• 제목/요약/키워드: aging point

검색결과 370건 처리시간 0.029초

국내 안경 디자인산업 현황에 관한 연구 (A Study on the Current Status of the Glasses Design Industry in Korea)

  • 윤을요
    • 한국의상디자인학회지
    • /
    • 제15권3호
    • /
    • pp.199-211
    • /
    • 2013
  • Glasses industry has great growth potential from the future-oriented perspective in Korea. In consideration of the fact that the ratio of aging population increases in this aging society, people have more and more interest in health. Also, their recognition on the cycle to change glasses is changing, and the utility of them as fashion items is increasing day by day, it is expected that the demand for glasses will be even more extended afterwards. Of course, presently it suffers from the gap between cheaper items and expensive ones provided by overseas prominent brands due to the bi-polarization of the market. However, they are pursuing the 2nd growth as export-leading items in the past through international glass exhibitions based on knowhow accumulated for a long time. Therefore, this study aims to examine the current status of glasses design industry in Korea reflecting the actual situations we have now and also understand the problems and limitations internalized in our glass design industry through the research process. As a result, the study has drawn the following conclusions. This paper intends to point out first, the phenomenon of bi-polarization of the glass market in Korea. Second, unequal distribution by region centering around Daegu. Third, the limitations of brand identity. Fourth, the limitations of information, planning, and marketing power. Fifth, passive conduction of international events and their insufficient effects. This study concludes that all these problems can be solved through 'planning and design, and marketing power'.

  • PDF

Thermal Characteristics of Rotating Anode X-ray Tube with Emissivity in Aging Process for Digital Radiography

  • Lee, Seok Moon
    • Applied Science and Convergence Technology
    • /
    • 제24권5호
    • /
    • pp.125-131
    • /
    • 2015
  • We investigated the thermal characteristics of rotating anode X-ray tube to develop it for digital radiography by using computer simulation. The target which is the area of the anode struck by electrons is the most important component to get a long life of X-ray tube. So we analyze the thermal characteristics of the target and rotor assembly according to their emissivity by using ANSYS transient thermal simulation and then compare with the measured data of the target temperature operating in aging process of X-ray tube. Especially, keeping the lead coated layer as the role of metal lubricant on ball bearing enables to prevent the noise in rotating anode. The simulation result showed that its temperature was under the melting point of the lead in X-ray tube for digital radiography with 1.2 mm large focal spot 0.6 mm small focal spot and 150 kV tube voltage. We also investigated the relationship between the diameter of the anode shaft and the temperature of the anode and rotor assembly. It has been confirmed that the smaller anode shaft could be good for the rotor thermal characteristics.

원전 배관감육 평가를 위한 새로운 기법의 도입 및 타당성 (Introduction and Feasibility on a New Technology for the Pipe Wall Thinning Evaluation of Nuclear Power Plants)

  • 황경모;윤훈;박현철
    • Corrosion Science and Technology
    • /
    • 제13권2호
    • /
    • pp.62-69
    • /
    • 2014
  • A huge number of carbon steel piping components installed in the secondary system of nuclear power plants are exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), Cavitation, Flashing, and LDIE (Liquid Droplet Impingement Erosion). Those aging mechanisms can lead to thinning of the piping components. To manage the wall thinning degradation, most of utilities in the world predict the wall thinning rate based on the computational program such as CHECWORKS, COMSY, and BRT-CICERO, evaluate the UT (Ultrasonic Test) data, and determine next inspection timing, repair or replacement, if needed. There are several evaluation methods, such as band, blanket, and strip methods, commonly used for determining the wear of piping components from single UT inspection data. It has been identified that those single UT evaluation methods not only do not consider the manufacturing features of pipes, but also may exclude the data of the most thinned point when determining the representative wear rate of piping components. This paper describes a newly developed single UT evaluation method, E-Cross method, for solving above problems and introduces application examples for several pipes and elbows. It was identified that the E-Cross method using the length and width of UT data excluded the most thinned points appropriate as the single UT evaluation method for thinned piping components.

주증기계통 오리피스 후단 소구경 배관의 감육 및 누설 발생 (Cause Analysis for the Wall Thinning and Leakage of a Small Bore Piping Downstream of an Orifice)

  • 황경모
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.227-232
    • /
    • 2013
  • A number of components installed in the secondary system of nuclear power plants are exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), Cavitation, Flashing, and LDIE (Liquid Droplet Impingement Erosion). Those aging mechanisms can lead to thinning of the components. In April 2013, one (1) inch small bore piping branched from the main steam line experienced leakage resulting from wall thinning in a 1,000 MWe Korean PWR nuclear power plant. During the normal operation, extracted steam from the main steam line goes to condenser through the small bore piping. The leak occurred in the downstream of an orifice. A control valve with vertical flow path was placed on in front of the orifice. This paper deals with UT (Ultrasonic Test) thickness data, SEM images, and numerical simulation results in order to analyze the extent of damage and the cause of leakage in the small bore piping. As a result, it is concluded that the main cause of the small bore pipe wall thinning is liquid droplet impingement erosion. Moreover, it is observed that the leak occurred at the reattachment point of the vortex flow in the downstream side of the orifice.

전력케이블 열화진단을 위한 극저주파 탄델타 판정기준의 통계적 해석 (A Statistical Analysis to the VLF Tanδ Criteria for Aging Diagnosis in Power Cables)

  • 정우성;김성민;임장섭;이진
    • 한국전기전자재료학회논문지
    • /
    • 제33권1호
    • /
    • pp.1-5
    • /
    • 2020
  • In this study, the objective is to improve the criteria used for statistical comparison of the VLF tanδ (TD) database and failure rate according to water-tree degradation in underground distribution power cables. The aging condition of the KEPCO criteria is divided into 6 levels using the Weibull distribution, and the "failure imminent" condition is quantified by using the statistical end-point of the lifetime parameter of the VLF big-data group obtained from KEPCO. Moreover, new criteria with a 2-dimensional combination of TD, DTD, and a statistical normalized factor are suggested. These criteria exhibit high reproducibility for the detection of cables in an imminent failure state. Consequently, it is expected that the adoption of the extended VLF-2019 criteria will reduce the asset management cost of cable replacement compared to the VLF-2012 criteria of KEPCO.

마을회관 유형 분류에 관한 연구 (A Study on the Classification of Type for the Village Community Center)

  • 신영선;강영은;오동엽;지달님;임승빈
    • 농촌계획
    • /
    • 제14권3호
    • /
    • pp.75-87
    • /
    • 2008
  • Changes in society organization of rural villages in our country are caused by aging society and lessening of economic activity population aggravates the economy of rural villages. With this, it joins in with the aging of village community center, the representative center space of the rural village and therefore, it is a point of view where the change is necessary in the size and the side of function. The research which it sees is made on-the-spot inspection and literature investigation compensate in behalf of 25 administrative village community centers led in the object by grasping present status and drew up the layout sketches and plane surface degrees of the village community centers. By referring to the photographs and the topographical maps taken in the spot, it was able to divide the village community centers into side of arrangement, side of plane surface and side of form and managed to seize the characters, problems and improvable directions of each of them. The research result could be used as a guidable provision and be applied in the fundamental research in developing model of village community centers during space planning in the future.

Accelerating Aging of Transmission Line Porcelain Suspension Insulators by Autoclaving

  • Lee, Won-Kyo;Choi, In-Hyuk;Shin, Koo-Yong;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권4호
    • /
    • pp.147-150
    • /
    • 2008
  • Porcelain suspension insulators aged for 1, 5 and 10 years on Korean transmission lines and new insulators are tested for autoclave expansion. The compressive strength of the insulators aged in an autoclave with conditions of $250\;^{\circ}C$ and at 20 atm for 30 minutes, was about $7.6\;kgf/mm^2$, which is close to that measured on insulators aged for 10 years in the field. From simulation results, the cement displacement changed linearly with temperature. At a temperature of $200\;^{\circ}C$, the shear stress was approximately $7\;kgf/mm^2$; a stress that is brought about by a 0.07 % expansion of the cement. It is evident that the cement would fracture at a 0.07 % expansion, because the cement has about 7 to $9\;kgf/mm^2$ flexure strength. A turning point in the shear stress with mechanical load occurred at 0.02 % cement expansion. From an analysis of the porcelain body it is shown that there is sufficient margin of strength to guard against fracture of the porcelain body even for a cement expansion more than 0.12 %.

Biological Control Strategy of Uzi Fly in Sericulture

  • Singh, R.N.;Saratchandra, Beera
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제6권2호
    • /
    • pp.125-132
    • /
    • 2003
  • Uzi fly (Exorista bombycis Louis) is one of the major larval endo-parasitoid of silkworm (Bombyx mori). It causes extensive damage to sericulture industry. The application of synthetic organic pesticides has tremendous impact on minimizing pest population but their overuse and frequent misuse and high sensitivity towards the silkworms, has forced the entomologists to search for alternatives to chemical control, which is safe to silkworm, environment and farm workers. Biological control continues to offer exciting possibilities for the control of fly pest population. It is environmentally safe alternative to chemical control and offering a long-term protection. Several potential hymenopteran parasitoids have been screened. Among successful natural enemies, Nesolynx thymus, Trichomalopsis apanteloctena, Trichopria sp., Brachymeria lasus, Pediobius sp., Spalangia sp., Spilomicrus karnatakensis and Dhirhinus sp. are important. It is essential to predict accurately the efficacy of these natural enemies in a new habitat prior to its introduction. The important desirable attributes of these potential parasitoids viz., host searching capacity, specificity, power of increase and fitness and adaptability of the parasitoid in new environment has been recorded. Results of the host parasitoid interaction indicate that the aging of the host function as a factor that influence the host finding efficiency of the parasitoid. It is highly scored with 15-20 hrs old pupa of the host. However, aging of the parasitoid does not significantly affect it. The sex ratio is female biased which is advantageous from biological control point of view, Biological suppression methods involving conservation and utilization of natural enemies have been discussed in detail.

전력용 피뢰기의 열안정화 특성 (Study on Thermal Stability Characteristics of Surge Arrester for High Power)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1142-1145
    • /
    • 2004
  • ZnO surge arresters continuously endure the operating voltages during the operation course, and in the mean time, which need to withstand occasionally transient voltages of lightning and switching overvoltages. Under these voltages, the ZnO varistors inside arresters would have aging phenomena, one important result of aging phenomena is the increasing of resistive currents of varistors, which leads to the increasing of power losses of varistors. And the operating voltage is continuously applied on the ZnO varistors, there is a degradation phenomenon existing in ZnO varistors. When the degradation reaches a certain degree, then the arrester must stop operation. The degradation is related to the applied voltage ratio, the applied voltage ratio is high, the degradation is quickly. When the power loss is higher than the thermal dispersion ability of house of arrester, then the arrester will thermally breakdown. In this study the thermal stability characteristics of surge arresters for high power wil be discussed on the view point of watt losses and thermal breakdown.

  • PDF

전력설비의 열화 진단을 위한 연면방전 모델에서의 코로나 방전 특성 분석 (The Analysis of Corona Discharge of Surface Flashover Model for Aging Diagnosis of Power Facility)

  • 방만식;최재형;김우진;김영석;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제24권4호
    • /
    • pp.314-318
    • /
    • 2011
  • Recently, ultrasound, infrared detector, V-I characteristic, gas analysis, UV (ultra-violet rays) camera etc. is used as inspections and diagnoses of the safety of power equipment. Especially, UV camera have attracted a great deal of interest from the view point of easy judgement. UV camera is used corona discharge. One of the most important and difficult problems to be solved filer design, materials and corona discharge. This paper is studied on the temperature characteristics, UV generation and shape analysis and corona pulse count according to the electrode distance and applied voltage. Also, Corona discharge characteristics in air are analyzed using prototype UV camera of Korea. UV generation due to surface discharge of AC is higher than that of DC.