• Title/Summary/Keyword: air cleaners

Search Result 54, Processing Time 0.022 seconds

Estimation of the Vibration Endurance Characteristics of Air Cleaner Insulators for Vehicle (차량용 에어클리너 인슐레이터의 진동 내구성 평가)

  • 김정헌;김석현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.931-936
    • /
    • 2004
  • In this paper, vibration endurance test is carried out on rubber insulators used fur vehicle air cleaners. Based on the test results, endurance characteristics depending on type and material of the insulators are estimated. Frequency response characteristics of the air cleaner system are investigated to identify the cause of wear and failure in the insulators occurred during the endurance test. New insulator models with improved endurance characteristics are proposed by changing the frequency response property of the air cleaner system.

  • PDF

Estimation of the Vibration Endurance Characteristics of Air Cleaner Insulators for Vehicles (차량용 에어클리너 인슐레이터의 진동 내구성 평가)

  • Kim Jung Heon;Kim Seockhyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.897-902
    • /
    • 2004
  • In this paper, a vibration endurance test is performed on rubber insulators used for vehicle air cleaners. Based on the test results, the endurance characteristics depending on the type and the material of the insulators are estimated. The frequency response characteristics of the air cleaner system including the insulator are investigated to identify the cause of wear and failure of the insulator. New insulator models with improved endurance characteristics are proposed and tested. Test results show that the vibration endurance property of the insulator is strongly dependent on the frequency response characteristics of the air cleaner system as well as the deformed shape of the insulator.

Flow Analysis of Air Cleaner and Resonator by Shape (형상별 에어클리너와 레조네이터의 유동에 관한 연구)

  • Han, Moonsik;Cho, Jaeung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.23-28
    • /
    • 2019
  • In this study, flow analysis results according to different air cleaner and resonator configurations were used to investigate flow and velocity. Among models A, B, and C, model B had the higher speed and pressure. Model B is therefore considered suitable as an air cleaner. This study aims to design optimal shapes of air cleaners and resonators without noise sources.

Characteristic Analysis of Electret Filters made by Electrospinning (전기방사를 통해 제조된 정전기 보유 필터의 표면전위 및 대전량에 따른 성능특성 분석)

  • Kim, Gil-Tae;Ahn, Young-Chull;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.820-824
    • /
    • 2008
  • Electret filter media are used in general ventilation filters, disposable respirators, vehicle cabin filters, vacuum cleaners and room air cleaners. There are basic mechanisms of interception, inertial impaction, diffusion, gravitational settling, electrostatic attraction by which an aerosol particle can be deposited onto a fiber in a filter. The ability of fine particle removal strongly depends on the electrostatic forces between particles and polarized fibers. Thus, the stability of the fiber polarization is a major factor in the reliability of electret filters. In this study, the electret filter is made by electrospinning process using Polystyrene which is dissolved by 5 : 5 of Tetrahydrofuran (THF) and Dimethylformamide (DMF). Also the electrical properties and the filtration performances of electrospun filter media are Quantitatively investigated. Electrical properties of electrospun filters have been studied on surface charge potential and surface charge density. Also the filtration performance of the electret filters are evaluated on collection efficiency. The surface charge potential and the surface charge density of electrospun PS filters are increased with increasing applied voltage and saturated at 30 kV of applied voltage. Also collection efficiency of electro spun filters is increased with increasing surface charge potential and surface charge density. But the surface charge potential is decreased by natural decay and it causes deterioration of particle collection efficiency.

Analysis of Indoor Air-flow with Air Cleaners (공기청정기에 의한 실내기류 해석)

  • Kim, Young-Saeng;Mo, Jin-Yong;Lee, Jae-Kwon;Han, Jae-Oh
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.57-62
    • /
    • 2005
  • 본 연구는 공기청정기의 성능에 영향을 미치는 인자로서 홉입구, 배기구의 위치 및 형상, 그리고 실내 공간상 배치 등에 대해 수치해석에 의한 모사를 통하여 평가하였다. 해석방법으로는 먼저 유동장을 해석한 후 고정된 유동장 내에서의 먼지 입자의 거동을 검토하였다. 배기구 위치에 의한 성능해석 결과는 배기구를 상면에 위치하게 할 경우 양 측면에 위치한 구조보다 우수한 성능을 나타내었으며, 설치위치에 대한 성능해석 결과는 제한적이나 현관 옆에 설치할 경우 해석된 두 가지 모델 모두 우수한 성능을 나타내었다.

  • PDF

An Air Cleaning Efficiencies of Wet Air Cleaner in the Swine Finishing Winch Curtain Stall (윈치커튼식 비육돈사에서 습식공기정화기의 공기정화 효율 분석)

  • Oh, I.H.;Kim, W.G.;Lee, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • High concentration of $NH_3$, $CO_2$, and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and lamer health, and production ability. Therefore, it is necessary to keep clean the inside of stall air to increase the productivity. A wet type air cleaner has been developed to clean the stall air. The work principle is that the inside air are sucked through the fan, and the rotating discs make a water into a fineness spray and blows into the stall. The spray can take the dust, $NH_3$, and odor from the stall inside air and give back to the circulating water, which can be refreshed in 2 hours interval. In the Present study, we measured the $NH_3$, dust, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with on-mode and off-mode of wet air cleaners. In fall, the concentrations of $NH_3$ in off-mode stall were maximum 24 ppm and minimum 16 prm, and the average was 18.2 ppm. However in on-mode stall the $NH_3$ concentrations were maximum 7ppm and minimum 1ppm, and the average was 2.7ppm. The concentration of $NH_3$ in on-mode was 74% lower than off-mode stall. Odor was measured by olfactometer. In the off-mode stall, the odor unit was 3,800 OU/$m^3$, but in the on-mode stall the odor unit was 2,100 OU/$m^3$ Odor removal efficiency was about 45% in on-mode stall. The dust measure was divided into 3 categories, $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$. Whereas the $PM_{10}$ showed no significant differences between the tests, $PM_{2.5}$ and $PM_{1.0}$ in the fine particle range reduced remarkably in the on-mode.

  • PDF

An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer (무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석)

  • Oh, I.H.;Lee, J.H.;Lee, K.H.;Lee, J.H.;Lee, D.S.;Eo, S.M.;Lee, M.L.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

Development of Air Cleaning System for Railroad Vehicles (차세대 객차용 청정시스템 개발)

  • Park, Duck-Shin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2109-2113
    • /
    • 2008
  • As the standard of living is higher, the passengers using public transportations desire better qualities of environment as well as more comfortable indoor environment. In case of train, the passengers' comfort in passenger cabin is one of the most important elements to be competitive with other transport systems. The indoor air quality of the cabin should be managed properly, because many passengers travel for a long time in the small space of $144\;m^3$. For proper management of the air quality, the heating, ventilation and air conditioning (HVAC) system is required for the ventilation of the compartment. To maintain comfortable environment in the compartment, the automatic ventilation system is needed to exchange the indoor air with fresh air or clean indoor air. In this study, we investigated the indoor air quality (PM-10, $CO_2$, and VOCs) in the compartment of train. In addition, type and pattern of PM-10 has been analyzed through the clustering analysis. Based on the analysis, we could found that the fine particulate matters in the compartment can be a serious hazard to human. To control the concentration of PM-10 and $CO_2$ air cleaners were developed. Through this study, it is expected that people who take a train will be in a more comfortable environment.

  • PDF

Effect of air cleaner on stress hormones of pig and pork quality

  • Kim, Yeon-Ha;Kim, Ki-Youn
    • Journal of Animal Science and Technology
    • /
    • v.63 no.4
    • /
    • pp.892-903
    • /
    • 2021
  • The objective of this study is to investigate effect of air cleaner operated during pig breeding period on stress hormones of pigs and their pork quality. The stress hormones (cortisol, epinephrine and norepinephrine) in blood sample of pigs reared in the housing rooms with or without air cleaner have been measured according to a pig's rearing stage: 0 day (farrowing), 21st day (farrowing-weaning), 70th day (weaning-nursery), 140th day (nursery-growing), and 180th day (growing-fattening). The comparison of pork quality according to the application of an air cleaner was performed through the carcass analysis of the pigs shipped from swine house. The levels of cortisol, epinephrine, and norepinephrine in pigs reared in housing rooms with and without air cleaners were found to be within the range of normal reference values. Among pork quality evaluation items, the thickness of intermuscular fat and final carcass grade of pigs raised in housing room with air cleaner was generally superior to those of pigs raised in housing room without air cleaner (p < 0.05). Based on the results obtained from this study, it is concluded that air cleaner does not have a significant effect on reducing pig stress but contributes to improving pork quality in pig breeding.

Review of Recent Studies on the Airborne Infection (국내외 공기감염 분야 연구동향)

  • Kwon, Soon-Bark;Kim, Chang-Soo
    • Particle and aerosol research
    • /
    • v.6 no.2
    • /
    • pp.81-90
    • /
    • 2010
  • Several studies have suggested the possibility of airborne transmission of infectious diseases such as tuberculosis, pandemic influenza. because the number of patients increases explosively, if infectious disease had a high basic reproduction number, pharmaceutical interventions such as vaccination, chemoprophylaxis in the early stage of epidemic. Thus, non-pharmaceutical interventions such as mask-wearing, installing air cleaners, school closure are important to control and prevent the infectious diseases. However, the current technology on the mask, air cleaning, ventilation, and etc., seems to be not originated from the understanding of infection via airborne transmission. It is important to estimate the aerodynamic behavior of saliva droplets by coughing or speaking in order to understand the phenomena of airborne infection. In addition, the prediction of transmission of infectious diseases through the air is critical to prevent or minimize the damage of infection. In this review, we reviewed the recent studies on the airborne infection by focusing on the aerodynamic characteristics of saliva droplets and modeling of airborne transmission.