• 제목/요약/키워드: adjacent structures

검색결과 717건 처리시간 0.034초

도심지 깊은굴착시 주변 건물 및 매설관 손상평가 (Deep Excavation-induced Building and Utility Damage Assessment)

  • 유충식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.85-95
    • /
    • 2002
  • A substantial portion of the cost of deep excavations in urban environments is devoted to prevent ground movements and their effects on adjacent buildings and utilites. Prediction of ground movements and assessment of the risk of damage to adjacent structures has become an essential part of the planning, design, and construction of a deep excavation project in the urban environments. This paper presents damage assessment techniques for buildings and utilities adjacent deep excavation, which can be readily used in practice.

  • PDF

지반굴착시 지반/구조물 상호작용이 고려된 구조물의 거동 평가 연구 (The Behavior of Adjacent Structures in Urban Excavation Considering Soil-Structure Interaction)

  • 양성우;김찬국;황의석;김주철;김학문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1024-1031
    • /
    • 2006
  • In this study using the finite different programs, FLAC2D to define affection of the soil-structure interface in evaluating the behavior of adjacent structures according to excavation, and tried to compare each the results of different 46 cases which were various condition of stories, length and locations from the excavation site. In the result of the numerical analysis, the affection of the interface was affected by the building stories, locations from the excavation site and shape ratio(length/height). Therefore, in the considering soil-structure interaction in the damage assessment and the behavior of the adjacent structures when excavation, is important in more accurate evaluation of the movement of structure. Also, the interface modification factor were proposed which can consider the interface.

  • PDF

A new equation based on PGA to provide sufficient separation distance between two irregular buildings in plan

  • Loghmani, Adel;Mortezaei, Alireza;Hemmati, Ali
    • Earthquakes and Structures
    • /
    • 제18권5호
    • /
    • pp.543-553
    • /
    • 2020
  • Past earthquakes experience shows that serious damage or collapse of buildings have dramatically accrued when sufficient separation distance has not been provided between two adjacent structures. The majority of past studies related to the pounding topic indicate that obtaining the gap size between two buildings is able to prevent collision and impact hazards during seismic excitations. Considering minimization of building collisions, some relationships have been suggested to determine the separation distance between adjacent buildings. Commonly, peak lateral displacement, fundamental period and natural damping as well as structural height of two adjacent buildings are numerically considered to determine the critical distance. Hence, the aim of present study is to focus on all mentioned parameters and also utilizing the main characteristic of earthquake record i.e. PGA to examine the lateral displacement of irregular structures close to each other and also estimate the sufficient separation distance between them. Increasing and decreasing the separation distance is inherently caused economical problems due to the land ownership from a legal perspective and pounding hazard as well. Therefore, a new equation is proposed to determine the optimum critical distance. The accuracy of the proposed formula is validated by different models and various earthquake records.

적응형 스마트 공유 TMD의 MIMO 제어알고리즘개발 (Development of Multi-Input Multi-Output Control Algorithm for Adaptive Smart Shared TMD)

  • 김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제15권2호
    • /
    • pp.105-112
    • /
    • 2015
  • A shared tuned mass damper (STMD) was proposed in previous research for reduction of dynamic responses of the adjacent buildings subjected to earthquake loads. A single STMD can provide similar control performance in comparison with two traditional TMDs. In previous research, a passive damper was used to connect the STMD with adjacent buildings. In this study, a smart magnetorheological (MR) damper was used instead of a passive damper to compose an adaptive smart STMD (ASTMD). Control performance of the ASTMD was investigated by numerical analyses. For this purpose, two 8-story buildings were used as example structures. Multi-input multi-output (MIMO) fuzzy logic controller (FLC) was used to control the command voltages sent to two MR dampers. The MIMO FLC was optimized by a multi-objective genetic algorithm. Numerical analyses showed that the ASTMD can effectively control dynamic responses of adjacent buildings subjected to earthquake excitations in comparison with a passive STMD.

인접구조물의 내진성능개선을 위한 준능동 MR감쇠기의 GA-최적퍼지제어 (GA-based Optimal Fuzzy Control of Semi-Active Magneto-Rheological Dampers for Seismic Performance Improvement of Adjacent Structures)

  • 윤중원;박관순;옥승용
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.69-79
    • /
    • 2011
  • This paper proposes a GA-based optimal fuzzy control technique for the vibration control of earthquakeexcited adjacent structures interconnected with semi-active magneto-rheological(MR) dampers. Rule-based fuzzy logic controllers are designed first by implementing heuristic knowledge and the genetic algorithm(GA) is then introduced to optimally tune the fuzzy controllers for enhancing the seismic performance of semi-active control system. For practical implementation, the fuzzy controller simply uses locally measured responses of the dampers involved and directly returns the input voltage to the magneto-rheological dampers in real time through the fuzzy inference mechanism. The local measurement based fuzzy controller provides optimal damping force in a decentralized manner so that it does not require a primary central controller unlike the conventional semi-active control techniques. As a result, it can avoid the unbridgeable discrepancy between the desired control force and the actual damper force that may occur in the conventional control approaches. The validity and effectiveness of the proposed control method are shown numerically on two 20-story earthquake-excited buildings interconnected with MR dampers.

연결 제어 시스템 기반의 멀티해저드 적응형 스마트 제어 기술 성능 평가 (Performance Evaluation of Multi-Hazard Adaptive Smart Control Technique Based on Connective Control System)

  • 김현수
    • 한국공간구조학회논문집
    • /
    • 제18권4호
    • /
    • pp.97-104
    • /
    • 2018
  • A connected control method for the adjacent buildings has been studied to reduce dynamic responses. In these studies, seismic loads were generally used as an excitation. Recently, multi-hazards loads including earthquake and strong wind loads are employed to investigate control performance of various control systems. Accordingly, strong wind load as well as earthquake load was adopted to evaluate control performance of adaptive smart coupling control system against multi-hazard. To this end, an artificial seismic load in the region of strong seismicity and an artificial wind load in the region of strong winds were generated for control performance evaluation of the coupling control system. Artificial seismic and wind excitations were made by SIMQKE and Kaimal spectrum based on ASCE 7-10. As example buildings, two 20-story and 12-story adjacent buildings were used. An MR (magnetorheological) damper was used as an adaptive smart control device to connect adjacent two buildings. In oder to present nonlinear dynamic behavior of MR damper, Bouc-Wen model was employed in this study. After parametric studies on MR damper capacity, optimal command voltages for MR damper on each seismic and wind loads were investigated. Based on numerical analyses, it was shown that the adaptive smart coupling control system proposed in this study can provide very good control performance for Multi-hazards.

추계학적 선형화 방법 및 다목적 유전자 알고리즘을 이용한 지진하중을 받는 인접 구조물에 대한 비선형 감쇠시스템의 최적 설계 (Optimal design of nonlinear damping system for seismically-excited adjacent structures using multi-objective genetic algorithm integrated with stochastic linearization method)

  • 옥승용;송준호;고현무;박관순
    • 한국지진공학회논문집
    • /
    • 제11권6호
    • /
    • pp.1-14
    • /
    • 2007
  • 인접 구조물의 지진응답 제어를 위한 비선형 감쇠시스템의 최적 설계 방법에 관하여 연구하였다. 최적 설계를 위한 목적 함수로는 구조물의 응답과 감쇠기의 총 사용량을 고려하였으며, 상충하는 두 목적함수를 합리적인 수준에서 동시에 최소화하는 해를 구하기 위하여 유전자 알고리즘에 기반한 다목적 최적화 방법을 도입하였다. 또한, 최적화 과정에서 요구되는 비선형 시간이력해석을 수행하지 않고도, 비선형 이력감쇠기로 연결된 구조물의 지진응답을 효율적으로 평가하기 위하여 추계학적 선형화 방법을 접목하였다. 제시하는 방법의 효율성을 검증하기 위한 수치 예로서 20층과 10층의 인접 빌딩을 고려하였으며, 두 빌딩을 연결하는 비선형 감쇠시스템으로는 입력전압의 크기에 따라 변화하는 감쇠성능을 보이는 MR 감쇠기를 도입하였다. 제시하는 방법을 통하여 MR 감쇠기의 각 층별 최적 개수 및 감쇠용량을 결정할 수 있었으며, 이는 일반적인 균등분포 시스템에 비해 유사한 제어성능을 보이면서도 훨씬 경제적이었다. 또한, 인접구조물간 충돌에 대하여도 확률적으로 안정적인 거동을 보임을 검증하였으며, 제시하는 방법이 준능동 제어시스템의 최적 배치를 결정하기 위한 설계문제에도 적용할 수 있음을 보였다.

초고층 빌딩과 인접 지하구조물의 SSI를 고려한 동적해석과 유사정적해석의 거동 비교 연구 (A comparative study on the behavior of dynamic analysis and pseudo-static analysis considering SSI of a tall building and an adjacent underground structure)

  • 유광호;김승진
    • 한국터널지하공간학회 논문집
    • /
    • 제20권4호
    • /
    • pp.671-686
    • /
    • 2018
  • 최근 경주, 포항 인근에서 지진이 발생하여 대도시의 초고층 빌딩과 그에 인접한 지하구조물의 내진해석에 대한 사회적 요구가 증가하고 있다. 그러나 기존에 수행되어 왔던 대부분 내진해석 연구는 초고층 빌딩과 지하구조물을 개별적으로 분석하여 구조물간 동적 상호거동 연구가 부족한 실정이다. 따라서 본 연구에서는 기반암과 표층으로 이루어진 지반에 건물과 인접 지하구조물이 설치된 복합지하시설물을 대상으로 지반과 구조물을 동시에 고려한 동적해석을 수행하였다. 특히 신뢰도를 높이기 위해 유사정적해석을 추가로 수행하여 동적해석 결과와 비교 분석하였다. 종합적으로 복합시설물에 대한 SSI 해석 시 인접 지하구조물을 고려하는 것이 보다 보수적인 방법이라고 결론 내렸다.

수치해석을 통한 철도노반 인접 굴착 시 궤도틀림 분석 (Numerical Analysis of Track Irregularity in Excavation Adjacent to Railway Trackbed)

  • 이석준;오동욱;장성민;반즈락츠가랍;정혁상
    • 한국지반환경공학회 논문집
    • /
    • 제24권12호
    • /
    • pp.39-45
    • /
    • 2023
  • 본 논문에서는 3차원 수치해석을 통해 철도 노반에 인접한 굴착공사 시 궤도의 틀림을 분석하였다. 철도 노반에 인접한 굴착 공사는 열차 주행에 영향을 미칠 가능성이 높아 공사 시 인접 구조물의 안정성 및 영향성 검토를 필수로 수행하고 있지만, 그럼에도 불구하고 공사에 따른 침하 및 궤도틀림이 지속적으로 보고되고 있다. 굴착공사로 인한 지하수위, 지반의 응력 상태 변화 등은 인접 굴착 공사에 따른 구조물의 침하와 궤도틀림의 원인으로 지적되고 있다. 따라서, 본 연구에서는 인접 굴착 공사 시 궤도 틀림을 유발하는 인자를 변수로 고려하여 수치해석을 수행하였으며 운행 열차를 모사하기 위해 KRL-2012 표준 열차하중을 적용하였다. 분석 결과, 열차하중의 위치, 굴착지점과의 거리가 궤도틀림에 큰 영향을 미치는 것으로 나타났으며, 열차 하중이 작용할 때 궤도 틀림이 크게 발생하는 것으로 나타났다. 지하수위의 영향은 크지 않은 것으로 나타났다.

구조물 및 시설물 인접 구릉지의 암반굴착 발파설계 (Blast Design of Hilly Rock Excavation Adjacent to Structures and Facilities)

  • 류창하;선우춘;신희순;정소걸;최병희
    • 터널과지하공간
    • /
    • 제4권1호
    • /
    • pp.38-46
    • /
    • 1994
  • This paper concerns the design of blasts adjacent to structures and facilities. In order to investigate the site characteristics, measurements of in-situ wave propagation and laboratory tests of rock cores taken from the boreholes were carried out. Effects of rock media and delay intervals on ground vibration levels were identified from over sixty measurements of three times of test blasts. For practical use in the field, an empirical propagation equation was derived so as to reflect the characteristics of rock media and delay effects. Safe limits of vibration level for structures were conservatively established based on various suggested criteria. Safe limits for facilities were adopted so that vibration levels induced by blasting should not exceed the allowable limits specified in the manufacturer's installation condition. Suggested were blast pattern and operation to enhance the rock fracturing and to reduce the ground vibration levels under the restricted conditions.

  • PDF