• 제목/요약/키워드: adjacent building

검색결과 348건 처리시간 0.019초

음영조건을 고려한 공동주택 옥상 태양광모듈의 배치계획 평가 연구 (Evaluation on the Photovoltaic Module Arrangement Planning Considering Shading Conditions in Apartment Buildings)

  • 이겨레;이윤선;임재한
    • 대한건축학회논문집:구조계
    • /
    • 제35권5호
    • /
    • pp.169-179
    • /
    • 2019
  • During the initial design stage of apartment complex, the photovoltaic(PV) system has been considered as an alternative of renewable energy system and planned to install at the rooftop floor level in general. The electric power generation characteristics can be influenced by the block layout, building orientation and roof top structure because of azimuth angle, tilt angle, and partial shading. This study aims to investigate power generation characteristics of photovoltaic system in apartment buildings by considering the partial shading conditions due to the block layout, building orientation and roof-top structures. For the photovoltaic module arrangement planning in rooftop floor level, shading areas were firstly analyzed due to the adjacent building structure. And the annual and seasonal power generation of PV system were analyzed through the PVsyst simulation results. The results show that shading period at the roof top surface can be increased due to the parapet and water tank. Initial design power capacity can be decreased by considering the daily insolation period and distance between PV modules through the shading simulation. As the number of PV modules decreases, the annual power generation can be decreased. However annual power generation per unit area of PV modules can be increased and performance ratio can be increased above 80%. Also the power generation of PV system can be critically affected by building orientation and the performance ratio can be drastically decreased in east-oriented buildings due to the shading problems caused by adjacent structures at roof top level such as parapet and water tank.

그림자 정보를 이용한 KOMPSAT 위성영상에서의 건물 검출 (Building Detection Using Shadow Information in KOMPSAT Satellite Imagery)

  • 예철수;이쾌희
    • 대한원격탐사학회지
    • /
    • 제16권3호
    • /
    • pp.235-242
    • /
    • 2000
  • 본 논문에서는 그림자 정보를 사용하여 위성 영상에서 건물을 검출하는 기법을 제안한다. 비교적 일정한 밝기값 분포를 가지는 건물을 검출하기위해 영상을 건물, 그림자 그리고 배경의 세가지 영역으로 분류한다. 건물 영역 및 그림자 영역에 대해 잡음을 제거하고 그림자 영역에 인접한 건물을 건물과 그림자 크기에 대한 제약 조건을 적용하여 검출한다. 본 논문에 사용된 영상은 KOMPSAT 위성영상과 SPOT 위성영상을 사용하였으며 위성영상내의 건물을 효과적으로 검출할 수 있었다.

인접건축물의 진동제어를 위한 MR감쇠기의 위치 선정에 관한 연구 (Performance Evaluation of Vibration Control of Adjacent Buildings According to Installation Location of MR damper)

  • 김기철;강주원
    • 한국강구조학회 논문집
    • /
    • 제24권1호
    • /
    • pp.91-99
    • /
    • 2012
  • 최근 인접 건축물의 진동제어와 관련된 연구가 몇몇 연구자에 의하여 수행되고 있으며 그리고 구조물의 지진동 제어를 위하여 준능동 감쇠기의 일종인 MR 감쇠기가 적용되고 있다. 본 논문에서는 MR 감쇠기의 위치에 따른 인접 건축물의 지진동 제어성능을 분석하여 MR 감쇠기의 설치에 대한 최적의 위치를 선정하고자 한다. 본 연구를 위하여 인접한 20층과 15층 건축물을 예제 구조물로 사용하였으며 이 예제 구조물은 서로 다른 고유진동수를 갖게 하였으며 예제 구조물의 지진동 제어를 위하여 Groundhook 제어기법을 적용하였다. 예제 구조물의 수치해석에 의한 지진응답 분석결과, 변위응답 제어를 위하여 인접 건축물의 최상층에 MR 감쇠기를 설치하는 것이 제어성능에 있어서 우수하며 가속도응답을 제어하기 위해서는 인접 건축물의 중간층에 MR 감쇠기를 설치하는 것이 우수한 제어성능을 보이고 있다. MR 감쇠기를 중간층에 설치할 경우에, 변위응답과 가속도응답을 동시에 제어가 가능하다. 따라서 건축물의 제어 목표에 따라서 MR 감쇠기 설치위치를 적절하게 선정해야 할 것이다.

Interstory-interbuilding actuation schemes for seismic protection of adjacent identical buildings

  • Palacios-Quinonero, Francisco;Rubio-Massegu, Josep;Rossell, Josep M.;Rodellar, Jose
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.67-81
    • /
    • 2019
  • Rows of closely adjacent buildings with similar dynamic characteristics are common building arrangements in residential areas. In this paper, we present a vibration control strategy for the seismic protection of this kind of multibuilding systems. The proposed approach uses an advanced Linear Matrix Inequality (LMI) computational procedure to carry out the integrated design of distributed multiactuation schemes that combine interbuilding linking devices with interstory actuators implemented at different levels of the buildings. The controller designs are formulated as static output-feedback H-infinity control problems that include the interstory drifts, interbuilding approachings and control efforts as controlled-output variables. The advantages of the LMI computational procedure are also exploited to design a fully-decentralized velocity-feedback controller, which can define a passive control system with high-performance characteristics. The main ideas are presented by means of a system of three adjacent five-story identical buildings, and a proper set of numerical simulations are conducted to demonstrate the behavior of the different control configurations. The obtained results indicate that interstory-interbuilding multiactuation schemes can be used to design effective vibration control systems for adjacent buildings with similar dynamic characteristics. Specifically, this kind of control systems is able to mitigate the vibrational response of the individual buildings while maintaining reduced levels of pounding risk.

연결 제어 시스템 기반의 멀티해저드 적응형 스마트 제어 기술 성능 평가 (Performance Evaluation of Multi-Hazard Adaptive Smart Control Technique Based on Connective Control System)

  • 김현수
    • 한국공간구조학회논문집
    • /
    • 제18권4호
    • /
    • pp.97-104
    • /
    • 2018
  • A connected control method for the adjacent buildings has been studied to reduce dynamic responses. In these studies, seismic loads were generally used as an excitation. Recently, multi-hazards loads including earthquake and strong wind loads are employed to investigate control performance of various control systems. Accordingly, strong wind load as well as earthquake load was adopted to evaluate control performance of adaptive smart coupling control system against multi-hazard. To this end, an artificial seismic load in the region of strong seismicity and an artificial wind load in the region of strong winds were generated for control performance evaluation of the coupling control system. Artificial seismic and wind excitations were made by SIMQKE and Kaimal spectrum based on ASCE 7-10. As example buildings, two 20-story and 12-story adjacent buildings were used. An MR (magnetorheological) damper was used as an adaptive smart control device to connect adjacent two buildings. In oder to present nonlinear dynamic behavior of MR damper, Bouc-Wen model was employed in this study. After parametric studies on MR damper capacity, optimal command voltages for MR damper on each seismic and wind loads were investigated. Based on numerical analyses, it was shown that the adaptive smart coupling control system proposed in this study can provide very good control performance for Multi-hazards.

Frequency variation in construction stages and model validation for steel buildings

  • Aras, Fuat
    • Steel and Composite Structures
    • /
    • 제22권3호
    • /
    • pp.647-662
    • /
    • 2016
  • This study aims to monitor the variation of modal frequencies of steel buildings during their construction sequence. In this respect, construction of a steel building is followed by vibration based measurements. The monitored building is a three-story educational building within a building group whose structural system consists of steel moment resisting steel frames and eccentric braces. Five different acceleration measurements in two perpendicular directions are taken on five different construction stages, starting from the erection of the columns and beams ending with the completion of the construction. The recorded measurements are transferred into frequency domain and the dominant frequencies for each case have been determined. The change in the dominant frequencies is evaluated with the existing construction stages and performed constructional works between the stages. The last measurement, performed on the building in service, revealed the first two dominant frequencies as mutual in X and Y direction, showing that these dynamic modes are torsional modes. This result is investigated by numerical analysis performed with finite element model of the building constructed for design purpose. Lower frequencies and different mode shapes are determined from numerical analysis. The reason of lower frequencies is discussed and the vibration survey is extended to determine the effects of an adjacent building. The results showed that the building is in strong relation with an adjoining building in spite of a designed construction joint.

태양광 패널 설치를 고려한 건축 디자인 지침 개발 연구 (A Study on the Building Design Guideline Development Considering Photovoltaic Panel Installation)

  • 문창호
    • 대한건축학회연합논문집
    • /
    • 제21권4호
    • /
    • pp.139-146
    • /
    • 2019
  • The purpose of this study is to propose the building design guideline considering photovoltaic panel installation through the analysis of relevant guidelines from home and abroad in terms of building design and solar panel installation. Conclusions can be summarized as followings; Considerations in building design : selection of the site with high solar accessibility, avoidance of the shade from the adjacent building & trees, south facing orientation of solar panel in building design, removal of shade on the solar panel from the part of building itself, load consideration of solar panel & fixing materials, safe passage securement for solar system maintenance, and planning of piping and mechanical room for solar system. Considerations in solar panel installation : harmonizing of solar panel with surrounding environment, unity of solar panel orientation & slope, regular maintenance of solar system, (in case of flat roof installation) solar panel installation afloat over the roof, installation area within the roof floor, and lower than parapet height, (in case of sloped roof installation) solar panel installation parallel with the roof slope, ventilation space securement below the panel, installation area within the roof surface, and similar material installation in empty space.

Structural Design and Construction of High-rise Building to Feature the High-performance Oil Dampers for Vibration Control - Hibiya Mitsui Tower -

  • Kato, Takashi;Hara, Kenji;Tanaka, Hiroyuki
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.229-234
    • /
    • 2019
  • This report introduces the structural design of Hibiya Mitsui Tower built in Tokyo Midtown Hibiya. The upper part of this tower is used for offices and the lower portion is for commercial facilities and a cinema complex which need the large open spaces. The 192m-high building has 35 floors above ground and 4 below ground. The structure is a steel frame using CFT columns to feature the high-performance oil dampers and the buckling restrained braces for vibration control. First, an outline of the structural design of this building is presented. Second, we introduce the transfer frame adopted to realize the large open spaces in the lower part, and the long column supporting the corner part of the high-rise building to avoid making a shade on the adjacent Hibiya Park, which are the feature of this building. Finally, we present an outline of the latest highly efficient semi-active oil dampers adopted in this building, and the vibration responses of this tower.

Urban Density and the Porous High-Rise: The Integration of the Tall Building in the City - from China to New York

  • Klemperer, James von
    • 국제초고층학회논문집
    • /
    • 제4권2호
    • /
    • pp.135-142
    • /
    • 2015
  • As the skyscraper matures as a building type, its role in actively connecting to, and reinforcing, major threads of urban fabric becomes increasingly more important. The creation of public spaces inside of and adjacent to tall buildings allows for significant additions to the public realm, facilitating better connections between varied uses, providing needed access to critical transportation functions. In this more integrated version of the tall building type, the density afforded by a vertical structure is complemented by strategically devised porosity of plan and section. This paper examines three major tower projects which exemplify a progressive approach to permeable design: the recently completed Jingan Kerry Centre in Shanghai, the Lotte Supertower in Seoul, now half completed, and the One Vanderbilt tower being proposed next to Grand Central Terminal in New York City. These projects suggest possibilities for innovative approaches to private development strategies, public planning processes, and architectural design.

아파트 하향식 피난구에 대한 고찰 (Study on the Horizontally Installed Emergency Exit in Apartment Houses)

  • 여인환;민병렬
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 2부
    • /
    • pp.91-93
    • /
    • 2010
  • Recently, the regulation about HEE(horizontally installed emergency exit) established at upper 4story in apartment houses was introduced by revising enforcement degree of Building Act. HEE is a facility for egress to lower story through floor breach and ladder system so that it gives a useful evaquation way directly to an individual household in apartment when they failed to evacuate through the entrance door. HEE may offer an opportunity to optain two way egress path ways instead of evacuation space at balcony and through path way to adjacent household in building and that might be an big strengh. but it needs to guarantee for against the crime, getting detailed reviews for being security and supplementation of fire test methods.

  • PDF