• 제목/요약/키워드: air filter

검색결과 1,003건 처리시간 0.08초

양전하가 부가된 수처리 필터의 입자제거특성에 관한 연구 (A Study on the Positively Charged Filter for Removing Fine Particles in Water)

  • 정성학;김종원;김상희;전병헌;이승갑;이재근;안영철
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.454-460
    • /
    • 2012
  • The purpose of the present work is to investigate the removal characteristics of positively charged filters for capturing negatively charged particles such as bacteria and virus in water. In order to reduce the pressure drop and increase the filtration efficiency, the filter media, modified by charge modifier having positive functional groups, is developed and evaluated. Improved liquid filters have been developed with the modified surface charge to capture and adsorb particles by electrokinetic interaction between the filter surface and particles contained in an aqueous liquid. The positively charged filter media is composed of glass fiber, cellulose and poly-ethylenimine resin for positively charging with the variation of volume ratio. The zeta potential value of the positively charged filter is +37.92 mV at the glass fiber and cellulose content ratio of 50 : 50 with resin content of 100%, while that of the PSL test particle is -23.5 mV at pH 7. The removal efficiency of the electro-positively charged filter is 98% for PSL particles of 0.11 ${\mu}m$, while that of the negatively charged filter is 7%. The positively charged filter media showed the potential to be an effective method for removing fine particles from the contaminated water for liquid filtration.

사각형 여과 집진기 충격기류 탈진시스템의 기초 연구 (The Fundamental Study on Pulse Jet Cleaning of Rectangular Bag-Filter System)

  • 박승욱;김태형;양준호;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권2호
    • /
    • pp.149-160
    • /
    • 2008
  • Bag-filter system has been widely used in industrial field to remove the particulate matters from the exhaust gas. The cylindrical type of bag-filter has been generally used. But it has many shortcomings. The reattachment of separated particles on the surface of bags could result in high pressure drop of bag-filter system and subsequent decrease of air flow rate since the cylindrical type bag-filter system should have the upward flow pattern. In addition, the supply of very high pressure pulse air jet to remove particulate matters on the surface of filter could result in a frequent rupture of bags. To overcome these shortcomings of the cylindrical type, the rectangular type was developed in the developed countries and imported to Korea. But, there was not many design data available to understand the mechanisms. Thus, the fundamental experiments were conducted in this study to get some ideas about the pulse jet cleaning of rectangular type bag filter system. The experimental factors are as follows; pulse distance, pulse duration, pulse interval, pulse pressure and pulse nozzle type. Experiments followed the factorial design method. With the shorter pulse distance, the distribution of pressure drops was relatively not uniform while the particulate removal efficiency was higher. With the longer duration of pulsing and the more number of pulse nozzle, the removal efficiency was higher and the pressure drop distribution was more uniform.

대기오염물질로 인한 연료전지자동차 출력 변화에 대한 연구 (The Effect of Air Pollutant to Fuel Cell Electric Vehicle)

  • 이준기;박상선;설용건
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.154-157
    • /
    • 2009
  • Fuel cell is spotlighted as next energy source of future. The fuel of vehicle will be changed from fossil fuel such as gasoline, diesel to hydrogen. Polymer electrolyte membrane fuel cell(PEMFC) will be used to fuel cell vehicle because of its suitability. PEMFCs need oxygen for cathode. Because PEMFCs in vehicle use air for oxygen, air pollutant will be effect to performance of PEMFC. In this study, we examine a type of filter and pollutant gas how can be effect to performance of fuel cell electric vehicle.

  • PDF

패널용 에어컨의 역률 개선 및 고조파 저감 (Power Factor Correction Improvement and Total Harmonic Distortion Reducing for Panel's Air-conditioner)

  • 박성우;박정우;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.258-261
    • /
    • 2001
  • High Power factor Active Filter converter is used for Inverter Air conditioner power supply to meet IEC standard. In the active filter topology for power factor, extra switch just control the input current indirectly to meet the IEC standard for reducing the cost and size. In this paper, low cost converter was suggested by simulation using extra switch which auxiliary pulse is inserted and quasi resonant soft switching topology control is adapted for panel's inverter air conditioner converter Inserting auxiliary Pulse method to the extra switch has the benefit of reducing THD by low cost input control circuit. And also quasi resonant soft switching topology can reduce switching loss. So both technical is suitable for Panel's Air conditioner.

  • PDF

청정공간에서 제품과 팬필터유닛의 위치에 따른 오염물질의 전파 특성 (Characteristics of Contaminant Transfer in a Clean Space for the Location of Product and Fan Filter Unit)

  • 김혁순;노광철;이영구;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.452-457
    • /
    • 2008
  • We performed a study on the contaminant transfer in a clean space for the location of product and fan filter unit using computational fluid dynamics analysis. To simplify the real product moving process, three different non-moving cases regrading the locations of product were selected: no product, at the lower side, and at the upper and lower sides. And to investigate the characteristics of the contaminant transfer, the arrangement of fan filter units was varied. Local mean air-age and contaminant distribution were used as evaluation indices. From the results, the contaminant transfer to the product was the most when the products were simultaneously located at the upper and lower sides. And the contaminant was easily exhausted regardless of the location of product when the fan filter units were properly arranged at the top side of the clean space.

  • PDF

응집과 여과를 이용한 조류의 초고속 제어에 관한 연구 (High-rate Removal of Algae by Using of Filtration System with Coagulant Addition)

  • 윤상린;김동하;이영규
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.221-228
    • /
    • 2002
  • Abundant growth of algae in raw water sources caused by eutrophication brings about significant side effects on water supply, such as taste and order problem, oxygen depletion, toxic material secretion, and filter clogging problem in water treatment process, etc. The purpose of this research is to remove the algae and phosphorus compounds in the Pal-dang reservoir promptly by using the upflow filtration system with coagulant addition. The filter tower consisted of sand media and sieve filter with air back-washing process. By using coagulation and filtration with $132{\mu}m$ pore size filter, about 55% and 70% of algae and phosphorus compounds were removed respectively. The experimental conditions were as follows; head loss of 0.2m, linear velocity of 200m/day, and filtration flux of 1000($L/m^2/day$). In the case of filtration with cartridge type filter of $25{\mu}m$ pore size, the filtration flux was about 7800 LMH, and the removal ratios of COD, SS, T-P, and Chlo-a. were 61%, 99%, 54%, and 98%, respectively. However, high pressure air back-washing process with should be required for the maintenance of such high filtration flux.

공기순환장치 적용 오존 플라즈마 살균장치 개발 (Development of Ozone Plasma Sterilizer with Air Circulation Device)

  • 안준;전영남
    • 한국산업보건학회지
    • /
    • 제31권1호
    • /
    • pp.105-110
    • /
    • 2021
  • Objectives: The purpose of this study was to develop a new sterilization plasma device that would be proficient at sterilizing and removing pathogenic bacteria and viruses, and applicable to air purification systems. Methods: In order to understand the performance characteristics, the discharge characteristics of a packed bed DBD reactor and the ozone reduction characteristics of an ozone filter installed at the outlet of the reactor were investigated. Results: The novel packed-bed DBD reactor was proposed, and it was confirmed that the plasma discharge was uniformly and stably discharged throughout the entire layer, and sufficient ozone was generated for sterilization. The ozone filter was tested for three methods: adsorption, adsorption-decomposition, and catalytic decomposition. When the filter thickness was 30 mm, the ozone concentrations were 0.03 ppm, 0.01 ppm, and 0.21 ppm, respectively. The adsorption and adsorption-decomposition methods satisfied the EPA standard of less than 0.05ppm, but the catalytic decomposition method did not. Conclusions: It was confirmed that the adsorption-decomposition method has relatively excellent ozone filter performance and can provide the best ozone filter.

The Modeling of the Differential Measurement of Air Pressure for Non-intrusive Sleep Monitoring Sensor System

  • Chee, Young-Joon;Park, Kwang-Suk
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권6호
    • /
    • pp.373-381
    • /
    • 2005
  • The respiratory and heart beat signals are the fundamental physiological signals for sleep monitoring in the home. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body which makes long term measurement difficult and troublesome. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The concept of the balancing tube between two air cells is suggested to increase the robustness against postural changes during the measurement period. With this balancing tube, the meaningful frequency range could be selected by the pneumatic filter method. The mathematical model for the air mattress and balancing tube was suggested and the validation experiments were performed for step and sinusoidal input. The results show that the balancing tube can eliminate the low frequency component between two cells effectively. This technique was applied to measure the respiration and heart beat on the bed, which shows the potential applications for sleep monitoring device in home. With the analysis of the waveform, respiration intervals and heart beat intervals were calculated and compared with the signal from conventional methods. The results show that the measurement from air mattress with balancing tube can be used for monitoring respiration and heart beat in various situations.