• 제목/요약/키워드: adhesive pattern

검색결과 131건 처리시간 0.021초

고무층간 가교정도가 접착강도 및 파괴형태에 미치는 영향 (Effect of Degree of Interfacial Interlinking on Adhesive Strength and Fracture Morphology of Rubber Layers)

  • 김현재;강신영;나창운
    • Elastomers and Composites
    • /
    • 제34권1호
    • /
    • pp.31-44
    • /
    • 1999
  • 4종류의 고무(NR, SBR, EPDM, BIMS)에 대해 완전가교 고무층과 부분가교 고무층간 계면 결합의 변화에 따른 계면 접착강도를 $30{\sim}120^{\circ}C$ 조건에서 조사하였고, 전자현미경을 이용하여 접착파단면을 조사하였다. 두 개의 완전가교 고무층간 계면에서는 물리적 결합이 계면 접착강도에 주도적인 역할을 하였고, 완전가교 고무층과 부분가교 고무층간 계면에는 물리적 결합과 화학적 결합이 공존하여 계면 접착강도에 영향을 미쳤다. 접착강도가 응집 인열강도와 유사한 수준으로 높을 때 NR은 "계면 노티인열" 형태를, EPDM은 "cross-hatched" 형태를 보였다.

  • PDF

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.

Reattachment of Fractured Teeth : Case Report

  • 김덕수;박상진;박상혁;최경규
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2004년도 춘계 학술대회 (제121회) 초록집
    • /
    • pp.304-308
    • /
    • 2004
  • Maxillary anterior crown fractures are a common form of injury that mainly affects children and adolescents. The position of maxillary incisors and their eruptive pattern carries a significant risk for trauma. In the pre-adhesive era, fractured teeth needed to be restored either with pin-retained inlays or cast restorations that sacrificed healthy tooth structure and were a challenge for dentists to match with adjacent teeth. But. recently the development of adhesive dentistry has allowed dentists to use the patient's own fragment to restore the fractured tooth. The purpose of this paper is to present 2 cases of reattachment of fractured teeth which had different fracture mode, and to evaluate prognosis of cases.

  • PDF

폴리머를 이용한 CIS(CMOS Image Sensor) 디바이스용 웨이퍼 레벨 접합의 warpage와 신뢰성 (A Reliability and warpage of wafer level bonding for CIS device using polymer)

  • 박재현;구영모;김은경;김구성
    • 마이크로전자및패키징학회지
    • /
    • 제16권1호
    • /
    • pp.27-31
    • /
    • 2009
  • 본 논문에서는 웨이퍼 레벨 기술을 이용한 CIS용 폴리머 접합 기술을 연구하고 접합 후의 warpage 분석과 개별 패키지의 신뢰성 테스트를 수행하였다. 균일한 접합 높이를 유지하기 위하여 glass 웨이퍼 상에 dam을 형성하고 접합용 폴리머 층을 patterning하여 Si과 glass 웨이퍼의 접합 테스트를 수행하였다. Si 웨이퍼의 접합온도, 접합 압력 그리고 접합 층이 낮을수록 warpage 결과가 감소하였으며 접합시간과 승온 시간이 짧을수록 warpage 결과가 증가하는 것을 확인하였다. 접합 된 웨이퍼를 dicing 하여 각 개별 칩 단위로 TC, HTC, Humidity soak의 신뢰성 테스트를 수행하였으며 warpage 결과가 패키지의 신뢰성 결과에 미치는 영향은 미비한 것으로 확인되었다.

  • PDF

Self-Assembling Adhesive Bonding by Using Fusible Alloy Paste for Microelectronics Packaging

  • Yasuda, Kiyokazu
    • 마이크로전자및패키징학회지
    • /
    • 제18권3호
    • /
    • pp.53-57
    • /
    • 2011
  • In the modern packaging technologies highly condensed metal interconnects are typically formed by highcost processes. These methods inevitably require the precise controls of mutually dependant process parameters, which usually cause the difficulty of the change in the layout design for interconnects of chip to-chip, or chip-to-substrate. In order to overcome these problems, the unique concept and methodology of self-assembly even in micro-meter scale were developed. In this report we focus on the factors which influenced the self-formed bumps by analyzing the phenomenon experimentally. In case of RMA flux, homogenous pattern was obtained in both plain surface and cross-section surface observation. By using RA flux, the phenomena were accelerated although the self-formtion results was inhomogenous. With ussage of moderate RA flux, reaction rate of the self-formation was accelerated with homogeneous pattern.

Ultrastructure of the fertilized egg envelopes in Ancistrus cirrhosus, Loricariidae, Teleostei

  • Dong Heui Kim
    • Applied Microscopy
    • /
    • 제50권
    • /
    • pp.13.1-13.7
    • /
    • 2020
  • We examined the morphology of fertilized egg and ultrastructures of fertilized egg envelopes of Ancistrus cirrhosus belong to Loricariidae using light and electron microscopes. The fertilized eggs formed a mass on the spawning place and were yellowish, spherical, non-transparent, demersal, adhesive, and a narrow perivitelline space. But, the adhesiveness of fertilized eggs was disappeared after spawning excluding contact parts. The micropyle with funnel shape was surrounded by 15-19 furrow lines of egg envelope in a spoke-like pattern. The outer surface of egg envelope has smooth side and inner surface of egg envelope was rough with grooves. Also, the total thickness of the fertilized egg envelope was about 32.58 ± 0.85 ㎛ (n = 20), and the fertilized egg envelope consisted of three layers, an outer adhesive electron-dense layer, a middle layer with low electron density and an inner electron-dense layer with grooves in counter structure from other most teleost. Collectively, these morphological characteristics and adhesive property of fertilized egg, and ultrastructures of micropyle, outer surface, and section of fertilized egg envelope are showed species specificity.

Microstructure of the biological attachment devices in the ladybug Harmonia axyridis (Coleoptera: Coccinellidae)

  • Moon, Myung-Jin;Kim, Hyo-Jeong;Kim, Hoon;Park, Jong-Gu
    • Animal cells and systems
    • /
    • 제16권6호
    • /
    • pp.479-487
    • /
    • 2012
  • Biological attachment device is optimized in insect legs for attachment onto the variety of natural substrate. We have studied the microstructural characteristics of the tarsal appendages in the ladybug Harmonia axyridis using scanning electron microscopy to reveal the attachment system of their legs. The attachment devices are composed of claws and adhesive pads. The claws are connected with pretarsal segment, and their apical diverged hooks are developed to hold rough substrates. In contrast, the adhesive pads have an adhesive function onto smooth surface. The pads are interspersed at the ventral part of each tarsomere, and are composed of two kinds of hairy setae. The discoid tip seta (DtS) has a spoon-shaped endplate usually with a rounded concave structure, whereas the pointed tip seta (PtS) has a pointed tip, usually with a hooked endplate. While the PtS is broadly localized concentrically on the marginal area of both the proximal and distal pads, the DtS can be seen at the central areas of each adhesive pad except for the hind legs. Our findings demonstrate the presence of the direction-dependence pattern of the fibrillar system as well as a functional modification of the tenent setae to achieve proper contact with almost any kind of substrates.

Structural Changes of Adhesive Discs during Attachment of Boston Ivy

  • Kim, InSun
    • Applied Microscopy
    • /
    • 제44권4호
    • /
    • pp.111-116
    • /
    • 2014
  • This study investigates the developmental pattern of adhesive discs (ADs) to highlight the ontogeny and structural changes that occur during the growth of Boston ivy. Initiation to postmortem features of ADs were examined through light and scanning electron microscopy. The study also reveals a new finding of the dislocation of peripheral tissues of adaxial origin. Four phases of attachment are suggested with regards to its climbing behavior: 1) pre-attachment, 2) upon attachment, 3) after attachment, and 4) final attachment. During initiation, several ADs originate from tendril primordia without epidermal differentiation. However, different growth rates in the epidermis results in completely different ADs. ADs were discerned by size, shape, and color during expansion, but cells in the adaxial surface remained alive longer than the other side. Upon contact, the ADs demonstrate simultaneous growth and deterioration, but once attachment is established the latter process subdues to final stages. Epidermal transformation, adhesive secretion, cellular disruption, and mechanical stress were essential for the self-clinging nature of Boston ivy. The post-attachment sequence is also believed to be critical in achieving maximum mechanical strength to provide extensive support. The developmental process of ADs is prompted by tactile stimulation but in a highly organized and systematic manner.

주형온도가 CP Ti의 주조성에 미치는 영향 (Influence of the Mold Temperature on the Castability of CP Ti)

  • 정종현;주규지;고은경
    • 대한치과기공학회지
    • /
    • 제28권1호
    • /
    • pp.9-17
    • /
    • 2006
  • The purpose of this study was to evaluate the titanium castability with a spin type casting machine(TiCast, Super R, Selec, Osaka. Japan). We tested phosphate bonded investment "Rematitan$^{(R)}$Plus(Dentaurum, Inc., Pforzheim, Germany)"of mesh grid pattern and plate pattern. Four different mold temperatures(room temperature, 200$^{\circ}C$, 400$^{\circ}C$ and 600$^{\circ}C$) were prepared for the present study. In mesh grid pattern with spruing of $\varphi$0.88㎜ dimeter, when the mold temperature increased, high percentage of castability was gained. Mold temperature showed a highly significant(p<0.05) correlation on the castability, In plate pattern, the higher the mold temperature during casting, the greater the adhesive phenomenon between Ti surface and the investment.

  • PDF

자가 산부식 접착제를 이용한 치면열구전색의 미세누출 평가 (THE EVALUATION OF MICROLEAKAGE OF PIT AND FISSURE SEALANT BY USAGE OF SELF-ETCHING ADHESIVE SYSTEM)

  • 김현진;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제35권2호
    • /
    • pp.216-224
    • /
    • 2008
  • 자가 산부식 접착제는 산부식 과정 후 수세없이 와동을 충전할 수 있다. 움직임이 많고 행동 조절이 어려운 환자의 경우 시술의 절차를 줄일 수 있는 자가 산부식 접착제가 치면열구전색제의 사용을 보다 용이하게 할 수 있다. 그러나 법랑질에 대한 산부식 능력이 인산에 비해 낮아서 충분한 부식이 일어나는지에 대해 논란이 되고 있다. 이에 대해 자가 산부식 접착제의 약한 산부식능을 감안하여 열구성형술과 acidic primer의 도포 시간을 증가시키는 등의 임상 술식을 시행하고 자가 산부식 접착제의 단점이 보완되는지를 알아보고자 하였다. 35% 인산으로 산부식 후 전색술을 시행한 경우와 자가 산부식 접착제를 사용하여 도포한 경우의 미세 누출도를 염색액의 침투도를 비교하고 주사전자현미경을 이용한 산부식상 관찰을 통하여 다음과 같은 결론을 얻었다. 1. 열구 성형술을 시행 후 자가산부식접착제를 도포한 군은 인산 부식 20초를 시행한 군과 자가산부식접착제를 20초, 40초 도포한 군보다 미세누출도가 더 낮았다. 2. 자가산부식접착제를 제조 회사의 지시에 따라 20초간 도포한 군과 40초로 늘려 도포한 군 간에 미세누출도의 유의차가 없었다. 3. 주사전자현미경 관찰 시 전형적인 산부식 양상은 인산부식 20초군에서만 관찰되었으며 열구성형술을 시행하고 자가산부식접착제를 도포한 군이 자가산부식접착제만 20, 40초 도포한 군보다는 표면 거칠기가 증가하였다.

  • PDF