• 제목/요약/키워드: air exchange rate

검색결과 203건 처리시간 0.032초

토양과 공기유동특성이 토양-공기 열교환기 성능에 미치는 영향 (Effects of Soil and Air Flow Characteristics on the Soil-Air Heat Exchanger Performances)

  • 김영복;김기영
    • Journal of Biosystems Engineering
    • /
    • 제23권1호
    • /
    • pp.21-30
    • /
    • 1998
  • A theoretical model was developed to evaluate the effects of soil and airflow characteristics on the soil-air heat exchanger performances. The model, which includes three-dimensional transient energy and mass equilibrium-equation, was solved by using a computer program that uses Finite Difference Methods and Gauss-Seidel iteration computation. Energy gains, heat exchange efficiencies, and outlet air temperature are presented including the effects of soil moisture content, soil conductivity, soil thermal diffusivity, and soil initial temperature. Also, data related to the effects of airflow rate and inlet air temperature on the thermal performance of the system are presented. The results indicated that energy gains depend on soil conductivity, soil thermal diffusivity, and soil initial temperature. Heat exchange efficiencies relied on air mass flow rate and soil moisture content.

  • PDF

실간환기량 측정을 위한 추적가스 실험방법론에 관한 연구 (A Study on Tracer Gas Methodology to Measure Interzonal Airflow Rates)

  • 한화택;조석효
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.606-612
    • /
    • 2009
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

지열 히트펌프 시스템의 계절별 지중 열교환 특성 및 지반내 온도 변화 (Temperature monitoring and seasonal borehole heat exchange rate characteristics of a geothermal heat pump system)

  • 심병완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.452-455
    • /
    • 2007
  • The geothermal heat pump system is designed for cooling and heating for three stories building (2,435 $m^2$) includes total 79 heat pumps. Therefore, the monitoring system is installed for each floor and the data is automatically transmitted to the monitoring system. Heat exchange rate and temperature of a geothermal heat pump system have been monitored for a long period. The seasonal operation of geothermal heat pump shows the different shape of heat exchange rate for cooling and heating. Ground water flow can influence on heat exchange rate and thermal storage of the system. In order to define the hydraulic characteristics and groundwater temperature variation, the relationships among air temperatures, groundwater temperatures, water table, and precipitation are analysed.

  • PDF

지중열 이동 시뮬레이션을 이용한 수평형 지열시스템의 채열성능 예측 (Prediction of the Heat Exchange Rate for a Horizontal Ground Heat Pump System Using a Ground Heat Transfer Simulation)

  • 남유진;채호병
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.297-302
    • /
    • 2013
  • The ground source heat pump (GSHP) system has attracted attention, because of its stability of heat production, and the high efficiency of the system. However, there are few studies on the prediction method of the heat exchange rate for a horizontal GSHP system. In this research, in order to predict the performance of a horizontal GSHP system, coupled simulation with a ground heat transfer model and a heat exchanger circulation model was developed, and calculation of heat exchange rate was conducted by the developed tool. In order to optimally design the horizontal GSHP system, the flow rate of circulation water, and the depth and buried spaces of heat exchangers were considered by the case study. As a result, the temperature of circulation water and the heat exchange rate of the system were calculated in each case.

바닥재에서 발생하는 준휘발성유기화합물 측정 및 챔버 내 기류 특성 평가 (Measurement of Semi-Volatile Organic Compounds from Flooring Material and Evaluation on Airflow Characteristics in a Test Chamber)

  • 서장후;;임만택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.762-767
    • /
    • 2009
  • Some types of semi-Volatile organic compounds (SVOC) that are emitted from plastics used in building materials and household appliances have associated health risks, even at low concentrations. In this study, micro chamber method for measuring SVOC is introduced and SVOC such as di (2-ethylhexyl) phthalate and butylated hydroxyltoluene emitted a flooring material were measured using a micro chamber method. Airflow characteristics in a micro test chamber deeply depended on air exchange rate. From the evaluation using an index of air change efficiency, such as the air age and the coefficient of air change performance, a fixed air exchange rate of $1.5\;h^{-1}$ in the micro chamber is desirable.

  • PDF

백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구 (Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction)

  • 왕쩐후안;전종균;권영철
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

Analysis of Factors Influencing Korea's Air Trade with China

  • Lim, Jae-Hwan;Kim, Young-Rok;Choi, Yun-Chul;Choi, Yu-Jeong
    • 한국항공운항학회지
    • /
    • 제29권3호
    • /
    • pp.111-116
    • /
    • 2021
  • This study aims to identify the representative factors affecting the air trade between the two countries over the past 20 years, targeting China, Korea's largest trading partner for air transport. In the analysis, the two countries' GDP, GDP per capita, and tariff rates, as well as exchange rates, international oil prices, and FTAs were used as variables. For the analysis method, OLS multiple regression analysis was performed, and each was analyzed by dividing the export amount, import amount, and trade amount. As a result of the analysis, China's GDP and Korea's GDP per capita showed a positive (+) direction, an increase in the exchange rate resulted in an increase in the amount of trade, and an increase in the tariff rate resulted in a decrease in the amount of trade. Whether the FTA was concluded or not acted as a factor in increasing the amount of trade between the two countries.

추적가스를 이용한 실간환기량 산정방법에 따른 불확실성 해석 (Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods)

  • 한화택;조석효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.529-534
    • /
    • 2008
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

  • PDF

Indoor Air Quality of Acidic Air Pollutants at a Private House in Seoul During the Spring Months

  • Lee, Hak-Sung;Kang, Byung-Wook;Kang, Choong-Min;Yeo, Hyun-Gu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권E3호
    • /
    • pp.109-115
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality at a private house in Seoul during the spring period. All indoor and outdoor samples were measured simultaneously using an annular denuder system. The data set was collected on twelve different days with a 24-hr sampling period in April and May 1997. The chemical species measured were HN $O_3$, HN $O_2$, S $O_2$ and N $H_3$in the gas phase and P $M_{2.5}$ (dp 2.5 ${\mu}{\textrm}{m}$), S $O_4$$^{2-}$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ in the particulate phase. Indoor concentrations of HN $O_2$, N $H_3$, and P $M_{2.5}$ were greater than outdoor levels. However, indoor concentrations of HN $O_3$, S $O_2$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ were less than those found from outdoors. In the case of S $O_4$$^{2-}$, the indoor and outdoor concentrations were similar. Indoor concentrations of P $M_{2.5}$ , S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ were dependent upon the outdoor concentrations. A tracer-gas decay technique with sulfur hexafluoride (S $F_{6}$ ) as the tracer gas was used to estimate the air exchange rate of a private home in the spring. The average air exchange rate was computed to be 2.87 h $r^{-1}$ .X> .

  • PDF

한반도 서해안 배경관측점을 중심으로 한 대기 중 메탄의 배출과 침적 (The Soil-air Exchange Characteristics of Methane in a Western Coastal Area of Korea during Spring 2002)

  • 김민영;조석주;김준;이강웅;김기현
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.275-284
    • /
    • 2003
  • The soil -air exchange processes of CH$_4$ were investigated in Hari district of Kang Hwa Island, Korea during the late April 2002. In the course of our field experiments, we measured the concentration, concentration gradients (between two different heights of 1 and 5 m), and the fluxes of CH$_4$ using the surface layer gradient microm-eteorological methods. If the relationships between CH$_4$ fluxes and the relevant environmental parameters are examined, CH$_4$ fluxes were found to be affected most significantly by parameters like wind speed. The results of our study indicate that the study area behaved as a net source of CH$_4$ to the atmosphere with a net daily emission rate of 3.6 mg m ̄$^2$ The findings of relatively low exchange rate observed at our study site suggest that the rice paddy area investigated prior to planting period can behave as a moderate source of methane.