• Title/Summary/Keyword: air pollution prevention device

Search Result 5, Processing Time 0.016 seconds

A Study on the Removal of Air Pollutants Using Oxidants and Microbubbles (산화제와 마이크로버블을 이용한 대기오염물질 제거)

  • Kyung-bo Ku;Hyuk-Ku Kwon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.3
    • /
    • pp.93-102
    • /
    • 2023
  • This study investigated the possibility of treating heavy metal pollutants existing in the air in addition to simultaneously removing NOx and SOx by injecting oxidizing and reducing agents into a scrubber into a microbubble device to create an eco-friendly method that does not generate secondary pollutants. Lead compound (Pb) was selected as the heavy metal substance in the air to be treated with microbubbles, and the removal efficiency was confirmed. By treating microbubbles by connecting them to a scrubber, it was confirmed that not only NOx and SOx but also heavy metal substances in the air were reduced, cost was reduced, and secondary environmental pollutants were not generated. Through this study, it was possible to simultaneously remove NOx, SOx, and heavy metals at low cost by applying an eco-friendly method, rather than the existing high-cost treatment method such as SCR. If oxidizing agent, reducing agent, and microbubbles are used appropriately, economical and efficient air pollution can be achieved. Since material processing was possible, it is expected to be helpful in the technological development of environmental prevention facilities.

Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants (섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성)

  • Jin Ho Jung;Seung Hwan Ryu;Soon Duk Kwon;Yoon Hyun Cho
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

Organic Solvent Exposure of Thinner-Using Occupation and Its Treatment by Means of $TiO_2$ Photocatalyst (신너사용 작업장의 유기용제 노출 및 $TiO_2$ 광촉매를 이용한 BTX처리에 관한 연구)

  • 양원호;김현용;손부순;박종안
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.26-33
    • /
    • 2002
  • Ultimate objective of industrial hygiene is the prevention of health impairment that may result from exposure to chemicals at workplace. Workers in solvent thinner-using occupation environment may be highly exposed to VOCs (volatile organic compounds) because solvent thinner has been used extensively such as painting, spraying, degreasing, coating and so on in Korea. The purpose of this study was to recognize, evaluate, and propose the control methods of VOCs from solvent thinner-using workplace. Five target volatile organic compounds (benzene, toluene, ethylbenzene, o-xylene, and m-xylene) were monitored in H company of Shiwa Industrial Complex and analyzed in perosnal, occupational indoor and outdoor during working hours simultaneously. Engineering control such as local ventilation should be made in considering the long-term exposure, though measured VOCs concentration did not exceed the workplace exposure standards. In addition, air cleaning device should be installed in local ventilation because Shiwa Industrial Complex has had the serious ambient air pollution. Currently, environmental purification using $TiO_2$ photocatalyst have attracted a great deal of attention with increasing number of recent environmental problems. In this study, $TiO_2$ sol coated on the ceramic bead was prepared by sol-gel method and the photodegradation of target compounds was investigated in gas phase by the exposure to UV-A lamp(365nm) in a batch system.

Emission Characteristics of Fine Particles, Vanadium and Nickel from Heavy Oil Combustion (중유 연소 시 발생하는 미세입자 및 니켈과 바나듐의 대기 중 배출특성)

  • Jang, Ha-Na;Kim, Sung-Heon;Lee, Ju-Hyung;Hwang, Kyu-Won;Yoo, Jong-Ik;Sok, Chong-Hui;Seo, Yong-Chil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.353-360
    • /
    • 2006
  • This study identified a particle size distribution (PSD) of fine particulate matter and emission characteristics of V and Ni by the comparison between anthropogenic sources of oil combustion (industrial boiler, oil power plant, etc.) and lab-scale combustion using a drop-tube furnace. In oil combustion source, the mass fraction of fine particles (less than 2.5 micrometers in diameter) was higher than that of coarse particles (larger than 2.5 micrometers in diameter) in $PM_{10}$ (less than 10 micrometers in diameter) as like in lab-scale oil combustion. In addition to this, it was identified that ultra-fine particles (less than 0.1 micrometers in diameter) had a large distribution in fine particles. Toxic metals like V and Ni had large mass fractions in fine particles, and most of all was distributed in ultra-fine particles. Most of ultra-fine particles containing toxic metals have been emitted into ambient by combustion source because it is hard to control by the existing air pollution control device. Hence, we must be careful on these pollutants because it is obvious that these are associated with adverse health and environmental effect.

Recycling Improvement Plans through Analysis of the Present Status of Used oil (폐유 현황 분석 및 재활용 증진 방안)

  • Lee, Hi Sun
    • Journal of Environmental Policy
    • /
    • v.14 no.2
    • /
    • pp.133-148
    • /
    • 2015
  • The number of used oil refining companies has been increased and it causes shortage of the volume of used oil per recycling company. In addition, the number of used oil collecting companies has been increased and it caused excessive competition among companies with excessive costs. Companies use not only proper used oil but also low quality used oil because of shortage of supply. It is the reason of environmental pollution. Also excessive competition brings high cost of refined oil and it becomes a burden on the consumer. Therefore, the recycling improvement plans of used oil is needed because of these causes. First of all, importing used oil from the developed countries of OECD is the one of solution to secure a used oil supply. However, imported used oil should meet the international quality standards and it is examined twice by international authority institute such as K-petro in both exporting and importing countries. Second, the cost would be reduced with the relaxation on regulations of used oil refinement. However, regulation to sediment and water should be separated. Sediment should be kept within 2% and water should be kept within 5%. It is the way to relax the regulations of used oil refinement with preventing environmental pollutions. Finally, the standard of used oil for heater should be regulated strictly. To prevent pollutions, used oil for heater is limited to high quality waste lubricating oil. Also the air pollution prevention device has to be installed on heater.

  • PDF