• 제목/요약/키워드: aerosol detection

검색결과 69건 처리시간 0.029초

패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가 (Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

The Detection of Yellow Sand with Satellite Infrared bands

  • Ha, Jong-Sung;Kim, Jae-Hwan;Lee, Hyun-Jin
    • 대한원격탐사학회지
    • /
    • 제22권5호
    • /
    • pp.403-406
    • /
    • 2006
  • An algorithm for detection of yellow sand aerosols has been developed with infrared bands. This algorithm is a hybrid algorithm that has used two methods combined. The first method used the differential absorption in brightness temperature difference between $11{\mu}m\;and\;12{\mu}m\;(BTD1)$. The radiation at $11{\mu}m$ is absorbed more than at $12{\mu}m$ when yellow sand is loaded in the atmosphere, whereas it will be the other way around when cloud is present. The second method uses the brightness temperature difference between $3.7{\mu}m\;and\;11{\mu}m(BTD2)$. This technique is sensitive to dust loading, which the BTD2 is enhanced by reflection of $3.7{\mu}m$ solar radiation. First the Principle Component Analysis (PCA), a form of eigenvector statistical analysis from the two methods, is performed and the aerosol pixel with the lowest 10% of the eigenvalue is eliminated. Then the aerosol index (AI) from the combination of BTD 1 and 2 is derived. We applied this method to Multi-functional Transport Satellite-l Replacement (MTSAT-1R) data and obtained that the derived AI showed remarkably good agreements with Ozone Mapping Instrument (OMI) AI and Moderate Resolution Imaging Spectroradiometer (MODIS) aerosol optical depth.

GEMS 영상과 기계학습을 이용한 산불 연기 탐지 (Detection of Wildfire Smoke Plumes Using GEMS Images and Machine Learning)

  • 정예민;김서연;김승연;유정아;이동원;이양원
    • 대한원격탐사학회지
    • /
    • 제38권5_3호
    • /
    • pp.967-977
    • /
    • 2022
  • 산불의 발생과 강도는 기후 변화로 인하여 증가하고 있다. 산불 연기에 의한 배출가스 대기질과 온실 효과에 영향을 미치는 주요 원인 중 하나로 인식되고 있다. 산불 연기의 효과적인 탐지를 위해서는 위성 산출물과 기계학습의 활용이 필수적이다. 현재까지 산불 연기 탐지에 대한 연구는 구름 식별의 어려움 및 모호한 경계 기준 등으로 인한 어려움이 존재하였다. 본 연구는 우리나라 환경위성 센서인 Geostationary Environment Monitoring Spectrometer (GEMS)의 Level 1, Level 2 자료와 기계학습을 이용한 산불 연기 탐지를 목적으로 한다. 2022년 3월 강원도 산불을 사례로 선정하여 산불 연기 레이블 영상을 생성하고, 랜덤 포레스트 모델에 GEMS Level 1 및 Level 2 자료를 투입하여 연기 픽셀 분류 모델링을 수행하였다. 훈련된 모델에서 입력변수의 중요도는 Aerosol Optical Depth (AOD), 380 nm 및 340 nm의 복사휘도 차, Ultra-Violet Aerosol Index (UVAI), Visible Aerosol Index (VisAI), Single Scattering Albedo (SSA), 포름알데히드, 이산화질소, 380 nm 복사휘도, 340 nm 복사휘도의 순서로 나타났다. 또한 2,704개 픽셀에 대한 산불 연기 확률(0≤p≤1) 추정에서 Mean Bias Error (MBE)는 -0.002, Mean Absolute Error (MAE)는 0.026, Root Mean Square Error (RMSE)는 0.087, Correlation Coefficient (CC)는 0.981의 정확도를 보였다.

지상원격탐사를 이용한 에어러솔 간접효과 연구 (Aerosol Indirect Effect Studies derived from the Ground-based Remote Sensings)

  • 김병곤;권태영
    • 한국대기환경학회지
    • /
    • 제22권2호
    • /
    • pp.235-247
    • /
    • 2006
  • Aerosol indirect radiative forcing of climate change is considered the most uncertain forcing of climate change over the industrial period, despite numerous studies demonstrating such modification of cloud properties and several studies quantifying resulting changes in shortwave radiative fluxes. Detection of this effect is made difficult by the large inherent variability in cloud liquid water path (LWP): the dominant controlling influence of LWP on optical depth and albedo masks any aerosol influences. Here we have used ground-based remote sensing of cloud optical depth (${\tau}_c$) by narrowband radiometry and LWP by microwave radiometry to determine the dependence of optical depth on LWP, thereby permitting examination of aerosol influence. The method is limited to complete overcast conditions with liquid-phase single layer clouds, as determined mainly by millimeter wave cloud radar. The results demonstrate substantial (factor of 2) day-to-day variation in cloud drop effective radius at the ARM Southern Great Plains site that is weakly associated with variation in aerosol loading as characterized by light-scattering coefficient at the surface. The substantial scatter suggests the importance of meteorological influences on cloud drop size as well, which should be analyzed in the further intensive studies. Meanwhile, it is notable that the decrease in cloud drop effective radius results in marked increase in cloud albedo.

환원기화 원자 흡광광도법에 의한 대기분진중의 총 셀렌의 정량 (Hydride Generation-Atomic Absorption Spectrophotometric Determination of Total Selenium in Atmospheric Particulate)

  • 이용근;최건형;이동수;황규자
    • 한국대기환경학회지
    • /
    • 제6권2호
    • /
    • pp.147-154
    • /
    • 1990
  • A sensitive method for the determination of total selenium in aerosol particles is described. The method involves dissolution of aerosol particles by $HNO_3-HClO_4$ mixed acids, pre-reduction of Se (VI) to Se (IV) by boiling hydrochloric acid, and hydride generation followed by atomic absorption detection. Dissolved Se (IV) in 4M hydrochloric acid is reacted with $NaBH_4$ to form $H_2Se$, which is subsequently collected in an U-tube cooled in liquid nitrogen. Upon the completion of $H_2Se$ generation, the collected $H_2Se$ is rapidly vaporized into a quartz cuvette burner by removing the U-tube from liquid nitrogen, atomized, and then detected by an atomic absorption spectrophotometer. The absolute sensitivity of the method is 0.49 ng/0.0044 Abs. The accuracy of the method evaluated by analyzing standard reference materials for urban aerosol is better than 10%. Analytical results for urban and rural aerosol particles are reported.

  • PDF

Detection of Asian Dust Air-mass based on Short Wavelength Observation of SeaWiFS

  • Fukushima, H.;Hagihara, Y.;Hoshikuma, Y.;Ohta, S.;Uno, I.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1203-1205
    • /
    • 2003
  • To detect dust-loaded air-mass over land and ocean, we propose an index, which is essentially the difference in Rayleigh-corrected reflectance between 412 and 443 nm bands of SeaWiFS. Radiative transfer simulations are conducted to show that the index is linearly related to the optical thickness of modeled dust-contaminated aerosol while showing insensitivity against non-absorbing model aerosols. Asian SeaWiFS data set of 2001 spring is used to produce daily composite imagery of the index, which compares well with TOMS Aerosol Index and with predicted aerosol optical thickness predicted by CFORS chemical weather forecast.

  • PDF

Modelling of Aerosol Vertical Distribution during a Spring Season at Gwangju, Korea

  • Shin, Sung-Kyun;Lee, Kwon-Ho
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권1호
    • /
    • pp.13-21
    • /
    • 2016
  • The vertical distributions of aerosol extinction coefficient were estimated using the scaling height retrieved at Gwangju, Korea ($35.23^{\circ}N$, $126.84^{\circ}E$) during a spring season (March to May) of 2009. The aerosol scaling heights were calculated on a basis of the aerosol optical depth (AOD) and the surface visibilities. During the observation period, the scaling heights varied between 3.55 km and 0.39 km. The retrieved vertical profiles of extinction coefficient from these scaling heights were compared with extinction profile derived from the Light Detection and Ranging (LIDAR) observation. The retrieve vertical profiles of aerosol extinction coefficient were categorized into three classes according to the values of AODs and the surface visibilities: (Case I) the AODs and the surface visibilities are measured as both high, (Case II) the AODs and the surface visibilities are both lower, and (Others) the others. The averaged scaling heights for the three cases were $3.09{\pm}0.46km$, $0.82{\pm}0.27km$, and $1.46{\pm}0.57km$, respectively. For Case I, differences between the vertical profile retrieved from the scaling height and the LIDAR observation was highest. Because aerosols in Case I are considered as dust-dominant, uplifted dust above planetary boundary layer (PBL) was influenced this discrepancy. However, for the Case II and other cases, the modelled vertical aerosol extinction profiles from the scaling heights are in good agreement with the results from the LIDAR observation. Although limitation in the current modelling of vertical structure of aerosols exists for aerosol layers above PBL, the results are promising to assess aerosol profile without high-cost instruments.

CALIPSO위성 탑재 라이다를 이용한 동북아시아 지역의 대기 에어러솔 3차원 광학특성 분포 (3-D Perspectives of Atmospheric Aerosol Optical Properties over Northeast Asia Using LIDAR on-board the CALIPSO satellite)

  • 이권호
    • 대한원격탐사학회지
    • /
    • 제30권5호
    • /
    • pp.559-570
    • /
    • 2014
  • 위성 탑재 라이다 시스템이 관측하는 후방산란 신호는 대기 에어러솔의 3차원 공간적인 분포 특성 및 시간적인 변화를 탐지할 수 있게 한다. 본 연구에서는 Cloud-Aerosol LIDAR and Infrared Pathfinder Satellite Observation(CALIPSO) 위성에 탑재된 Cloud-Aerosol LIDAR with Orthogonal Polarization(CALIOP) 라이다 관측자료를 이용하여 2012년 한 해 동안의 동북아시아 지역(북위 20도 - 50도, 동경 110 도 - 140 도)의 대기 에어로졸의 시공간 분포를 분석하였다. 입자 소산계수와 편광소멸도의 통계 분석으로부터 각 고도별 에어러솔 입자의 광학 특성정보를 분석하였고, 각 계절별 에어러솔 광학 특성값의 연직분포정보를 정량화할 수 있었다. 또한, 편광소멸도 자료는 연중 0.5 이상의 큰 값을 보이고 있어 지역 대기에는 비구형성 입자에 의한 영향이 많이 받고 있음을 알 수 있었다. 본 연구는 지역적 규모의 3차원 에어러솔 분포 정보에 대한 기초연구로서, 향후 추가 자료 조사를 통하여 보다 다양한 이벤트성 사례와 에어러솔 기후학적 정보를 생산할 것이다.

Raman Lidar for the Measurement of Temperature, Water Vapor, and Aerosol in Beijing in the Winter of 2014

  • Tan, Min;Shang, Zhen;Xie, Chenbo;Ma, Hui;Deng, Qian;Tian, Xiaomin;Zhuang, Peng;Zhang, Zhanye;Wang, Yingjian
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.15-22
    • /
    • 2018
  • To measure atmospheric temperature, water vapor, and aerosol simultaneously, an efficient multi-function Raman lidar using an ultraviolet-wavelength laser has been developed. A high-performance spectroscopic box that utilizes multicavity interference filters, mounted sequentially at small angles of incidence, is used to separate the lidar return signals at different wavelengths, and to extract the signals with high efficiency. The external experiments are carried out for simultaneous detection of atmospheric temperature, water vapor, and aerosol extinction coefficient in Beijing, under clear and hazy weather conditions. The vertical profiles of temperature, water vapor, and aerosol extinction coefficient are analyzed. The results show that for an integration time of 5 min and laser energy of 200 mJ, the mean deviation between measurements obtained by lidar and radiosonde is small, and the overall trend is similar. The statistical temperature error for nighttime is below 1 K up to a height of 6.2 km under clear weather conditions, and up to a height of 2.5 km under slightly hazy weather conditions, with 5 min of observation time. An effective range for simultaneous detection of temperature and water vapor of up to 10 km is achieved. The temperature-inversion layer is found in the low troposphere. Continuous observations verify the reliability of Raman lidar to achieve real-time measurement of atmospheric parameters in the troposphere.

에어로졸 중화기의 성능이 고하전 입자의 크기분포 측정에 미치는 영향 (Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1498-1507
    • /
    • 2003
  • A SMPS(scanning mobility particle sizer) system measures the number size distribution of particles using electrical mobility detection technique. An aerosol charge neutralizer, which is a component of the SMPS, is a bipolar charger using a radioactive source to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. In this study, the effect of the particle charging characteristics of two aerosol charge neutralizers on the measurement using a SMPS system was experimentally investigated for highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0.5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.3 to 3.0 L/min. The results show that the non-equilibrium character in particle charge distribution appears as the air flow rate increases although the particle number concentration is relatively low in the range of 1.5∼2x10$^{6}$ particles/㎤. The low neutralizing efficiency of the $^{85}$ Kr aerosol charge neutralizer for highly charged particles can cause to bring an artifact in the measurement using a SMPS system. However, the performance of the $^{210}$ Po aerosol charge neutralizer is insensitive to the air flow rate.