• Title/Summary/Keyword: air filter

Search Result 1,005, Processing Time 0.021 seconds

A Study on Tuning Effects of Intake Manifold, Intake Pipe and Air Filter upon Performance and Exhaust Emissions of Driving Car (운행자동차 성능 및 배기 배출물에 미치는 흡기 다기관, 흡기 파이프 및 공기필터의 튜닝효과에 관한 연구)

  • Bae, Myung-whan;Ku, Young Jin;Park, Hui-seong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.5
    • /
    • pp.538-548
    • /
    • 2016
  • The purpose of this study is to identify the possibility of effective tuning works, understand the characteristics of tuning engine, and analyse the basic data of engine tuning inspection corresponding to the safe operation and environment of a driving gasoline car. The effects of tuning on the characteristics of performance and exhaust emissions under a wide range of engine speeds are experimentally investigated by the actual driving car with a four-cycle, four-cylinder DOHC, turbo-intercooler, water-cooled gasoline engine operating at four types of non-tuning, tuning 1, 2 and 3. The tuning parts in the gasoline engine are the intake manifold, intake pipe and air filter. In the experiment, the output, torque and air-fuel ratio of the five-speed automatic transmission vehicles were measured at the chassis dynamometer(Dynojet 224xLC) with one person on board. The exhaust emissions of $NO_X$, THC, CO, $O_2$ and $CO_2$, and excess air ratio(${\lambda}$) at the other chassis dynamometer(DASAN-MD-ASM-97-KR-HD) were also measured by the idle/constant-speed mode(ASM2525 mode) test method. It is found that the actual air-fuel ratios of non-tuning and tuning engines were shown to be lower than the stoichiometric air-fuel ratio with increasing engine speed, and the actual air-fuel ratio of non-tuning engine was slightly higher than those of tuning engines when the engine speed is more than 4000 rpm. The output was significantly increased by the tuning whereby the maximum output of tuning engine was more increased to approximately 117.64% than that of non-tuning engine. In addition, CO, THC and $NO_X$ emissions of non-tuning and tuning engines measured by the constant-speed test mode were all satisfied with the inspection standards. CO emission was increased, while THC and $NO_X$ emissions were reduced by tuning.

Airborne infection risk of respiratory infectious diseases and effectiveness of using filter-embeded mechanical ventilator and infectious source reduction device such as air cleaner (실내 공간에서의 호흡기 감염병 공기전파감염 위험도와 공기정화장치(필터 임배디드 기계식 환기설비 및 공기청정기 등 실내 감염원 저감 장치) 사용에 따른 효율)

  • Park, Sungjae;Park, Geunyoung;Park, Dae Hoon;Koo, Hyunbon;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.73-94
    • /
    • 2020
  • Particulate infectious sources, including infectious viruses, can float in the air, causing airborne infections. To prevent indoor airborne infection, dilution control by ventilation and indoor air cleaners are frequently used. In this study, the risk of airborne infection by the operation of these two techniques was evaluated. In case of dilution control by ventilation, a high efficiency air filter was embedded at the inlet of supply air. In this study, infectious source reduction devices such as indoor air cleaner include all kinds of mechanical-filters, UV-photo catalysts and air ionizers through which air flow is forced by fans. Two mathematical models for influenza virus were applied in an infant care room where infants and young children are active, and the risk reduction efficiency was compared. As a result, in the case of individually operating the ventilator or the infectious source reduction device, the airborne infection risk reduction efficiencies were 55.2~61.2% and 53.8~59.9%, respectively. When both facilities were operated, it was found that the risk of airborne infection was reduced about 72.2~76.8%. Therefore, simultaneous operation of ventilation equipment and infectious source reduction device is the most effective method for safe environment that minimizes the risk of airborne infection of respiratory infectious diseases. In the case of a space where sufficient ventilation operation is difficult, it was found that the operation of an infectious source reduction device is important to prevent the spread of infectious diseases. This study is meaningful in that it provides an academic basis for strategies for preventing airborne infection of respiratory infectious diseases.

Comparative assessment and uncertainty analysis of ensemble-based hydrologic data assimilation using airGRdatassim (airGRdatassim을 이용한 앙상블 기반 수문자료동화 기법의 비교 및 불확실성 평가)

  • Lee, Garim;Lee, Songhee;Kim, Bomi;Woo, Dong Kook;Noh, Seong Jin
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.10
    • /
    • pp.761-774
    • /
    • 2022
  • Accurate hydrologic prediction is essential to analyze the effects of drought, flood, and climate change on flow rates, water quality, and ecosystems. Disentangling the uncertainty of the hydrological model is one of the important issues in hydrology and water resources research. Hydrologic data assimilation (DA), a technique that updates the status or parameters of a hydrological model to produce the most likely estimates of the initial conditions of the model, is one of the ways to minimize uncertainty in hydrological simulations and improve predictive accuracy. In this study, the two ensemble-based sequential DA techniques, ensemble Kalman filter, and particle filter are comparatively analyzed for the daily discharge simulation at the Yongdam catchment using airGRdatassim. The results showed that the values of Kling-Gupta efficiency (KGE) were improved from 0.799 in the open loop simulation to 0.826 in the ensemble Kalman filter and to 0.933 in the particle filter. In addition, we analyzed the effects of hyper-parameters related to the data assimilation methods such as precipitation and potential evaporation forcing error parameters and selection of perturbed and updated states. For the case of forcing error conditions, the particle filter was superior to the ensemble in terms of the KGE index. The size of the optimal forcing noise was relatively smaller in the particle filter compared to the ensemble Kalman filter. In addition, with more state variables included in the updating step, performance of data assimilation improved, implicating that adequate selection of updating states can be considered as a hyper-parameter. The simulation experiments in this study implied that DA hyper-parameters needed to be carefully optimized to exploit the potential of DA methods.

The optical characteristic of Fabry-Perot interferometer filter for UV meter (UV meter용 패브리-페로 간섭필터 제작 및 광학특성연구)

  • Park, Moon-Chan;Jung, Boo-Young;Choi, Hae-Jung;Chen, Ko-Hsien;Hwangbo, Chang-Kwon;Kim, Hyung-Doo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.463-471
    • /
    • 2004
  • The Fabry-Perot interferometer filters for UV meter were designed using the design program of optical thin films. From the data obtained, two filters were fabricated. The transmittance of two filter were measured by spectrophotometer in order to analysis their optical property. The transmittance was controlled by the thickness of Ag reflector and the wavelength of the transmission was controlled by the thickness of $SiO_2$ spacer. The two UV filters were fabricated by the RF magnetron sputtering which are the multilayers of [air/$SiO_2$(174.6 nm)|Ag(78 nm)|$SiO_2$(68 nm)|Ag(78 nm)|Cr(5 nm)|glass] and [air/$SiO_2$(174.6 nm)|Ag(S8 nm)|$SiO_2$(56 nm)|Ag(58 nm)|Cr(S nm)|glass]. One filter has the maximum transmittance of 6% at the about 370nm and it has the transmittance of below 0.2% at 400nm. The other filter can be found that the transmittance is increased as the thickness of Ag is decreased and the wavelength of the transmission is controlled by the thickness of $SiO_2$ spacer layer.

  • PDF

Air quality monitoring and evaluation of bag filter performance for removal of fine particulates in roadway tunnels (도로터널 내 공기질 측정과 Bag Filter를 이용한 미세먼지 제거 성능평가)

  • Kim, Beom-Seok;Park, IL-Gun;Jung, Dong-Gyun;Lee, Sang-Don;Hong, Min-Sun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.5
    • /
    • pp.523-531
    • /
    • 2015
  • Air quality was monitored in four roadway tunnels located near Seoul metropolitan area from 7:00AM to 9:00AM. PM10 concentrations range $111{\sim}268{\mu}g/m^3$, which are 2~5 times higher than annual standard $50{\mu}g/m^3$, and PM2.5 concentrations range $35{\sim}65{\mu}g/m^3$, which are 1.5~2.5 times higher than annual standard $25{\mu}g/m^3$. Benzene concentrations range 300~500 ppb, which are 200~300 times higher than 1.5 ppb which is air quality standard. Four-month long term air quality monitoring and test results in one of long tunnels show that PM10 range $30{\sim}400{\mu}g/m^3$ and over 97% of them can be removed by bag filter, effectively. Finally, benzene concentrations range 250~350 ppb.

Development of the Seed Filter for the enhancement of cigarette filter biodegradability (필터 생분해성 증진을 위한 종자 필터 개발 및 적용 효과)

  • Kim, Soo-Ho;Kim, Min-Kyu;Hwang, Eui-Il;Han, Young-Rim;Lee, Chang-Kuk;Yeo, Woon-Hyung
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • Cigarette filters containing Brassica Rapa L. seeds of the dark brown and round shaped were evaluated to determine the effect of seed addition on filter degradability. The seeds with germination capability under the tar/nicotine condition in the preliminary test, were put into the active carbon part of the filter(12mm) during filter rod making by the kit. The $4{\pm}2$ pieces of the seeds were put into the opened fiber bundle of the filter tow. In order to test the germination rate of the seeds, seed filters were placed either in a petri dish or test-pot in a conditioned area ($25^{\circ}C$, 70 % RH). The seed filters were placed outdoors exposed to natural conditions with the periodic water supply. The seeds in the smoked filters showed 90 % germination rate after a month under the open air condition. No significant differences in the sensory evaluation and analysis were obtained when the control sample was compared to the same cigarettes with the seeds.

A Study on the Temperature Distribution at the Surface of Diesel Particulate Filter and Partitioned Electric Heater according to the Conditions of Heating and Flow using an Infrared Temperature Camera (적외선 온도 카메라를 이용한 분할형 전기히터 가열 및 유동 조건에 따른 전기히터와 매연필터 표면에서의 온도 분포에 관한 연구)

  • Lee, Choong-Hoon;Paik, Sung-Chon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.7-14
    • /
    • 2008
  • The temperature distribution in a surface of diesel particulate filter(DPF) was measured using an infrared temperature camera. In order to regenerate the DPF, five partitioned electric heaters were used for heating the ceramic filter. The five partitioned heaters were switched on/off with some time interval one the other. The surface temperature distribution in the ceramic filter and electric heaters were measured with varying both the electrical power supply to the heaters and the mass flow rate of the air supply from a blower. The higher mass flow rate in the DPF system enhanced the uniformity in the surface temperature distribution of the ceramic filter due to effective convection heat transfer. The flow in the monolith ceramic structure of the DPF move mainly in the axial direction, which could be identified from the surface temperature of the ceramic filter.

Filter-based Correction for Positive Sampling Artifacts in the Determination of Ambient Organic Carbon (여과지를 이용한 유기탄소의 측정 오차 보정)

  • Kang, Byung-Wook;Yeon, Ik-Jun;Cho, Byung-Yeol;Park, Sang-Chan;Lee, Hak-Sung;Jeon, Jun-Min;Na, Kwang-Sam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.63-72
    • /
    • 2011
  • This study describes the impact of positive sampling artifact caused by a filter-based sampling in the determination of ambient organic carbon (OC). Three different sampling media combinations were employed for this investigation: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), and (3) quartz filter and quartz filter behind Teflon filter (Q-QBT). The measurement of ambient OC was carried out at a semi-urban site near oceanside at the end of November of 2008. It was found that Q-alone sampling configuration resulted in a higher OC than QBQ and Q-QBT by 14% and 28%, respectively due to no correction for positive artifact caused by adsorption of gas-phase OC onto the filter. A lower quantity of OC was collected from the backup quartz filter on QBQ than that from Q-QBT. A possible explanation is that the front quartz filter of QBQ was not fully saturated with gas-phase OC during the sampling period, allowing smaller amount of gas-phase OC to reach the backup quartz filter. The contribution of positive artifact to $PM_{2.5}$ mass was approximately 2.15 ${\mu}g/m^3$ which is equivalent to 6% in terms of Q-QBT sampling configuration. The positive artifact was found to be more dominated during summer than during winter, showing temperature dependence. It was concluded that Q-QBT sampling configuration offers less impact of positive artifact on ambient OC sampling than QBQ in quantification of OC.

Performance and reusability of certified and uncertified face masks (보건용 마스크 초미세먼지 제거 성능 평가 및 재사용 연구)

  • Lee, Haebum;Kim, Seojeong;Joo, HungSoo;Cho, Hee-joo;Park, Kihong
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.191-202
    • /
    • 2019
  • In this study, performance (particle removal efficiency and breathing resistance) of several commercially available face masks (electrostatic filter masks (KF80 certified), a nanofiber filter mask (KF80 certified), and an uncertified mask) with their filter structure and composition were evaluated. Also, effects of relative humidity (RH) of incoming air, water and alcohol exposure, and reusability on performance of face masks were examined. Monodisperse and polydisperse sodium chloride particles were used as test aerosols. Except the uncertified mask filter, PM2.5 removal efficiency was found to be higher than 90%, and the nanofiber filter mask had the highest quality factor due to the low pressure drop and high removal efficiency (nanofibers were arranged in a densely packed pore structure and contained a significant amount of fluorine in addition to carbon and oxygen). In the case of the KF80 certified mask, the removal efficiency was little affected when the RH of incoming air increased. When the mask filters were soaked in water, the removal efficiency of mask filters was degraded. In particular, the uncertified mask filter showed the highest removal efficiency degradation (26%). When the mask was soaked in alcohol, the removal efficiency also decreased with the greater degree than the water soaking case. The nanofiber mask filter showed the strongest resistance to alcohol exposure among tested mask filters. During evaluation of reusability of masks in real life, the removal efficiency of certified mask filter was less than 4% for 5 consecutive days (2 hours per day), while the removal efficiency of uncertified mask filter significantly decreased by 30% after 5 days.

A Study on Pressure Drop Characteristics of Automotive Cabin Air Filters (자동차 실내공기 정화용 Cabin Air Filter의 압력손실 특성에 관한 연구)

  • 박현설;박영옥;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.229-230
    • /
    • 2000
  • 자동차 보유대수의 증가와 더불어 열악해진 도로환경으로 인해 자동차를 이용하는 운전자와 승객의 보다 쾌적한 자동차 실내 환경에 대한 요구가 점점 증가하고 있다. 도로 주행시 자동차내로 유입되는 공기 중에는 도로먼지, 석면입자, 박테리아, 꽃가루 등의 다양한 악성 미립자상 물질과 오존, 벤젠, 톨루엔, 포름알데히드, 암모니아, NOx, SOx 둥의 유해 기체상 물질이 다량 함유되어 있다. 특히 미세 입자의 크기는 대부분이 5.0 $\mu\textrm{m}$로 미세하여 인간의 상부 호흡기관인 코에서 폐포까지 깊숙이 침착되는 것으로 보고되고 있다. (중략)

  • PDF