• Title/Summary/Keyword: adsorbents

Search Result 491, Processing Time 0.024 seconds

Decomposition of Acetonitrile by Planar Type Dielectric Barrier Discharge Reactor (평판형 유전체 장벽 방전 반응기에서 Acetonitrile의 분해 특성)

  • 송영훈;김관태;류삼곤;이해완
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.105-112
    • /
    • 2002
  • A combined process of non-thermal plasma and catalytic techniques has been investigated to treat toxic gas compounds in air. The treated gas in the present study is $CH_3$CN that has been known to be a simulant of toxic chemical agent. A planar type dielectric barrier discharge(DBD) reactor has been used to generate non-thermal plasma that produces various chemically active species, O, N, OH, $O_3$, ion, electrons, etc. Several different types of adsorbents and catalysts, which are MS 5A, MS 13X, Pt/alumina, are packed into the plasma reactor, and have been tested to save power consumption and to treat by-products. Various aspects of the present techniques, which are decomposition efficiencies along with the power consumption, by-product analysis, reaction pathways modified by the adsorbents and catalysts, have been discussed in the present study.

Evaluation of the Measurement of Trace Phenols by Adsorption/Thermal Desorption/Gas Chromatography/Mass Spectrometry (ATD/GC/MS) in Artificial Air (흡착관/열탈착 GC/MS 방법에 의한 모사시료 중의 미량 페놀 분석에 관한 평가)

  • 허귀석;이재환;황승만;정필갑;유연미;김정우;이대우
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.2
    • /
    • pp.127-137
    • /
    • 2002
  • Phenolic compounds in air are toxic even at their low concentrations. We had evaluated a total of five phenolic compounds (Phenol, o-Cresol, m-Cresol, 2-Nitrophenol and 4-Chloro-3-methylphenol) in artificial air using a combination of ATD/GC/MS. To compare the adsorption efficiency of these phenolic compounds, three adsorbents (Tenax TA, Carbotrap and Carbopack B) were tested. Tenax TA adsorbent was most effective of all the adsorbents used for the efficiency test. Five phenolic compounds were found to be very stable on adsorbent tubes for 4 days at room temperature. Detection limit of five phenolic compounds ranged from 0.05 to 0.08 ppb (when assumed to collect 10 L air). The calibration curve was linear over the range of 22∼ 164 ng. The reproducibility was less than 4%. Sampling of duplicate pairs (DPs) was made to demonstrate duplicate precision and sampling efficiency.

A Study on the Adsorption of Heavy Metals in Waste Water using Domestic Clays (검토를 이용한 폐수 중 중금속 흡착에 관한 연구)

  • Bae, Jang-Soon;Park, Chan-Kyo;Sung, Ki-Chun;Lee, Seok-Woo;Hwang, Yong-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.124-131
    • /
    • 2004
  • The adsorption of heavy metals in the waste water carried out on the various domestic clays and waste pottery. The effect of parameters such as pH, temperature, adsorption time and coexisting cations on the adsorption ability and characteristics were investigated to find out whether the clays could be used as adsorbents. Adsorption equilibrium was reached within 20 minutes on all the clays. The optimum pH was found to be above 5. When other cations such as Cu(II) or Zn(II) coexisted with Pb(II), the adsorption amount of Pb(II) decreased because of competing adsorption.

Dynamic Fixedbed Adsorption of Radionuclides from Aqueous Solutions by Inorganic Adsorbents

  • Lee, Hoo-Kun;Park, Geun-Il;Byeon, Kee-Hoh;Ro, Sung-Gy;Park, Hyun-Soo
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.409-414
    • /
    • 1996
  • Radionuclides such as Cs and Sr were removed from dilute aqueous solutions by means of inorganic adsorbents, 13X and chabazite. The physical adsorption obeyed the DA equation and non-equilibrium dynamic adsorption model, which describes surface diffusion mechanism with the DA equation, simulated the adsorption behavior of cesium and strontium on zeolite in fixed bed adsorbers. The dynamic model simulated the adsorption behavior of cesium and strontium.

  • PDF

A Case Study of Desulphurization by Limestone Adsorbent in an Industrial CFBC Boiler

  • Park, Young-Goo;Kim, Seung-Ho;Jo, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E2
    • /
    • pp.67-74
    • /
    • 2005
  • Domestic anthracite contains a large amount of fine particles, which causes to fire the back side of the boiler and to form the clinker deteriorating the combustion efficiency. At this time, the fine limestone adsorbents for a desulphurization agent may be used to facilitate an aggravation of the boiler, so that fine mode of limestone (<0.1mm) has been used no more than $25\%$ in local power stations of Korea. The present test carried out with an in-situ boiler, however, showed that higher content $(up\;to\;50\%)$ of fine limestone particles did not entail any mal-function. In addition, the desulphurization was found to be as good as the old mode of limestone adsorbents.

필터시스템을 이용한 비소처리흡착제의 성능비교분석

  • Bang Seon-Taek;Kim Ju-Yong;Kim Gyeong-Ung
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.13-16
    • /
    • 2005
  • Laboratory and field experiments were conducted to study the effectiveness of five adsorbents for the removal of arsenic. The adsorbents included activated alumina (AA), iron coated AA (ICAA), and granular ferric hydroxide (GFH), granular ferric oxide (GFO), and granular titanium dioxide (GTD). Laboratory experiments were conducted to investigate arsenic removal using challenge water prepared in accordance with NSF International Standards 53 (ANSl/NSF 53-2001). Field experiments were conducted using arsenic-contaminated groundwater In laboratory experiment, the treatment capacity decreased in the following order GTD > GFO > GFH. In contrast, the treatment capacity decreased in the following order GFO > GTD > GFH > ICAA > Ah in field experiments.

  • PDF

Kinetic and Equilibrium Study of Lead (II) Removal by Functionalized Multiwalled Carbon Nanotubes with Isatin Derivative from Aqueous Solutions

  • Tahermansouri, Hasan;Beheshti, Marzieh
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3391-3398
    • /
    • 2013
  • The carboxylated multiwall carbon nanotubes (MWCNT-COOH) and functionalized with isatin derivative (MWCNT-isatin) have been used as efficient adsorbents for the removal of lead (Pb) from aqueous solutions. The influence of variables including pH, concentration of the lead, amount of adsorbents and contact time was investigated by the batch method. The adsorption of the lead ions from aqueous solution by modified MWCNTs was studied kinetically using different kinetic models. The kinetic data were fitted with pseudo-first-order, pseudo-second-order, and intra-particle diffusion models. The sorption process with MWCNT-COOH and MWCNT-isatin was well described by pseudo-second-order and pseudo-first-order kinetics, respectively which it was agreed well with the experimental data. Also, it involved the particle-diffusion mechanism. The values of regression coefficient of various adsorption isotherm models like Langmuir, Freundlich and Tempkin to obtain the characteristic parameters of each model have been carried out. The Langmuir isotherm was found to best represent the measured sorption data for both adsorbent.

Surface modified mesoporous silica (SBA-15) for phosphate adsorbents in water (표면 개질된 메조기공실리카를 이용한 수중의 인 제거)

  • Lee, Seung-Yeon;Choi, Jae-Woo;Lee, Sang-Hyup;Lee, Hae-Goon;Lee, Ki-Bong;Hong, Seok-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.719-724
    • /
    • 2011
  • The excessive phosphate in water causes eutrophication which destroys water environment. In this study, mesoporous silica was synthesized and several functional groups were attached on it. Samples were tested to identify the ability to remove phosphate. The structures of synthesized materials were analyzed by X-ray diffractions (XRD), Fourier transform-infrared (FT-IR) and surface area analysis, Brunauer-Emmett-Teller (BET). To determine the maximum phosphate adsorption capacities and sorption rate, the equilibrium test and kinetic test was conducted. Among functionalized SBA-15 samples, pure SBA-15 didn't adsorb phosphate but Al-SBA-15 and Ti-SBA-15 showed good performances to remove phosphate. The maximum phosphate adsorption capacity of Al-SBA-15 was efficient compared to other adsorbents.

Characterization of Adsorbents for the Solid-Phase Extraction of Trace Diphenylhydantoin from Biological Samples (생체시료로 부터 미량 디페닐히단토인의 고상추출에 사용될 흡착제의 특성)

  • Kim, Kyoung-Rae;Lee, Kyoung-Won;Shim, Weon-Hee
    • YAKHAK HOEJI
    • /
    • v.36 no.2
    • /
    • pp.120-125
    • /
    • 1992
  • Ths sorption and desorption properties of four different solid adsorbents were evaluated for the trace enrichment of diphenylhydantoin from biological samples. Graphitized carbon black(GCB) gave the highest adsorption coefficient. And among the organic solvents examined, methanol gave the highest desorption coefficient. Using the GCB column, the optimum elution volume of the eluting solvent was evaluated from the breakthrough curve of diphenylhydantoin. The usefulness of GCB as the solid adsorbent was examined for the solid-phase extraction of diphenylhydantoin from serum in the concentration range of $20-50\;{\mu}g/ml$.

  • PDF

Adsorption and Desorption Characteristics of Methyl iodide on Silver ion-Exchanged Synthetic Zeolite at High Temperature

  • Park, Geun-Il;Park, Byung-Sun;Cho, Il-Hoon;Kim, Joon-Hyung;Ryu, Seung-Kon
    • Nuclear Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.504-513
    • /
    • 2000
  • The adsorption characteristics of methyl iodide generated from the simulated off-gas stream on various adsorbents such as silver ion-exchanged zeolite (AgX), zeocarbon and activated carbon were investigated. An extensive evaluation was made on the optimal silver ion-exchanged level for the effective removal of methyl iodide at temperature up to 38$0^{\circ}C$. The degree of adsorption efficiency of methyl iodide on silver ion-exchanged zeolite is strongly dependent of silver ion-amount and process temperature. The influence of temperature, methyl iodide concentration and silver ion-exchanged level on the adsorption efficiency is closely related to the pore characteristics of adsorbents. It would be facts that the effective silver ion-exchanged level was about 10 wt%, based on the degree of silver utilization for the removal of methyl iodide.

  • PDF