• Title/Summary/Keyword: air void

Search Result 263, Processing Time 0.028 seconds

One-Dimensional Analysis of Air-Water Two Phase Natural Circulation Flow (공기와 물의 이상 자연순환 유동의 1 차원 해석)

  • Park, Rae-Joon;Ha, Kwang-Soon;Kim, Jae-Cheol;Hong, Seong-Wan;Kim, Sang-Baik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2626-2631
    • /
    • 2007
  • Air-water two phase natural circulation flow in the T-HERMES (Thermo-Hydraulic Evaluation of Reactor cooling Mechanism by External Self-induced flow)-1D experiment has been evaluated to verify and evaluate the experimental results by using the RELAP5/MOD3 computer code. The RELAP5 results have shown that an increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not effective on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. The water level is not effective on the water circulation mass flow rate. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it is not effective on the local pressure.

  • PDF

Variation of Image Analysis Results for Determining the Characteristics of the Air-Void System on Hardened Concrete (콘크리트 공극구조 분석을 위한 화상분석결과의 변동성 분석)

  • Jeon, Sung-Il;An, Ji-Hwan;Lee, Jin-Beom;Kwon, Soo-Ahn
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.157-168
    • /
    • 2011
  • Recently, the cases of freeze-thaw distress on concrete pavement in domestic have been reported periodically. Hereupon, the necessity to establish the standard of spacing factor came to the fore. The test method for analyzing spacing factor is provided in the standard of ASTM C 457. Since researchers tend to judge study results subjectively, the results should be revised throughly. Image analysis program for determining the characteristics of air-void system on hardened concrete identify air void through the difference of a color. The pixel intensity values used in this program have a significant effect on the analysis results. This study compared the automated void count by varying pixel intensity values with the manual void count in order to determine the optimum range of pixel intensity values. Also, this study analyzed the air-void characteristics on eight kinds of concrete mixtures. In this study, it was confirmed that the variation of void counted manually was around 10% from the results of round robin test, and that the optimum range of pixel intensity values is around 80~90. And it was also confirmed that air content (as a whole) was increased generally and spacing factor was decreased by increasing air-entrainer content. But some concrete mixtures showed a tendency that air content was constant and spacing factor was decreased by increasing air-entrainer content. This causes the air entrained by air-entrainer has more influence on spacing factor than air content. Also, the deviation of spacing factor by cutting position of concrete specimen was about 30~100${\mu}m$ because of the limit of 2-D image analysis. The additional study about variation of spacing factor by cutting position of concrete specimen will be performed later.

A Study on Permeability and Air-void System of Recycled Aggregate Concrete (재생골재를 사용한 콘크리트의 수밀성과 기포조직에 관한 연구)

  • 신윤섭;민찬식;최세규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.439-444
    • /
    • 2001
  • In many countries a considerable amount of demolition wastes is generated and wastes concrete constitutes a significant proportion of the construction waste. Therefore, the necessity for the use of recycled aggregate in concrete arise and the reuse of a waste concrete may solve the problems of environmental pollution and shortage of natural aggregate. The Purpose of the present study is to investigate the effects of the recycled aggregate on the compressive strength, the permeability and the air-void system.

  • PDF

A Study on Strength and Packing Characteristics of Top-Down Joint in Field Experiment (현장실험을 통한 역타설 이음부의 강도 및 충전특성에 관한 연구)

  • 강동현;김종구;김병천;박병근;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1101-1106
    • /
    • 2000
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is to find a solution of removing void and air, way to exhaust air in top down column. through specimen concrete placing experiment.

A study on the measurement of void fraction using gamma ray (감마선을 이용한 기포율측정에 관한 연구)

  • Nam, Pyong-Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.9 no.1
    • /
    • pp.13-23
    • /
    • 1980
  • sing the physical characteristics of nuclear radiation penerated into the cross section of the measurement of void fraction in saturated vapor & water passing through the is analyzed theoretically and the solutions are achieved by means of computer simulation. These theoretical results are also approved through the experiment with the simulators.

  • PDF

A Study on the Expansion of Contemporary Fashion (현대 패션에 나타난 부피 확장에 대한 연구)

  • Choi, Soo-Hyun
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.2 s.111
    • /
    • pp.155-171
    • /
    • 2007
  • Exaggerated expressions of contemporary fashion have exceeded historical precedents in volume. The purpose of this study is to understand the aesthetic characteristics of expanded form In contemporary fashion. To take dresses beyond their flat shapes into three-dimensional forms, it was investigated into volume of dresses by using the void and the mass. The void Is rarefied space and the mass is densified space. The void of dresses could be constructed from the boning such as panier and stiff textiles as organza lining. The mass could be constructed from padding. Fold, pleats, twist, and the layering of fabrics show features of both the void and the mass. Contemporary fashion designers relied on the void rather that the mass to make the enormous volume because of the weight of the mass. X-silhouette and the expansion of skirt and sleeve were dominant as the result of accentuating the body with a waistline. However, many of expanded dresses were so voluminous that they obscured the body's outlines. Some forms were strange and shocking. Many designers explored the void and there were a multitude of methods to construct the void: compartments of air, architectural techniques, technical textiles, fold such at origami. The aesthetic consciousness of expanded dresses could be classified into 7 categories, the giant, the dynamic, the deconstructive, the historical, the comedic, the rhythmical, and the technical character.

Analysis of Air Voids System Using Image Analysis Technique in Hardened Concrete (화상분석법을 통한 경화 콘크리트의 미세 공극 구조 분석)

  • Yun Kyong-Ku;Jeong Won-Kyong;Jun In-Koo;Lee Bong-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.741-750
    • /
    • 2004
  • Air voids in hardened concrete have an important influence on concrete durability such as freeze-thaw resistance, surface scaling resistance, and water permeability, and they have been characterized by spacing factor Linear traverse and point count methods in ASTM standard have been used in estimating an air void system in hardened concrete. However, these methods require lots of time and efforts, further they are not repeatable. Image analysis method could be utilized In estimating an air void systems in hardened concrete with a developments of microscope, digital camera and computer program. The purpose of this study was to develope image analysis method and provide a guideline by comparing the results from ASTM method and image analysis method. The concerns were at air void content and diameter distribution, air voids system as well as spacing factors. The experimental variables included air content by air entrained agent (0, 0.01, $0.03\%$) and depth of specimen (top, middle, bottom). The result showed that it was possible to calculate spacing factor using image analysis technique, as well as air content, air diameter distribution, and air structure. This study also contributed in developing an reasonable and repeatable image analysis method.

Experimental study on the flow characteristic by the co-polymer A6l1P additive in gas-liquid two-phase vertical up flow (합성 고분자물질 A611P를 첨가한 기액 2상 수직상향의 유동특성에 관한 실험적 연구)

  • 차경옥;김재근;양회준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.398-410
    • /
    • 1998
  • Two-phase flow phenomena are observed in many industrial facilities and make much importance of optimum design for nuclear power plant and the liquid transportation system. The particular flow pattern depends on the conditions of pressure, flow velocity, and channel geometry. However, the research on drag reduction in two-phase flow is not intensively investigated. Therefore, experimental investigations have been carried out to analyze the drag reduction and void fraction by polymer addition in the two-phase flow system. We find that the polymer solution changes the characteristic of two-phase flow. The peak position of local void friction moves from tile wall of the pipe to the center of the pipe when polymer concentration increase. And then we predict that it is closely related with the frau reduction.

  • PDF

Visualization of Gas/liquid Ejector Flow and Void Fraction Measurement using Fiber Optic Probe (기체-액체 이젝터 유동의 가시화와 광섬유 탐침에 의한 기포분율 측정)

  • Choi, Sung Hwan;Ji, Ho Seong;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.1
    • /
    • pp.34-40
    • /
    • 2013
  • Gas/liquid two-phase ejector is a device without moving parts, in which liquid is used to drive gas of a low-pressure source. In this paper, the hydrodynamic characteristics of a vertical down type two-phase ejector were studied using an air-water loop system. Entrained air flow rates were measured with inlet and outlet pressures of the ejector with varying water flow rate. Homogeneous bubbly flows in the discharge pipe were confirmed by the high speed flow visualization method. Quantitative measurements of void fraction were made using a newly developed fiber optic probe system.