• Title/Summary/Keyword: air quality evaluation

Search Result 607, Processing Time 0.027 seconds

Comparison of the Difference in Response Time According to the Server Configuration Type of the Indoor Air Quality Improvement System (실내공기질 개선 시스템의 서버 구성 방식에 따른 응답 시간의 차이 비교)

  • Joongjin Kook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.59-63
    • /
    • 2023
  • Various devices have been emerging as a means of measuring indoor air quality, and among them, there are devices that support real-time remote monitoring through IoT technology and a cloud environment. To improve indoor air quality, based on the results determined by measuring devices, air purifiers or ventilation systems may need to be operated, and temperature and humidity control may be required. In this paper, we propose a design of indoor air quality measuring devices required for indoor air quality evaluation, and of the system needed to control relevant devices to improve indoor air quality through the interaction with the measuring devices. Currently, the servers for the interaction of indoor air quality devices and IoT devices are divided into conventional server type and serverless type, comparing the differences in response time of IoT devices to changes of indoor air quality.

  • PDF

Verification of the Suitability of Fine Dust and Air Quality Management Systems Based on Artificial Intelligence Evaluation Models

  • Heungsup Sim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.8
    • /
    • pp.165-170
    • /
    • 2024
  • This study aims to verify the accuracy of the air quality management system in Yangju City using an artificial intelligence (AI) evaluation model. The consistency and reliability of fine dust data were assessed by comparing public data from the Ministry of Environment with data from Yangju City's air quality management system. To this end, we analyzed the completeness, uniqueness, validity, consistency, accuracy, and integrity of the data. Exploratory statistical analysis was employed to compare data consistency. The results of the AI-based data quality index evaluation revealed no statistically significant differences between the two datasets. Among AI-based algorithms, the random forest model demonstrated the highest predictive accuracy, with its performance evaluated through ROC curves and AUC. Notably, the random forest model was identified as a valuable tool for optimizing the air quality management system. This study confirms that the reliability and suitability of fine dust data can be effectively assessed using AI-based model performance evaluation, contributing to the advancement of air quality management strategies.

A Evaluation Study on Indoor Air Quality of the Apartment House through Field Measurement (현장실험을 통한 공동주택의 실내공기환경 평가)

  • Park, Yong-Seung;Bae, Sang-Hwan;Yoo, Bok-Hee;Hong, Cheon-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.83-87
    • /
    • 2003
  • In recent days, IAQ(Indoor Air Quality) is regarded as one of the most important environmental factors as well as thermal and acoustic comfort. Various architectural materials are applied and air-tightness of the building is more strengthening to save energy consumption. This is why the air quality of the newly built houses became worse. In this study, contaminants(CO, CO$_2$, Radon, TVOCs, HCHO) density was measured in a newly built house and evaluation was carried out by ASHRAE and EPA Standards. As a result, CO, CO$_2$, TSP and Radon density of the newly built house was in a range of ASHRAE and EPA Standards, but it turned out TVOCs and HCHO density exceeds almost 3${\sim}$5 times in comparison with that of ASHRAE and EPA Standards.

  • PDF

Development of Home Indoor Air Quality evaluation program considering planning and construction stage (주거 건물의 설계 및 시공단계를 고려한 실내공기질 평가 프로그램 개발에 관한 연구)

  • Choi, Dong-Hee;Kang, Dong-Hwa;Kim, Sun-Sook;Yeo, Myoung-Seok;Kim, Kwang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.51-56
    • /
    • 2005
  • The objective of this study is to develop Home Indoor Air Quality evaluation prorgram considering planning and construction stage for architects, engineers and occupants to estimate and improve the IAQ of a home. In this study, the IAQ modeling technique was discussed to determine the appropriate modeling of housing unit in Korea. The program algorithm was developed based on the selected model reflecting planning and construction stage. This program can be applied to estimate the IAQ of a home and encourage appropriate action in advance.

  • PDF

Air Quality Changes in a Museum Damaged by a Tsunami - Whale and Sea Museum, Iwate, Japan -

  • MATSUI, Toshiya;KAWASAKI, Emi;Huttmann, Imme
    • Journal of Conservation Science
    • /
    • v.35 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • This paper provides quantitative data that describes the evolution of the air quality in the Whale and Sea Museum, located in the Iwate prefecture, collected after the 2011 Great East Japan Earthquake and tsunami. The museum was damaged significantly by the disaster, and restoration works continued for over six years. The air quality in the temporary storage facility and museum was monitored during the rehabilitation process. Evaluation of air quality is carried out by gas chromatography- mass spectrometry, ion chromatography and high-performance liquid chromatography. The results showed that the characteristics of the chemical components differed depending on the measurement locations inside the building. The museum atmosphere tended to be alkaline as the airtightness increased because of the maintenance works at the entrance. It was also determined that it was necessary to study the intake/exhaust routes and to clean them according to the contamination degree. In Japan, there are recommended museum air quality standards for acetic acid, formic acid, alkali, and aldehydes. The results indicated that these standards should not be used as a reference for damaged museums. Furthermore, at the temporary storage facilities for to store the collections during the rehabilitation of the museum, solvents such as ethyl benzene, toluene, and xylene are initially abundant, although they can be reduced by ventilation, while other components such as 2E1H was confirmed in this case are likely to remain.

Beyond the Quality of Service: Exploring the Evaluation Criteria of Airlines

  • Wang, Ray
    • Industrial Engineering and Management Systems
    • /
    • v.13 no.2
    • /
    • pp.221-230
    • /
    • 2014
  • With the progress and prosperity of commerce and industry, time and money increasingly form an equal partnership. Using air carriers to shorten the round-trip time has become an important choice for many people in the tourism process. Faced with increasing competition within the aviation service environment, airline evaluation criteria and the requirements of customers are gradually dominating the evaluation mechanism for air transport service quality. Over the past few years, attention on the transport quality of service has been primarily focused more on land-based transport, and less on the relevant evaluation criteria of airlines. Many studies have shown that quality of service will directly affect customer satisfaction, resulting in the fact that good quality aviation services have become increasingly important. Therefore, in practical industrial operations with limited resources, there is an urgent need to delve into the assessment guidelines that have an impact on customers when they choose an airline, which can be used as a basis for improving customer satisfaction. Through a literature review and a reliability and validity analysis, this study summarized 19 evaluation criteria, using the purposive sampling method and the decision laboratory method (DEMATEL). In addition, this study viewed the causal relationship between the evaluation criteria and the degree of association as a continuing project for airlines. This study selected appropriate empirical samples from two domestic airlines. The conclusions may provide recommendations for all airlines.

Evaluation and Complement of the Representativeness of Air Quality Monitoring Stations Using Passive Air Samplers (수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방완에 대한 기초연구)

  • 우정현;김선태;김정욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.6
    • /
    • pp.415-426
    • /
    • 1997
  • Some arguments have been about over the representativeness of government-run air quality monitoring stations among scholars and non-governmental organizations (NGOs). However, it is not a simple problem to move monitoring stations because of continuity of data and high cost. So it is necessary to complement the monitoring data if it do not represent the ambient air quality properly. The purpose of this study was to evaluate the representativeness of some monitoring stations using passive $NO_2$ samplers and to find a complementary method from linear regression. Two stations were chosen for the evaluation: Shinlim Station was one of the most controversial stations in Seoul and Banpo Station had the best reputation. Air qualities were surveyed at seven points around each monitoring station with consideration of land use and distance. The ratios of the average $NO_2$ levels of the areas to these at the monitoring stations were 1.59 for Shinlim Station and 1.03 for Banpo Station. The differences between the average $NO_2$ levels and those at the monitoring stations were 10.75 ppb for Shilim Station and 0.34 ppb for Banpo Station. The correlation coefficients between the two levels were 0.7668 for Shinlim and 0.7662 for Banpo. The average coefficients of determination $(R^2)$ were 0.61 for Shinlim and 0.61 for Banpo. The Shinlim Station could not represent the air quality of Shinlim-Dong good because it is located in a green area at an outskirt of Shinlim-Dong. But the Banpo Station located in a central residential area of Banpo-Dong showed a fair representativeness. However, air quality turned out to be different with land use such as residential area, green area or road: the air quality data from a monitoring station located at a certain land use should not be interpreted as representing the air quality at any sites around the station. Equations to predict the average $NO_2$ levels of each area from the data from the monitoring stations were presented based on linear regression.

  • PDF

Evaluation of Indoor Environmental Factors in Office Building with Underfloor Air-Conditioning (UFAC) System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.36-45
    • /
    • 2001
  • During the last decade, an increasing interest in Underfloor Air-Conditioning (UFAC) systems has emerged. The purpose of this paper is to evaluate the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. The physical measurements and the Interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation (POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey .

  • PDF

Evaluation of Ventilation System Performance Using Indoor Air Quality Model (실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가)

  • 최성우
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

Evaluation of Pollutants Emissions according to the Selling Store in Department Store (백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가)

  • Wang, HyeongSeok;Hwang, JunSeok;Chang, SeongJin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.1
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).