• Title/Summary/Keyword: air pollution control

Search Result 523, Processing Time 0.025 seconds

A Tunnel Ventilation Control Algorithm by Using CO Density Prediction Algorithm (일산화탄소 농도 예측 기능을 사용한 터널 환기 제어 알고리즘)

  • Han Doyoung;Yoon Jinwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1035-1043
    • /
    • 2004
  • For a long road tunnel, a tunnel ventilation system may be used in order to reduce the pollution level below the required level. To control the tunnel pollution level, a closed loop control algorithm may be used. The feedforward prediction algorithm and the cascade control algorithm were developed to regulate the CO level in a tunnel. The feedforward prediction algorithm composed of the traffic estimation algorithm and the CO density prediction algorithm, and the cascade control algorithm composed of the jet fan control algorithm and the air velocity setpoint algorithm. The verification of control algorithms was carried out by dynamic models developed from the actual tunnel data. The simulation results showed that control algorithms developed for this study were effective for the control of the tunnel ventilation system.

Research of Efficient Environmental Policy Instruments for the Reduction of SO2-Emissions from Stationary Sources (고정오염원에서 발생하는 SO2 배출량 저감을 위한 효율적인 환경정책수단의 연구)

  • Lee, Yeong Jun
    • Journal of Environmental Science International
    • /
    • v.13 no.4
    • /
    • pp.339-347
    • /
    • 2004
  • This paper asks the question: what choice of environmental policy instruments is efficient to reduce sulfur dioxide from stationary sources\ulcorner: In Korea, command and control has been a common way of controlling $SO_2-emissions.$ When compared to the non-incentive environmental policy instrument such as command and control, economic incentive environmental policy instrument has been the advantage of making polluter himself flexibly deals with in marginal abatement cost to develop environmental technology in the long view. Therefore, the application possibility of the incentive environmental policy instrument was studied in this research to realize the countermeasure for controlling of $SO_2-emissions.$ As a result, enforcement of the countermeasure such as flue gas desulfurizer by command and control would be suitable because power generation is performed by the public or for the public in source of air pollution and thus, economic principle is not applied to the polluter. In the source of industrial pollution, enforcement of fuel tax is found to be suitable for the countermeasure for the use of low sulfur oil in terms of the flexibility of demand for the price in the long tenn. For the permissible air pollution standards applicable to all air pollutant emitting facilities, enforcement of incentive environmental policy such as bubble, off-set, banking policy or tradeable emission penn its would be ideal in long terms according to the regional characteristics and the number and scale of air pollutant emitting facilities.

Determinants of Heath : Environmental Factors (국민 건강의 결정 요인 2 : 환경요인)

  • Lim, Hyun-Sul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.4 s.44
    • /
    • pp.480-507
    • /
    • 1993
  • Environmental pollution is common problem of the present world that is intimately related to the future survival of human beings. The problems of environmental pollution originate from the pursuit of benefit by enterprises, insufficient countermeasure of government and ignorant life style of the people. Health hazards due to environmental pollution have characteristics of irreversibility, difficulty in measurement and ineffectiveness of personal prevention. Objects of this article are to review the various aspects of environmental pollution, to outline the present status of environmental pollution and strategy to control environmental pollution in Korea. In the first part of this article, causes of environmental pollution are presented. International relationships, world-wide status of environmental pollution and health hazards due to environmental pollution are briefly reviewed. In the second part, present status of air, water, soil and ocean pollution in Korea is presented. Pollution by radioactive materials, noise, vibrations, odor, wastes and chemicals is reviewed. Climate changes related to environmental poisoning, problems of workplace environment, pesticide and defoliants are also reviewed. Finally, control measures for environmental pollution including the role of government are reviewed.

  • PDF

The Characterization of Incomplete Combustion Products in Open Burning (노천소각에서 배출되는 불완전연소생성물 특성 연구)

  • Jung, No-El;Heo, Sun-Hwa;Jo, Myeong-Ran;Kim, Hyung-Chun;Jang, Se-Kyung;Hong, Ji-Hyung;Dong, Jong-In;Lee, Sang-Bo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.1
    • /
    • pp.48-58
    • /
    • 2014
  • It is very important to investigate air pollutants emissions emitted from open burning in order to control nonpoint sources effectively. In this study, we utilized incineration simulator proposed by U.S EPA and investigated emissions of CO, OC/EC, from household waste and biomass burning to estimate pollutant emissions by illegal incineration of biomass wastes. Emission factor of OC was estimated as 17.1 g/kg for rice strew, 23.5 g/kg for barley, 10.3 g/kg for corn stover, 4.3 g/kg for unseasoned wood, respectively. In case of EC, it was calculated as 1.6 g/kg for rice strew, 4.3 g/kg for barley, 1.4 g/kg for corn stover, 0.6 g/kg for unseasoned wood, respectively. Most of the pollutants emissions were emitted at the stage 1 and 2. In the stage 3, the pollutants concentration decreased gradually. To estimate emissions and build inventory for biomass burning, we need to know accurate activity data. We, therefore, used activity data of both survey results of previous study and statistical data of National Statistical Office. However, we need to perform additional experiments in the future to obtain more accurate activity data for various cases.

Measurement of Indoor Air Quality in a Kindergarten (유치원내 실내공기환경 측정)

  • Kim, Yun-Deok;Lim, Soo-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.1
    • /
    • pp.52-57
    • /
    • 2007
  • Kindergarten children are engaged in the age of physical immaturity as well as the rapid growth. The indoor air contaminants that are proved to affect even the full grown adults are obvious to have no little influence to immature small children in a growth period. In May 2004, for the multi purpose facilities and newly constructed apartments, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. In Dec 2005, the law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. However, since the kindergarten takes none of the classifications, even the current condition is not grasped although it is directly connected to the health of growing children. Therefore, the study aims to analyze indoor air pollution of one selected kindergarten in Incheon city.

Research Method and Prediction Model of PM2.5 in Cities

  • Yang, ZhenYu;Xia, Sai;Jin, Jie
    • Journal of Urban Science
    • /
    • v.8 no.2
    • /
    • pp.25-28
    • /
    • 2019
  • Hefei has suffered from heavy air pollution, especially car exhaust and industry emissions. The smoke contains PM2.5 and PM10. These smoke will enter people's bodies and have a bad impact on the human body. This review is about PM2.5. This review covers the sources and hazards of PM2.5. It introduces the use of modelling methods to analyze PM2.5 pollution in various places and proposes treatment measures. These cities were heavily polluted by PM2.5, and after the local government's management and renovation, there has been a significant improvement. However, there are still many shortcomings in the process of pollution improvement. This review combines the means used in the process of pollution prevention and control in Handan City, Beijing. Hefei now suffers from some of the same pollution as these cities did in the past.

A Study on the Comparison of Emission Factor Method and CEMS (Continuous Emission Monitoring System) (배출계수법과 연속자동측정법에 의한 배출량 비교 연구)

  • Jang, Kee-Won;Lee, Ju-Hyoung;Jung, Sung-Woon;Kang, Kyoung-Hee;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.410-419
    • /
    • 2009
  • Generally, air pollutant emission at workplace is estimated by two methods: indirect methods using emission factors and direct methods based on CEMS (Continuous Emission Monitoring System). CAPSS (Clean Air Policy Support System) is a representative indirect method and the national air pollutant database of Korea. However, characteristics of some workplaces may create a gap between CAPSS and CEMS data. For improving of emission data accuracy, emission data of CEMS (named CleanSYS) equipped at 138 target workplaces were compared with those of CAPSS. As a result, $SO_x$ and $PM_{10}$ emission levels obtained by CAPSS were lower than those of CleanSYS. $SO_x$ and $PM_{10}$emission ratios were 61.5% and 71.2% lower respectively, showing the biggest gaps. On the other hand, $NO_x$ emission of CAPSS was higher by 10.4%. $SO_x$ showed the biggest difference in 'Energy industry combustion' and $NO_x$ did in 'Production Process' within the SCC category. $PM_{10}$ presented a large gap in 'Manufacturing industry combustion.' The differences in $SO_x$ between the two systems occurred because some large-size facilities lack pollution controllers or efficient pollution controllers. Based on this study, CAPSS emission database of Korea will improve accuracy through adopting CEMS emission system, which enables more efficient national atmospheric policies and workplace management.

Emission Control Routes in Container Shipping between Korea-China

  • Je-Ho Hwang;Si-Hyun Kim
    • Journal of Korea Trade
    • /
    • v.27 no.3
    • /
    • pp.119-146
    • /
    • 2023
  • Purpose - As the severity of air pollution caused by the shipping industry is becoming evident, port authorities have started making efforts to reduce air pollutants. Considering the limitations of the currently implemented emission-control area (ECA) and vessel-speed reduction program (VSRP), which are narrow in the designation range and navigation behavior of ships, this study proposes an emission-control route (ECR) that can complement the aforementioned two environmental policies. Design/methodology - This study was conducted on Korea-China trade service routes (ports of call) of regular liners. This study employed vessel-specific data, which is from an automatic identification system (AIS), for 1,728 maritime transportations performed by 387 container vessels during one year (July 1, 2021, to June 30, 2022). Performing a scenario analysis, this study analyzed the effectiveness of reduced air-pollutant emissions. Findings - This study found that the implementation of ECRs could increase average voyage time by 12.38%-25.28% but reduced air-pollutant emissions by 29.02%-43.54%. Additionally, the increase in average voyage times reduces the anchorage time of ships outside ports, providing an incentive for ship operators to voluntarily participate in compliance with regulations, thereby contributing to the establishment of a virtuous cycle of air-environmental policies related to ships. Originality/value - This study aims to verify the policy effectiveness by designing an ECR scope for liner trade routes between Korea and China. Therefore, originality and the value of this study includes conceptualizing the ECR system, analyzing its environmental performance, and exploring new policies that can be implemented while complementing existing policies.

Comparison of Air Pollution Characteristics in the Center Lane-Bus Stop and the Surrounding Areas (중앙차선 버스 정류장과 주변지역의 대기오염 특성 비교)

  • Lee, Yong-Ki;Kim, Woong-Soo;Hong, Soon-Mo;Shin, Eun-Sang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.378-386
    • /
    • 2014
  • The use of bus stop in the center lane has reduced the emissions of exhaust gas on the road due to the improvement of the traffic speed but has caused a health problem for the citizens who are waiting for the bus in the platform, and thus the air pollution control of bus stop in the center lane is emerging as a more important part. This study was conducted to investigate the air pollution degree for the center lane-bus stops in four regions using mobile air measuring vehicle, and to evaluate the characteristics of air pollution by comparing with the data measured at the urban air monitoring site close to the bus stops. In addition, the correlation analysis was performed to analyze the impact to neighboring region by vehicle exhaust gas. The regional mean concentration of nitrogen dioxide in the center lane-bus stops ranged from 0.025 to 0.043 ppm which shows from 2.5 times to 5.3 times higher than the values of urban air monitoring site selected as a control group. The regional mean concentration of ozone in the center lane-bus stops ranged from 0.023 to 0.034 ppm which shows from 3% to 28% lower than the values of urban air monitoring site selected as a control group. The concentrations of nitrogen dioxide and ozone for the sampling regions did not exceed one hour-air quality environmental standard (0.1 ppm). The mean concentration of particulate matter for four center lane-bus stops was $28{\mu}g/m^3$ which shows about 27% higher than the values of urban air monitoring site selected as a control group, and that of particulate matter did not exceed one day-air quality environmental standard ($100{\mu}g/m^3$). In the results of correlation analysis between data from center lane-bus stops and data from urban air monitoring sites, the correlation coefficient (r) of nitrogen dioxide was relatively low as 0.316 to 0.416, and the correlation coefficient was high as the distance was close and vice versa. However, the correlation coefficient of ozone ranged from 0.167 to 0.658 and the correlation coefficient was high as the distance was far and vice versa.