• Title/Summary/Keyword: adsorption method

Search Result 1,277, Processing Time 0.035 seconds

The Phase-Shift Method for the Langmuir Adsorption Isotherms at the Noble Metal (Au, Rh) Electrode Interfaces (귀금속(Au, Rh) 전극계면에서 Langmuir 흡착등온식에 관한 위상이동방법)

  • Chun, Jang H.;Jeon, Sang K.;Lee, Jae H.
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.119-129
    • /
    • 2003
  • The Langmuir adsorption isotherms of the over-potentially deposited hydrogen (OPD H) fur the cathodic $H_2$ evolution reaction (HER) at the poly-Au and $Rh|0.5M\;H_2SO_4$ aqueous electrolyte interfaces have been studied using cyclic voltammetric and ac impedance techniques. The behavior of the phase shift $(0^{\circ}{\leq}{-\phi}{\leq}90^{\circ})$ for the optimum intermediate frequency corresponds well to that of the fractional surface coverage $(1{\geq}{\theta}{\geq}0)$ at the interfaces. The phase-shift profile $({-\phi}\;vs.\;E)$ for the optimum intermediate frequency, i.e., the phase-shift method, can be used as a new electrochemical method to determine the Langmuir adsorption isotherm $({\theta}\;vs.\;E)$ of the OPD H for the cathodic HER at the interfaces. At the poly-Au|0.5M $H_2SO_4$ aqueous electrolyte interface, the equilibrium constant (K) and the standard free energy $({\Delta}G_{ads})$ of the OPD H are $2.3\times10^{-6}$ and 32.2kJ/mol, respectively. At the poly-Rh|0.5M $H_2SO_4$ aqueous electrolyte interface, K and ${\Delta}G_{ads}$ of the OPD H are $4.1\times10^4\;or\;1.2\times10^{-2}$ and 19.3 or 11.0kJ/mol depending on E, respectively. In contrast to the poly-Au electrode interface, the two different Langmuir adsorption isotherms of the OPD H are observed at the poly-Rh electrode interface. The two different Langmuir adsorption isotherms of the OPD H correspond to the two different adsorption sites of the OPD H on the poly-Rh electrode surface.

The Change of Adsorption Characteristics for VOCs by HNO3 Activation of Adsorbent Prepared from MSWI Fly Ash (질산을 이용한 Fly Ash 흡착제의 표면 활성화에 따른 VOCs 흡착 특성의 변화)

  • Shim Choon-Hee;Lee Woo-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.471-478
    • /
    • 2005
  • The objective of this research is to improve adsorption efficiency of adsorbent made from MSWI (Municipal Solid Waste Incinerator) ny ash by $HNO_3$ activation. The acidity and the basicity were determined by Boehm's method and the surface structure was studied by BET method with N2 adsorption. The adsorption properties were investigated with benzene and MEK (Methylethylketone). $HNO_3$ activation can modify the surface property of an adsorbent such as specific surface area, pore volume, and functional group. According to the results, the specific surface area of the adsorbent was increased from $309.2m^2/g\;to\;553.2 m^2/g$ by activation. Also oxygen-containing functional groups were formed on it.

The hydrogen adsorption of electrospun carbon fibers web involving transition metal (전이금속 함유 전기방사 된 탄소섬유 웹의 수소 흡장)

  • Im, Ji-Sun;Kim, Ju-Wan;Park, Soo-Jin;Kim, Young-Ho;Lee, Young-Seak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.77-80
    • /
    • 2007
  • To increase the capacity of hydrogen adsorption, transition metals were adopted as catalyst. The PAN-based CNFs involving transition metal were obtained by electrospinning method and heat treatment. To study the surface of carbon fibers, SEM analysis was conducted. The mass of transition metals were spreaded or covered among CNFs. XRD and EDX analysis were used to confirm transition metals on the surface of carbon fibers. Volumetric method was used for studying the capacity of hydrogen adsorption on the carbon fibers involving transition metals. In this study. vanadium has the best characteristics among chromium, titanium, and copper for hydrogen adsorption.

  • PDF

EFFECTS OF VARIOUS SURFACE TREATMENTS FOR TITANIUM ON SURFACE MICRO ROUGHNESS, STATIC WETTABILITY, FIBRONECTIN ADSORPTION (표면 처리 방법에 따른 타이타늄의 미세 표면 거칠기, 표면 젖음성, fibronectin 흡착량에 미치는 영향)

  • Shin Hwa-Sub;Kim Young-Su;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.443-454
    • /
    • 2006
  • Purpose: This study aims to get the fundamental data which is necessary to the development direction of implant surface treatment hereafter, based on the understanding the surface structure and properties of titanium which is suitable for the absorption of initial tissue fluid by researching effects of additional surface treatments fir sandblasted with large git and acid-etched(SLA) titanium on surface micro-roughness, static wettability, fibronectin adsorption Materials and Method: In the Control groups, the commercial pure titanium disks which is 10mm in diameter and 2mm in thickness were treated with HCI after sandblasting with 50$\mu$m $Al_2O_3$. The experiment groups were made an experiment each by being treated with 1) 22.5% nitric acid according to SLA+ASTM F86 protocol, 2) SLA+30% peroxide, 3) SLA+NaOH, 4) SLA+ Oxalic acid, and 5) SLA+600$^{\circ}C$ heating. In each group, the value of Ra and RMS which are the gauges of surface roughness was measured, surface wettability was measured by analyzing with Sessile drop method, and fibronectin adsorption was measured with immunological assay. The significance of each group was verified by (SPSS, ver.10.0 SPSS Inc.) Kruskal-Wallis Test. (α=0.05) And the correlation significance between Surface micro-roughness and surface wettability. surface roughness and fibronectin adsorption, and surface wettability and fibronectin adsorption was tested by Spearman's correlation analysis. Result: All measure groups showed the significant differences in surface micro-roughness, surface wettability, and fibronectin adsorption. (p<0.05) There was no significance in correlation among the surface micro-roughness, surface wettability, and fibronectin adsorption. (p>0.05) Conclusion: Surface micro-roughness and surface wettability rarely affected the absorption of initial tissue fluid on the surface of titanium.

Application of Adsorption Sampling and Thermal Desorption with GC/MS Analysis for the Measurement of Low-Molecular Weight PAHs in Ambient Air (환경대기 중 저분자 PAHs 측정을 위한 흡착-열탈착-GC/MS 방법의 적용)

  • Seo, Seok-Jun;Seo, Young-Kyo;Hwang, Yoon-Jung;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.362-377
    • /
    • 2014
  • Polycyclic aromatic hydrocarbons (PAHs) have been of particular concern since they are present both in the vapor and particulate phases in ambient air. In this study, a simple method was applied to determine the vapor phase PAHs, and the performance of the new method was evaluated with a conventional method. The simple method was based on adsorption sampling and thermal desorption with GC/MS analysis, which is generally applied to the determination of volatile organic compounds (VOCs) in the air. A combination of Carbotrap (300 mg) and Carbotrap-C (100 mg) sorbents was used as the adsorbent. Target compounds included two rings PAHs such as naphthalene, acenaphthylene, and acenaphthene. Among them, naphthalene was listed as one of the main HAPs together with a number of VOCs in petroleum refining industries in the USA. For comparison purposes, a method based on adsorption sampling and solvent extraction with GC/MS analysis was adopted, which is in principle same as the NIOSH 5515 method. The performance of the adsorption sampling and thermal desorption method was evaluated with respect to repeatabilities, detection limits, linearities, and storage stabilities for target compounds. The analytical repeatabilities of standard samples are all within 20%. Lower detection limits was estimated to be less than 0.1 ppbv. In the results from comparison studies between two methods for real air samples. Although the correlation coefficients were more than 0.9, a systematic difference between the two groups was revealed by the paired t-test (${\alpha}$=0.05). Concentrations of two-rings PAHs determined by adsorption and thermal desorption method consistently higher than those by solvent extraction method. The difference was caused by not only the poor sampling efficiencies of XAD-2 for target PAHs and but also sample losses during the solvent extraction and concentration procedure. This implies that the levels of lower molecular PAHs tend to be underestimated when determined by a conventional PAH method utilizing XAD-2 (and/or PUF) sampling and solvent extraction method. The adsorption sampling and thermal desorption with GC analysis is very simple, rapid, and reliable for lower-molecular weight PAHs. In addition, the method can be used for the measurement of VOCs in the air simultaneously. Therefore, we recommend that the determination of naphthalene, the most volatile PAH, will be better when it is measured by a VOC method instead of a conventional PAH method from a viewpoint of accuracy.

Improved Method for the Preparation of Crude Ginseng Saponin (인삼 조사포닌의 조제 방법 개선)

  • 김시관;곽이성
    • Journal of Ginseng Research
    • /
    • v.22 no.3
    • /
    • pp.155-160
    • /
    • 1998
  • This stuffy was carried to establish a new efficient method for the preparation of edible crude ginseng saponin. The conventional butanol extraction and resin adsorption methods were compared for the contents of total crude ginseng saponin and major ginsenosides. Seventy- percent methanol extract was applied to Diaion HP-20 column and the resin was washed with Hn and eluted with absolute methanol. The methanol elute was dried in vivo and analyzed for its ginsenosides. Use of ethanol instead of methanol to make edible crude ginseng saponin gave a similar result. Butanol extraction was performed by the conventional method. The final aqueous layer from butanol extraction was passed through Diaion HP-20 column followed by elution with methanol and Diaion HP-20 passed fraction was extracted with butanol to recover remaining components, respectively, in order to determine saponin loss. TLC and HPLC qualitatively and quantitatively monitored Ginsenosides, respectively. Loss of ginsenosides was higher in butanol extraction method than in Diction HP-20 adsorption method. In addition, saponin fractions prepared by Diction HP-20 adsorption method showed higher content of each ginsenoside, showing 8.2% higher purity than that of butanol extracted fraction. From these results, we propose the resin adsorption method as a new efficient measure for the preparation of crude ginseng saponin, which is edible by using spirit instead of methanol.

  • PDF

The comparison of the adsorption characteristic of heavy metals onto soil mixed with food compost using retardation coefficient (지연계수를 이용한 음식물 퇴비 혼합 토양의 중금속 흡착특성 비교)

  • Joo, You-Yoen;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.245-250
    • /
    • 2008
  • Adsorption experiment was carried out to find the adsorption capacity and characteristics of heavy metals(Cd, Pb) onto soil and mixed soil with food compost. Result showed that mixed soil having higher organic content adsorbed more heavy metal than soil, indicating that food compost can be used effectively to prevent soil pollution. Linear adsorption isotherm which adopted to find the adsorption characteristics was used to calculate Retardation Factor(R). The value of Retardation Factor(R)s of Pb and Cd in mixed soil, found as 34.54, 24.42 respectively, are higher than those in soil which were found as 4.64, 3.67, respectively. The value of Retardation Factor(R) using Freundlich adsorption isotherm could be presented by the functions of concentration and showed similar result as the linear one. But Freundlich adsorption isotherm showed higher relationship than linear one and the retardation factor(R) from freundlich adsorption isotherm was thought as more effective method to assess adsorption capacity because it could reflect gradient and intercept of the isotherm.

Removal of Chromium by Activated Carbon Fibers Plated with Copper Metal

  • Park, Soo-Jin;Jung, Woo-Young
    • Carbon letters
    • /
    • v.2 no.1
    • /
    • pp.15-21
    • /
    • 2001
  • In this work, activated carbon fibers (ACFs) were plated with copper metal using electroless plating method and the effects of surface properties and pore structures on chromium adsorption properties were investigated. Surface properties of ACFs have been characterized using pH and acid/base values. BET data with $N_2$ adsorption were used to obtain the structural parameters of ACFs. The electroless copper plating did significantly lead to a decrease in the surface acidity or to an increase in the surface basicity of ACFs. However, all of the samples possessed a well-developed micropore. The adsorption capacity of Cr(III) for the electroless Cu-plated ACFs was higher than that of the as-received, whereas the adsorption capacity of Cr(VI) for the former was lower than that of the latter. The adsorption rate constants ($K_1$, $K_2$, and $K_3$) were also evaluated from chromium adsorption isotherms. It was found that $K_1$ constant for Cr(III) adsorption depended largely on surface basicity. The increase of Cr(III) adsorption and the decrease of Cr(VI) adsorption were attributed to the formation of metal oxides on ACFs, resulting in increasing the surface basicity.

  • PDF

Adsorption Property of Silicone Rubber Sticking Chuck for OLED Glass Substrate

  • Kim, Jin-Hee;Chung, Kyung-Ho
    • Elastomers and Composites
    • /
    • v.50 no.1
    • /
    • pp.55-61
    • /
    • 2015
  • Manufacturing process of OLED contains adsorption-desorption process of glass substrate. There are several adsorption methods of glass substrate such as atmospheric pressure, vacuum and electrostatic adsorption. However, these methods are very complex to connect system. Therefore, the adsorption method using silicone rubber based sticking chuck was proposed in this study. Three types of silicone rubbers having 0, 19.3 and 32.2 wt% of fluorine were used and their mechanical properties, surface energies and adsorption properties were examined. According to the results ${\sigma}_{300}$ and hardness increased with increasing fluorine contents, but elongation was decreased. Also, fluorosilicone rubber containing 32.2 wt% of fluorine showed the lowest surface tension, among three types of rubber and resulted in the highest initial tack with glass substrate. After the adsorption-desorption test of 300,000 cycles was performed, the adsorption force of S-1 (silicone rubber) decreased largely from 2.34 to 0.73 MPa. However, the S-3 (fluorosilicone rubber having 32.2 wt%. of fluorine) decreased only from 3.15 to 2.24 MPa. From this study, we obtained the valuable equations related to long term durability of silicone based sticking chuck. Finally the transfer of silicone rubber to glass substrate with the adsorption-desorption process was not occurred and this phenomenon was examined by UV-Visible spectroscopy.

Fabrication of Iron Oxide Nanotubes by Anodization for Phosphorus Adsorption in Water (양극산화 공정을 이용한 Iron Oxide Nanotubes의 제조 및 수중 인 흡착)

  • Lee, Won-Hee;Lim, Han-Su;Kim, Jong-Oh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.691-698
    • /
    • 2016
  • This study was carried out to investigate the characterization of iron oxide nanotubes (INTs) by anodization method and applied adsorption isotherms and kinetic models for phosphate adsorption. SEM analysis was conducted to examine the INTs surface formation. Further XRD and XPS analysis were performed to observe the crystal structure of INTs before and after phosphate adsorption. AFM analysis was conducted to determine of Fe foil surface before and after anodization. Phosphate stock solution for adsorption experiment was prepared by $KH_2PO_4$. The batch experiment was conducted using 20 ml phosphate stock solution and $40cm^3$ of INTs in 50 ml conical tube. Adsorption isotherms were applied Langmuir and Freundlich models for adsorption equilibrium test of INTs. Pseudo first order and pseudo second order models were applied for interpretation of adsorption rate by reaction time. The determination coefficient ($R^2$) values of Langmuir and Freundlich models were 0.9157 and 0.8876 respectively.