than those determined in the dry season(February to April). In the basement, the values determined in the dry and wet season were 319 and $3,403CFU/m^3$, respectively. The inactivation efficiency of fungi by CAP was 83-90% over five to nine days of operation. Conclusions: The university building was highly contaminated by airborne fungi, especially in summer. It is concluded that humidity is an important factor affecting fungal growth and CAP is a highly useful technique for inactivation of indoor airborne fungi.

Indefinite sustainability of passive residual heat removal system of small modular reactor using dry air cooling tower

  • Na, Min Wook;Shin, Doyoung;Park, Jae Hyung;Lee, Jeong Ik;Kim, Sung Joong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.964-974
    • /
    • 2020
  • The small modular reactors (SMRs) of the integrated pressurized water reactor (IPWR) type have been widely developed owing to their enhanced safety features. The SMR-IPWR adopts passive residual heat removal system (PRHRS) to extract residual heat from the core. Because the PRHRS removes the residual heat using the latent heat of the water stored in the emergency cooldown tank, the PRHRS gradually loses its cooling capacity after the stored water is depleted. A quick restoration of the power supply is expected infeasible under station blackout accident condition, so an advanced PRHRS is needed to ensure an extended grace period. In this study, an advanced design is proposed to indirectly incorporate a dry air cooling tower to the PRHRS through an intermediate loop called indefinite PRHRS. The feasibility of the indefinite PRHRS was assessed through a long-term transient simulation using the MARS-KS code. The indefinite PRHRS is expected to remove the residual heat without depleting the stored water. The effect of the environmental temperature on the indefinite PRHRS was confirmed by parametric analysis using comparative simulations with different environmental temperatures.