• Title/Summary/Keyword: aim of experiment

Search Result 927, Processing Time 0.027 seconds

Rheological properties of arabinogalactan solutions isolated from the legumes (콩류 아라비노갈락탄 용액의 유변학적 성질)

  • Kim, Kyeong Yee;Kim, Choon Young
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.330-335
    • /
    • 2019
  • The aim of this study was to investigate the rheological properties of arabinogalactans (AGs) solution isolated from moth bean (MB), navy bean (NB), and soybean (SB) including monosaccharide compositions, intrinsic viscosity, steady shear and dynamic shear rheological properties. The major monosaccharides in MB, NB, and SB were arabinose (64.8, 51.4, and 42.6%) and galactose (13.4, 19.6, and 46.2%). The yield stresses for 5% (w/v) NB and 2.5% (w/v) SB solutions were assessed as 2.10 Pa and 1.98 Pa, respectively, but in case of MB solution, it was observed to be negligible. While 5% MB solution showed rheopectic property, 5% NB and SB solutions showed thixotropic properties. As a result of frequency sweep experiment, the G' values in 2.5% MB and NB were larger than the G" value showed but 2.5% SB exhibited G" value greater than G'. These results would be useful for future application as a food additive in the food industry.

Development Status of Technology Demonstration Model for Staged Combustion Cycle Engine (다단연소사이클 엔진 기술검증시제 개발 현황)

  • Kim, Chaehyoung;Lee, Jungho;Woo, Seongphil;So, Younseok;Yi, SeungJae;Lee, Kwang-Jin;Cho, Namkyung;Han, Yeoungmin;Kim, Jin-han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.104-111
    • /
    • 2019
  • Staged combustion cycle engines exhibit higher combustion performance compared with open cycle engines with a gas generator. An advanced research of the staged combustion cycle engine is going on for the next program following the KSLV-II program. Various experiments have been carried out for the technology demonstration model, TDM0A and TDM0B. The experiments on the combustion performance are aimed to understand the engine start condition and combustion characteristics. They also aim to develop the oxidizer-rich pre-burner and the combustor of the staged combustion cycle engine. The engine-shaped model, TDM1A is fabricated based on the experimental data. The combustion experiment of the TDM1A shows that the combustion pressure of the combustor is approximately 91 bar and the turbine rotation is approximately 28,00 rpm. The result is stable and satisfies the development requirements. The present paper reports on the development process and characteristics of engine models from TDM0A to TDM1A.

Preliminary Study of a New Extracorporeal Membrane Oxygenator Development When Using Pulsatile Flow

  • Lee, Sa-Ram;Lee, Kyung-Soo;Jung, Jae-Hoon;Mun, Cho-Hay;Min, Byoug-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.387-391
    • /
    • 2007
  • An oxygenator is a very important artificial organ and widely used for patients with lung failure or during open heart surgery. Although an oxygenator has been widely studied worldwide to enhance its efficiency, studies on oxygenators, in particular when using a pulsatile blood flow, are domestically limited. Therefore, a new oxygenator was developed in the lab and animal experimental results are described in the paper. The oxygenator is composed of polycarbonate housing and polypropylene hollow fibers. It has a total length of 400 mm and a surface area of $1.7 m^2$. The animal experiment lasted for 4 hours. The blood flow rate was set to 2 L/min and a pulsatile blood pump, T-PLS (Twin-Pulse Life Support), was used. Samples were drawn at the oxygenator's inlet and outlet. The total hemoglobin (Hb), saturation oxygen ($sO_2$), and partial oxygen pressure ($pO_2$), partial $CO_2$ pressure ($pCO_2$), and plasma bicarbonate ion concentration ($HCO_3^-$) were measured. The oxygen and carbon dioxide transfer rates were also calculated based on the experimental data in order to estimate the oxygenator's gas transfer efficiency. The oxygen and carbon dioxide transfer rates were $16.4{\pm}1.58$ and $165.7{\pm}10.96 mL/min$, respectively. The results showed a higher carbon dioxide transfer rate was achieved with the oxygenator. Also, the mean inlet and outlet blood pressures were 162.79 and 137.92 mmHg, respectively. The oxygenator has a low pressure drop between its inlet and outlet. The aim of own preliminary study was to make a new oxygenator and review its performance when applying a pulsatile blood pump thus, confirming the possibility of a new oxygenator suitable for pulsatile flow.

3D Stereoscopic Image Generation of a 2D Medical Image (2D 의료영상의 3차원 입체영상 생성)

  • Kim, Man-Bae;Jang, Seong-Eun;Lee, Woo-Keun;Choi, Chang-Yeol
    • Journal of Broadcast Engineering
    • /
    • v.15 no.6
    • /
    • pp.723-730
    • /
    • 2010
  • Recently, diverse 3D image processing technologies have been applied in industries. Among them, stereoscopic conversion is a technology to generate a stereoscopic image from a conventional 2D image. The technology can be applied to movie and broadcasting contents and the viewer can watch 3D stereoscopic contents. Further the stereoscopic conversion is required to be applied to other fields. Following such trend, the aim of this paper is to apply the stereoscopic conversion to medical fields. The medical images can deliver more detailed 3D information with a stereoscopic image compared with a 2D plane image. This paper presents a novel methodology for converting a 2D medical image into a 3D stereoscopic image. For this, mean shift segmentation, edge detection, intensity analysis, etc are utilized to generate a final depth map. From an image and the depth map, left and right images are constructed. In the experiment, the proposed method is performed on a medical image such as CT (Computed Tomograpy). The stereoscopic image displayed on a 3D monitor shows a satisfactory performance.

Phosphate sorption to quintinite in aqueous solutions: Kinetic, thermodynamic and equilibrium analyses

  • Kim, Jae-Hyun;Park, Jeong-Ann;Kang, Jin-Kyu;Kim, Song-Bae;Lee, Chang-Gu;Lee, Sang-Hyup;Choi, Jae-Woo
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • The aim of this study was to examine the phosphate (P) removal by quintinite from aqueous solutions. Batch experiments were performed to examine the effects of reaction time, temperature, initial phosphate concentration, initial solution pH and stream water on the phosphate adsorption to quintinite. Kinetic, thermodynamic and equilibrium isotherm models were used to analyze the experimental data. Results showed that the maximum P adsorption capacity was 4.77 mgP/g under given conditions (initial P concentration = 2-20 mgP/L; adsorbent dose = 1.2 g/L; reaction time = 4 hr). Kinetic model analysis showed that the pseudo second-order model was the most suitable for describing the kinetic data. Thermodynamic analysis indicated that phosphate sorption to quintinite increased with increasing temperature from 15 to $45^{\circ}C$, indicating the spontaneous and endothermic nature of sorption process (${\Delta}H^0=487.08\;kJ/mol$; ${\Delta}S^0=1,696.12\;J/(K{\cdot}mol)$; ${\Delta}G^0=-1.67$ to -52.56 kJ/mol). Equilibrium isotherm analysis demonstrated that both Freundlich and Redlich-Peterson models were suitable for describing the equilibrium data. In the pH experiments, the phosphate adsorption to quintinite was not varied at pH 3.0-7.1 (1.50-1.55 mgP/g) but decreased considerably at a highly alkaline solution (0.70 mgP/g at pH 11.0). Results also indicated that under given conditions (initial P concentration=2 mgP/L; adsorbent dose=0.8 g/L; reaction time=4 hr), phosphate removal in the stream water (1.88 mgP/g) was lower than that in the synthetic solution (2.07 mgP/g), possibly due to the presence of anions such as (bi)carbonate and sulfate in the stream water.

Degenerative Changes of the Rat Dorsal Root Ganglion (DRG) Cells Following a Tight Spinal Nerve Ligation (랫드 척수신경 결찰에 따른 척수신경절세포의 퇴행성변화)

  • Kim, Yi-Suk;Jo, Seung-Mook
    • Applied Microscopy
    • /
    • v.39 no.3
    • /
    • pp.261-266
    • /
    • 2009
  • This study aim to disclose a possible mechanism for the neuronal cell death induced by peripheral nerve injury following a spinal nerve ligation (SNL) as a neuropathic pain model. Male Sprague-Dawley rats (270~290 g) were used for this study. Pain threshold was evaluated for their response to mechanical (von Frey hairs) stimuli 1, 3, and 7 days after a tight ligation of L5 ventral ramus. In control group, the small ganglion cells were strongly stained with routine toluidine blue (TB), whereas the large ganglion cells showed a little bit weak stainity. Each large ganglion cell is surrounded by perineuronal satellite cells. In experimental groups, small ganglion cells showing apparent degenerative changes increased on 1 day, and showed a peak in degenerative cell number at 3 days group, and decreased gradually at 7 days group. We also found a small number of large-sized ganglion cells showing mild degenerative changes. However their satellite cells ware relatively intact with no typical findings throughout this experiment. Under the electron microscope, small ganglion cells showed various stage and typical features of the dark degeneration including mitochondrial swelling.

Study on low-level laser therapy device according to the obesity development (비만치료기 개발에 따른 저준위레이저에 관한 연구)

  • Lee, Sang-sik;Kim, Jun-tae;Jeong, Jin-hyoung;Kim, Nam-Sun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.1
    • /
    • pp.82-89
    • /
    • 2016
  • And by entering into an aging society with economic growth "beautiful and healthy desire to live', aesthetics industry as promote interest in 'Anti-aging' is emerging as a promising business increased significantly the skin care market. However, the management of the hospital or the temporal order to receive professional care providers, spatial, and cost constraints caused many companies to solve this problem began to approach the Home Care Area. Global trends in personal skin care market has been activated, the domestic has been activated at low cost, private market due to the recession. We have performed this test in order to develop a skin care device for home in order to compensate for this point.In this paper, we develop a low-level laser to create a personal skin care products and sought to incorporate them into the skin cosmetic.Expand the pores by using the low-level laser to the skin by to the dermal layer of the skin was penetrated aim experiment the ampoule, and by a comparison of the medical low-level laser reliability and determine the effectiveness or absence of the performance and efforts to commercialize.

Experimental Evaluation and Flexible Performance Improvement of IoT Middleware for Efficient Connectivity (사물간의 효율적인 연결을 위한 사물인터넷 미들웨어 실험 평가 및 성능 향상 방법)

  • Jeon, Soo Bin;Lee, Chung San;Han, Young Tak;Jung, In Bum
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.9
    • /
    • pp.385-396
    • /
    • 2017
  • Many IoT platforms have been proposed for various IoT devices, from low-end to high-end performance. We previously proposed a new IoT platform called MinT that supports the operation of the sensing devices and network communication. In the proposed platform, the things can flexibly connect to each other and efficiently share their information. Most IoT platforms, including the MinT, support thread pooling to quickly process requests. However, using a thread pool with a fixed thread count can cause network delay and inefficient energy consumption. In this paper, we propose an enhanced method to manage the thread pool efficiently by adjusting the number of threads every cycle to regulate the device's performance. In particular, we aim to improve the performance of the Interaction Thread Pool Group, which is responsible for analyzing, processing, and re-transmitting the received packets. The experiment shows that the improved method increases the average throughput by approximately 25% compared to the existing platforms. Finally, using the proposed method, the MinT can reduce the transmission delay and energy consumption of devices in the IoT environment.

A Systematic Review on the Association between Cognitive Function and Upper Extremity Function in the Elderly (노인의 인지기능과 상지기능의 관련성에 관한 체계적 고찰)

  • Moon, Mi-Sook;Jung, Min-Ye
    • Therapeutic Science for Rehabilitation
    • /
    • v.5 no.2
    • /
    • pp.23-33
    • /
    • 2016
  • Objectives: The aim of this study was to investigate the association between cognitive function and upper extremity function in the elderly. The articles were analyzed based on patient, intervention, comparison, and outcome using the P.I.C.O. principle. Methods: We systematically examined papers from January, 2000 to November, 2015 published papers through the foreign journals which were Medline & Pubmed for three months. mainly used key words were elderly, dementia, Alzheimer's disease, Mild cognitive impairment, age-related, aging, cognitive, upper extremity function, hand function, hand-grip strength, grip force, complex motor function, bimanual, dexterity, UE performance, and coordination. Results: The number of discovered outcomes for association between cognitive function and upper extremity function in the elderly was 7; grip strength & sex are impact on manipulation object, 1. The results show that cognitive function is associated with upper extremity function in the elderly. Conclusion: This study is expected to help selecting intervention, assessment tools according to the individual's degree of cognitive level and upper extremity function. In future domestic research, variety assessment tools need to be used and more qualitative level experiment will be carried out.

A hybrid algorithm for the synthesis of computer-generated holograms

  • Nguyen The Anh;An Jun Won;Choe Jae Gwang;Kim Nam
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.60-61
    • /
    • 2003
  • A new approach to reduce the computation time of genetic algorithm (GA) for making binary phase holograms is described. Synthesized holograms having diffraction efficiency of 75.8% and uniformity of 5.8% are proven in computer simulation and experimentally demonstrated. Recently, computer-generated holograms (CGHs) having high diffraction efficiency and flexibility of design have been widely developed in many applications such as optical information processing, optical computing, optical interconnection, etc. Among proposed optimization methods, GA has become popular due to its capability of reaching nearly global. However, there exits a drawback to consider when we use the genetic algorithm. It is the large amount of computation time to construct desired holograms. One of the major reasons that the GA' s operation may be time intensive results from the expense of computing the cost function that must Fourier transform the parameters encoded on the hologram into the fitness value. In trying to remedy this drawback, Artificial Neural Network (ANN) has been put forward, allowing CGHs to be created easily and quickly (1), but the quality of reconstructed images is not high enough to use in applications of high preciseness. For that, we are in attempt to find a new approach of combiningthe good properties and performance of both the GA and ANN to make CGHs of high diffraction efficiency in a short time. The optimization of CGH using the genetic algorithm is merely a process of iteration, including selection, crossover, and mutation operators [2]. It is worth noting that the evaluation of the cost function with the aim of selecting better holograms plays an important role in the implementation of the GA. However, this evaluation process wastes much time for Fourier transforming the encoded parameters on the hologram into the value to be solved. Depending on the speed of computer, this process can even last up to ten minutes. It will be more effective if instead of merely generating random holograms in the initial process, a set of approximately desired holograms is employed. By doing so, the initial population will contain less trial holograms equivalent to the reduction of the computation time of GA's. Accordingly, a hybrid algorithm that utilizes a trained neural network to initiate the GA's procedure is proposed. Consequently, the initial population contains less random holograms and is compensated by approximately desired holograms. Figure 1 is the flowchart of the hybrid algorithm in comparison with the classical GA. The procedure of synthesizing a hologram on computer is divided into two steps. First the simulation of holograms based on ANN method [1] to acquire approximately desired holograms is carried. With a teaching data set of 9 characters obtained from the classical GA, the number of layer is 3, the number of hidden node is 100, learning rate is 0.3, and momentum is 0.5, the artificial neural network trained enables us to attain the approximately desired holograms, which are fairly good agreement with what we suggested in the theory. The second step, effect of several parameters on the operation of the hybrid algorithm is investigated. In principle, the operation of the hybrid algorithm and GA are the same except the modification of the initial step. Hence, the verified results in Ref [2] of the parameters such as the probability of crossover and mutation, the tournament size, and the crossover block size are remained unchanged, beside of the reduced population size. The reconstructed image of 76.4% diffraction efficiency and 5.4% uniformity is achieved when the population size is 30, the iteration number is 2000, the probability of crossover is 0.75, and the probability of mutation is 0.001. A comparison between the hybrid algorithm and GA in term of diffraction efficiency and computation time is also evaluated as shown in Fig. 2. With a 66.7% reduction in computation time and a 2% increase in diffraction efficiency compared to the GA method, the hybrid algorithm demonstrates its efficient performance. In the optical experiment, the phase holograms were displayed on a programmable phase modulator (model XGA). Figures 3 are pictures of diffracted patterns of the letter "0" from the holograms generated using the hybrid algorithm. Diffraction efficiency of 75.8% and uniformity of 5.8% are measured. We see that the simulation and experiment results are fairly good agreement with each other. In this paper, Genetic Algorithm and Neural Network have been successfully combined in designing CGHs. This method gives a significant reduction in computation time compared to the GA method while still allowing holograms of high diffraction efficiency and uniformity to be achieved. This work was supported by No.mOl-2001-000-00324-0 (2002)) from the Korea Science & Engineering Foundation.

  • PDF