• Title/Summary/Keyword: age difference

Search Result 7,792, Processing Time 0.04 seconds

The Spectrum of CT Findings of COVID-19 Pneumonia: Acute Alveolar Insult and Organizing Pneumonia as Different Phases of Lung Injury and Repair (COVID-19 폐렴의 다양한 CT 영상 소견: 급성 폐포 손상과 기질화 폐렴)

  • Yun Su Kim;Ung Rae Kang;Young Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.359-370
    • /
    • 2021
  • Purpose To analyze the findings and serial changes in chest CT lesions in 123 symptomatic patients with coronavirus disease 2019 (COVID-19). Materials and Methods From February 19 to April 7, 2020, a total of 123 confirmed COVID-19 patients (male, 44; female, 79; mean age, 59.2 ± 18.6) were enrolled in this retrospective study. A total of 234 CT scans were reviewed for the following patterns: acute alveolar insult (AAI) patterns: ground-glass opacity (GGO), crazy-paving appearance, mixed pattern, and consolidation; organizing pneumonia (OP) patterns: perilobular patterns, band opacity, curvilinear opacity, reversed halo opacity, and small nodular consolidation; resolving patterns: pure GGO, remnant curvilinear, small nodular consolidation, and serial changes of lung abnormalities. We compared the proportions of AAI pattern, OP pattern, or resolving pattern with time progression and analyzed the association between the patterns and disease severity using Pearson chi-square and Fisher's exact test. Results Predominant CT patterns were AAI pattern (87%) in the early hospital period group (0-10 days, after the onset of symptoms), OP pattern (45.7%) in the later hospital period group (after 10 days), and resolving pattern in discharge and follow-up group (47.2% and 84.8%, respectively). The difference in the proportions of predominant CT patterns with time progression was statistically significant (p < 0.001, Pearson's chi-square test). No statistically significant association was observed between the patterns and disease severity (p = 0.055, Fisher's exact test). No fibrous changes in the lesions were observed on follow-up CT scans. Conclusion The serial CT scans of COVID-19 patients showed the spectrum of COVID pneumonia CT manifestations as different phases of lung injury and repair.

Risk Factors for Binge-eating and Food Addiction : Analysis with Propensity-Score Matching and Logistic Regression (폭식행동 및 음식중독의 위험요인 분석: 성향점수매칭과 로지스틱 회귀모델을 이용한 분석)

  • Jake Jeong;Whanhee Lee;Jung In Choi;Young Hye Cho;Kwangyeol Baek
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.4
    • /
    • pp.685-698
    • /
    • 2023
  • This study aimed to identify binge-eating behavior and food addiction in Korean population and to determine their associations with obesity, eating behaviors, mental health and cognitive characteristics. We collected clinical questionnaire scores related to eating problems (e.g. binge eating, food addiction, food cravings), mental health (e.g. depression), and cognitive functions (e.g. impulsivity, emotion regulation) in 257 Korean adults in the normal and the obese weight ranges. Binge-eating and food addiction were most frequent in obese women (binge-eating: 46.6%, food addiction: 29.3%) when we divided the participants into 4 groups depending on gender and obesity status. The independence test using the data with propensity score matching confirmed that binge-eating and food addiction were more prevalent in obese individuals. Finally, we constructed the logistic regression models using forward selection method to evaluate the influence of various clinical questionnaire scores on binge-eating and food addiction respectively. Binge-eating was significantly associated with the clinical scales of eating disorders, food craving, state anxiety, and emotion regulation (cognitive reappraisal) as well as food addiction. Food addiction demonstrated the significant effect of food craving, binge-eating, the interaction of obesity and age, and years of education. In conclusion, we found that binge-eating and food addiction are much more frequent in females and obese individuals. Both binge-eating and food addiction commonly involved eating problems (e.g. food craving), but there was difference in mental health and cognitive risk factors. Therefore, it is required to distinguish food addiction from binge-eating and investigate intrinsic and environmental risk factors for each pathology.

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Overview of Utilization of Four-wheel Tractor in Korea(I) -Ownership and Annual Use by Different Farm Groups- (농용(農用)트랙터 이용(利用)에 관(關)한 조사연구(調査硏究)(I) -경영형태별(經營形態別) 농작업이용실태분석(農作業利用實態分析)-)

  • Park, Ho Seok;Kim, Kyong Su;Lee, Yong Kook;Han, Sung Kum
    • Journal of Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.20-32
    • /
    • 1982
  • This survey was conducted to investigate the present status of farm tractor utilization for obtaining a basic reference to the establishment of the government's agricultural mechanization strategies. Thirty two counties from the eight provinces except Jeju were covered in this study. From these selected areas, 433 sample farms having farm tractor were taken to obtain the general informations by the enquete, and 93 sample farms among them to investigate the status of daily tractor use in the year of 1980. The analyzed results are summarized as follows: 1. Farm tractors owned by the rice-oriented farms holds 71.5 percent of the total number of tractors the livestock-oriented farms 17.0 percent, and the orchard-oriented farms 7.0 percent. Among the farm tractors 64.3 percent was a large size (46ps) and 35.7 percent a small size(19~23ps). 2. Most of the tractors surveyed were equipped with the essential attachments such as plow and rotavator. About 18 percent of the tractor owners had no trailer, which seemed too high considering the large percentage of tractor use for transportation. The availability of other attachments was very low except a grader on the rice-oriented farms and a hay harvester and a front loader on the livestock-oriented farms. 3. The average size of farm was 3.9 hectare for the rice-oriented farms, 13.9 hectare for the livestock-oriented farms and 7.4 hectare for the orchard-oriented farms. It was obious that the average farm size of was too small compared to the theoretical machine capacity of the tractors. 4. About 70 percent of the tractor operators were in the age of twenties and thirties. About 90 percent of them had an educational level of middle school graduate or above even though their technical level was very low. 5. Any particular problem in tractor use was not found in this survey. From the farmer's preference for purchasing a new tractor, however, it is estimated the demand on a 20-30ps tractor will be more increased. 6. The average annual use of tractor was of about 100 days or 400 hours. It appeared that the rice-oriented farms used most with 412.4 hours per year, and followed by the livestock-oriented farms with 403.6 hours, the orchard oriented farms with 377.7 hours. 7. Among the total hours of tractor use, 47.3 percent was for transportation, and 41.6 percent was for plowing and rotary tillage. The largest portion of the annual tractor use was taken by transportation on the livestock-oriented farms, by land preperation on the rice-oriented farms, and by loading and chemical spraying on the orchard-oriented farms. 8. The hours of tractor use had a peak in May. The hours of use for own farm was remarkably different among the different farm oriented, but there was no considerable difference between the too different sizes of tractor. 9. The hours of tractor use decreased as the age of the operator or the educational level increased. The reason might be that the operators who had a high educational level or were older had a tendency of disliking custom works. 10. The average custom use of tractor was 171.3 hours per year, and the ratio of custom work was 63.7 percent on the rice-oriented farms, 31.7 percent on the livestock-oriented farms and 22.4 percent on the orchard-oriented farms. Among the custom works, the most popular one was the grader leveling. 11. The charge on custom work was about 40,000 Won per hectare for plowing and rotary tillage, and it was the most expensive in the southeastern region, and next followed by the southwestern region. 12. The average plowing capacity of the small tractor was 7.8 hours per hectare in the paddy field, and that of the large tractors was 4.3 hours per hectare. The average rotary-tilling capacities of the small and the large tractors were 6.5 and 4.3 hours per hectare, in the paddy field respectively.

  • PDF

The Location of Medical Facilities and Its Inhabitants' Efficient Utilization in Kwangju City (광주시(光州市) 의료시설(醫療施設)의 입지(立地)와 주민(住民)의 효율적(效率的) 이용(利用))

  • Jeon, Kyung-Sook
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.2
    • /
    • pp.163-193
    • /
    • 1997
  • Medical services are a fundamental and essential service in all urban areas. The location and accessibility of medical service facilities and institutions are critical to the diagnosis, control and prevention of illness and disease. The purpose of this paper is to present the results of a study on the location of medical facilities in Kwangju and the utilization of these facilities by the inhabitants. The following information is a summary of the findings: (1) Korea, like many countries, is now witnessing an increase in the age of its population as a result of higher living standards and better medical services. Korea is also experiencing a rapid increase in health care costs. To ensure easy access to medical consultation, diagnosis and treatment by individuals, the hierarchical efficient location of medical facilities, low medical costs, equalized medical services, preventive medical care is important. (2) In Korea, the quality of medical services has improved significantly as evident by the increased number of medical facilities and medical personnel. However, there is still a need for not only quantitative improvements but also for a more equitable distribution of and location of medical services. (3) There are 503 medical facilities in Kwangju each with a need to service 2,556 people. This is below the national average of 1,498 inhabitants per facility. The higher locational quotient and satisfactory population per medical facility showed at the civic center. On the other hand, problem regions such as the traditional residential area in Buk-Gu, Moo-deung mountain area and the outer areas of west Kwangju still maintain rural characteristics. (4) In the study area there are 86 general medicine clinics which provide basic medical services. i. e. one clinic per every 14,949 residents. As a basic service, its higher locational quotient showed in the residential area. The lower population concentration per clinic was found in the civic center and in the former town center, Songjeong-dong. In recently build residential areas and in the civic center, the lack of general medicine clinics is not a serious medical services issue because of the surplus of medical specialists in Korea. People are inclined to seek a consultation with a specialist in specific fields rather than consult a general practitioner. As a result of this phenomenon, there are 81 internal medicine facilities. Of these, 32.1% provide services to people who are not referred by a primary care physician but who self-diagnose then choose a medical facility specializing in what they believe to be their health problem. Areas in the city, called dongs, without any internal facilities make up 50% of the total 101 dongs. (5) There are 78 surgical facilities within the area, and there is little difference at the locational appearance from internal medicine facilities. There are also 71 pediatric health clinics for people under 15 years of age in this area, represents one clinic per 5,063 people. On the quantitative aspect, this is a positive situation. Accessibility is the most important facility choice factor, so it should be evenly located in proportion to demander distribution. However, 61% of 102 dongs have no pediatric clinics because of the uneven location. (6) There are 43 obstetrical and gynecological clinics in Kwangju, and the number of residents being served per clinic is 15,063. These services need to be given regularly so it should increase the numbers. There are 37 ENT clinics in the study area with the lower concentration in Dong-gu (32.4%) making no locational differences by dong. There are 23 dermatology clinics with the largest concentration in Dong-Gu. There are 17 ophthalmic clinics concentrated in the residential area because of the primary function of this type of specialization. (7) The use of general medicine clinics, internal medicine clinics, pediatric clinics, ENT clinics by the inhabitants indicate a trend toward primary or routine medical services. Obstetrics and gynecology clinics are used on a regular basis. In choosing a general medicine clinic, internal medicine clinic, pediatric clinic, and a ENT clinic, accessibility is the key factor while choice of a general hospital, surgery clinic, or an obstetrics and gynecology clinic, thes faith and trust in the medical practitioner is the priority consideration. (8) I considered the efficient use of medical facilities in the aspect of locational and management and suggest the following: First, primary care facilities should be evenly distributed in every area. In Kwangju, the number of medical facilities is the lowest among the six largest cities in Korea. Moreover, they are concentrated in Dong-gu and in newly developed areas. The desired number of medical facilities should be within 30 minutes of each person's home. For regional development there is a need to develop a plan to balance, for example, taxes and funds supporting personnel, equipment and facilities. Secondly, medical services should be co-ordinated to ensure consistent, appropriate, quality services. Primary medical facilities should take charge of out-patient activities, and every effort should be made to standardize and equalize equipment and facility resources and to ensure ongoing development and training in the primary services field. A few specialty medical facilities and general hospitals should establish a priority service for incurable and terminally ill patients. (9) The management scheme for the inhabitants' efficient use of medical service is as follows: The first task is to efficiently manage medical facilities and related services. Higher quality of medical services can be accomplished within the rapidly changing medical environment. A network of social, administrative and medical organizations within an area should be established to promote information gathering and sharing strategies to better assist the community. Statistics and trends on the rate or occurrence of diseases, births, deaths, medical and environment conditions of the poor or estranged people should be maintained and monitored. The second task is to increase resources in the area of disease prevention and health promotion. Currently the focus is on the treatment and care of individuals with illness or disease. A strong emphasis should also be placed on promoting prevention of illness and injury within the community through not only public health offices but also via medical service facilities. Home medical care should be established and medical testing centers should be located as an ordinary service level. Also, reduced medical costs for the physically handicapped, cardiac patients, and mentally ill or handicapped patients should be considered.

  • PDF

Clinical Aspects of Bacteremia in Medical and Surgical Intensive Care Units (내과 및 외과계 중환자실 환자 균혈증의 임상적 고찰)

  • Kim, Eun-Ok;Lim, Chae-Man;Lee, Jae-Kyoon;Mung, Sung-Jae;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Hwan;Choi, Jong-Moo;Pai, Chik-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.535-547
    • /
    • 1995
  • Background: Intensive care units(ICUs) probably represent the single largest identifiable source of infection within the hospital. Although there are several studies on ICU infections in respect to their bacteriology or mortality rate for individual types of ICU, few studies have compared ICU infections between different types of ICU. The aim of this study was to identify clinical differences in bacteremia between medical ICU(MICU) and surgical ICU(SICU) patients. Methods: 256 patients with bacteremia were retrospectively evaluated. Medical records were reviewed to obtain the clinical and bacteriologic informations. Results: 1) The mean age of the patients with bacteremia of MICU($58.6{\pm}17.2\;yr$) was greater than that of all MICU patients($54.3{\pm}17.1\;yr$)(p<0.01), but there was no significant difference in SICU patients(patients with bacteremia of SICU: $56.3{\pm}18.6\;yr$, all SICU patients: $62.0{\pm}16.8$)(p>0.05). ICU stay was longer(MICU patients: $23.4{\pm}40.8$ day, SICU patients: $30.3{\pm}26.8$ day) than the mean stay of all patients($6.8{\pm}15.5$ day)(p<0.05, respectively). Bacteremia of both ICU patients developed past the average day of ICU stay(all MICU patients: 7.9 day, all SICU patients: 6.0 day, MICU bacteremia: 19th day, SICU bacteremia: 17th day of ICU stay)(p<0.05, respectively). 2) There were no significant differences in mean age, sex, and length of stay of both ICU patients with bacteremia. 3) Use of antibiotics or steroid, use of percutaneous devices and invasive procedures before development of bacteremia were more frequent in SICU patients than in MICU patients(prior antibiotics use: MICU 45%, SICU 63%, p<0.05; steroid use: MICU 14%, SICU 36%, p<0.01; use of percutaneous devices: MICU 19%, SICU 39%, p<0.01; invasive procedures: MICU 19%, SICU 61 %, p<0.01). 4) The prevalence of community acquired infections was significantly higher in MICU patients than in SICU patients(MICU 42%, SICU 9%)(p<0.01), whereas SICU patients showed higher prevalence of ICU-acquired infection than MICU patients(MICU 48%, SICU 78%)(p<0.01). 5) There were no differences in causative organisms, primary sites of infection and time interval to bacteremia between both ICUs. 6) There were no significant differences in outcome according to pathogenic organisms or primary sites of infection. 7) The mortality rate was higher in patients with bacteremia than without bacteremia(MICU mortality rate: patients with bacteremia 72.5%, patients without bacteremia 36.0%, p<0.01; SICU mortality rate: patients with bacteremia 40.3%, patients without bacteremia 8.5%, p<0.05), and the mortality rate of MICU bacteremia was significantly higher compared with that of SICU bacteremia(MICU 72.5%, SICU 40.3%)(p<0.01). Conclusion: ICU patients with bacteremia stayed longer before the development of bacteremia, and showed higher mortality than the overall ICU population. The incidence of bacteremia was higher in MICU patients than SICU patients. MICU patients with bacteremia showed higher prevalence of liver diseases and acute respiratory failure, community-acquired bacteremia and greater mortality rate than SICU patients with bacteremia. SICU patients with bacteremia, on the other hand, showed higher prevalence of trauma, prior use of immunosuppressive agents, invasive procedures, and ICU-acquired bacteremia, and lower mortality rate than MICU patients with bacteremia.

  • PDF

The Clinical Characteristics of Lung Cancer in Patients with Idiopathic Pulmonary Fibrosis (특발성 폐섬유화증에 동반된 폐암 환자의 임상적 특정)

  • Park, Joo-Hun;Lee, Jin-Seong;Song, Koun-Sik;Shim, Tae-Sun;Lim, Chae-Man;Koh, Youn-Suck;Lee, Sang-Do;Kim, Woo-Sung;Kim, Won-Dong;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.674-684
    • /
    • 1999
  • Background : It has been generally known that the incidence of lung cancer is higher in the patients with idopathic pumonary fibrosis (IPF) than those in general population. The reported incidence was variable from 4.8 to 43.2%. There were controversies on the most frequent cell type (squamous cell carcinoma vs. adenocarcinoma) and no study was done about the real concordance of cancer and the fibrotic lesion. And the pulmonary fibrosis may influence not only the development of cancer but also the treatment and prognosis of the cancer, but there was no report on that point. Method : Total 63 patients ($66.8{\pm}7.8$ year, M : F=61 : 2) were diagnosed as IPF combined with lung cancer (IFF-CA) at Asan Medical Center. A retrospective analysis was done about the risk factors of the lung cancer, pulmonary function test, the site of cancer(especially the relationship of the cancer with the fibrotic lesion), the histologic types, and the stage of cancer. The histologic types were compared with those of 2,660 patients with lung cancer who were diagnosed at the same institute for the same period. The effect of IPF on the treatment of the cancer was evaluated with the survival time after the detection of lung cancer. Results : The lung cancer was found in 63(22.9%) out of 281 patients with IPF. But in most of them(45 patients), lung cancer was detected at the same time with IPF and only in 18 patients, the cancer was diagnosed during the follow-up($25.2{\pm}17.7$ months) of IPF. So in our study, 6.7% of patients with IPF developed lung cancer during the course of the disease. The age ($66.8{\pm}7.84$ vs. $63.4{\pm}11.1$ years), percentage of smoker (88.9 vs. 67.2%), and the male gender (96.8 vs. 67.6%) were significantly higher in IPF-CA compared with lone IPF (p<0.05). The odds ratio of smoking was 4.7 compared with non smoking IPF controls. The lung cancer was located more frequently in the upper lobe and 55.5% was in the periphery of lung. The cancer was developed in the fibrotic lesion in 23 patients (35.9%), and in the majority of the patients, the cancer was separated from the fibrosis. The cell type of the lung cancer in IPF-CA was squamous cell carcinoma 34.9%, adenocarcinoma 30.2%, small cell carcinoma 19.0%, large cell undifferenciated carcinoma 6.3%, and others 9.5%. No significant difference in the distribution of histologic type of the lung cancer was found between IPF-CA and lone lung cancer. There was no significant difference in demographic features, cell types, location and the stage of the cancer between the group with concurrent IPF-CA and the group with cancer diagnosed during the follow up of IPF. There was a tendency (but statistically not significant : p=0.081) of higher incidence of adenocarcinoma among the cancers developed in the fibrotic area(43.5%) (F-CA) than in the cancers in non-fibrotic area (22.5%) (NF-CA). The prognosis of the patients with F-CA was poor (median survival : 4 months) compared with the patients with NF-CA (7 months, p=0.013), partly because the prevalence of severe IPF (the extent of fibrosis in HRCT 50%) was higher in F-CA group. Conclusion : These data suggest that the lung cancer in the patients with IPF has similar features to the ordinary lung cancer.

  • PDF

Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength (경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교)

  • Park, Choon-Keun;Hwang, Jang-Hoe;Ji, Chul;Lee, Jae Un;Sung, Jae Hoon;Choi, Seung-Jin;Lee, Sang-Won;Seybold, Eric;Park, Sung-Chan;Cho, Kyung-Suok;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1210-1219
    • /
    • 2001
  • Introduction : The purpose of this study was to analyze the safety, pullout strength and radiographic characteristics of unicortical and bicortical screws of cervical facet within cadaveric specimens and evaluate the influence of level of training on the positioning of these screws. Methods : Twenty-one cadavers, mean 78.9 years of age, underwent bilateral placement of 3.5mm AO lateral mass screw from C3-C6(n=168) using a slight variation of the Magerl technique. Intraoperative imaging was not used. The right side(unicortical) utilized only 14mm screws(effective length of 11mm) while on the left side to determine the length of the screw after the ventral cortex had been drilled. Three spine surgeons(attending, fellow, chief resident) with varying levels of spine training performed the procedure on seven cadavers each. All spines were harvested and lateral radiographs were taken. Individual cervical vertebrae were carefully dissected and then axial radiographs were taken. The screws were evaluated clinically and radiographically for their safety. Screws were graded clinically for their safety with respect to the spinal cord, facet joint, nerve root and vertebral artery. The grades consisted of the following categories : "satisfactory", "at risk" and "direct injury". Each screw was also graded according to its zone placement. Screw position was quantified by measuring a sagittal angle from the lateral radiograph and an axial angle from the axial radiograph. Pull-out force was determined for all screws using a material testing machine. Results : Dissection revealed that fifteen screws on the left side actually had only unicortical and not bicortical purchase as intended. The majority of screws(92.8%) were satisfactory in terms of safety. There were no injuries to the spinal cord. On the right side(unicortical), 98.9% of the screws were "satisfactory" and on the left side(bicortical) 68.1% were "satisfactory". There was a 5.8% incidence of direct arterial injury and a 17.4% incidence of direct nerve root injury with the bicortical screws. There were no "direct injuries" with the unicortical screws for the nerve root or vertebral artery. The unicortical screws had a 21.4% incidence of direct injury of the facet joint, while the bicortical screws had a 21.7% incidence. The majority of "direct injury" of bicortical screws were placed by the surgeon with the least experience. The performance of the resident surgeon was significantly different from the attending or fellow(p<0.05) in terms of safety of the nerve root and vertebral artery. The attending's performance was significantly better than the resident or fellow(p<0.05) in terms of safety of the facet joint. There was no relationship between the safety of a screw and its zone placement. The axial deviation angle measured $23.5{\pm}6.6$ degrees and $19.8{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The resident surgeon had a significantly lower angle than the attending or fellow(p<0.05). The sagittal angle measured $66.3{\pm}7.0$ degrees and $62.3{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The attending had a significantly lower sagittal angle than the fellow or resident(p<0.05). Thirty-three screws that entered the facet joint were tested for pull-out strength but excluded from the data because they were not lateral mass screws per-se and had deviated substantially from the intended final trajectory. The mean pull-out force for all screws was $542.9{\pm}296.6N$. There was no statistically significant difference between the pull-out force for unicortical($519.9{\pm}286.9N$) and bicortical($565.2{\pm}306N$) screws. There was no significant difference in pull-out strengths with respect to zone placement. Conclusion : It is our belief that the risk associated with bicortical purchase mandates formal spine training if it is to be done safely and accurately. Unicortical screws are safer regardless of level of training. It is apparent that 14mm lateral mass screws placed in a supero-lateral trajectory in the adult cervical spine provide an equivalent strength with a much lower risk of injury than the longer bicortical screws placed in a similar orientation.

  • PDF

Mitral Valvuloplasty using New Mitral Strip (Mitracon^{(R)}$) (새로운 Strip (Mitracon^{(R)}$)을 이용한 승모판막 성형술)

  • Kang, Seong-Sik;Kim, Sang-Pil;Song, Meong-Gum
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.320-328
    • /
    • 2008
  • Background: Numerous surgical devices for mitral repair have been used in the past with good results. In this study we describe a simple annuloplasty technique with using a new device ($Mitracon^{(R)}$). The aim of this study was to assess its efficacy and surgical results with using $Mitracon^{(R)}$. Material and Method: From May 2003 to October 2005, 46 patients (21 women and 25 men (mean age of $51.4{\pm}17.8$ years) with mitral regurgitation from various causes were treated with either the $Mitracon^{(R)}$ (the $Mitracon^{(R)}$ group) or the Capentier Edward rigid ring (the CE group). The median follow-up duration was 18.9 months. Result: The mean grade of mitral regurgitation before and immediately after surgery in the $Mitracon^{(R)}$ group and the CE group decreased from $3.2{\pm}0.8$ to $0.6{\pm}0.7$ and $3.4{\pm}0.7$ to $0.3{\pm}0.5$, respectively. There were no significant changes in the ejection fraction either between the two groups or before and immediately after surgery. No deaths were seen in either group. Early postoperative echocardiography of all 46 patients showed only trivial mitral regurgitation or none at all. Echocardiography at a median of 18.9 months also showed no progression in mitral regurgitation. The mean grade of mitral regurgitation in the $Mitracon^{(R)}$ group at this time point decreased from $3.2{\pm}0.8$ to $0.8{\pm}0.7$ (p<0.05). The CE group also showed a similar degree of decrease from $3.4{\pm}0.7$ to $0.3{\pm}0.6$ (p<0.05). The mitral valve area in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.3{\pm}0.9cm^2$. The mitral valve area in the CE group was $2.7{\pm}0.6cm^2$. The mean mitral pressure gradient in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.1{\pm}1.3$ mmHg. The mean pressure gradient in the CE group was $4.5{\pm}2.1$ mmHg, although any statistical significant difference for this between the groups was not reached. Conclusion: The present study showed the described technique to be safe and effective in the intermediate term. Because long term results are unavailable, a more extensive prospective randomized multicenter trial may be warranted to determine whether this procedure should be generally applied for repair of mitral valve disease.