• Title/Summary/Keyword: air circulation

Search Result 542, Processing Time 0.024 seconds

A Study of Environmentally Friendly Residential District Development -Concentrated on Gang-buk new town residential district- (친환경 주거단지 개발계획에 관한 이론적 고찰 -강북뉴타운 주거단지를 대상으로-)

  • Kil, Ki-Seok
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.53-63
    • /
    • 2004
  • According to the New Town Development Plan, Gang-buk area, a symbol of slum in Seoul will be changed new residential area. There are a lot of challenges for success this project. First of all, new ways of city plan "pre-plan and development" and "environmentally friendly development" are necessary to carry out this plan. Another important idea is how to overcome conflicts such as unbalanced development, a traffic jam and environment problem. Also, Government and a citizen agree that this project have to accept eco-protectable and sustainable development theory. For increasing green area ratio and keeping eco-diversity, planting at roofs and water circulation system in residential complex are compulsory. Green network based on environmentally friendly development provides a natural energe stream on eco-system and protects a city from air pollution, hot air island phenomenon and a flood.

The question at issue of connector wire in High Speed Railway Catenary System of France (프랑스 고속철도 전차선로 시스템에서 균압선의 문제점)

  • 안영훈
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.636-651
    • /
    • 2000
  • In these days, SNCF replace the connector wire (M-T type) with a dropper has a equivalent role and function of the one in general lines of TGV, and change the connector wire (T-T-M-M-T-T, T-T-M-M-T type, etc) into a New one has more flexible cable in parallel lines (air section air joint, etc) of TGV. The Connector wire has many problems according to a flow of excessive circulation current (or traction current) and a sudden rise of temperature on catenary when electric locomotive is running in high speed. To solve the question at issue of the connector wire in high speed railway catenary system of Fiance, SNCF return their operating experience in TGV lines to design and execution of catenary system Therefore, we have to deal with the question in design and execution of catenary system for kyoungbu HSR line because we will spend a lot of time and more money for maintenance than for construction of that.

  • PDF

Fluid flow in the freezing compartment of the B/F Refrigerators (B/F형 냉장고 냉동실의 결빙원인에 관한 연구)

  • Yang, S.Y.;Kim, Y.K.;Park, J.S.;Jung, H.Y.;Lee, Y.W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.530-533
    • /
    • 2008
  • Refrigerators have some frost related problems in a freezing compartment. The frost formation in the refrigerator gives customers a bad impression concerning quality problems. Therefore, many engineers have been studying the optimum solution to avoid frost formation. But the problem of frost formation is very complex and hard to approach to the answer. The frost generation of a household refrigerator have been widely known that is closely related to the distribution of temperature inside the compartment. The distribution depends on the cold air circulation inside the refrigerator. So frost problem can be reduced and energy consumption efficiency also improved through optimization of air flow fields inside the freezing compartment. In this paper, numerical simulation has been carried out to check fluid flow. The variation of temperature at the walls was measured and quantitative analysis of frost generated from the freezing compartment was carried out. Through comparison between simulation and experiment, some correlation revealed.

  • PDF

A Numerical Study on the Vertical Distribution of PM concentration during Asian Dust

  • Cho, Changbum;Kim, Yoo-Keun;Lim, Yunkyu;Lee, Pyeongkeun;Oh, Sung-Nam
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.51-52
    • /
    • 2003
  • A numerical study on PM using a dispersion and deposition model which can analyze for both quantify and quality would not only offer us to understand our environment more easily, but also make it easy that we can make a plan in order to prevent air pollution. The U.S. EPA has proposed the CALPUFF modeling system as a guideline model for regulatory applications involving long-range transport and on a case-by-case basis for near-field applications where. non- steady- state effects which consider situations such as spatial variability in the meteorological fields, calm winds, fumigations, re-circulation or stagnation, and terrain or coastal effects may be important. (omitted)

  • PDF

The numerical study on relationship between mesoscale circulation and deposition of air pollutant (1) - particle dry deposition according to diameter - (중규모 순환과 입자오염물질의 침적에 관한 수치연구(1) - 입자상 물질의 입경별 침적양 추정 -)

  • 이화운;이순환;반수진
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.399-400
    • /
    • 2002
  • 오염물질의 지표농도 결정에 있어 침적과정은 아주 중요하다. 이전의 연구들에서 가스상 물질 중 특히 SO$_2$의 경우 대기중으로부터 건성침적 과정에 의해서 제거되는 양이 대기로의 총 방출량의 약 1/3배정도 됨을 나타내었다(Arritt et al. 1988; Hicks et al., 1991). 입자상 물질의 침적 역시 오염물질의 장거리 수송의 중요한 부분을 차지하고 있다. 특히 황사기간중의 침적과정은 물질의 국가간이동으로 매우 중요시되면서, 건성침적량 및 영향에 대한 연구가 수행되어져 왔다(Kim et al.,1991). (중략)

  • PDF

Fouling Reduction Characteristics of a Fluidized Bed Heat Exchanger for Flue Gas Heat Recovery (연도가스 열회수용 순환유동층 열교환기의 오염저감특성)

  • 이금배;전용두
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.770-777
    • /
    • 2004
  • Fouling and cleaning tests are performed for a uniquely designed 7,000 ㎉/hr fluidized bed heat exchanger for exhaust gas heat recovery. Fuel rich condition is maintained in the combustor for a limited time period to generate soot that is to be deposited on the heat transfer surfaces (fouling) and 600 Um glass beads are circulated inside the heat exchanger system for cleaning and enhancing the heat transfer performance. According to the present experimental study, performance degradation mode could be monitored and the effect of particle circulation on the heat transfer improvement could be identified. Through the present study, it is demonstrated that circulating particles contribute not only to the fouling reduction in gas side, but also to the heat transfer enhancement of the unit, while other possible aging factors including water side corrosion seemed to contribute to the accumulated performance deterioration.

Image Processing Technique for Rotational Velocity Measurements in a Circular Cylinder (영상처리 기법을 이용한 원통형 용기내의 회전유속의 측정)

  • Kim, J.W.;Eum, C.S.;Lim, T.G.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 1995
  • An experimental investigation has been made for flow in a circular cylinder with a rotating bottom disk. Flow system considered in this paper is a characteristic model of interior flows of an electric washing machine. Flows in a tub of an electric washing machine are driven by a rotating bottom disk called a pulsator. The simple and characteristic model was composed of a circular cylinder with impulsively rotating endwall disk and a viscous fluid in it. Rotational motion of the pulsator is periodic and alternative in rotation direction. The flow field in the interior region is governed by a horizontal boundary layer forms on the impulsively rotating disk. Experimental approach was accomplished by adopting an image processing technique for velocity measurements. Comprehensive details of the flow structure are presented. Also a meridional circulation is obtained by tracking image particles suspended in the fluid. Flow structure and data are successfully procured for this complex rotating flow field.

  • PDF

A Study on Prediction Model of Flow and Heat Transfer in the Circulating Fluidized Bed Heat Exchanger with Multiple Vertical Tubes (다관형 순환유동층 열교환기의 유동 및 전열성능 예측모텔 연구)

  • Park, Sang-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.263-268
    • /
    • 2007
  • The pressure drop and heat transfer coefficient were measured at room temperature in a CFB heat exchanger with multiple vertical tubes. The circulation rate of solid particles was also measured. The theoretical model for predicting heat transfer coefficient using the solid flowrate was developed in this study. The model predictions were compared with the measured heat transfer coefficient to show relatively good agreement.

Flow Analysis of Bubble and Liquid Phase by Vertical Upward Gas Injection (수직상향 기체 주입에 따른 기포 및 액상의 유동분석)

  • 서동표;오율권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.727-732
    • /
    • 2003
  • In the present study, a PIV measurement and image processing technique were applied in order to investigate the flow characteristics in the gas injected liquid bath. The circulation of liquid was induced by upward bubble flow. Due to the centrifugal force, the flow was well developed near both wall sides than in the center of a bath. The vortex flow irregularly repeated generation and disappearance which helped to accelerate the mixing process. The bubble rise velocity in the bottom region was relatively lower than in the upper region because the energy generated by bubbles' behavior in the region near the nozzle was almost converted into kinetic energy But bubble rise velocity increases with the increase of the axial distance since kinetic energy of rising bubbles is added to buoyancy force. In conclusion, the flow increased bubble rise velocity and the flow of the bottom region became more active.

An Experimental Study on the Oil Circulation in an Inverter-Driven Heat Pump (인버터 열펌프내 오일순환량에 관한 실험적 연구)

  • 민만기;홍기수;황윤제;황일남;김철민;조관식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.717-724
    • /
    • 2000
  • It is important to investigate characteristics of flow of refrigerant/oil mixture circulating in a refrigeration system. Therefore the oil concentration in refrigerant/oil mixture should be measured exactly by the adequate measuring instrument. In this paper, the oil concentration was measured by density monitoring system(DMS) in the liquid-line of a inverter-driven heat pump. Experimental result follows ; the main factor that have an effect on oil concentration refrigerant/oil mixture circulating in a refrigeration system is the momentum and kinematic viscosity of refrigerant/oil mixture compressed by scroll compressor.

  • PDF