• Title/Summary/Keyword: air flow

Search Result 6,984, Processing Time 0.036 seconds

Numerical Simulation of Effects of Atmospheric Flow Fields Using SurFace Observational Data on Dispersion Fields of Air Pollutants in Gwangyang Bay (광양만권역에서의 자료동화된 대기 유동장이 대기 오염 물질의 확산장에 미치는 영향에 관한 수치모의)

  • Lee Hwa Woon;Won Hye Young;Choi Hyun-Jung;Kim Hyun Goo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.169-178
    • /
    • 2005
  • A critical component of air pollution modeling is the representation of atmospheric flow fields within a model domain, since an accurate air quality simulation requires an accurate portrayal of the three-dimensional wind fields. The present study investigated data assimilation using surface observational data in the complex coastal regions to simulate a realistic atmospheric flow fields. Surface observational data were categorized into three groups (Near coastal region, Far coastal region 1, Far costal region 2) by the locations where the sites are. Experiments were designed according to the location of observational stations and MM5/CALPUFF was used. The results of numerical simulation of atmospheric flow fields are used as input data for CALPUFF which predicts dispersion fields of air pollutants. The result of this study indicated that data assimilation using data in the far coastal region 2 provided an attractive method for generating realistic meteorological fields and dispersion fields of air pollutants in Gwangyang area because data in the near coastal region are variable and narrow representation.

Study on the Flow Characteristics of Supersonic Air Intake at Mach 4 (마하4 초음속 공기 흡입구 유동 특성에 관한 연구)

  • ;;;;Shigeru , Aso
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.10
    • /
    • pp.61-70
    • /
    • 2006
  • A Supersonic air intake model was designed for the high performance ramjet and dual-mode scramjet engine to operate at Mach 4 flight condition. The air intake was tested in the blowdown-type wind tunnel of Kyushu University to identify the internal flow characteristics corresponding to the flight parameters such as the back pressure, angle of attack and angle of yaw. Flow visualization was achieved by the Schlieren and oil flow visualization techniques. The intake performance was analyzed quantitatively based on the surface pressure and total Pressure measurements. The experimental results were compared with the computational fluid dynamics results. The present study exhibits the fundamental but rarely found experimental results of the high Mach number supersonic air intake.

The Effect of Cross-flow on Liquid Atomization (횡단유동이 액체 미립화에 미치는 영향)

  • Kim, Jong-Hyun;Cho, Woo-Jin;Lee, In-Chul;Lee, Bong-Soo;Koo, Ja-Ye
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.87-92
    • /
    • 2008
  • The breakup processes and spray plume characteristics of liquid jets injected in subsonic air cross-flows were experimentally studied. The behaviors of column, penetration, breakup of plain liquid jet and droplet sizes, velocities have been studied in non-swirling cross-flow of air. Nozzle has a 1.0 mm diameter and Lid ratio=5. Experimental results indicate that the breakup point is delayed by increasing air momentum, the penetration decreases by increasing Weber number and the split angle is increased by increasing air velocity or decreasing injection velocity. SMD increases according as increasing height or decreases in accordance with increasing air velocity. This phenomenon is related to the momentum exchange between column waves and cross-flow stream. Droplet vector velocities were varied from 11.5 to 33 m/s. A higher-velocity region can be identified in down edge region at Z/d=40, 70 and 100. Lower-velocity region were observed on bottom position of the spray plume.

A Study on The Counter-Flow Cooling Tower Performance Anaysis and Experiments

  • Seo, Moo-Gyo;Kim, Young-Soo;Kim, Eun-Pil;Yoon, Jung-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.50-57
    • /
    • 2001
  • The thermal performance of cooling towers is affected by the temperature of inlet water, wet bulb temperature of entering air and water-air flow rate. In this stud${\gamma}$, the effects of these variables are simulated using NTU-method and experimentally investigated for the counter-flow cooling towers. The simulation program to evaluate these variables which affect the performance of cooling tower was developed. The maximum errors between the results of simulations and experiments were 3.8% under the standard design conditions and 5.4% under the other conditions. The performance was increased up to 46~50% as the water loading was increased from 6.8$m^3/hr{\cdot}m^2$ to 159$m^3/hr{\cdot}m^2$. The range was reduced up to 56~42% when the wet bulb temperature of the entering air was increased from 22${\circ}C$ to 29${\circ}C$.

  • PDF

Internal Flow Characteristics for Tangential Entry Conditions in a Swirl Injector (스월 인젝터에서 접선방향 유입구 조건에 따른 내부유동의 특성 연구)

  • Kim, Sung-Hyuk;Khil, Tae-Ock;Cho, Seong-Ho;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.115-118
    • /
    • 2008
  • Many theoretical and experimental studies have been conducted to investigate elements of the hydrodynamic process, such as variations in liquid film thickness or air core diameter. From these studies, some theoretical relationships have been established through an approximated analytical solution of flow hydrodynamics in a swirl nozzle. However, experimental studies on elements such as internal flow have not produced conclusive results. In this study, the variations and stability of the internal flow were examined by visualizing the air core and measuring the liquid film thickness.

  • PDF

An Investigation of Environmental Performance on Shaft Box Type Balcony Adopted to Apartment Building (공동주택에 적용된 Shaft Box형 발코니의 환경성능 검토)

  • Roh, Ji Woong
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.27-32
    • /
    • 2013
  • This study focus on shaft box facade, special form of box window construction. It consists of a system of box window with continuous vertical shafts that extend over a number of stories to create a stack effect. The subject building was decided by analyzing various types of exiting apartments. Shaft box type balcony was devised by setting up shaft space at a part of balcony. Air flow and indoor air temperature were simulated, performance of shaft box type balcony was compared with existing types using VE computer simulation program. Research consequence can be summarized as follow: 1) In the case of existing types, the change of window opening rate has only a little effect on the improvement of indoor temperature. But, air flow rate increased two times in the case that changed opening rate 20% to 40% 2) In the case of existing types, the growth of air flow rate has little effect on the improvement of indoor temperature. But, shaft box type represented the remarkable effect on the improvement of indoor temperature as well as the growth of air flow rate.

Internal Flow Stability for Tangential Entry Conditions in a Swirl Injector (스월 인젝터에서 접선방향 유입구 조건이 내부유동의 안정성에 미치는 영향에 대한 연구)

  • Kim, Sung-Hyuk;Khil, Tae-Ock;Cho, Seong-Ho;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.6
    • /
    • pp.30-37
    • /
    • 2008
  • Many theoretical and experimental studies have been conducted to investigate elements of swirl injector hydrodynamics, such as variations in liquid film thickness or air core diameter. From these studies, some theoretical relationships have been established through an approximate analytical solution of flow hydrodynamics in a swirl nozzle. However, experimental studies on elements such as the stability of internal flow have not produced conclusive results. In this study, the stability of the internal flow under tangential entry conditions was examined by visualizing the formation of the air core in the swirl chamber and measuring the liquid film thickness in the orifice.

Atomization of Liquid Via a Combined System of Air Pressure and Electric Field (공기 압력과 전기장이 접목된 액적 분무에 관한 연구)

  • Hwang, Sangyeon;Seong, Baekhoon;Byun, Doyoung
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.2
    • /
    • pp.9-12
    • /
    • 2014
  • Conventional electrospray and air spray methods have the vulnerabilities of limited flow rate (throughput) and droplet size, respectively. Since high throughput with uniform size of droplet is required for various applications, an improved technique should be adopted. Here, we report a combined system of an air pressure and an electric field and evaluate the atomization performance of it. The air flow allowed applying high flow rate range and the electric field reinforced the atomization process to generate fine droplets. A correlation between two forces was investigated by comparing the droplet produced by each method. The atomized droplets were measured and visualized by image processing and a particle image velocimetry (PIV). The quantitative results were achieved from the parametric space and the effect of both forces was analyzed. The motion of charged droplets followed the outer electric field rather than the complex vortex in the shear layer so that the droplets accelerated directly toward the grounded collector.

Analysis for Internal Flow of Tube on the Self Inflating Tire Using the FSI Method (FSI 기법을 이용한 Self Inflating Tire의 펌핑 튜브 내부 유동 해석)

  • Kim, Myeongjun;Seong, Inchul;Hwang, Inkyeong;Park, Taewon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.660-667
    • /
    • 2016
  • Maintaining proper tire air pressure is an essential element in ensuring vehicle safety. UHP Tires that boast of many safety features are increasing in the market. In particular, the development of "Self-Inflating Tire" technology is accelerating around the globe. Self-inflating tire refers to a technique for maintaining appropriate tire pressure. An internal regulator senses when tire inflation pressure has dropped below the set air pressure. The tire boosts air through the valve when rolling and compressed air enters into the tire. This procedure keeps the tire air pressure at an appropriate level and increases tire safety. Flow analysis of the internal tube is required to examine self-inflating tires. In this study, a method of tube flow analysis using the FSI Method is proposed. The valve system is also implemented to optimize the regulator and sensor.

A Study on the Optimization of Discharge Grille of Outdoor Unit of Air Conditioner (에어컨 실외기 토출그릴 형상 최적화)

  • Choi, Seok-Ho;Oh, Sai-Kee;Kim, Hyun-Jong;Jin, Geun-Ho;Oh, Si-Young;Kim, Byung-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.726-732
    • /
    • 2011
  • The aerodynamic and aeroacoustic performance of discharge grille of outdoor unit of air-conditioner was investigated in this study. Discharge grille is one of outdoor unit's important parts to affect the flow rate and Overall Sound Pressure Level(OSPL). New type of discharge grille was suggested based on the results of numerical simulation. To simulate the flow pattern near the propeller fan, commercial flow solver FLUENT was used. Sliding mesh method was used for rotating propeller fan and initial condition for unsteady model was calculated by Multiple Reference Frame(MRF) method. To minimize the interaction noise between fan blade wake and discharge grille, new discharge grille has radial rib which is aligned with trailing edge of fan blade. And inclined radial rib was adopted for reducing flow rate drop in discharge grille. The optimization of inclined angle of radial grille was performed experimentally.