• Title/Summary/Keyword: air circulation

Search Result 543, Processing Time 0.031 seconds

The Daytime PBL Heating Process and Heating Rate by Meso-Scale Circulation (중규모 순환에 의한 대기경계층 가열과정과 주간 가열율 산정에 관한 연구)

  • 이화운;정우식;김동혁
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.441-442
    • /
    • 2003
  • 복잡한 지형에서 국지적인 순환에 의한 에너지 교환은 기상변화에 중요한 역할을 담당한다. 종관장이 영향이 약하고 양호한 기상조건 하에서 대기 경계층내에서의 온도와 바람장은 국지적인 순환에 영향을 받는다(Kawamura,1979; Kuwagata et al.,1990; Winston et al.,1992). 즉 이러한 기상 조건 하에서는 중규모 순환에 의해 에너지의 수송효과가 크고 각기 수송된 에너지에 의해서 지역별로 대기 경계층내의 가열율에도 차이가 나타난다. (중략)

  • PDF

A study on the design and construction of operating room (병원 수술실 설계 및 시공에 관한 연구)

  • Jung, Eul-Kyu;Oh, Jung-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.103-110
    • /
    • 2003
  • In the early 1990's the clean room system was a new trend of the operating room. This is the concept using in seminconductor plants. That is what the space around the operating table so clean as it remove contaminations with circulation of interior air. These articles describe the standard of interior construction and drawing details.

Study on students과 concepts of evaporation and condensation in elementary school (초등학교 학생들의 증발과 응결 개념에 대한 연구)

  • 이용복;이성미
    • Journal of Korean Elementary Science Education
    • /
    • v.17 no.1
    • /
    • pp.89-103
    • /
    • 1998
  • We study that what kind of the concepts of evaporation and condensation students of elementary school have. The results are following. (1) The students have simple concepts of evaporation on natural circumstance. However, they don't understand about various effect on evaporation. (2) They don't know where the evaporized water is comming from. (3) They have experiences on observing condensation of wale. (70%), however don't know that the water is evaporized in the air. (4) They have more understanding about evaporation, more correct concepts on condensation in circulation of water.

  • PDF

A Study on Prediction Model of Flow and Heat Transfer in the Circulating Fluidized Bed Heat Exchanger with Multiple Vertical Tubes (다관형 순환유동층 열교환기의 유동 및 전열성능 예측모델 연구)

  • Park, Sang-Il
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1199-1204
    • /
    • 2006
  • The pressure drop and heat transfer coefficient were measured at room temperature in CFB heat exchanger with multiple vertical tubes. Also the circulation rate of solid particles was measured. The theoretical model for predicting heat transfer coefficient using the solid flowrate was developed in this study. The model predictions were compared with the measured heat transfer coefficient to show relatively good agreement.

  • PDF

Carbon dioxide (CO2) concentrations and activated carbon fiber filters in passenger vehicles in urban areas of Jeonju, Korea

  • Kim, Hong Gun;Yu, Yunhua;Yang, Xiaoping;Ryu, Seung Kon
    • Carbon letters
    • /
    • v.26
    • /
    • pp.74-80
    • /
    • 2018
  • The South Korean Ministry of the Environment has revised the laws relating to the management of interior air quality for multiple use facilities, and recommends maintaining carbon dioxide ($CO_2$) concentration in passenger vehicles below 1000 ppm during operation in urban areas of large cities. However, the interior $CO_2$ concentration of passenger vehicles can rapidly increase and exceed 5000 ppm within 30 min, as observed when two passengers are traveling in urban areas of the South Korean city of Jeonju with the air conditioner blower turned off and the actuator mode set to internal circulation mode. With four passengers, $CO_2$ concentration can reach up to 6000 ppm within 10 min. To counter this, when the actuator is set to external mode, $CO_2$ concentration can be maintained below 1000 ppm, even after a long period of running time. As part of the air conditioning system, alkali-treated activated carbon fiber filters are considered to be far superior to the commercial non-woven filters or combination filters currently commonly in use.

Flow Visualizations and Hot-Wire Measurements on Air Flow in Two Different Neonate Incubators

  • Kim, Young-Ho;Yoo, Seoung-Chool;Kwon, Chi-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1051-1060
    • /
    • 2001
  • Flow visualizations and hot-wire measurements on the inside flows of two different incubators are presented in this paper. An anatomically-correct neonate model was fabricated using the rapid prototyping machine, based on the 3-D scanned data. The result showed that air flow in the incubator was affected not only by the air circulation system but also by the design of incubator chamber. Large rotating motions were located around the corners of free space. A number of small eddies were found in regions of high shear flow, in areas such as that between the air inlet and the neonate. But, these small eddies were found to be stationary at that locations. Those small eddies might interfere with convective and evaporative heat transfers from the neonate. This study has led to a better understanding of flow mechanism in an incubator chamber and provided the guidance needed for the advancement of improved computational fluid dynamic models.

  • PDF

Thermal Analysis of a Spent Fuel Storage Cask under Normal and Off-Normal Conditions (사용후핵연료 저장용기의 정상 및 비정상조건에 대한 열해석)

  • Ju-Chan Lee;Kyung-Sik Bang;Ki-Seog Seo;Ho-Dong Kim;Byung-Il Choi;Heung-Young Lee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.13-22
    • /
    • 2004
  • This study presents the thermal analyses of a spent fuel dry storage cask under normal and off-normal conditions. The environmental temperature is assumed to be 15 $^{\circ}C$ under the normal condition. The off-normal condition has an environmental temperature of 38 $^{\circ}C$. An additional off-normal condition is considered as a partial blockage of the air inlet ducts. Two of the four air inlet ducts are assumed to be completely blocked. The significant thermal design feature of the storage cask is the air flow path used to remove the decay heat from the spent fuel. Natural circulation of the air inside the cask allows the concrete and fuel cladding temperatures to be maintained below the allowable values. The finite volume computational fluid dynamics code FLUENT was used for the thermal analysis. The maximum temperatures of the fuel rod and concrete overpack were lower than the allowable values under the normal and off-normal conditions.

  • PDF