• Title/Summary/Keyword: adult images

Search Result 168, Processing Time 0.021 seconds

The Risk of Cervical Spine Injuries among Submersion Patients in River (강에서 발생한 익수 환자의 경추손상 위험도)

  • Kim, Suk Hwan;Choi, Kyung Ho;Choi, Se Min;Oh, Young Min;Seo, Jin Sook;Lee, Mi Jin;Park, Kyu Nam;Lee, Won Jae
    • Journal of Trauma and Injury
    • /
    • v.19 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • Purpose: Recently, the American Heart Association recommended that routine cervical spine protection in submerged patients was not necessary, except in high-energy injury situations. However, until now, this recommendation has few supportive studies and literatures. This retrospective study was performed to demonstrate the risk of cervical spine injury in patients who had been submerged in a river. Methods: Seventy-nine submerged patients who visited St. Mary's Hospital between January 2000 and December 2005 were included in this retrospective study. We investigated and analyzed the victim's age, sex, activity on submersion, mental status and level of severity at admission, prognosis at discharge, associated injuries, and risk group by using the medical records and cervical spine lateral images. According to the activity on submersion, victims were classified into three groups: high risk, low risk, and unknown risk. The reports of radiologic studies were classified into unstable fracture, stable fracture, sprain, degenerative change, and normal. Results: The patients' mean age was 36.8 yrs, and 54% were males. Of the 79 patients, adult and adolescent populations (80%) were dominant. Jumping from a high bridge (48%) was the most common activity on submersion and accounted for 52% of the high-risk group. The Glasgow coma scale at admission and the cerebral performance scale at discharge showed bimodal patterns. The results of the radiologic studies showed one stable fracture, one suspicious stable fracture, and 18 sprains. The incidence of cervical spine fracture in submerged patients was 2.5% in our study. The incidence of cervical spine injury was higher in the high-risk group than it was in the low-risk group, especially in the jumping-from-high-bridge subgroup; however this observation was not statistically significant. No other factors had any significant effect on the incidence of cervical spine injury. Conclusion: Our study showed that even submerged patients in the high risk group had a low incidence of cervical spine fracture and that the prognosis of a patient did not seem to be influenced by the cervical spine fracture itself.

Lip and perioral soft tissue changes after bracket bonding using 3-D laser scanner (브라켓의 접착 전후 입술 주위 연조직의 3차원적 변화)

  • Lee, Won-Je;Lee, Kee-Joon;Yu, Hyung-Seog;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.411-422
    • /
    • 2011
  • Objective: The aim of this study was to evaluate the lip and perioral soft tissue changes after bracket bonding. Methods: The soft tissue changes in 45 adult patients (age greater than 18 years and less than 29 years) without severe skeletal discrepancy were evaluated using three-dimensional images acquired with a laser scanner before and after bracket bonding was performed using 4 types of labial orthodontic brackets. Results: Among the statistically significant changes in distance observed for the landmarks, the biggest change was observed in forward movement. The landmarks on the lateral sides also showed significant changes. While the landmarks on the upper lip showed significant upward movement, those on the lower lip showed significant downward movement. However, the changes were smaller for the landmarks on the upper lip (average, 0.87 mm) than for the landmarks on the lower lip (average, 1.21 mm). The type of bracket used did not significantly affect the soft tissue changes. Conclusions: These findings will help predict soft tissue changes after bracket bonding for orthodontic treatment.

A Study on 'Evolution' of Animation Images : Centered around Characters of Monster Animation and (애니메이션 이미지의 '진화'에 관한 연구 : 몬스터 애니메이션 <포켓몬스터>와 <디지몬>의 캐릭터를 중심으로)

  • Kim, Yoon-A
    • Cartoon and Animation Studies
    • /
    • s.18
    • /
    • pp.37-56
    • /
    • 2010
  • This paper focalizes on the 'evolution' of monster animation and . Actually, Many characters' 'Evolution' is a very powerful convention of Japanese genre animation. Lots of young people feel a huge pleasure about character's evolution. It is a fantastic spectacle to boys and girls. The first characteristic point of characters' evolution is growing-up body to an adult. For example, magical girls genre shows a woman's sexy body. This scene gives a sexual fantasy to young girl spectators, a voyeuristic visual pleasure to young boy spectators. The second point is that a transforming-body gains some super power or magical power. The third point is that a great many characters is in one text. In , characters' numbers go on increasing through 6 ways-hybrid type, mutant-reiteration type, metamorphosis type, simple-grownup type, narrative type, multiple evolution type. The evolution of has to pay attention to only one transforming way. Most Digimon characters are becoming to a human-weapons cyborg. In my opinion, this is very dangerous phenomenon with a political ideology.

  • PDF

Comparison of Direct Digital Radiography and Conventional Film Screen Radiography for Detection of Peritoneal Fluid in Dogs (개에서 복수의 평가에 있어서 필름-증감지 방사선 사진과 디지털 방사선 사진의 비교)

  • Choi, Ho-Jung;O, I-Se;Lee, Ki-Ja;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.18-22
    • /
    • 2012
  • This study was performed to evaluate the sensitivity of conventional film-screen radiography (CFSR) and direct digital radiography (DDR) for detection of various amounts of free peritoneal fluid. Ten adult male healthy beagles were used in this study. Radiographic examinations were performed in the right lateral and ventrodorsal positions. Fluid was injected in increments of 2.0 ml/kg of body weight up to 20.0 ml/kg of body weight. The images of CFSR and DDR were evaluated by two veterinary radiologists for evidence of abdominal fluid without knowledge of injected fluid volume. Data were evaluated by using the receiver operation curve (ROC) analysis and the area under the curve (AUC). There was no significant difference in detection of peritoneal fluid between DDR and CFSR in the ROC analysis. The accuracy of CFSR (0.805) was relatively higher than that of DDR (0.733), based on the ROC analysis and AUC. AUC of CFSR was higher in most injection doses. These results suggest that CFSR is more accurate than DDR for the detecting peritoneal fluid. Therefore, for situation in which digital radiographs are equivocal or small amount of fluid is suspected, other imaging modalities, such as ultrasonography would be helpful for determining the presence of fluids.

An Ultrastructural Study on the Epithelial Cells of the Rabbit Gallbladder after Common Bile Duct Ligation (총담관 결찰후 집토끼 담낭상피세포의 미세구조적 변화)

  • Yim, Soo-Jae;Yang, Nam-Gil;Ahn, E-Tay;Ko, Jeong-Sik;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.22 no.2
    • /
    • pp.15-29
    • /
    • 1992
  • The gallbladder is known to have the function of the storage and the concentration of the bile produced by the liver. This function is carried out by the removal of water and inorganic electrolytes. Extrahepatic cholestasis or the impairment of excretion of the bile leads to the distension and loss of the function of the gallbladder. The purpose of this study was to examine the ultrastructural characteristics of the normal gallbladder epithelial cells, and their structural changes induced by the ligation of common bile duct of the rabbit. Common bile duct ligation was performed under ether anesthesia. The rabbits were sacrificed on the 1st, 3rd, 5th, 7th and 14th day, respectively after operations. The tissue blocks of the gallbladder were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde prior to fixation in 1% osmium tetroxide, and embedded in the araldite mixture, and observed with JEM 100 CX-II electron microscope. The results were as follows: 1. The normal gallbladder epithelium of adult rabbit demonstrated two cell types, the ordinary epthelial cell and the dark cell. The dark cells have electron dense cytoplasm, and were found much infrequently, whereas ordinary epthelial cells were found quite numerous. 2. The ordinary epthelial cells of normal gallbladder were provided with the regular microvilli at the free surface and the images of pinocytotic activities in the apical cytoplasm, and exhibit highly convoluted lateral surfaces with elaborated microfolds. These figures of the cells suggest that they are resorptive in functional activity. 3. In the early stages (1st, 3rd, 5th day groups) following the ligation, the apical cytoplasm of some cells is protruding from the free surface and lost their microvilli. Numerous mucous granules filled in the apical and supranuclear cytoplasm compactly. 4. In the late stages (7th, 14th day groups) following the ligation, many light cells containing mumerous mucous granules are seen, between the ordinary epthelial cells. Mucous granules are fused each other, and are discharged into the lumen from the apical cytoplasm. The lateral membranes are straight or undulating without any interdigitations. From the above results, it was concluded that in the cholestasis induced by the common bile duct ligation, there is a tendency for the mucosal epithelium of the rabbit gallbladder to have secretory rather than an absorptive function.

  • PDF

Cross-sectional study of the mandibular body in patients with facial asymmetry (안면 비대칭환자의 하악골체부의 시상 단면에 관한 연구)

  • Lee, Jae-Yeo;Kim, Yong-Il;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Uk-Kyu;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.2
    • /
    • pp.109-113
    • /
    • 2011
  • Introduction: To correct the facial asymmetry by mandibular jaw surgery, it is important to know the anatomy of the mandible including the mandibular canal positioning of patients with facial asymmetry. This study was performed to evaluate the differences in the cross-sectional surface in the body of the mandible between the deviated side and opposite side in patients with facial asymmetry. Materials and Methods: The study was conducted on 37 adult patients composed of 2 groups, the asymmetry group (n=20) and non-asymmetry group (n=17). Using the cross-sectional computed tomography (CT) images, the distance from the buccal aspect of the mandibular canal to the outer aspect of the buccal cortex, distance from the buccal aspect of the mandibular canal to the inner aspect of the buccal cortex, distance from the inferior aspect of the mandibular canal to the inferior border of the mandible, thickness of the mandible, and cross-sectional surface area of the mandible were measured in each side of the mandible Results: The cross-sectional area of the mandible including the mandibular canal positioning in the deviated side was not statistically different from the opposite side in the asymmetry group. Only the distance from the inferior aspect of the mandibular canal to the inferior border of the mandible in the ramus area of the deviated side was significantly longer than opposite side. On the other hand, the bucco-lingual width of the asymmetry group was thinner than the non-asymmetry group. Conclusion: The cross-sectional area including the mandibular canal of the mandible did not appear to be modified by the facial asymmetry.

Anatomic study of the incisive canal in relation to midpalatal placement of mini-implant (정중구개부의 미니 임플랜트 식립과 관련된 절치관의 해부학적 연구)

  • Kim, Sung-Jin;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.3
    • /
    • pp.146-158
    • /
    • 2009
  • Objective: The purpose of this study was to reveal the position of the incisive foramen in relation to the incisive papilla and cusp tips. Methods: Plaster models and CT images of 25 adult orthodontic patients were used to measure the width of the incisive canal and positions of the anterior and posterior borders of the incisive foramen in relation to the incisive papilla. Results: The palatal surface distance from the interdental papilla between the maxillary central incisors to the posterior border of the incisive foramen along the palatal surface was 1.7 fold of the distance from the interdental papilla between the central incisors to the posterior border of the incisive papilla. The distance between the posterior border of the incisive papilla and posterior border of the incisive foramen along the palatal surface was 6.15 ${\pm}$ 1.75 mm. The anteroposterior position of the posterior border of the incisive foramen was slightly anterior to the lingual cusp tips of the maxillary 1st premolars. The width of the incisive foramen was 4.03 ${\pm}$ 0.64 mm, therefore it is recommended to position the mini-implant more than 3 mm laterally when placing a mini-implant lateral to the incisive foramen, from the center. Conclusions: These results can be used as a reference in presuming the position of the incisive foramen when placing mini-implant in the anterior palate area.

Three dimensional cone-beam CT study of upper airway change after mandibular setback surgery for skeletal Class III malocclusion patients (Cone-beam CT를 이용한 골격성 III급 부정교합자의 하악골 후퇴술 후 상기도 변화에 관한 연구)

  • Kim, Na-Ri;Kim, Yong-Il;Park, Soo-Byung;Hwang, Dae-Seok
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.145-155
    • /
    • 2010
  • Objective: Lateral cephalometric radiographs have been the main form of resource for assessing two dimensional anteroposterior airway changes. The purpose of this study was to evaluate the three dimensional volumetric change in the upper airway space in Class III malocclusion patients who underwent mandibular setback surgery. Methods: Three dimensional cone-beam computed tomographs (CBCT) and their three dimensional reconstruction images were analyzed. The samples consisted of 20 adult patients (12 males and 8 females) who were diagnosed as skeletal Class III and underwent mandibular setback surgery. CBCTs were taken at 3 stages - Baseline (1.8 weeks before surgery), T1 (2.3 months after surgery), and T2 (1 year after surgery). Pharyngeal airway was separated according to the reference planes and reconstructed into the nasopharynx, the oropharynx and the hypopharynx. Measurements at Baseline, T1, and T2 were compared between groups. Results: The result showed the volume of the pharyngeal airway decreased significantly 2.3 months after surgery (p < 0.001) and the diminished airway did not recover after 1 year post-surgery. The oropharynx was the most decreased area. Conclusions: These findings suggest that mandibular setback surgery causes both short-term and long-term decrease in the upper airway space.

Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea (심장혈관 조영술과 심장혈관 인터벤션의 환자 선량 평가)

  • Kim, Jung-Su;Lee, Joun-Hyuk;Jung, Hae-Kyoung;Kim, Jung-Min;Cho, Byung Ryul
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • The use of cardiac angiography (CA) and the interventional procedures is rapidly increasing due to the increase in modern adult diseases. Cardiovascular intervention (CI) is an examination method where radiation is applied to the same area for a long period, and thus may cause skin injury. In this study, we investigate the diagnostic reference level (DRL) of the cardiovascular intervention (CI) carried out by medical institutions and use it as a tool to reduce patient exposure dose. In this study, the DRL was set by acquiring information about the cumulative fluoroscopy time, cumulative fluoroscopy dose-area product (DAP), radiography DAP, cumulative DAP, air kerma, number of video clips, and the total number of images from the cardiac angiography and interventional procedures performed on 147 patients. The DAPs corresponding to the DRL of cardiac angiography(CA) and that of the interventional procedures were shown to be $44.4Gy{\cdot}cm2$ and $298.6Gy{\cdot}cm2$, respectively; the corresponding DRLs of fluoroscopy time were shown to be 191.5s and 1935.3s, respectively. A DRL is not a strict upper bound for radiation exposure. However, the process of setting, enacting, and reviewing the DRLs for the dose by medical institutions will contribute to a reduction in the unnecessary exposure dose of patients.

Accuracy of posteroanterior cephalogram landmarks and measurements identification using a cascaded convolutional neural network algorithm: A multicenter study

  • Sung-Hoon Han;Jisup Lim;Jun-Sik Kim;Jin-Hyoung Cho;Mihee Hong;Minji Kim;Su-Jung Kim;Yoon-Ji Kim;Young Ho Kim;Sung-Hoon Lim;Sang Jin Sung;Kyung-Hwa Kang;Seung-Hak Baek;Sung-Kwon Choi;Namkug Kim
    • The korean journal of orthodontics
    • /
    • v.54 no.1
    • /
    • pp.48-58
    • /
    • 2024
  • Objective: To quantify the effects of midline-related landmark identification on midline deviation measurements in posteroanterior (PA) cephalograms using a cascaded convolutional neural network (CNN). Methods: A total of 2,903 PA cephalogram images obtained from 9 university hospitals were divided into training, internal validation, and test sets (n = 2,150, 376, and 377). As the gold standard, 2 orthodontic professors marked the bilateral landmarks, including the frontozygomatic suture point and latero-orbitale (LO), and the midline landmarks, including the crista galli, anterior nasal spine (ANS), upper dental midpoint (UDM), lower dental midpoint (LDM), and menton (Me). For the test, Examiner-1 and Examiner-2 (3-year and 1-year orthodontic residents) and the Cascaded-CNN models marked the landmarks. After point-to-point errors of landmark identification, the successful detection rate (SDR) and distance and direction of the midline landmark deviation from the midsagittal line (ANS-mid, UDM-mid, LDM-mid, and Me-mid) were measured, and statistical analysis was performed. Results: The cascaded-CNN algorithm showed a clinically acceptable level of point-to-point error (1.26 mm vs. 1.57 mm in Examiner-1 and 1.75 mm in Examiner-2). The average SDR within the 2 mm range was 83.2%, with high accuracy at the LO (right, 96.9%; left, 97.1%), and UDM (96.9%). The absolute measurement errors were less than 1 mm for ANS-mid, UDM-mid, and LDM-mid compared with the gold standard. Conclusions: The cascaded-CNN model may be considered an effective tool for the auto-identification of midline landmarks and quantification of midline deviation in PA cephalograms of adult patients, regardless of variations in the image acquisition method.