• Title/Summary/Keyword: air ventilation rate

Search Result 378, Processing Time 0.031 seconds

Analysis Schemes of Wind Ventilation Forest Types - A Case Study of Daegu Metropolitan City - (바람길숲의 유형별 분석 방안 - 대구광역시를 사례로 -)

  • EUM, Jeong-Hee;OH, Jeong-Hak;SON, Jeong-Min;KIM, Kwon;BAEK, Jun-Beom;YI, Chaeyeon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.12-23
    • /
    • 2019
  • This study aims to suggest analysis schemes of urban forests acting as wind ventilation corridor(wind ventilation forest). For this purpose, wind corridor forests were classified into three types: wind-generating forests(WGF), wind-spreading forests (WSF), and wind-connecting forests(WCF), and they were classified into three grades. WGF, WSF and WCF were classified based on the density of forest type map, vegetation index, and ventilation networks, respectively. As a result of analyzing wind corridor forests for Daegu Metropolitan City(883.56㎢), the area of WGF was classified as 443.1㎢ and distributed in the northern and southern regions of Daegu Metropolitan City. Among them, the first grade of WGF occupied the largest area(345.59㎢) and the highest rate(54.44%) in Dalseong-gun. On the other hand, WGF was not found in Jung-gu, because this administrative district is isolated from the forest area. WSF was 32.4㎢, which included representative urban parks of Daegu Metropolitan City, and WSF were found relatively much in Suseong-gu and Dalseong-gun. However, WSF were distributed throughout Metropolitan City, and the vegetation index was not high. The ventilation network that can form WCF included major rivers and roads in Daegu Metropolitan City, but this network was not connected to the urban park from the outer forest. Therefore, it was judged that the formation of WCF connecting WGF outside the city and WSF inside the city would be important. The results of this study can be used as a basic data for systematic wind corridor forest projects, and can be used as basic data for establishing guidelines for wind corridor forest analysis at national and local levels.

A Study on the Removal Efficiency of Harmful Pollutants in the Cooking Chamber (조리실내의 유해오염물질 제거율에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.149-156
    • /
    • 2016
  • The purpose of this study is to reduce the contaminants (total volatile organic compounds (TVOCs), fine particle, odor and total airborne bacteria) during cooking process in cooking chamber, and to decrease the health damage in indoor space that has bad work environment. In order to solve the shortcomings of existing air purifiers and remove all kinds of pollutants effectively, this study focused on the development of indoor air purifiers which are made of bar type. Bio-ceramics filter which combines activated carbon and loess. The air cleaners developed with 4 measuring items including TVOCs, particulate matter, complex odor and total airborne bacteria were measured comparing their pre-service test to their post-service test after a period of time. The measured results showed higher removal efficiency of 91.02% as the concentration of TVOCs was reduced from $2,500{\mu}g/m^3$ to $223{\mu}g/m^3$. Second, the particulate matter removal ratio was 97.51% efficient with average concentration of $26.68{\mu}g/m^3$. Third, the odor showed 95.20% reduction as air dilution ratio averaged out at 144. Last, total airborne bacteria was eliminated by over 94% showing the changeable concentration from $787{\sim}814CFU/m^3$ to $47{\sim}40CFU/m^3$. In addition, the removal rate of harmful pollutants is excellent, and it is expected that the environment of the existing poor cooking room will be greatly improved by using the developed air purifier in combination with the ventilation device and the stove hood.

Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents (HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가)

  • Yoon, Churl;Park, Jin-Hee;Hwang, Mee-Jeong;Han, Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.553-562
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) analysis has been performed to estimate the air temperature inside an Auxiliary Feed Water (AFW) Motor-Driven (MD) pump room for the case where there is loss of Heating, Ventilation, and Air-Conditioning (HVAC). A transient calculation for the closed pump room without cooling by any HVAC system shows that the volume-averaged air temperature reaches around $60^{\circ}C$ for a transient period of 8.0 h. From previous studies, the external air and surface boundary temperatures are assumed to increase slowly starting from an initial temperature of $35^{\circ}C$. For the cases where the door is opened at 2, 4, and 6 h after the initiation of HVAC failure, the average air temperature promptly drops by about $4^{\circ}C$ when the door is opened and then slowly increases. The current calculations based on the CFD technique predict the rate of increase of air temperature to be lower than that determined by previous conservative calculations on the basis of a lumped model.

Study on Hospital Environmental Causes Affected the Mother′s Comfort After Her Child Birth (산욕부 안위에 영향을 미치는 병원환경 요인에 관한 연구)

  • 변수자
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.1
    • /
    • pp.1-15
    • /
    • 1978
  • The Purpose of this study is to examine closely the causes influenced upon the comfort and recovery of the woman delivered of a child in the hospital at the same time to understand environmental status of hospitals in order to promote mother's health recovery, and to improve hospital environment by emphasizing the meaning of environment and health before the medical staff and hospital administrative authority. In the method of servery of the research, 165 post paestum patients have been randomly selected who were accommodated and delivered their babies at OB(obstetric ) & GY (Gynecologic) unit the 7 general hospitals for the period of 6 December 1976 through 17 December 1976. As for the survey, it has been used of Questionnaire where we have 65 items in the respect of personal environment in the hospital such as trusting nurse, ability, reliability, kindness and etiquette of nurse and tile character of nurse the relationship with patients the other respect of physical environment included 9f temperature, moisture. air-ventilation lightening noise, cleanness. facilities, and the third realm being of mother's hearth ground to have the following conclusion 1. The feature of the collected personnel they are from OB or GY sects of from OB unit of the other 5 hospitals except the two general hospitals of the college or school Otherwise the rate of the patients to nurses would be 9 : 1. As for the nurses'ground it would be appeared of 20-25 years of age as the 76%. either 3 year course or 4 year course in the education would be each 50% and less than 2 year experience case would record as of 60 %. In the respect of hospital physical environmental status, there we have two hospitals without any thermometers, on the other han4 nowhere there's hygrometer, otherwise, the lightening is normal or over than normal As for the structure of noise protection the corridors're, generally speaking worse than rooms, nerver hueless, there's no ventilating system in the hospitals. The rooms'repainted in white and yellow, light green white, or green color. The patient's clothing were in green pink blue, light green or in white co for. There're not anything special in both decoration and equipments. Most of them used tall beds except in one hospital 2. To the extent of perception of patient's hatch 9round and hospital environment it is presented that they perceived nurse's ability in highest in total human variable, though perceived kindness or etiquette in the lowest otherwise, comparatively high in total average. 3. In the respect of physical environment it is highest perceived of lightening terms, otherwise, lowest perceived of air ventilation and total average became lowest than the one of the original record 4. To ages, in the respect of hatch ground rather old aged mother than the younger one has perceived that nurse would be trusting, in good service character, able, at the same time, liable, Otherwise, in physical environment regardless of age, they perceived lightening in high and remarkably lower in ventilation As a result of the examination of the difference in hospital environment to each age it is appeared of statistical difference at 5% level of ability in the personal environment otherwise little difference as for physical environment 5. In the respect of perceiving level to educational standard it is highly perceived of personal environment for higher ranking group rather than lower group in the educational standard. In case of physical environment it is highly perceived for lower level group rather than higher level group in educational background. The variables which have statistical significance at 5% level are from trusting kindness, etiquette and total kindness, etiquette and total all significance at 5% level are from trusting, kindness, etiquette and total human environment variable in personal environment, otherwise, there's little difference in the physical environment. 6. The perceiving level due to times of admission and accommodation at the hospital would be cleared out as gradual higher perception both physical and personal environment in the hospital. At 5% significant level of the ventilation condition in physical environmental variable it is presented of meaningful difference otherwise, there we have little difference both in Personal variable and other one. 7. In accordance with living standard, the perception degree of personal environment in tee hospital would be inclined to increase to higher living standard on the other hand, in case of the physical environment, the perception level world increase to lower living standard At 5 % level, the trustuariable and total scores in the personal eicuironmectal variable there appeared a meaningful/ significant difference otherwise, there presented little difference both in physical environmental and other variable to the living standard 8. Pertaining to family unit, the mother of an independent family unit perceived highly in all respect of the personal and the physical environment in the hospital rather than the woman of succeeding family unit. At 5 % level there appeared a difference in the respect of kindness and etiquette both in personal environment variable, on the other hand, there hardly marked a difference between other variable and physical environmental one. 9. The degree of perception to comforting level has little connection with a statistical difference the age, educational level hospital admitting times, living standard or family unit. 10. The most effective variable to mother's comforting level will be nurse's ability, reliability, trusting manner, and total physical environment variable in order.

  • PDF

A Survey on the Actual Conditions of Summer Working Uniforms for Contracted Foodservice Workers (위탁급식업체 종사자의 하절기 작업복 착용 실태에 관한 연구)

  • Lee, Hyo-Hyeon;Yeom, Jeong-Ha;Choi, Jeong-Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.4
    • /
    • pp.553-562
    • /
    • 2010
  • This survey investigates the conditions of summer working uniforms for contracted foodservice workers. The data were obtained from 67 workers through in-depth interviews (July 2005~October 2005). The results of study are as follows: The working environment changed to menu and cooking method (air temperature $28\sim37^{\circ}C$, humidity 72~86 %RH, radiant temperature $27\sim37^{\circ}C$, air velocity 0.14~0.37m/sec). They answered that the working environment has high temperatures, humidity, excessive noise, and liability to slide. The typical accidents were burns, cuts, slide, and ligament injuries in the workplace. Work duties consisted of cooking, serving food, washing, and cleaning up leftover food. All the employees carried out multi tasks. The primary working postures and motions were standing, crouching, and lifting. The female workers usually wore underwear (panty and brassiere), upper and lower work wear, aprons, waterproof-aprons, cotton-gloves, rubber-gloves, socks, and rubber-boots. The satisfaction of the uniform was relatively low for trousers and waterproof-aprons. The answer about the fit was generally "comfortable." They answered "back," "chest," and "head" were wet with perspiration during work. The uncomfortable parts were the crotch and neck. Questions concerning their satisfaction with the material of uniforms indicated a high rate of dissatisfaction, particularly for ventilation and absorbency. In case of the colors of the working uniform, workers preferred white color for the upper part, and black color for the lower part.

Investigation "On the Paddy Storage at the Farm Level" (농가의 미곡저장실태)

  • 김용환;서상용;김성태;나우정;민영봉
    • Journal of Biosystems Engineering
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1980
  • This study was carried out to investigate the actual environmental paddy storage conditions in conventional Korean farm warehouses. The paddy storage conditions by the locations and sizes of warehouses were figured out. The effectiveness of the small insulated box for storing paddy was also examined. Observations were made at sixteen different warehouses located in Moonsan-Myeon, Jinyandg-gun, Gyungnam Province from July lst to September 28 th, the period which was considered to be the worst for storing grains. The results are as follows ; 1. the average temperatures of rough rice and air inside the warehouse were 0.9 and 0.7$^\circ$ higher than the outside air temperature. 2. The average relative humidity in warehouses was 1.5percent higher than that of the atomosphere. This fact resulted in the increased moisture content of grains. Therefore, the ventilation for equalizing the relative humidity of inside and outside of warehouses was required. 3. The dry matter of stored rough rice was decreased by 1.1 percent in average druing the observation period. In order to reduce the dry matter loss, application of new grain storing method ;hermetic storage or filling inert gas storage, was highly recommended. 4. Environmental conditions for storing rough rice in a warehouse located in a sloping site are, in general , better than those of a warehouse located in a flat site. But as far as the dry matter of rough rice was concerned, above situation is not always satisfactory. Because it is fairly frequent to observe the higher rate of moisture absorption by grains stored in a warehouse located in a sloping site. 5. Environmental conditions for storing rough rice in a large-scale warehouse were better than those in a small size warehouse. Therefore, it is advisible for farmers to store their grins in the large-scale warehouses commonly used by villagers. 6. It was undesirable to store rough in a insulated box.

  • PDF

Prevalence of Children's Allergic Diseases in Ulsan: Local Differences and Environmental Risk Factors (울산지역 초등학생 알레르기 질환 유병률: 지역적 차이와 환경위험인자)

  • Oh, In-Bo;Kim, Yangho;Sim, Chang Sun;Lee, Ji Ho
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.472-481
    • /
    • 2012
  • Objectives: This study aims to investigate the AD (allergic diseases: asthma, allergic rhinitis and atopic dermatitis) prevalence among elementary schoolchildren in an industrial city, Ulsan, and identify major environmental risk factors associated with AD prevalence. Methods: Data on the physician-diagnosed prevalence over the past 12 months and potential risk factors of AD were collected through a questionnaire from a 2009-2010 survey of 4,067 schoolchildren living in different urban environments. The logistic regression analysis was performed to assess differences in AD prevalence among the areas and to determine which environmental factors impacted AD. Results: Our survey results showed that the AD prevalence rate ranged between 26.2% and 35.9%. Children living in polluted areas (near industrial and central urban areas) had about a 10% higher prevalence of AD than did those living in coastal or suburban residences. The Chi-Square test demonstrated that this local difference was statistically significant before and after adjustment of major confounders such as parental AD history and parental education. The results of the logistic regression analysis showed a statistically significant association between several environmental factors (ventilation in winter, odor conditions and exposure to traffic smoke, and outdoor $PM_{10}/O_3$ pollution) and the prevalence of AD found by multivariate model after adjusting confounders. Conclusion: These results suggest that local differences in AD prevalence are significantly associated with outdoor environmental factors. Although there are likely to be other risk factors for AD, living in a polluted area and exposure to high levels of air pollutants can contribute to an increased risk of childhood AD.

Effects of Shading Rate and Method of Inside Air Temperature Change in Greenhouse (차광율 및 차광방법이 온실내부의 온도변화에 미치는 영향)

  • 이석건;이현우;김길동;이종원
    • Journal of Bio-Environment Control
    • /
    • v.10 no.2
    • /
    • pp.80-87
    • /
    • 2001
  • This study was conducted to provide basic data for the design of shading facility of greenhouse. The proper distance between external shading screen and roof surface, transmissivity of shading materials, and shading effects of external and internal shadings were analyzed. About a distance of 10 cm between inclined external shading screen and roof surface was enough to guarantee the external shading effect in the greenhouse without roof vent. The inside temperature of greenhouse installed with 85% internal shading screen was lower the maximum of 4$^{\circ}C$ and mean of 2$^{\circ}C$ than that with 55% internal shading screen in both natural ventilation and no ventilation condition. The difference of soil temperature between shading and no shading greenhouse was great, but the difference by shading rate or shading method was small. The performance of external shading for controlling inside temperature down was superior to that of the internal shading. The externally inclined shading screen parallel to the roof surface of greenhouse was more effective than the externally horizontal shading screen in controlling inside temperature of greenhouse without roof vent.

  • PDF

Analysis of Changes and Factors Influencing IAQ in Subway Stations Using IoT Technology after Bio-Filter System Installation (IoT 기반 지하역사 내 바이오필터시스템 설치에 따른 실내공기질 변화 및 영향 요인 분석)

  • Yang, Ho-Hyeong;Kim, Hyung-Joo;Bang, Sung-Won;Cho, Heun-Woo;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.410-424
    • /
    • 2021
  • Background: Subway stations have the characteristics of being located underground and are a representative public-use facility used by an unspecified number of people. As concerns about indoor air quality (IAQ) increase, various management measures are being implemented. However, there are few systematic studies and cases of long-term continuous measurement of underground station air quality. Objectives: The purpose of this study is to analyze changes and factors influencing IAQ in subway stations through real-time continuous long-term measurement using IoT-based IAQ sensing equipment, and to evaluate the IAQ improvement effect of a bio-filter system. Methods: The IAQ of a subway station in Seoul was measured using IoT-based sensing equipment. A bio-filter system was installed after collecting the background concentrations for about five months. Based on the data collected over about 21 months, changes in indoor air quality and influencing factors were analyzed and the reduction effect of the bio-filter system was evaluated. Results: As a result of the analysis, PM10, PM2.5, and CO2 increased during rush hour according to the change in the number of passengers, and PM10 and PM2.5 concentrations were high when a PM warning/watch was issued. There was an effect of improving IAQ with the installation of the bio-filter system. The reduction rate of a new-bio-filter system with improved efficiency was higher than that of the existing bio-filter system. Factors affecting PM2.5 in the subway station were the outdoor PM2.5, platform PM2.5, and the number of passengers. Conclusions: The IAQ in a subway station is affected by passengers, ventilation through the air supply and exhaust, and the spread of particulate matter generated by train operation. Based on these results, it is expected that IAQ can be efficiently improved if a bio-filter system with improved efficiency is developed in consideration of the factors affecting IAQ and proper placement.

Changes in Circulatory and Respiratory Activities Observed on Men in an Engine Room of a Navy Ship (함정 기관실내 활동의 순환 및 호흡 기능에 대한 영향)

  • Hyun, Kwang-Chul;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.199-213
    • /
    • 1967
  • Circulatory and respiratory activities were observed in men exposed to the environment of engine room of a cruising Republic of Korea Navy ship and compared to the control values obtained in an ordinary laboratory room on land. The environment of an engine room of cruising navy ship was presumed to be a multiple stress acting on men. The environment of the engine room included high temperature $(35-42^{\circ}C)$, low relative humidity (20-38% saturation), vibration (about 7 cycles per second), rolling and pitching of ship and noises. Sixteen men were divided into two groups consisted of each 8 subjects. Subjects of sea duty group had experience of continuous on board duty averaging 3.5 years. Men of land duty group had no experience of on board activity. On land observations were made on one day prior to the boarding and leaving the port and four days after landing. In between observations in the engine room were made on the first, 5 th, 9 th, 12 th, and 14 th day of on board activity. The whole experimental period lasted for 20 days. Measurements on circulatory and respiratory parameters were at standing resting state (after 30 minutes standing in the case of on land study and 15 minutes in engine room study) and within one minute after cessation of on the spot running of which rhythm was 30/min. and lasted for 5 minutes. Oxygen consumption and pulmonary function test were done in the period of two minutes from the 3rd to 5th minutes of running. The following results were obtained. 1. Body temperature showed no change regardless of group difference or on land or on board measurements. 2. Pulse rate increased markedly after boarding the ship id both groups. Pulse rate increased from the first day on board at rest and after exercise as compared to the on land control value. This increase in pulse rate was more marked after exercise. Sea duty group showed less increase in pulse rate at rest than the land duty group. Standing and resting pulse rate of sea duty group on lam was 81 and increased to 87 at the 5th day on board and remained smaller than the land duty group throughout the period on board. Control standing and resting pulse rate of land duty group on land was 76 and reached 89 at the 9th day on board and thereafter decreased a little. Pulse rate of land duty group at rest on board remained greater than that of sea duty group throughout the period on board. 3. Systolic blood pressure of sea duty group increased after boarding the ship and remained higher than the control value on land. In the land duty group, however, systolic blood pressure decreased during the period on board the ship. Diastolic blood pressure decreased in both groups. 4. Resting breathing rate of land duty group increased and remained higher than the control value on land. In sea duty group, however, resting breathing rate showed a transient increase on the 1st day on board and decreased thereafter to the control value on land and kept the same level throughout the period of cruise. Absolute value of breathing rate in the sea duty group was greater than the land duty group both at rest and after exercise. 5. There was a lowering of breathing efficiency in both groups. Thus, increases in tidal volume and minute ventilation volume and decreases in maximum breathing capacity, vital capacity, capacity ratio and air velocity Index were observed after boarding the ship. An increase in ventilation equivalent was also observed in both groups. The lowering of breathing efficiency was more marked in the land duty group than the sea duty group. 6. Energy expediture increased in both groups during their stay on the ship and was more marked in the sea duty group. 7, Lactate concentration in venous blood at rest and after exercise increased after boarding the ship and no group difference was observed.

  • PDF