• Title/Summary/Keyword: air blower

Search Result 237, Processing Time 0.034 seconds

Selection of Centrifugal Fan for Flows with Down-Stream Resistance (유동 저항에 따른 원심홴의 선정)

  • Kim Jae-Won;Jang Dong-Hee;Ahn Eun-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.44-48
    • /
    • 2006
  • Comprehensive experimental works are carried out for the optimal design of a centrifugal blower adopted in an indoor unit of an air-conditioner. The models for consideration are typical multi-blade turbo blower and limit loaded one, respectively. The main interest lies on the fluid dynamics performance when the blower Is installed in the practical system. The methodologies are an experimental estimations with a wind tunnel for blower performance and PIV measurement for the detail flow information. A centrifugal blower with limit loaded fan shows pronounced performances in terms of the flow rate and static pressure rise and the reason is explained by the precise measurement of the flows between blades using PIV. Consequently, it is found that the blower is proper for the flows with a resistance in down stream such as a heat exchanger.

Study on the Noise Characteristic of Centrifugal Fan operating at High Pressure Region (흡입저항이 높은 원심홴 소음특성에 관한 연구)

  • Jung, Yeun-Young;Park, Jin-Won;Jeon, Wan-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1011-1014
    • /
    • 2006
  • Turbo blower generates high peaks when it operates at high pressure region. The fan of the air-cleaner system, operates especially high pressure region due to several filters, generates high noise level. In this case, the tonal sound of BPF makes people annoyance. The blower of air-cleaner has several high resistance filters in its inlet area and rotates above 900rpm Moreover, for the compact design, the size of the blower should be reduced 10%. The reduced diameter of blower makes low flow rate and high noise level. In order to reduce the noise, new blade shape was suggested and optimized

  • PDF

Three phase Switched Reluctance Motor for 200W rated air conditioner blower (에어컨팬용 3상 SRM(200와트급))

  • Lim Jun-young;Kim Sang-young;Choi Yong-won
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.259-259
    • /
    • 2004
  • To date, induction motors have mainly been used for heating, ventilation, and air conditioning (HVAC) applications, however, there is significant research being done world-wide on the use of switched reluctance motor(SRM) in household home appliances. This papers proposes three phase SRM for the air-conditioner blower that has cost merit and good performance respectively compared with conventional induction motor.

  • PDF

The Numerical Simulation of Fluid Flow in an Automotive HVAC module by using Commercial Code (상업용 코드를 이용한 차량용 HVAC module의 유동에 관한 전산모사)

  • KIM H. B.;HONG S. R.;CHUNG D. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.194-199
    • /
    • 2003
  • The studying is to analyze characteristic of air flow and is used to design in an automotive HVAC module. The RNG k-e turbulence model with the Upwind Difference convection scheme and an unstructured hybrid mesh with arbitrary matching method were applied to the simulation. The comparing air flow characteristic of the basic HVAC module and total HVAC module with blower were discussed in the paper.

  • PDF

Study on Characteristics of Performance according to Backward and Forward Blades in Centrifugal Blower (원심형 송풍기에 있어서 전향익과 후향익에 따른 성능 특성에 관한 연구)

  • Kim J. W;Park J. W
    • Journal of computational fluids engineering
    • /
    • v.9 no.1
    • /
    • pp.10-17
    • /
    • 2004
  • Comprehensive investigation according to the two kinds of blades is systematically carried out for a design of the centrifugal blower. The motivation of this work is due to demand of enhanced flow rate with higher inlet pressure, such as air purifiers adopting several filters. It is observed that flow rate of the blower with forward blades is larger than that of the system with backward blades. The reason is due to larger outlet velocity from the rotating forward blades and the tendency is validated by a parallel experiment with a wind tunnel. Numerical analysis for the blower system shows detail information between the blades and inside the casing. A series of figures to show the flow details offers deep understanding of a centrifugal blower with the two different blades.

Study on Difference of Characteristics between Backward and Forward Blades in Centrifugal Blower (원심형 송풍기에 있어서 전향익과 후향익의 특성 차이에 관한 연구)

  • Kim J. W.;Park J. W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.165-170
    • /
    • 2003
  • Centrifugal blowers are widely used for air handling units in industry applications. The blower has a centrifugal impeller and a scroll casing including a driving component such as an electric motor. The impeller takes forward or backward blades to induce flows into the blower. Comprehensive investigation according to the two kinds of blades is systematically carried out for a guidance of design. It is observed that flow rate of the blower with forward blades is larger than that of the system with backward blades. The reason is due to larger velocity from the rotating forward blades and the tendency is validated by a parallel experiment with a wind tunnel. Numerical analysis for the system shows detail information inside the blades and the casing. A series of figures to show the flow details offers deep understanding of a centrifugal blower with different blades.

  • PDF

Development of the Inverter System with UPS Function for the Air-Conditioning Blower (UPS 기능을 갖는 A/C Blower용 Inverter 시스템 개발)

  • Lim, Seung-Beom;Lee, Yun-Ha;Ji, Jun-Keun;Mok, Hyung-Soo;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.345-346
    • /
    • 2010
  • The HVAC(Heating Ventilation and Air Conditioning) system is only controlled by turn on/turn off operations against to AC 380V input. Therefore, the efficiency of the system is reduced and noise occurs. Also, the blower is shut down at the AC power failure. In this paper, the inverter system with UPS function for the A/C(Air Conditioning) blower is proposed. Proposed inverter system which is powered from the AC and DC voltage can control speed, operation mode, and soft-start time using CAN communication. In case of the CAN communication failure, RS-232 communication could be used to control the hardware directly by the engineer that can solve existing problems. To verify the validity of proposed inverter system, simulations and experiments are carried out.

  • PDF

On the Passive type Anti-Rolling Tank and its Activation by Air Blower

  • Lew, Jae-Moon;Park, Bong-Joon;Kim, Hyo-Chul
    • Journal of Ship and Ocean Technology
    • /
    • v.7 no.1
    • /
    • pp.19-28
    • /
    • 2003
  • The systematic results of anti-rolling tanks tests obtained by bench tester and roll test in towing tank have been examined. The effects on the oscillating period of fluid transfer through the duct of U-tube tank due to damper plates and the effects on roll damping moment of the tank due to swash plates are alto evaluated from the results. A simple control algorithm for a forced fluid transfer in U-tube tanks if devised to active operation of the tank by air blower. The active performances of the tank are confirmed very effective through the tank tests carried out in the irregular waves.

Study of Pre-ventilation Effects on the Cabin Thermal Load (주차환기 시스템이 차 실내 열부하에 미치는 영향에 관한 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.5
    • /
    • pp.84-90
    • /
    • 2014
  • The aim of this paper is to investigate the application of solar energy in reducing cabin thermal load. When a vehicle is parked under the sun in summer, the interior temperature can reach up to $70^{\circ}C$ depending on the solar intensity. Solar power, one of the green energies, is used in automobile air conditioning systems, in order to operate the blower. The power supply of a blower's voltage has been used in a solar sunroof experiment. At the climate wind tunnel, cabin temperature changes were conducted with various operating modes of an air handling system and the preventilation parking conditions of several vehicles, outdoors, was also examined. The test results of the solar sunroof, 39.3W power and 14.1% efficiency were obtained. The thermal load behavior was analysed with the air handling system operating mode differently according to the cabin temperature. By simply operating the blower, average cabin temperature decreased between $5^{\circ}C{\sim}10^{\circ}C$ in those vehicles parked outdoors in summer. This reveals that cabin thermal comfort can be improved without consuming the vehicle's extra energy, and that the performance of the air-conditioning system is better than those currently found in vehicles. Moreover, fuel economy will be increased as a result of the reduction in the use of the air-conditioning system, and many other human advantages will be gained. Such advantages include minimized VOCs and a healthy cabin environment.

Design and Operation Characteristics of Novel 2-Phase 6/5 Switched Reluctance Motor

  • Hieu, Pham Trung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2194-2200
    • /
    • 2014
  • This paper presents a design of novel 2-phase 6/5 switched reluctance motor (SRM) for an air-blower application. This type of motor is suitable for the applications that require high speed and only one directional rotation as air-blower. The desired air-blower is unidirectional application, and requires a wide positive torque region without torque dead-zone. In order to get a wide positive torque region without torque dead-zone during phase commutation, asymmetric inductance characteristic with non-uniform air-gap is considered. The proposed motor can be operated at any rotor position. The proposed 6/5 SRM uses short flux path technique that achieved by means of winding configuration and lamination geometry. The purpose of short flux path is to reduce the core loss and the absorption MMF in the stator. The proposed 2-phase 6/5 SRM is verified by finite element method (FEM) analysis and Matlab-Simulink. In order to verify the design, a prototype of the proposed motor was manufactured for practical system.