• 제목/요약/키워드: aerodynamic distribution

검색결과 284건 처리시간 0.022초

목재분진 농도 측정에 대한 37 mm closed-face 카세트법과 IPM 측정법 비교 (Comparison of Area vs Personal Total Dust Concentrations Measured by 37mm Closed-face Cassette and IPM Sampler)

  • 이동원;김현욱
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.67-76
    • /
    • 1996
  • This study was performed to estimate total dust concentrations and particle size distribution of wood dust in the furniture and sawmill industries. To compare total wood dust concentrations, two samplers recommended by the American Conference of Governmental Industrial Hygienists and by the National Institute for Occupational Safety and Health were used. Concentration data were analyzed by paired-t tests using the SAS program and two parameters of the particle size distributions were determined by histogram. The results were as follows: 1. Particle size distributions showed a unimodal pattern in cutting and a bimodal in sanding operations. Mass median aerodynamic diameters(MMAD) were $17.35{\mu}m$ in cutting, and $1.39{\mu}m$ for small mode and $18.89{\mu}m$ for large mode in sanding operations. The proportions of particle size larger than $9.8{\mu}m$ estimated by the impactor were 61.16 % in cutting and 62.33 % in sanding operations, respectively. 2. The average personal total dust concentrations measured by IPM sampler were $17.12mg/m^3$ (GSD=1.45) from indoor samples, $2.97mg/m^3$(GSD=1.90) from outdoor samples in cutting, and $8.01mg/m^3$(GSD=1.58) from sanding operation. And those of by 37 mm closed-face cassette were $9.12mg/m^3$(GSD=1.46), $1.06mg/m^3$(GSD=1.99) from cutting, and $3.32mg/m^3$(GSD=2.16) from sanding operations. 3. The average area total dust concentrations measured by IPM sampler were $1.88mg/m^3$(GSD=2.04) from indoor cutting, $4.76mg/m^3$(GSD=2.83) from indoor sanding operations. And those of by 37mm closed-face cassette were $0.49mg/m^3$(GSD=2.34) from cutting, and $1.32mg/m^3$(GSD=3.03) from sanding operations. 4. The ratio of personal total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 35.7 %, 53.3 % from cutting, and 41.4 % from sanding operations. 5. The ratio of area total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 26.1 % from cutting, and 27.7 % from sanding operations. 6. A statistically significant difference of total dust concentrations between the 37 mm closed-face cassette and the IPM sampler was found.

  • PDF

후두 미세수술 중 병변 내 스테로이드 주입이 음성에 미치는 효과 분석 (Analysis of the Effect of Intralesional Steroid Injection on the Voice During Laryngeal Microsurgery)

  • 박재선;강현석;이인범;진성민;이상혁
    • 대한후두음성언어의학회지
    • /
    • 제33권3호
    • /
    • pp.166-171
    • /
    • 2022
  • Background and Objectives Vocal fold (VF) scar is known to be the most common cause of dysphonia after laryngeal microsurgery (LMS). Steroids reduce postoperative scar formation by inhibiting inflammation and collagen deposition. However, the clinical evidence of whether steroids are helpful in reducing VF scar formation after LMS is still lacking. The purpose of this study is to determine whether intralesional VF steroid injection after LMS helps to reduce postoperative scar formation and voice quality. Materials and Method This study was conducted on 80 patients who underwent LMS for VF polyp, Reinke's edema, and leukoplakia. Among them, 40 patients who underwent VF steroid injection after LMS were set as the injection group, and patients who had similar sex, age, and lesion size and who underwent LMS alone were set as the control group. In each group, stroboscopy, multi-dimensional voice program, Aerophone II, and voice handicap index (VHI) were performed before and 1 month after surgery, and the results were statistically analyzed. Results There were no statistically significant differences in the distribution of sex, age, symptom duration, occupation and smoking status between each group. Both groups consisted of VF polyp (n=21), Reinke's edema (n=11), and leukoplakia (n=9). On stroboscopy, the lesion disappeared after surgery, and the amplitude and mucosal wave were symmetrical on both sides of the VFs in all patients. Acoustic parameters and VHI significantly improved after surgery in all patients. However, there was no significant difference between the injection and control group in most of the results. Conclusion There was no significant difference in the results of stroboscopy, acoustic, aerodynamic, and subjective evaluation before and after surgery in the injection group and the control group.

인광석 취급 산업체에서 발생하는 천연방사성물질 함유 입자의 특성 평가 (Characterization of Particulates Containing Naturally Occurring Radioactive Materials in Phosphate Processing Facility)

  • 임하얀;최원철;김광표
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.7-13
    • /
    • 2014
  • 인광석 취급 산업체에서는 천연방사성물질(NORM)을 함유한 물질을 다량으로 취급하고 있어, 종사자들은 각 공정에서 발생하는 공기 중 입자의 흡입에 의해 내부피폭을 받을 수 있다. 흡입에 의한 내부피폭 방사선량은 입자의 특성에 의해 크게 좌우된다. 따라서 본 연구에서는 국내 최대 인광석 취급 산업체에서 공기 중 부유 입자의 크기 분포 및 농도, 입자의 모양 및 밀도, 그리고 방사능 농도를 평가 하였다. 다단계입자채집기를 이용하여 공기 중 입자를 채집하고 입자의 크기분포, 농도, 그리고 모양을 분석하였다. 입자의 공기역학적 직경은 0.03-100 ${\mu}m$까지 광범위하게 분포하였으며, 입자크기가 4.7-5.8 ${\mu}m$(기하학적 평균직경 = 5.22 ${\mu}m$) 혹은 5.8-9.0 ${\mu}m$(기하학적 평균직경 = 7.22 ${\mu}m$)인 범위에서 공기 중 입자의 농도가 최댓값을 나타냈다. 공기 중 부유입자의 농도는 공정에 따라 최대 수백 배 이상 차이를 보였으며, 중장비 작업이 이루어지는 창고에서 높은 농도를 보였다. 반면에 인산석고 적치장에서는 입자의 부유방지를 위한 덮개 및 살수 그리고 비료공장 제어실에서는 환기시설을 갖추고 있어 상대적으로 입자의 공기 중 농도가 낮게 나타났다. 입자의 모양은 모든 측정 장소에서 구형에 가깝게 나타났으므로, 인광석 취급 시설에서 발생하는 입자의 모양인자 값을 1로 정하였다. 각 공정에서 시료를 채집하여 입자의 밀도를 분석하였다. 인광석의 밀도는 약 3.1-3.4 $gcm^{-3}$, 염화칼륨의 밀도는 약 2.7 $gcm^{-3}$, 공정 부산물인 인산석고의 밀도는 약 2.1-2.6 $gcm^{-3}$, 최종제품인 복합비료의 밀도는 약 1.7 $gcm^{-3}$으로 나타났다. 감마분석기를 이용하여 원료물질, 공정부산물, 생산제품 내 $^{226}Ra$, $^{228}Ra$, $^{40}K$ 핵종의 방사능 농도를 측정하였다. 인광석에는 주로 우라늄계열 핵종을 많이 함유하고 있었으며, 그 농도는 원료 산지에 따라 94-866 $Bqkg^{-1}$ 정도였다. 인광석 내에 존재하는 우라늄계열 핵종 중 우라늄은 생산품인 인산 혹은 비료에 농축되었으며, 라듐은 부산물인 인산석고에 농축되었다. 최종제품인 비료의 경우에는 $^{226}Ra$$^{228}Ra$이 거의 존재하지 않았으나, 제품생산을 위해 첨가한 염화칼륨에 의해 $^{40}K$의 방사능 농도가 5,000 $Bqkg^{-1}$로 높게 나타났다. 본 연구에서 생산한 인광석 취급 산업체의 입자의 특성 평가 자료는 인산염 취급 산업체 종사자에 대한 방사선학적 안전성 평가에 이용될 수 있을 것이며, 최근 시행된 생활주변방사선 안전관리법에 따른 생활주변방사선 안전관리의 체계를 수립하기 위한 자료로 활용될 수 있을 것이다.

PM10 질량농도 측정을 위한 시료채취기의 비교 연구 (A Comparison Study of Aerosol Samplers for PM10 Mass Concentration Measurement)

  • 박주면;구자건;정태영;권동명;유종익;서용칠
    • 대한환경공학회지
    • /
    • 제31권2호
    • /
    • pp.153-160
    • /
    • 2009
  • PM10(공기역학 직경${\leq}$10 ${\mu}m$) 시료채취기는 사람이 부유 먼지에 잠재적으로 노출되는 정도를 정량화하고 정부의 규제에 대응하기 위한 목적으로 사용된다. 본 연구는 동일한 PM10 분리한계 직경을 가지지만 다른 기울기를 가지는 미국 환경청의 PM10 시료채취 기준과 미국산업위생전문가협의회/유럽표준위원회/국제표준기구의 흉곽성 PM10 시료채취 기준을 이론과 실험을 통해 비교 평가하고자 수행되었다. 이를 위해 미국 환경청의 기준을 따르는 4개의 PM10 시료채취기와 흉곽성 PM10 기준과 일치하는 1개의 RespiCon 시료채취기를 비교 평가 수단으로 사용하였으며, 1개의 DustTrak 측정기를 PM10의 실시간 질량농도를 확인하기 위하여 사용하였다. 6개 시료채취기를 다양한 크기 분포를 가지는 비산재를 이용하여 입자 발생 챔버안에서 실험하였다. 이론적 질량농도는 측정된 비산재의 입자크기 분포 특성(기하평균 = 6.6 ${\mu}m$, 기하표준편차= 1.9)을 각 시료채취 기준에 적용하여 계산하였다. 챔버 실험을 통하여 측정된 질량농도 결과는 흉곽성 PM10 시료채취 기준을 가지는 RespiCon 시료채취기가 미국 환경청의 PM10 기준을 가지는 PM10 시료채취기보다 상대적으로 작은 질량농도를 측정함으로써 이론적 질량농도와 일치하였다. 전체적 챔버 실험 결과는 PM10 시료채취기를 기준 시료채취기로 사용하였을 때, (1) RespiCon 시료채취기는 PM10 시료채취기로 포집된 PM10 먼지 질량농도에 비해 평균 60% 정도 낮게 측정한 것을 의미하는 정규화계수 1.6으로 나타났으며 (2) PM10 유입구를 사용한 DustTrak 실시간 채취기는 2.1의 보정계수를 가지는 것으로 분석되었다.