• Title/Summary/Keyword: air protocol

Search Result 231, Processing Time 0.026 seconds

"Liability of Air Carriers for Injuries Resulting from International Aviation Terrorism" (국제항공(國際航空)테러리즘으로 인한 여객손해(旅客損害)에 대한 운송인(運送人)의 책임(責任))

  • Choi, Wan-Sik
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.1
    • /
    • pp.47-85
    • /
    • 1989
  • The Fundamental purpose of the Warsaw Convention was to establish uniform rules applicable to international air transportation. The emphasis on the benefits of uniformity was considered important in the beginning and continues to be important to the present. If the desire for uniformity is indeed the mortar which holds the Warsaw system together then it should be possible to agree on a worldwide liability limit. This liability limit would not be so unreasonable, that it would be impossible for nations to adhere to it. It would preclude any national supplemental compensation plan or Montreal Agreement type of requirement in any jurisdiction. The differentiation of liability limits by national requirement seems to be what is occurring. There is a plethora of mandated limits and Montreal Agreement type 'voluntary' limits. It is becoming difficult to find more than a few major States where an unmodified Warsaw Convention or Hague Protocol limitation is still in effect. If this is the real world in the 1980's, then let the treaty so reflect it. Upon reviewing the Warsaw Convention, its history and the several attempts to amend it, strengths become apparent. Hijackings of international flights have given rise to a number of lawsuits by passengers to recover damages for injuries suffered. This comment is concerned with the liability of an airline for injuries to its passengers resulting from aviation terrorism. In addition, analysis is focused on current airline security measures, particularly the pre-boarding screening system, and the duty of air carriers to prevent weapons from penetrating that system. An airline has a duty to exercise a high degree of care to protect its passengers from the threat of aviation terrorism. This duty would seemingly require the airline to exercise a high degree of care to prevent any passenger from smuggling a weapon or explosive device aboard its aircraft. In the case an unarmed hijacker who boards having no instrument in his possession with which to promote the hoax, a plaintiff-passenger would be hard-pressed to show that the airline was negligent in screening the hijacker prior to boarding. In light of the airline's duty to exercise a high degree of care to provide for the safety of all the passengers on board, an acquiescene to a hijacker's demands on the part of the air carrier could constitute a breach of duty only when it is clearly shown that the carrier's employees knew or plainly should have known that the hijacker was unarmed. A finding of willful misconduct on the part of an air carrier, which is a prerequisite to imposing unlimited liability, remains a question to be determined by a jury using the definition or standard of willful misconduct prevailing in the jurisdiction of the forum court. Through the willful misconduct provision of the Warsaw Convention, air carrier face the possibility of unlimited liability for failure to implement proper preventive precautions against terrorist. Courts, therefore, should broadly construe the willful misconduct provision of the Warsaw Convention in order to find unlimited liability for passenger injuries whenever air carrier security precautions are lacking. In this way, the courts can help ensure air carrier safety and prevention against terrorist attack. Air carriers, therefore, would have an incentive to increase, impose and maintain security precautions designed to thwart such potential terrorist attacks as in the case of Korean Air Lines Flight No.858 incident having a tremendous impact on the civil aviation community. The crash of a commercial airliner, with the attending tragic loss of life and massive destruction of property, always gives rise to shock and indignation. The general opinion is that the legal system could be sufficient, provided that the political will is there to use and apply it effectively. All agreed that the main responsibility for security has to be borne by the governments. I would like to remind all passengers that every discovery of the human spirit may be used for opposite ends; thus, aircraft can be used for air travel but also as targets of terrorism. A state that supports aviation terrorism is responsible for violation of International Aviation Law. Generally speaking, terrorism is a violation of international law. It violates the soverign rights of the states, and the human rights of the individuals. I think that aviation terrorism as becoming an ever more serious issue, has to be solved by internationally agreed and closely co-ordinated measures. We have to contribute more to the creation of a general consensus amongst all states about the need to combat the threat of aviation terrorism.

  • PDF

Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams (고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발)

  • Shin Dong Oh;Park Sung Yong;Ji Young Hoon;Lee Chang Geon;Suh Tae Suk;Kwon Soo IL;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.381-390
    • /
    • 2002
  • Purpose : To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for the IAEA TRS-398 and the AAPM TG-51, based on the absorbed dose to water calibration factor, so as to avoid the unwanted error associated with these calculation procedures. Materials and Methods : Currently, the most widely used dosimetry Protocols of high energy photon beams are the air kerma calibration factor based on the IAEA TRS-277 and the AAPM TG-21. However, this has somewhat complex formalism and limitations for the improvement of the accuracy due to uncertainties of the physical quantities. Recently, the IAEA and the AAPM published the absorbed dose to water calibration factor based, on the IAEA TRS-398 and the AAPM TG-51. The formalism and physical parameters were strictly applied to these four dose calibration programs. The tables and graphs of physical data and the information for ion chambers were numericalized for their incorporation into a database. These programs were developed user to be friendly, with the Visual $C^{++}$ language for their ease of use in a Windows environment according to the recommendation of each protocols. Results : The dose calibration programs for the high energy photon beams, developed for the four protocols, allow the input of informations about a dosimetry system, the characteristics of the beam quality, the measurement conditions and dosimetry results, to enable the minimization of any inter-user variations and errors, during the calculation procedure. Also, it was possible to compare the absorbed dose to water data of the four different protocols at a single reference points. Conclusion : Since this program expressed information in numerical and data-based forms for the physical parameter tables, graphs and of the ion chambers, the error associated with the procedures and different user could be solved. It was possible to analyze and compare the major difference for each dosimetry protocol, since the program was designed to be user friendly and to accurately calculate the correction factors and absorbed dose. It is expected that accurate dose calculations in high energy photon beams can be made by the users for selecting and performing the appropriate dosimetry protocol.

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

Development of Web-based Dosimetry Calibration Program for High Energy Radiation (웹 기반 고 에너지 방사선에 대한 흡수선량 교정 프로그램 개발)

  • Shin Dong Oh;Shin Dong Ho;Kim Sung Hoon;Park Sung Yong;Seo Won Seop;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.116-124
    • /
    • 2005
  • Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma calibration factors, have somewhat complex formalism and limitations for improving dosimetric accuracy due to uncertainty of the physical parameters used. Recently the IAEA and the AAPM published the absorbed dose to water-based dosimetry protocol. In this work web-based dose calibration program for IAEA TRS-398 and AAPM TG-51 protocols were developed. This program developed using the Visual C$\#$ language can be used in the internet. User selectable dosimetry protocol on the web allows the absorbed dose to water data of the two protocols at a reference point to be easily compared, and enables to conveniently manage and understand the current status of the dosimetry calibration performed at participating institutions in korea. This program and the resultant database from the web-based calibration can be useful in developing new dosimetry protocols in Korea.

  • PDF

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

Analysis Study of Seasonal Performance Factor for Residential Building Integrated Heat Pump System (주거용 건물에서의 히트펌프 시스템 연성능 평가에 관한 연구)

  • Kang, Eun-Chul;Min, Kyoung-Chon;Lee, Kwang-Seob;Lee, Euy-Joon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 2016
  • Heat pump unit performance is represented by the COP(Coefficient of Performance) and expressed by the one point design condition according to KS C 9306. However, when heat pump operated to the real buildings, the simulations are changed continuously according to the actual weather conditions, the building load and heat pump source conditions. The purpose of this paper is to evaluate the APF(Annual performance factor) for a climate dependent building integrated air-to-air heat pump system in major cities in Korea. TRNSYS simulation tool with an international MV standard based IPMVP 4.4.2 was utilized to perform the annual performance analysis. The APF with the multi-performance data based method was calculated as 2.29 for Daejeon residential building case while Busan residential building case appeared as the highest with 2.36.

Dynamic Channel-Time Assignments based on the link status in IEEE 802.15.3 High-rate WPAN (IEEE 802.15.3 고속 무선 PAN(Personal Area Network)에서 링크상태에 따른 동적 채널할당)

  • 곽동원;이승형
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.844-851
    • /
    • 2004
  • Various types of error are caused due to many factors of various environment in air interface channel of wireless communications. In this case, the reliability of the channel is much lower than that of wired case. IEEE 802.15.3 high-rate WPAN, which operates in an ad hoc networking environment, is more susceptible to such errors. The problem has been investigated for wireless LANs, for example, as follows. If the queue size of a certain node is longer than that of other nodes, the node estimates that its channel state is bad and the resource of the node is decreased. However this method has a disadvantage that a central controller must always monitor the status. To avoid this disadvantage, in this paper, a new MAC protocol that the throughput of overall piconet is increased by LDS (Link-status Dependent Scheduling) is proposed.

Selective Oxidation of Amines to Imines or Nitriles by Manganese Dioxide in Air (공기 중에서 망간 다이옥사이드에 의한 아민에서 이민 또는 나이트릴로의 선택적 산화 반응)

  • Kim, Yo Han;Hwang, Seung Kyu;Lee, Yoon Sik;Kim, Jung Won
    • Applied Chemistry for Engineering
    • /
    • v.25 no.2
    • /
    • pp.215-221
    • /
    • 2014
  • A simple heterogeneous system has been developed by using base treated manganese dioxide (B-$MnO_2$) for the aerobic oxidation of amines under mild reaction conditions of 1 atm of air and $50^{\circ}C$ in hexane. This system was highly efficient to oxidize various kinds of primary or secondary amines including aliphatic, aromatic, and hetero-atomic ones under the applied reaction conditions. Amines were oxidized to nitriles or diimines by the self-condensation or oxidative dehydrogenation through imine intermediate. The B-$MnO_2$ was reused for at least 5 times without any loss of its catalytic performance and showed its cost effectiveness, easy workup, and easy separation of the products for achieving the protocol of green chemistry.

Developing Liquid Cooling Garments to Alleviate Heat Strain of Workers in Summer and Exploring Effective Cooling Temperature and Body Regions (여름철 작업자들의 고체온증 예방을 위한 액체냉각복 개발 및 효과적인 냉각온도와 인체 냉각부위 탐색)

  • Jung, Jae-Yeon;Kang, Juho;Seol, Seonhong;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.22 no.2
    • /
    • pp.250-260
    • /
    • 2020
  • The purpose of the present study was to explore the most effective body region and cooling temperature to alleviate heat strain of workers in hot environments. We developed liquid cooling hood, vest, sleeves and socks and applied the water temperatures of 10, 15, 20, and 25℃ through the liquid cooling garments in a hot and humid environment (33℃ air temperature and 70% RH air humidity). A healthy young male participated in a total of 16 experimental trials (four cooling garments × four cooling temperatures) with the following protocol: 10-min rest, 40-min exercise on a treadmill and 10-min recovery. The results showed that rectal temperature, mean skin temperature, and ratings of perceived exertion during exercise; heart rate and diastolic blood pressure during recovery; and total sweat rate were lower for the vest condition than other garment conditions(p < .05). However, there was no differences in mean skin temperature among the four cooling garments when we compared the values converted by covering area(%BSA). When we classified the results by cooling temperature, there were no consistent differences in thermoregulatory and cardiovascular responses among the four temperatures, but 25℃ water temperature was evaluated as being the most ineffective cooling temperature in terms of subjective responses. In conclusion, the results indicated that wearing cooling vest with < 20℃ cooling temperature can alleviate heat strain of workers in hot and humid environments. If the peripheral body regions are cooled with liquid cooling garments, larger cooling area with lower cooling temperature than 10℃ would be effective to reduce heat strain of workers. Further studies with a vaild number of subjects are required.

A studies on the Air pollutant Emission Rate calculation from vessels in the Ulsan Port (울산항 선박으로부터의 대기오염 배출량 산정에 관한 연구)

  • Cheong Kwng-Hyun;Kim Sung-Joo;Park Hung-Suck
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.05a
    • /
    • pp.111-118
    • /
    • 2005
  • The Protocol adopted in Sep. 1997 included the new Annex VI of MARPOL 73/78, which will enter into force on 19 May 2005. MARPOL Annex VI sets limits on sulphur oxide and nitrogen oxide emissions from ship exhausts and prohibits deliberate emissions of volatile organic compound (VOCs) from oil tanker in port and oil terminal. This study was conducted to find out countermeasures for the new Annex VI of MARPOL 73/78 and draw up a feasible management plan. The emission quantity of NOx and SOX from ships in Ulsan Port was calculated by U.S. EPA and Japan Marine Engineering emission factors of air pollutant from ship exhausts. In addition, volatile organic compound (VOCs) from oil tanker during the loading and discharging period, also calculated.

  • PDF