• Title/Summary/Keyword: aggregate structures

Search Result 346, Processing Time 0.025 seconds

A Study on Electromagnetic Properties in OPC Mortar with Different Chloride Content (염화물을 혼입한 OPC 모르타르의 전자기 특성에 대한 연구)

  • Kwon, Seung-Jun;Na, Ung-Jin;Feng, M.Q.
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.565-571
    • /
    • 2008
  • Recently, the evaluation technique using NDT (Nondestructive Technique : NDT) is widely utilized because it makes little damage on RC (Reinforced Concrete : RC) structures. The techniques using electromagnetic properties (EM properties) are also attempted for the evaluation of the performance of concrete which is nonmetallic. For the economic manufacturing of concrete material, sea-sand is often used as aggregate, however, chloride ion in concrete has direct effects on steel corrosion and EM properties. In this study, OPC mortar specimens with 5 different chloride amount (0.0, 0.6, 1.2, 2.4, and $3.6kg/m^3$) and 3 different water-cement ratios (45%, 55%, and 65%) are prepared in order to investigate the EM properties corresponding to concrete properties. The EM properties of conductivity and dielectric constant are measured in the frequency range over 0.2~20 GHz. To facilitate the comparison of EM properties with chloride content, average values are taken respectively for the conductivity and dielectric constant measured over the 5~20 GHz frequency range. According to the results of this experiment, dielectric constant and conductivity are increased with lower W/C ratio and larger amount of chloride content.

Experimental Studies on Influence of Foaming Agents on the Properties of Mortar (기포제가 모르터의 제성질에 미치는 영향에 관한 실험적 연구)

  • Sung, Chan-Yong;Hwang, Eun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.27 no.1
    • /
    • pp.46-61
    • /
    • 1985
  • This study was performed to obtain the basic data which can be applied to the use of foaming mortars. The data was based on the properties of foaming mortars depending upon various mixing ratios and addings to compare those of cement mortar. The foaming agents which was used at this experiment were pre-foamed type and mix-foaming type which is being used as mortar structures. The foaming mortar, mixing ratios of cement to fine aggregate were 1:1, 1: 2, 1 : 3 and 1 : 4. The addings of foaming agents were 0.0%, 0.5%, 1.0%, 1.5%, 2.0%, 2.5% and 3.0% of cement weight. The results obtained were summarized as follows; 1. At the mixing ratio of 1 : 1, the lowest water-cement ratios were showed by foaming mortars, respectively. But it gradually was increased in poorer mixing ratio and decreased in more addition of foaming agent. The water-cement ratios were decreased up to 1. 8~22. 0% by G, 2. 2~24. 1 % by U and 0. 7~53. 1% by J foaming mortar than cement mortar. 2, At the mixing ratio of 1 : 1, the highest bulk densities were showed by foaming mortars, respectively. But, it gradually was decreased in poorer mixing ratio and more addition of foaming agent. The bulk densities were decreased up to 1. 4~20. 7% by G, 2. 3~23. 7% by U and 26. 5~56. 5% by J foaming mortar than cement mortar. Therefore, foaming mortar could be utilized to the constructions which need low strengths. 3. At the mixing ratio of 1:1, the lowest absorption rates were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. Specially, according to the absorption rate when immersed in 72 hours, the absorption rates were showed up to 1. 01~1. 24 times by G, 1. 03~1. 58 times by U and 1. 10~5. 91 times by J foaming mortar than cement mortar. It was significantly higher at the early stage of immersed time than cement mortar. 4. At the mixing ratio of 1:1, the lowest air contents were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. Air contents were contented up to 4. 0~17. 2 times by G, 5. 2~23. 2 times by U and 23. 8~74. 5 times by J foaming mortar than cement mortar. 5. At the mixing ratio of 1 : 1, the lowest decreasing rates of strengths were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. Specially, the strengths of 28 days were decreased 0. 4~2. 2% than those of 7 days by foaming mortar, respectively. Also, the correlations between compressive and tensile strength, compressive and ending strength, tensile and bending strength were highly significant as a straight line shaped, respectively. 6. The correlations between absorption rate, air content, compressive strength and bulk density, absorption rate, compressive strength and air content were highly significant, respectively. The multiple regression equations of water-cement ratio, bulk density, absorption ate, air content, compressive strength, tensile strength and bending strength were computed depending on a function of mixing ratio and addition of foaming agent. It was highly significant, respectively. 7. At the mixing ratio of 1 : 1, the highest strengths were showed by cement mortar and foaming mortars, by chemical reagents. But, it gradually was decreased in poorer mixing ratio. The decreasing rates of strengths were in order of H $_2$S0 $_4$, HNO$_3$ and HCI, J,U,G foaming mortar and cement mortar. Specially, at the each mixing ratio, each chemical reagent and 3.0% of foaming agent, J foaming mortar was collapsed obviously. Therefore, for the structures requiring acid resistence, adding of foaming agent should be lower than 3.0%.

  • PDF

Studies on Influence of Water-Proof Agents on the Properties of Mortar (방수제(防水劑)가 모르터의 제성질(諸性質)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kim, Seong Wan;Sung, Chan Yong;Kim, Sun Young
    • Korean Journal of Agricultural Science
    • /
    • v.14 no.2
    • /
    • pp.358-372
    • /
    • 1987
  • This study was performed to obtain data which can be applied to use of water-proof mortars. The data was based on the properties of water-proof mortars depending upon various mixing ratios to compare those of cement mortar. The water-proof agents used were retard and accelerate type which are being used as mortar structures. The water-proof agents, mixing ratios of cement to fine aggregate were 1:1, 1:2, 1:3 and 1:4. The results obtained were summarised as follows; 1. The results of flow test, water-cement ratio was increased with the increasing of mixing ratio. 2. The permeability were increased in poorer mixing ratio and higher water pressure. 3. The bulk density was decreased with the increasing of mixing ratio, and compressive and tensile strength were increased with increasing of the bulk density. 4. At 1:1 mixing ratio, the highest strengths were showed and strengths were decreased with the increasing of mixing ratio. 5. The absorption rates were increased in- poorer mixing ratio 6. The correlation between W/C, permeability, bulk density, compressive strength and absorption rate were highly significant as a straight line, respectively.

  • PDF

Sensitivity of NOx Removal on Recycled TiO2 in Cement Mortar (재생 이산화티탄을 혼입한 모르타르의 NOx 저감률 민감도 분석)

  • Rhee, Inkyu;Kim, Jin-Hee;Kim, Jong-Ho;Roh, Young-Sook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.388-395
    • /
    • 2016
  • This paper explores the photocatalytic sensitivity of cement mortar incorporated with recycled $TiO_2$ from waste water sludge. Basically, $TiO_2$ cluster sank down slowly to the bottom of cement mortar specimen before setting and hardening process. This leads the mismatch of $TiO_2$ concentration on the top and the bottom faces of a specimen. This poorly dispersed $TiO_2$-cement mortar naturally exhibits poor NOx removal efficiency especially on the top of cementitious structure. In architectural engineering application such as building or housing structures, one can simply filp over from the bottom so that more $TiO_2$ concentrated surface can be placed outward into the air. However, in highway pavement case, this could not be applicable due to in-situ installation of concrete pavement. Hence, the dispersion of $TiO_2$ cluster inside the cementitous material is getting important issue onto road construction application. To elaborate this issue, according to our results, silica fume, high-ranged water reducer, viscosity agent, blast furnace slag were not enhanced much of dispersion characteristics of $TiO_2$ cluster. The combination of foaming agent and accelerator of hardening with viscosity agent and small grain size of fine aggregate may help the dispersion of $TiO_2$ inside cementitious materials. Even though the enhanced dispersion were applied to the specimen, NOx removal efficiency doest not change much for the top surface of the specimen. This concurrently affected by the presence of tiny air voids and the dispersion of $TiO_2$ in that these voids could easily adsorbed NOx gas with the aid of large surface area.

Community Structures of Evergreen Broad-leaved Forest of Mt. Yeogwi in Jin-do Island (진도 여귀산 상록활엽수림의 군집구조)

  • Jang, Jeong Jae;Kim, Joon Sun
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.6
    • /
    • pp.410-419
    • /
    • 2005
  • Community structure of evergreen broad-leaved forest of Mt. Yeogwi in Jin-do was investigated to secure sustainable conservation of evergreen broad-leaved forest. Twenty survey plots of $20m{\times}20m$ were established along the elevation from 200 m to 390 m above the sea level in the northwestern slope. The woody species were tallied at each plots. DBH distribution of the major evergreen broad-leaved trees was investigated to find out the spatial distribution. Cluster analysis was applied to a set of vegetation data, that is, importance value to classify the forest community. Species diversity, evenness and species correlation were analysed. Canonical correspondence analysis was also applied to vegetation data and soil environmental data. Cluster analysis showed that the forests of Mt. Yeogwi were classified into 2 community groups, such as Camellia japonica community group and Quercus acuta community group. C japonica community group was subdivided into C japonica- evergreen broad-leaved trees community, C. japonica-Neolitsea sericea community, and C. japonica-deciduous broad-leaved trees community. Q. acuta community group was subdivided into Q. acuta-C. japonica community, and Q. acuta community. C. japonica, Q. acuta, N. sericea, Machilus thunbergii and Illicium religiosum were dominant evergreen broad-leaved tree species, while Styrax japonica, Lindera erythrocarpa, Cornus kousa, Prunus sargentii, Albizzia julibrisin and Quercus acutissima were major deciduous tree species. Species diversity was greater in Q. acuta community group (0.8231 for Q. acuta-C. japonica community, and 0.8135 for Q. acuta community) than in C. japonica community group (0.7674 for C. japonica-evergreen broad-leaved trees community, 0.6164 for C. japonica-N. sericea community, and 0.7931 for C. japonica-deciduous broad-leaved trees community). DBH 2 cm~10 cm of major evergreen broad-leaved trees occupied 80% of all. C. japonica of less than DBH 5 cm tended to aggregate but distribute randomly or regularly with increasing DBH. Q. acuta distributed more aggregately than C. japonica and Machilus thunbergii for more than 15 cm of DBH. C. japonica correlated negatively with Q. acuta, I. religiosum and C. kousa, but positively with N. sericea. with significance at 1% level. Q. acuta correlated negatively with C. japonica, N. sericea and M. thunbergii but positively with l. religiosum. There were also negative correlation between N. sericea and C. kousa. CCA showed that forest communities were correlated with soil variables such as CEC, soil organic matter and soil pH. With increased soil organic matter and CEC, and decreased soil pH, C. japonica was dominant and forest community and Q. acuta and N. sericea tended to develop in the evergreen broad-leaved forest.

Study of HubWA Protein Folding Reaction by Measuring the Stability of Folding Intermediate (중간단계의 구조적 안정성을 통한 HubWA 단백질의 접힘(folding) 반응 탐색)

  • Soon-Ho Park
    • Journal of the Korean Chemical Society
    • /
    • v.67 no.2
    • /
    • pp.81-88
    • /
    • 2023
  • The contribution of hydrophobic residues to the protein folding reaction was studied by using HubWA variant proteins with I and L to V mutation. Folding kinetics of all V variant proteins was observed to be satisfied by a three-state on-pathway mechanism, U ⇌ I ⇌ N, where U, I, and N represent unfolded, intermediate, and native state, respectively. Three-state folding reaction was quantitatively analyzed and the free energy of folding of each elementary reactions and overall folding reaction, ΔGoUI, ΔGoIN, and ΔGoUN, were obtained. From the ratio of free energy difference between the variant protein and HubWA, ΔΔGoUI/ΔΔGoUN (ΔΔGoUI = ΔGoUI (variant protein) - ΔGoUI (HubWA) and ΔΔGoUN = ΔGoUN (variant protein) - ΔGoUN(HubWA)), the contribution of hydrophobic residues to HubWA folding was analyzed. The residues which are located in the hydrophobic core between α-helix and β-sheet, I3, I13, L15, I30, L43, I61 and L67, showed ΔΔGoUI/ΔΔGoUN value of ~0.5 when each of these residues was mutated to V, indicating that these residues form relatively solid hydrophobic core in the intermediate state. Residues located at the end of secondary structures and loop, I23, L69 and I36 showed ΔΔGoUI/ΔΔGoUN value below 0.4 when each of these residues was mutated to V, indicating that the region containing these residues are loosely formed in the intermediate state. V17A, L50V and L56V showed fairly high ΔΔGoUI/ΔΔGoUN value of ~0.8. Since L50 and L56 are located in the region containing long loop (residue 46 to 62), it is suggested that the high ΔΔGoUI/ΔΔGoUN value of these residues prevents the formation of aggregate at the early stage of folding reaction.