• Title/Summary/Keyword: air void

Search Result 263, Processing Time 0.027 seconds

Air-coupled ultrasonic tomography of solids: 1 Fundamental development

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.17-29
    • /
    • 2016
  • Ultrasonic tomography is a powerful tool for identifying defects within an object or structure. But practical application of ultrasonic tomography to solids is often limited by time consuming transducer coupling. Air-coupled ultrasonic measurements may eliminate the coupling problem and allow for more rapid data collection and tomographic image construction. This research aims to integrate recent developments in air-coupled ultrasonic measurements with current tomography reconstruction routines to improve testing capability. The goal is to identify low velocity inclusions (air-filled voids and notches) within solids using constructed velocity images. Finite element analysis is used to simulate the experiment in order to determine efficient data collection schemes. Comparable air-coupled ultrasonic signals are then collected through homogeneous and isotropic solid (PVC polymer) samples. Volumetric (void) and planar (notch) inclusions within the samples are identified in the constructed velocity tomograms for a variety of transducer configurations. Although there is some distortion of the inclusions, the experimentally obtained tomograms accurately indicate their size and location. Reconstruction error values, defined as misidentification of the inclusion size and position, were in the range of 1.5-1.7%. Part 2 of this paper set will describe the application of this imaging technique to concrete that contains inclusions.

Thrust Bearing Design for High-Speed Composite Air Spindles (고속 복합재료 공기 주축부를 위한 추력베어링 설계)

  • Bang, Kyung-Geun;Lee, Dai-Gil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.10
    • /
    • pp.1997-2007
    • /
    • 2002
  • Composite air spindles are appropriate for the high-speed and the high-precision machining as small hole drilling of printed circuit board (PCB) or wafer cutting for manufacturing semiconductors because of the low rotational inertia, the high damping ratio and the high fundamental natural frequency of composite shaft. The axial load and stiffness of composite air spindles fur drilling operation are determined by the thrust ben ring composed of the air supply part mounted on the housing and the rotating part mounted on the rotating shaft. At high-speed rotation, the rotating part of the thrust bearing should be designed considering the stresses induced by centrifugal force as well as the axial stiffness and the natural frequency of the rotating shaft to void the shaft from failure due to the centrifugal force and resonant vibration. In this work, the air supply part of the thrust bearing was designed considering the bending stiffness of the bearing and the applied load. The rotating part of the thrust bearing was designed through finite element analysis considering the cutting forces during manufacturing as well as the static and dynamic characteristics under both the axial and con trifugal forces during high-speed rotation.

Plant-scale experiments of an air inflow accident under sub-atmospheric pressure by pipe break in an open-pool type research reactor

  • Donkoan Hwang;Nakjun Choi;WooHyun Jung;Taeil Kim;Yohan Lee;HangJin Jo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1604-1615
    • /
    • 2023
  • In an open-pool type research reactor with a downward forced flow in the core, pipes can be under sub-atmospheric pressure because of the large pressure drop at the reactor core in the atmospheric pool. Sub-atmospheric pressure can result in air inflow into the pipe from the pressure difference between the atmosphere and the inside of the pipe, which in a postulated pipe break scenario can lead to the breakdown of the cooling pump. In this study, a plant-scale experiment was conducted to study air inflow in large piping systems by considering the actual operational conditions of an advanced research reactor. The air inflow rate was measured, and the entrained air was visualized to investigate the behavior of air inflow and flow regime depending on the pipe break size. In addition, the developed drift-flux model for a large vertical pipe with a diameter of 600 mm was compared with other correlations. The flow regime transition in a large vertical pipe under downward flow was also studied using the newly developed drift-flux model. Consequently, the characteristics of two-phase flow in a large vertical pipe were found to differ from those in small vertical pipes where liquid recirculation was not dominant.

Evaluation of the Performance and Moisture Retaining Ability in Semi-Rigid Pavement (반강성포장의 성능 및 보수성 평가)

  • Park, Tae-Soon
    • International Journal of Highway Engineering
    • /
    • v.10 no.2
    • /
    • pp.69-79
    • /
    • 2008
  • This study presents the test results on the performance and the moisture retaining ability of semi rigid pavement using the moisture retaining grouting. The two kinds of the grouting materials were used for the Laboratory tests. The method of the tests includes the compression(3 hours and 7 days) and flexural strength(7 days) varying the P lot flow values. The test results show that the variation of the P lot value has no great effects on the strength, however, the different strength was found as the different grouting materials were used. The performance of the semi rigid pavement was evaluated varying the air void ration of the base asphalt pavement. The test results show that the flexural strength of the semi rigid pavement increases with increasing the air void of the base asphalt pavement so that the flexural strength of the semi rigid asphalt pavement can be effected by the air void of the base asphalt pavement. The moisture retaining tests were conducted and compared in the field the comparisons were made with the dense grade asphalt pavement and the semi rigid asphalt pavement with and without spraying the water. The difference of the temperature of the semi rigid pavement with the spraying water has recorded $11^{\circ}C$ when it compared with the dense grade asphalt pavement and $4^{\circ}C$, when it compared with the semi rigid pavement without the spraying the water. It can be seen that decrease the temperature of the pavement by the moisture retaining ability from the semi rigid pavement.

  • PDF

Characteristics of a Small Screw-type Centrifugal Pump Operating in Air-Water Two-Phase Flow (소형 스크류식 원심펌프의 기액 이상류 특성)

  • Kim, You-Taek;Tanaka, Kazuhiro;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.4 s.5
    • /
    • pp.9-15
    • /
    • 1999
  • A screw-type centrifugal pump was manufactured to carry primarily solids and its impeller had a wide flow passage. However, there was an effect on the flow passage shape on delay of the choke due to entrained air not being clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For this reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that there was a loss of pump head from single-phase flow to the choke due to air entrainment near the best efficiency point being large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

  • PDF

Study on Design of Air-water Two-phase Flow Centrifugal Pump Based on Similarity Law

  • Matsushita, Naoki;Furukawa, Akinori;Watanabe, Satoshi;Okuma, Kusuo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.2
    • /
    • pp.127-135
    • /
    • 2009
  • A conventional centrifugal pump causes a drastic deterioration of air-water two-phase flow performances even at an air-water two-phase flow condition of inlet void fraction less than 10% in the range of relatively low water flow rate. Then we have developed a two-phase flow centrifugal pump which consists of a tandem arrangement of double rotating cascades and blades of outer cascade have higher outlet angle more than $90^{\circ}$. In design of the two-phase flow pump for various sized and operating conditions, similarity relations of geometric dimensions to hydraulic performances is very useful. The similarity relations of rotational speed, impeller diameter and blade height are investigated for the developed impeller in the present paper. As the results, the similarity law of rotational speed and impeller diameter is clarified experimentally even in two-phase flow condition. In addition, influences of blade height on air-water two-phase flow performances indicate a little difference from the similarity relations.

A quantitative measurement of concrete air content using image analyses

  • Hwang, C.L.;Peng, S.S.;Wang, E.;Lin, S.H.;Huang, S.L.
    • Computers and Concrete
    • /
    • v.7 no.3
    • /
    • pp.239-247
    • /
    • 2010
  • A proposed topology method is introduced to measure the air content of fresh cement paste and hardened concrete. The method takes advantage of chromatographic analysis in void areas that are highlighted using different color schemes and later calculated using built-in computer software. The air content measured by the topology method is compared with results obtained from the conventional ASTM methods. It is concluded that the proposed method is reliable, and costs less and is easier to operate compared with the ASTM methods. In addition, 3 dimensional pore models can be created using image post-processing techniques. The proposed method helps researchers in understanding the formation and existence of concrete pores. This paper reports a detailed test program demonstrating the standard operating procedure used for the proposed method and presents a comparison of results between the proposed method and conventional ASTM Specifications. It is also concluded that the air content increases with increasing size of pores and increasing percentage of coarse aggregates.

Assessment of MARS Multi-dimensional Two-phase Turbulent Flow Models for the Nuclear System Analysis (발전소 계통해석을 위한 MARS 코드의 다차원 이상 난류 유동 모델 검증계산)

  • Lee S.M.;Lee U.C.;Bae S.W.;Chung B.D.
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.1-7
    • /
    • 2006
  • The multi-dimensional two-phase flow models were developed for analyze the multi-dimensional behaviors or nuclear systems. To verify the simple turbulence model, The single phase mixing problem in a rectangular slab was calculated and compared with the commercial CFD code results. That result shows a good agreement with the CFD result. And the RPI Air-water experiments were simulated to assess the two-phase turbulence model in the multi-dimensional component. The first calculated distribution or void-fraction is highly dispersed and diffusive. It was revealed that the main reason is undesirable stratification force in a horizontal stratified flow regimes. Therefore the horizontally stratified flow regime is deleted because the stratified flow regime is not expected in multi-dimensional flow. With the modification of the flow regime, the predicted flow patterns and void fraction profiles are in good agreement with the measured data.