• Title/Summary/Keyword: age of air

Search Result 756, Processing Time 0.039 seconds

Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space (바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향)

  • 정광섭;한화택;홍승재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

Study on Improvement of Air Quality through Analysis of Ventilation Efficiency in Complex Enclosures of a Ship (선박 복합 밀폐공간 내 환기효율 분석을 통한 공기환경 개선에 관한 연구)

  • Jeong, Jae-Hoon;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.440-447
    • /
    • 2015
  • In the shipbuilding process, the confined work spaces of the ship are formed continuously; the ventilation method can therefore be limited to dilution ventilation due to the complex structure and limited opening of the confined space. Also, it is difficult to evaluate air-quality using measurement and an adequate ventilation method. CFD simulation methods are typically used in analyzing ventilation efficiency in these cases. In this study, a method is suggested to analyze the air quality of the complex enclosures in shipbuilding using CFD. Especially, among the conventional indices, the ventilation efficiency scales or indices, the supply air contribution (SVE4), and the age of the air (SVE3) (fit for the confined and complex enclosure) were applied.

Measurements of Ventilation Effectiveness in an Underfloor Air-Conditioned Space Using a Tracer Gas Technique

  • Han, Hwa-Taik;Seo, S.Y.;Kim, M.H.;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.91-100
    • /
    • 1999
  • This paper investigates ventilation characteristics of an environmental chamber simulating an under-floor air conditioning system for isothermal and cooling supply air conditions. The tracer gas sulfur-hexafluoride (SF$F_6$) was injected into a supply duct using step-up and step-down methods. Local mean and room mean ages were calculated from the concentrations measured at internal points and at the exhaust duct. The air change efficiency of the chamber has been found to be greater in cooling conditions than in isothermal conditions. Also the room air change efficiency is not significantly affected but slightly improved by the presence of a supply diffuser.

  • PDF

Analysis of the influence of panel characteristics on odor measurement based on the air dilution olfactory method in Korea

  • Kim, Sun-Tae;Lee, Seokjun;Yim, Bongbeen
    • Environmental Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.91-98
    • /
    • 2019
  • This study was to objectify differences in the results of odor testing according to the characteristics of panel members that participate in air dilution olfactory method (ADOM) testing. When differences in the results of olfactory testing were reviewed in relation to characteristics of the panelists, the result of entire panels for the site boundary Proficiency Testing Materials (PTMs) showed no difference according to panelist sex, age, smoking status, and past participation in ADOM tests. As for the outlet PTMs, distinct differences appeared in relation to the smoking status and age of panelists. The frequency distribution for all the panelists (Dev($D/T_{total}$)) showed a form similar to a normal distribution, so it is thought to be more appropriate for the review of effect of panelist characteristics on the result of air dilution olfactory tests. In addition, the ADOM testing method implemented as the standard method for odor compounds in Korea (Dev($D/T_3$)) will have to be implemented along with a concurrent assessment, for the purpose of identifying the effect of panelist characteristics on administrative dispositions against malodors.

Study on the Development of the Mobile Pig Nursery for Early Weaned Piglet (조기이유 자돈 사육을 위한 이동식 자돈사 개발에 관한 연구)

  • 유용희;이덕수;정일병;이진우;전병수;한정대
    • Journal of Animal Environmental Science
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • The objective of this study was conducted to develope a mobile pig nursery(MPN) for segregation of early weaned piglet. The units of MPN was consisted of 4 rectangle-type pens, 1 workroom, 2 doors, 3 windows, 1 air-inlet, 1 exhaust fan, and 1 cooling and heating system. Total of 40 piglet were weaned at 7 days of age. The period of the feeding test was 63 days. The results obtained are as follows: 1. The insulation thickness was 70, 70 and 50 mm of roof, floor and wall, respectively. R-value was 15.32 and 10.32 of roof and wall, respectively. 2. Exhaust fan( 30.48) was installed near back door 40cm from the bottom. When exhaust fan speeds were 15, 20, 30 and 35%, Air ventilation was required 9.75, 7.07, 1.72, 1.45 minutes of respectively. 3. Average temperature in the MPN was able to maintain 27∼28$^{\circ}C$ from 7∼28 days of age, 24∼25$^{\circ}C$ from 35∼56 days of age and 20∼21.5$^{\circ}C$ from 56∼70 days of age. 4. Average daily gain, feed intake and feed conversion were 420.6g, 761.5g, 1.81 respectively.

A Comparison Study on Isoprene Emission Rates from White Oak (갈참나무로부터 발생되는 이소프렌의 배출속도 비교 연구)

  • Son, Youn-Suk;Kim, Jo-Chun;Kim, Ki-Joon;Lim, Yong-Jae;SunWoo, Young;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.791-798
    • /
    • 2006
  • In order to investigate the NVOC (Natural Volatile Organic Compound) emissions from White Oak, the emission rates of isoprene were measured according to season, weather conditions, and the age of the tree. The analysis of seasonal emission rates showed that the emission rates were the highest during summer followed by spring and fall. The emission rates during summer were found to be nearly 8 times greater than those during fall. In addition, it was observed that the emission rates of isoprene depends on PAR and temperature. Moreover, the effect of age on the emission rates was studied, and the White Oak in the age range of $21{\sim}30$ had higher emission rates than that in the range of $41{\sim}50$. Accordingly, the current result indicates that the isoprene emissions are affected by both meteorological parameter and the age of a tree.

Prediction of Air Exchange Performance of an Air Purifier by Installation Location using Artificial Neural Network (인공신경망 기반 공기정화기 설치위치에 따른 공기교환성능 예측)

  • Kim, Na Kyong;Kang, Dong Hee;Kang, Hyun Wook
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.2
    • /
    • pp.21-27
    • /
    • 2022
  • Air purifiers can be placed where the air cleaning is required, making it easy to manage indoor air quality. The position of the air purifier affects the indoor airflow pattern, resulting in different air cleaning efficiency. Many efforts and strategies have been examined through numerical simulations and experiments to find the proper location of the air purifier, but problems still remain due to the various geometrical indoor spaces and arrangements. Herein, we develop an artificial intelligence model to predict the performance of an air purifier depending on the installation location. To obtain the training data, numerical simulations were performed on the different locations of the air purifiers and airflow patterns. The trained artificial intelligence model predicted the air exchange performance depending on the installation location of the air purifier with a prediction accuracy of 92%.

The Effects of Cervical Traction on the Pain, Range of Motion and the Quality of Sleep of the Older Women with Tension Headache (목뼈 견인치료가 긴장성 두통을 가진 노인 여성의 통증, 관절가동범위 및 수면의 질에 미치는 영향)

  • Kim, Youngjung;Yoo, Byungkook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.1
    • /
    • pp.51-62
    • /
    • 2014
  • Purpose : The purpose of this work was to ascertain the effects of cervical traction on the pain, the range of motion and the quality of sleep of the older women with the tension headache. Method : 25 subjects between ages 66 and 82 who agreed on this experiment and diagnosed with tension headache participated in this study. All subjects were treated with air-pressure cervical traction while 20 minutes a day, 3 times per week, for 4 weeks. The effects of air-pressure cervical traction were evaluated by PSQI(Pittsburgh sleep quality index), a pain last a day, VAS, and four ROMs. In order to investigate the effect of age on the treatment, subjects were divided into two groups, of less and of over than age 75. The measured data were analyzed by using one-way repeated ANOVA and two-way repeated ANOVA. Result : 1) The group of less than age 75 showed the significant improvements in all measurement variables, PSQI, a pain last a day, VAS and four ROMs. 2) The group of over than age 75 showed the significant improvements in all measurement variables excluding the flexion ROM of cervical. 3) No significant differences between two groups were showed in all measurement variables, but the interaction effect between group and period was significant in only VAS. Conclusion : From the results of this study, a cervical traction intervention using an air-pressure cervical traction proved to be effective on the reduction of tension headache and the improvement of the quality of sleep.

Development of Straightforward Method of Estimating LMA and LMR using Computational Fluid Dynamics Technology (전산유체역학 기법을 이용한 공기연령 산정 방법의 개발)

  • Park, Se-Jun;Lee, In-Bok;Hong, Se-Woon;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Yun, Nam-Gyu;Kim, Hyung-Gewon;Kwon, Sun-Hong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.135-144
    • /
    • 2013
  • Ventilation efficiency has an important role in agricultural facilities such as greenhouse and livestock house to keep internally optimum environmental condition. Age-of-air concept allows to assess the ventilation efficiency of an agricultural facility according to estimating the ability of fresh air supply and contaminants emission using LMA and LMR. Most of these methods use a tracer gas method which has some limitations in experiment like dealing unstable and invisible gas. Therefore, the aim of this study was to develop a straightforward method to calculate age-of-air values with CFD simulation which has the advantage of saving computational time and resources and these method can solve the limitations in experiment using tracer gas method. The main idea of LMA computation is to solve the passive scalar transport equation with the assumption that the production of the time scalar throughout the room is uniform. In case of LMR calculation, the transport of the time scalar was reversed compulsively using UDF. The methodology to validate the results of this study was established by comparing with preceding research that had performed a computing LMA and LMR value by laboratory experiments and CFD simulations using tracer gas. As a result, the error was presented similarly level of results of preceding research. Some big errors could be caused by stagnated area and incongruity turbulence model. while the computational time was reduced to almost one fourth of that by preceding research.